Municipal Affairs Department Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Municipal Affairs Department - MAD Tender

Works
Eprocure
Opening Date15 Dec 2021
Closing Date7 Jan 2022
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Wbmad/ulb/hm/4348/nit-1018 Dated-04.12.2021.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
240V DP with fuse on L&N 30/32 A Standard, Havell's & Anchor

1

-

-

... More
415V TPN with fuse on L&N 1 5/16 A Standard, Havell's & Anchor

1

-

-

... More
415V TPN with fuse on L&N 30/32 A Standard, Havell's & Anchor

1

-

-

... More
(b) Supplying and fixing Sheet steel Main Switches on angle iron frame on wall

-

-

-

... More
415V TPN with fuse on L&N 60/63 A Standard, Havell's & Anchor

1

-

-

... More
415V TPN with fuse on L&N 100/125 A Standard, Havell's & Anchor

1

-

-

... More
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.

-

-

-

... More
Flat iron frame 32A L&T/Havell's

1

-

-

... More
Flat iron frame 63A L&T/Havell's

1

-

-

... More
Flat iron frame 100A L&T/Havell's

1

-

-

... More
Flat iron frame 125A L&T/Havell's

1

-

-

... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection

-

-

-

... More
SP 2-4A Legrand/Havell's

1

-

-

... More
SP 6-32A Legrand/Havell's

1

-

-

... More
SP 40A Legrand/Havell's

1

-

-

... More
SP 63A Legrand/Havell's

1

-

-

... More
SP 100A Legrand/Havell's

1

-

-

... More
SP 125A Legrand/Havell's

1

-

-

... More
DP 2-4A Legrand/Havell's

1

-

-

... More
DP 6-32A Legrand/Havell's

1

-

-

... More
DP 40A Legrand/Havell's

1

-

-

... More
DP 63A Legrand/Havell's

1

-

-

... More
DP 100A Legrand/Havell's

1

-

-

... More
DP 125A Legrand/Havell's

1

-

-

... More
TP 2-4A Legrand/Havell's

1

-

-

... More
TP 6-32A Legrand/Havell's

1

-

-

... More
TP 40A Legrand/Havell's

1

-

-

... More
TP 63A Legrand/Havell's

1

-

-

... More
TP 100A Legrand/Havell's

1

-

-

... More
TP 125A Legrand/Havell's

1

-

-

... More
FP 2-4A Legrand/Havell's

1

-

-

... More
FP 6-32A Legrand/Havell's

1

-

-

... More
FP 40A Legrand/Havell's

1

-

-

... More
FP 63A Legrand/Havell's

1

-

-

... More
FP 100A Legrand/Havell's

1

-

-

... More
FP 125A Legrand/Havell's

1

-

-

... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection

-

-

-

... More
SPN 6-32A Legrand/Havell's

1

-

-

... More
SPN 40A Legrand/Havell's

1

-

-

... More
SPN 63A Legrand/Havell's

1

-

-

... More
TPN 6-32A Legrand/Havell's

1

-

-

... More
TPN 40A Legrand/Havell's

1

-

-

... More
TPN 63A Legrand/Havell's

1

-

-

... More
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection

-

-

-

... More
FP 63A Legrand/Havell's

1

-

-

... More
FP 80A Legrand/Havell's

1

-

-

... More
FP 100A Legrand/Havell's

1

-

-

... More
FP 125A Legrand/Havell's

1

-

-

... More
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment

-

-

-

... More
2 Way

1

-

-

... More
4 Way

1

-

-

... More
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.

-

-

-

... More
2+4 way Enclosure Legrand/Havell's

1

-

-

... More
2+8 way Enclosure Legrand/Havell's

1

-

-

... More
2+12 way Enclosure Legrand/Havell's

1

-

-

... More
2+16 way Enclosure Legrand/Havell's

1

-

-

... More
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment

-

-

-

... More
4 way Enclosure Legrand/Havell's

1

-

-

... More
6 way Enclosure Legrand/Havell's

1

-

-

... More
8 way Enclosure Legrand/Havell's

1

-

-

... More
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment

-

-

-

... More
Upto 160A 4 way Enclosure Legrand/Havell's

1

-

-

... More
Upto 160A 8 way Enclosure Legrand/Havell's

1

-

-

... More
Upto 160A 12 way Enclosure Legrand/Havell's

1

-

-

... More
Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991)

-

-

-

... More
2 bars 240 V, 63 A

1

-

-

... More
4 bars 415 V, 63 A

1

-

-

... More
4 bars 415 V, 100/125 A

1

-

-

... More
4 bars 415 V, 200 A

1

-

-

... More
4 bars 415 V, 315 A

1

-

-

... More
4 bars 415 V, 415 A

1

-

-

... More
4 bars 415 V, 600 A

1

-

-

... More
4 bars 415 V, 1000 A

1

-

-

... More
(a) Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board

1

-

-

... More
(b) Supplying & Fixing 240 V AC/DC superior type Multitune (min 10 nos. tune) Call Bell (Anchor) with selector switch for single/Multi Tunes mode, Battery operated on HW board incl. S&F HW board

1

-

-

... More
Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991)

1

-

-

... More
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.

1

-

-

... More
14. Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.

-

-

-

... More
2 x 22/0.3 (1.5 sqmm)

1

-

-

... More
2 x 22/0.3 (1.5 sqmm)+1x

1

-

-

... More
2 x 36/0.3 (2.5 sqmm)+1x

1

-

-

... More
2 x 56/0.3 (4 sqmm)+1x

1

-

-

... More
2 x 56/0.3 (4 sqmm)+1x

1

-

-

... More
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface ] (a) Average run 5 mtr

1

-

-

... More
(b) Average run 6 mtr

1

-

-

... More
(c) Average run 8 mtr

1

-

-

... More
(d) Average run 9 mtr

1

-

-

... More
(e) Average run 10 mtr

1

-

-

... More
(f) Average run 11 mtr

1

-

-

... More
(g) Average run 12 mtr

1

-

-

... More
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works [PVC casing-capping on surface and Switch board concealed] (a) Average run 5 mtr

1

-

-

... More
(b) Average run 6 mtr

1

-

-

... More
(c) Average run 8 mtr

1

-

-

... More
(d) Average run 9 mtr

1

-

-

... More
(e) Average run 10 mtr

1

-

-

... More
(f) Average run 11 mtr

1

-

-

... More
(g) Average run 12 mtr

1

-

-

... More
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (approved make) for ECC in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall for horizontal & vertical runs and in suitable size PVC casing-capping (Precision make) for ceiling portion only, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works [only PVC casing-capping on ceiling and remaining portion concealed] (a) Average run 5 mtr

1

-

-

... More
(b) Average run 6 mtr

1

-

-

... More
(c) Average run 8 mtr

1

-

-

... More
(d) Average run 9 mtr

1

-

-

... More
(e) Average run 10 mtr

1

-

-

... More
(f) Average run 11 mtr

1

-

-

... More
(g) Average run 12 mtr

1

-

-

... More
Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works (a) 20x10mm Size

1

-

-

... More
(b) 25x12mm Size

1

-

-

... More
(a) Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brandapproved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required

-

-

-

... More
2 x 22/0.3 (1.5 sqmm) + 1 x (1.5 sqmm)

1

-

-

... More
2 x 36/0.3 (2.5 sqmm) + 1 x (1.5 sqmm)

1

-

-

... More
2 x 56/0.3 (4 sqmm) + 1 x (2.5 sqmm)

1

-

-

... More
2 x 84/0.3 (6 sqmm) + 1 x (4.0 sqmm)

1

-

-

... More
3 x 22/0.3 (1.5 sqmm) + 1 x (1.5 sqmm)

1

-

-

... More
3 x 36/0.3 (2.5 sqmm) + 2 x (1.5 sqmm)

1

-

-

... More
b) Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 25mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required

-

-

-

... More
3 x 56/0.3 (4 sqmm) + 2x(2.5 sqmm)

1

-

-

... More
4 x 36/0.3 (2.5 sqmm) + 2x(1.5 sqmm)

1

-

-

... More
4 x 56/0.3 (4 sqmm) + 2x(2.5 sqmm)

1

-

-

... More
3 x 84/0.3 (6 sqmm) + 2x(4.0 sqmm)

1

-

-

... More
4 x 84/0.3 (6 sqmm) + 2x(4.0 sqmm)

1

-

-

... More
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish

-

-

-

... More
(a) Average run 5 mtr

1

-

-

... More
(b) Average run 6 mtr

1

-

-

... More
(c) Average run 8 mtr

1

-

-

... More
(d) Average run 9 mtr

1

-

-

... More
(e) Average run 10 mtr

1

-

-

... More
(f) Average run 11 mtr

1

-

-

... More
(g) Average run 12 mtr

1

-

-

... More
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish (a) On Board

1

-

-

... More
(b) Average run 1.5 mtr

1

-

-

... More
(c) Average run 3 mtr

1

-

-

... More
(d) Average run 4.5 mtr

1

-

-

... More
(e) Average run 6 mtr

1

-

-

... More
(f) Average run 7.5 mtr

1

-

-

... More
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works (a) 20mm size

1

-

-

... More
(b) 25mm size

1

-

-

... More
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works (a) 4 Module

1

-

-

... More
(b) 6 Module

1

-

-

... More
(c) 8 Module

1

-

-

... More
(d) 12 Module

1

-

-

... More
(e) 2 Row 12 Module

1

-

-

... More
(f) 2 Row 18 Module

1

-

-

... More
Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works (a) 2 Module

1

-

-

... More
(b) 4 Module

1

-

-

... More
(a) Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required

1

-

-

... More
(b) Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required

1

-

-

... More
(a) Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

1

-

-

... More
b) Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

1

-

-

... More
C) Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

1

-

-

... More
(a) Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.

1

-

-

... More
b) Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.

1

-

-

... More
(a) Supply & Fixing 240 V, 10 A, 2(Two) way Modular type switch (approved make) on existing GI Modular switch board having top cover plate and making necessary connections as required

1

-

-

... More
b) Supply & Fixing 240 V, 16 A, 2(Two) way Modular type switch (Brand approved by EIC) on existing GI Modular switch board having top cover plate and making necessary connections as required

1

-

-

... More
(a)Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

1

-

-

... More
b) Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

1

-

-

... More
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.

1

-

-

... More
Fixing only Modular type fan regulator on existing Modular GI switch board with top cover plate incl. making necy. connections etc.

1

-

-

... More
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approvedby EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular typeswitch board with 2 row 18 Module top cover plate flushed inwall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

1

-

-

... More
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 12 Module GI Modular type switch board with 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

1

-

-

... More
Supply & Fixing 240 V, 4 nos. 16 A, 3 pin Modular type plug socket with 4 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

1

-

-

... More
Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

1

-

-

... More
Supply & Fixing 240 V, 25A Modular starter (Brand approved by EIC) on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.

1

-

-

... More
Concealed Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire ‘'FR' and Modular type Switches.

-

-

-

... More
1. Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC a) Average run 6 mtr

1

-

-

... More
a) Average run 7 mtr

1

-

-

... More
a) Average run 8 mtr

1

-

-

... More
a) Average run 9 mtr

1

-

-

... More
a) Average run 10 mtr

1

-

-

... More
a) Average run 11 mtr

1

-

-

... More
a) Average run 12 mtr

1

-

-

... More
2. Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) in 19 mm bore, 3 mm thick polythenpipe complete with all accessories embedded in wall to 240 V6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular typeplug socket & Modular type switch (Brand approved by EIC)incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC a) On Board

1

-

-

... More
b) Average run 1.5 mtr

1

-

-

... More
c) Average run 3 mtr

1

-

-

... More
d) Average run 4.5 mtr

1

-

-

... More
e) Average run 6 mtr

1

-

-

... More
f) Average run 7.5 mtr

1

-

-

... More
(A) Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting

1

-

-

... More
(B) Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting

1

-

-

... More
(C) Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting

1

-

-

... More
D) Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting

1

-

-

... More
(a) Laying of one No. cable upto 35 sqmm in underground trench 460mm wide x 760 mm average depth, with brick protection on thetop of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed

1

-

-

... More
b) Laying of one No. cable above 35 sqmm and upto 185 sqmm inunderground trench 460mm wide x760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed

1

-

-

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : (a) For 4 core upto 4 sqmm

1

-

-

... More
upto 6 sqmm

1

-

-

... More
upto 10 sqmm

1

-

-

... More
upto 16 sqmm

1

-

-

... More
upto 25 sqmm

1

-

-

... More
upto 35 sqmm

1

-

-

... More
upto 50 sqmm

1

-

-

... More
upto 70 sqmm

1

-

-

... More
upto 95 sqmm

1

-

-

... More
upto 120 sqmm

1

-

-

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 core 2.5 sqmm cable

1

-

-

... More
4 core 4 sqmm cable

1

-

-

... More
4 core 6 sqmm cable

1

-

-

... More
4 core 10 sqmm cable

1

-

-

... More
4 core 16 sqmm cable

1

-

-

... More
4 core 25 sqmm cable

1

-

-

... More
3½ core 25 sqmm cable

1

-

-

... More
3½ core 35 sqmm cable

1

-

-

... More
3½ core 50 sqmm cable

1

-

-

... More
3½ core 70 sqmm cable

1

-

-

... More
3½ core 95 sqmm cable

1

-

-

... More
3½ core 120 sqmm cable

1

-

-

... More
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., includingsupplying sockets, tapes. I) 2.5sqmm

1

-

-

... More
II) 4 sqmm

1

-

-

... More
III) 6 sqmm

1

-

-

... More
IV) 10sqmm

1

-

-

... More
V) 16sqmm

1

-

-

... More
Straigh through Jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials (Brand approved by EIC) 2 core 4-10 sqmm cable

1

-

-

... More
2 core 16-25 sqmm cable

1

-

-

... More
3½ / 4 core 4-6 sqmm cable

1

-

-

... More
3½ / 4 core 10-16 sqmm cable

1

-

-

... More
3½ / 4 core 25-35 sqmm cable

1

-

-

... More
3½ / 4 core 50 sqmm cable

1

-

-

... More
3½ / 4 core 70 sqmm cable

1

-

-

... More
3½ / 4 core 95 sqmm cable

1

-

-

... More
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required ISI-M (a) 25 mm dia

1

-

-

... More
(b) 32 mm dia

1

-

-

... More
(c) 40 mm dia

1

-

-

... More
(d) 50 mm dia

1

-

-

... More
(e) 65 mm dia

1

-

-

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S &F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe

1

-

-

... More
By TATA-Medium GI pipe

1

-

-

... More
(i) S & Fixing of galvanized (hot dip) MS Flat (25x6 mm) for earthing

1

-

-

... More
(ii) S & Fixing of galvanized (hot dip) MS Flat (35x6 mm) for earthing

1

-

-

... More
i) Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly Upto 9.0 mtr. 0.6x0.6x1.70 mts

1

-

-

... More
Above 9.0 mtr. 0.6x0.6x1.91 mts

1

-

-

... More
Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, without Loop Box

1

-

-

... More
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint (a) Upto 9.0 mtr. long pole (i) 1st coat of aluminium paint over 1 coat of RO priming

1

-

-

... More
(ii) 2nd coat of aluminium paint over 1st coat

1

-

-

... More
(b) Above 9.0 mtr. long pole (i) 1st coat of aluminium paint over 1 coat of RO priming

1

-

-

... More
(ii) 2nd coat of aluminium paint over 1st coat

1

-

-

... More
(b) Painting of foundation structure of pole - 3 coat

1

-

-

... More
Street lights : 1. Distribution wiring for street light on pole with 2x1/1.40 PVC insulated and sheathed (single core) in 15 mm dia GI pipe (ISI Medium), without control switch incl. S&F 30.48 cm outdoor type dispersive light fitting with GI Pipe bracket and providing 25x6 mm Galv. MS flat clamps with bolts, nuts etc. and incl. painting (Av. run 3m)

1

-

-

... More
Dismantling steel tubular/Rail/Strut embedded in CC foundation incl. excavation, filling of holes, restoring surface, loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km

1

-

-

... More
The below content under Non Schedule a) Ceiling Fan Cleaning, Repairing & Painting

1

-

-

... More
b) Pedestal Fan Cleaning, Repairing & Painting

1

-

-

... More
a) Laying of cable by Jack Push Method through Micro Tunneling 2-3 M Deep.

1

-

-

... More
b) Laying of cable by breaking of concrete road upto 200 mm depth and mending good damages.

1

-

-

... More
SUPPLYING, LAYING OF HDPE PIPES, RATES OF HDPE PIPES GRADE -PE80 (PN-10.0), OD-50mm and ID- 40.8mm

1

-

-

... More
Straight through jointing of cable of different size By crimping method incl. supplying and fixing solderless Socket, tapes, anticorrosive paste & jointing materials.

1

-

-

... More
a) Supply & Fixing G.I. earth spike (1830mm x 20mm) with 6 SWG G.I. wire and nut bolt

1

-

-

... More
b) EARTHING & LIGHTING PROTECTION Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mmlong galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. Masonry enclosure and charcoal.

1

-

-

... More
a) Preparation of RCC foundation of 400 mm dia and 1500 mm Height with required materials rod cement chips and sand etc. at the ratio 1:2:4 with ground bolt 4 nos. for fitting the G.I. Octagonal Pole.

1

-

-

... More
b) Preparation of RCC foundation of 500 mm dia and 1800 mm Height with required materials rod cement chips and sand etc. at the ratio 1:2:4 with ground bolt 4 nos. for fitting the G.I. Octagonal Pole.

1

-

-

... More
c) Preparation of RCC foundation of 550 mm dia and 2200 mm Height with required materials rod cement chips and sand etc. at the ratio 1:2:4 with ground bolt 4 nos. for fitting the G.I. Octagonal Pole.

1

-

-

... More
Supply & installation of following materials:

-

-

-

... More
1. 2x6 mm2 un/Ar. Al. Cable

1

-

-

... More
2. 2x8 mm2 un/Ar. Cable

1

-

-

... More
3. 2x10 mm2 un/Ar. Al. Cable

1

-

-

... More
4. 4x4 mm2 un/Ar. Al. Cable

1

-

-

... More
5. 4x6 mm2 un/Ar. Al. Cable

1

-

-

... More
6. 4x10 mm2 un/Ar. Al. Cable

1

-

-

... More
7. 36W Electronics Choke

1

-

-

... More
8. Al. bars

1

-

-

... More
9. Cu. Bars

1

-

-

... More
10.Angular batten Holder (Anchor)

1

-

-

... More
11.Mini Mast Full Moon Bracket G.I.

1

-

-

... More
12.Pendent holder

1

-

-

... More
13.Decorative Ceiling Fan 48''

1

-

-

... More
14.Decorative Ceiling Fan 56''

1

-

-

... More
15.Wall Fan & Bracket (400mm dia)

1

-

-

... More
16.Wall Fan & Bracket (450mm dia)

1

-

-

... More
17.Wall Fan & Bracket (600mm dia)

1

-

-

... More
18.63 A Porcelain Fuse Kitkat

1

-

-

... More
19.100 A Porcelain Fuse Kitkat

1

-

-

... More
20.500 A Porcelain Fuse Kitkat

1

-

-

... More
21.19mm dia EI Conduit 1.6mm

1

-

-

... More
22.19mm dia GI conduit 1.6mm

1

-

-

... More
23.25mm dia GI Conduit 1.6mm

1

-

-

... More
24.13mm Polythene Pipe

1

-

-

... More
25.19mm Polythene Pipe

1

-

-

... More
26.25mm Polythene Pipe

1

-

-

... More
27.32mm Polythene Pipe

1

-

-

... More
28.16SWG MS Box 4"x4"x2.5"

1

-

-

... More
29.16SWG MS Box 6"x4"x2.5"

1

-

-

... More
30.16SWG MS Box 7"x4"x2.5"

1

-

-

... More
31.16SWG MS Box 8"x6"x2.5"

1

-

-

... More
32.16SWG MS Box 10"x8"x2.5"

1

-

-

... More
33.16SWG MS Box 10"x10"x2.5"

1

-

-

... More
34.16SWG MS Box 12"x8"x2.5"

1

-

-

... More
35.16SWG MS Box 16"x8"x2.5"

1

-

-

... More
36.16SWG MS Box 16"x10"x2.5"

1

-

-

... More
37.16SWG MS Box 18"x10"x2.5"

1

-

-

... More
38.3 way Circular Box

1

-

-

... More
39.4 way Circular Box

1

-

-

... More
40.PVC box of 100x100x0.065

1

-

-

... More
41.PVC box of 150x100x0.065

1

-

-

... More
42.PVC box of 250x200x0.065

1

-

-

... More
43.PVC box of 200x150x0.065

1

-

-

... More
44.PVC box of 300x250x0.065

1

-

-

... More
45.3 way Ceiling Rose/Batten Holder

1

-

-

... More
46.1.5 sq.mm 'FR' Copper wire

1

-

-

... More
47.2.5 sqmm'FR' Copper wire

1

-

-

... More
48.4.0 sqmm 'FR' Copper wire

1

-

-

... More
49.6.0 sqmm 'FR' Copper wire

1

-

-

... More
50.10 sqmm 'FR' Copper wire

1

-

-

... More
51.24/0.20mm twin twisted tinned copper flexible wire

1

-

-

... More
52.5 A, piano key type Switch

1

-

-

... More
53.5A, 2 way piano key type switch

1

-

-

... More
54.15A Piano key type Switch

1

-

-

... More
55.6A Piano key type Switch

1

-

-

... More
56.20A Piano key type Switch

1

-

-

... More
57.5 A, 3 pin Piano flush type Socket

1

-

-

... More
58.15A flushed type 3 pin Plug Socket

1

-

-

... More
59.Step Type Electronics Fan regulator

1

-

-

... More
60.1 module GI box

1

-

-

... More
61.2 module GI box

1

-

-

... More
62.4 module GI box

1

-

-

... More
63.6 module GI box

1

-

-

... More
64.2 row 12 module GI box

1

-

-

... More
65.2 row 18 module GI box

1

-

-

... More
66.1 module Cover plate

1

-

-

... More
67.2 module Cover plate

1

-

-

... More
68.3 module Cover plate

1

-

-

... More
69.4 module Cover plate

1

-

-

... More
70.6 module Cover plate

1

-

-

... More
71.2 row 12 module Cover plate

1

-

-

... More
72.2 row 18 module Cover plate

1

-

-

... More
73.Blank Plate for modular box

1

-

-

... More
74.Indicator Modular type

1

-

-

... More
75.6A Modular type Switch

1

-

-

... More
76.16A Modular type Switch

1

-

-

... More
77.6A Modular type 5 pin Plug Socket

1

-

-

... More
78.16A Modular type 6 pin Plug Socket

1

-

-

... More
79.10A Modular type 2 way Switch

1

-

-

... More
80.16A Modular type 2 way Switch

1

-

-

... More
81.Modular Soket type 2 module Regulator

1

-

-

... More
82.Modular TV socket

1

-

-

... More
83.ModularTelephone socket RJ11

1

-

-

... More
84.10/25A socket

1

-

-

... More
85.20/25A socket

1

-

-

... More
86.20/25A starter

1

-

-

... More
87.20/25A plug top

1

-

-

... More
88.25x6 GI Flat

1

-

-

... More
89.40mm dia HDPE Pipe

1

-

-

... More
90.10SWG GI wire

1

-

-

... More
91.50mm x 6mm Galv. Metre [Hot Dip] steel strip

1

-

-

... More
92.No. 4 S.W.G. GI [Hot Dip] wire

1

-

-

... More
93.Galv. [Hot Dip] MS Flat

1

-

-

... More
94.MS Flat iron chair (25 x 6 x 150mm MS flat)

1

-

-

... More
95.GI saddle etc …

1

-

-

... More
96.Copper Plate,Copper Strip

1

-

-

... More
97.Galv. Flat iron clamp (1½"x¼")

1

-

-

... More
98.Digital Energy Metre

1

-

-

... More
99.Computer Connecter Board

1

-

-

... More
100.Red led / Zinc Oxied primar

1

-

-

... More
101.Synthetic Enamel Paint Gr.II

1

-

-

... More
102.RO primar

1

-

-

... More
103.Alum. Paint

1

-

-

... More
Supply & Replacement of 1.1 KV Al. armored cable (Make-Havells Mescab & Gloster)

-

-

-

... More
2core x 6 sqmm

1

-

-

... More
2core x 10 sqmm

1

-

-

... More
2core x 16 sqmm

1

-

-

... More
4core x 4 sqmm

1

-

-

... More
4core x 6 sqmm

1

-

-

... More
4core x 10 sqmm

1

-

-

... More
4core x 16 sqmm

1

-

-

... More
4core x 25 sqmm

1

-

-

... More
4core x 50 sqmm

1

-

-

... More
4core x 70 sqmm

1

-

-

... More
4core x 95 sqmm

1

-

-

... More
3.5core x 125 sqmm

1

-

-

... More
A. Supply & replacement of 1.1 KV grade copper armored Cable (make- Havells & Mescab)

-

-

-

... More
2core x 1.5 sqmm

1

-

-

... More
2core x 2.5 sqmm

1

-

-

... More
2core x 4 sqmm

1

-

-

... More
3core x 1.5 sqmm

1

-

-

... More
3core x 2.5 sqmm

1

-

-

... More
B. Supply & replacement of 1.1 KV grade copper non armored Cable (make- Havells & Mescab)

-

-

-

... More
2core x 1.5 sqmm

1

-

-

... More
2core x 2.5 sqmm

1

-

-

... More
3core x 1.0 sqmm

1

-

-

... More
3core x 1.5 sqmm

1

-

-

... More
3core x 2.5 sqmm

1

-

-

... More
2core x 4 sqmm

1

-

-

... More
Replacement of demolished bollard decorative Luminair foundation including excavation and re-Construction of foundation with supply and grouting Of nut-bolts.

1

-

-

... More
Replacement of demolished tubular pole foundation Including excavation and re-construction of pole Foundation.

1

-

-

... More
A) Supply of 9 mtr. swaged type GI steel tubular pole(Bansal, Utkarsh/Bansal brand confirming to IS 2713 / 1980 on designation code 410 SP 26 with single swan neck arm to be extended up to 1 mtr. Of the part of the pole.

1

-

-

... More
B) Supply of 7 mtr. swaged type GI steel tubular pole(Bansal, Utkarsh/Bansal brand confirming to IS 2713 / 1980 on designation code with single swan neck arm to be extended up to 1 mtr. Of the part of the pole.

1

-

-

... More
A)Supply and installation of 8 M G.I. Octagonal Pole Hot Dipped galvanized with the nut, bolts and Straight arm of maximum 1.5M in Length excluding construction of RCC foundation.(Make-Volmont, Transrail, Utkarsha, Bajaj or equivalent).

1

-

-

... More
B) Supply and installation of 7 M G.I. Octagonal Pole Hot Dipped galvanized with the nut, bolts and Straight arm of maximum 1.5M in Length excluding construction of RCC foundation.(Make-Volmont, Transrail, Utkarsha, Bajaj or equivalent).

1

-

-

... More
C) Supply and installation of 9 M G.I. Octagonal Pole Hot Dipped galvanized with the nut, bolts and Straight arm of maximum 1.5M in Length excluding construction of RCC foundation.(Make-Volmont, Transrail, Utkarsha, Bajaj or equivalent).

1

-

-

... More
D) Supply and installation of 10 M G.I. Octagonal Pole Hot Dipped galvanized with the nut, bolts and Straight arm of maximum 1.5M in Length excluding construction of RCC foundation.(Make-Volmont, Transrail, Utkarsha, Bajaj or equivalent).

1

-

-

... More
E) S& Delivery 1.5 mtr. Long double bracket

1

-

-

... More
F) Supply of 12 M Hight Hot Dip Galvanized Octagonal Poles and 1 no Full Moon Bracket suitable to mount 4nos of non integral flood light fittings with clamping arrangement for climbing.

1

-

-

... More
Supply and installation of looping cable box 250mm(H) x200mm(W) x 100mm(D) made of 14 SWG steel sheet Duly hot deep galvanized and 2 nos x 25 x 6 mm GI clamps Complete with bolt and nuts etc.

1

-

-

... More
A. Supply and replacement of Feeder Pillar Box of size 1000 x 900 x 400 mm, having separate compartment at one side for metering arrangement on wooden board, made of 4 mm thick CRCA steel sheet, outdoor type with top canopy, sides having louvers for ventilation, double door, weather proof powder coating and would have 400 mm long 40 x 40 x 6 mm, 4 nos angle iron leg with 5 mm plate at their bottom end painted, complete with copper bus bar & extra locking arrangement as per direction of Engineer-in-Charge

1

-

-

... More
B. Repairing of feeder pillar with painting 1. Full body

1

-

-

... More
2. Door (both)

1

-

-

... More
3. Canopy

1

-

-

... More
4. Cover Sheet

1

-

-

... More
5. Foundation

1

-

-

... More
C. Replacement accessories of Electrical Panel Board i) 63A, 415V TPN Switch fuse unit with HRC Fuse (L&T/Havells)

1

-

-

... More
ii) 3P, 240V AC Coil Contactor, ML-3

1

-

-

... More
iii) 230V, 24Hrs. Time Switch (G/C or similar make)

1

-

-

... More
iv) 3P 415V AC Coil Contractor ML4

1

-

-

... More
v) 3P 415V Contractor MNX -32(L&T)

1

-

-

... More
vi) 3P 415V Contractor MNX - 40(L&T)

1

-

-

... More
vii) 415V Single phase preventer (Minilac)

1

-

-

... More
viii) 20/2A Control Fuse (GE/HPL)

1

-

-

... More
ix) Indicating lamp (LED) (Emco)

1

-

-

... More
x) Cubical illu, Lamp & Limit Switch

1

-

-

... More
xi) 4way/150A Power terminal (ACDC)

1

-

-

... More
xii) Toggle Switch

1

-

-

... More
xiii) Repair of Bus Bar

1

-

-

... More
xiv) HBC Fuse with base 2 Amp

1

-

-

... More
xv) 0-500V volt mtr. With selector switch

1

-

-

... More
xvi) HRC Fuse

1

-

-

... More
xvii) Internal wiring of Feeder Pillar Box

1

-

-

... More
xviii) Contract Coil MNX-30/40A

1

-

-

... More
xix) Contract Kit ML-3/ML-4

1

-

-

... More
xx) 150 Amp Power Connector

1

-

-

... More
xxi) Contract Coil 240 Volt

1

-

-

... More
xxii) Single Phase Contractor 240 volt (L&T)

1

-

-

... More
D. Supply and fixing of 750 X 550 X 300 mm Meter Box (G.I sheet of 2.5 m.m) with 32 Amp 3-ph.Iron Clad Main Switches 250V DP with fuse on L&N for outdoor arrangement and installation at the suitable PCC arrangement.

1

-

-

... More
E. Supply and installation of feeder pillar box of size 900 X 700 X 400 mm made of 2.5 mm thick (ISI Marked) steel sheet outdoor type with top canopy, sides having lovers for ventilation ,double door, weather proof epoxy painted (or of2.5 mm- GI Sheet), complete with 63Amp cu bus-bar & extra locking arrangement for operation of Street lighting System in single phase power system as per direction of engineer-in-charge including the Brick foundation 1800 X 500 X 1000 mm with plastering and neat cementing.(Consisting of following items in the feeder pillar) i) 40 Amp , 230 Volt Double Pole MCB 10 ka Breaking capacity ( Legrand/L & T)-1 no ii) DP 240 Volt 40 Amp air break AC Coil conductor (L&T)-1 no iii) 230Volt 24 Hrs time switch (L&T)-1 no iv) 5-10 Amp SPMCB ( Legrand)-4 No "C" cerve of 10 ka v) Indicating lamp (LED) (Emco)-1 No vi) Cubical ilu lamp & switch- 1 No. vii) 0-500V Voltmeter with selector switch -1 Set viii) Toggle switch - 1No ix) Power connecter-1 Set x) Amp Meter with C.T.

1

-

-

... More
Supply of Manpower A. Skilled

1

-

-

... More
B. Unskilled

1

-

-

... More
LED Road way luminaire with High power LED as light source and electronics driver Make- Philips/Havells/Bajaj or Equivalent A) 15 Watt

1

-

-

... More
B) 24 Watt

1

-

-

... More
C) 48 Watt

1

-

-

... More
D) 60 Watt

1

-

-

... More
E) 70 Watt

1

-

-

... More
F) 90 Watt

1

-

-

... More
G) 100 Watt

1

-

-

... More
H) 120 Watt

1

-

-

... More
I) 140 Watt

1

-

-

... More
J) 150 Watt

1

-

-

... More
K) 180 Watt

1

-

-

... More
L) 210 Watt

1

-

-

... More
A) LED Flood Light luminaire with High power LED as light source and electronics driver Make- Philips/Havells/Bajaj or Equivalent A) 50 Watt

1

-

-

... More
B) 80 Watt

1

-

-

... More
C) 150 Watt

1

-

-

... More
D) 160 Watt

1

-

-

... More
E) 200 Watt

1

-

-

... More
F) 240 Watt

1

-

-

... More
G) 300 Watt

1

-

-

... More
Supply & fixings out door type street light fittings with LED Lamp and other accessories I) 36W PL-L lamp

1

-

-

... More
II) 1000W Halogen light fittings with lamp (make-philips/equivalent)

1

-

-

... More
III) Tube Light Choke

1

-

-

... More
IV) Tube Light Starter

1

-

-

... More
V) Tube Light-36W

1

-

-

... More
VI) 1000 Watt Halogen Lamp

1

-

-

... More
VII) 11 Watt PL Lamp

1

-

-

... More
VIII) LED Tube 4 ft.

1

-

-

... More
IX) 33 MFD Condenser

1

-

-

... More
X) 12 MFD Condenser

1

-

-

... More
XI) 2.25 MFD Condenser

1

-

-

... More
XII) LED Bulb 7 watt

1

-

-

... More
XIII) LED Bulb 10 watt

1

-

-

... More
XIV) LED Bulb 15 watt

1

-

-

... More
XV) LED Bulb 18 watt

1

-

-

... More
XVI) LED Lamp 22 watt

1

-

-

... More
XVII) LED Tube fittings 2 ft.

1

-

-

... More
XVIII) Electronics Driver for LED St. light fittings:- A) 15 Watt

1

-

-

... More
B) 24 Watt

1

-

-

... More
C) 48 Watt

1

-

-

... More
D) 60 Watt

1

-

-

... More
E) 70 Watt

1

-

-

... More
F) 90 Watt

1

-

-

... More
G) 100 Watt

1

-

-

... More
H) 120 Watt

1

-

-

... More
I) 150 Watt

1

-

-

... More
J) 180 Watt

1

-

-

... More
K) 210 Watt

1

-

-

... More
XIX) Electronics Driver for LED Flood light fittings:- A) 50 Watt

1

-

-

... More
B) 80 Watt

1

-

-

... More
C) 100 Watt

1

-

-

... More
D) 120 Watt

1

-

-

... More
E) 150 Watt

1

-

-

... More
F) 200 Watt

1

-

-

... More
G) 240 Watt

1

-

-

... More
H) 300 Watt

1

-

-

... More
XX) 1000/500 Watt Halogen Lamp Holder

1

-

-

... More
XXI) 36 watt LED Tube light fittings

1

-

-

... More
Supply & Fixing LED Spot light 50 watt Make-K-Lite ; ID no.: 4261

1

-

-

... More
Supply & Fixing LED Spot light 25 watt Make-K-Lite ; ID no.: 7060

1

-

-

... More
Supply & Fixing LED Spike light 20 watt Make-K-Lite ; ID no.: 4273

1

-

-

... More
S& Installation LED Decorative garden light Make-K-Lite- VIRGO BOLLARD ID No-4761

1

-

-

... More
S& Installation LED Decorative garden light Make-K-Lite- MEXICAN BOLLARD ID No-4801

1

-

-

... More
a) Fixing only ceiling fan complete with blade, canopy ,fork, rubber bush etc.

1

-

-

... More
b) Supply of pedestal fan – 400mm

1

-

-

... More
c) Supply of pedestal fan – 450mm

1

-

-

... More
d) Supply of pedestal fan – 500mm

1

-

-

... More
e) Supply & delivery of exhaust fan (metal type) – 230mm

1

-

-

... More
f) Supply & delivery of exhaust fan (metal type) – 300mm

1

-

-

... More
g) Supply & delivery of exhaust fan (heavy duty) – 300mm

1

-

-

... More
h) Supply & delivery of exhaust fan (heavy duty) – 380mm

1

-

-

... More
Fixing only exhaust fan after making hole in wall and making good damages & smooth cement finish etc., as practicable as possible and providing necessary. Length of PVC insulated wire & making connection for exhaust fan.

1

-

-

... More
(i) Supply and Installation of Submersible Pump including all accessories:- Crompton / Kilosker A) 1 HP

1

-

-

... More
B) 1.5 HP

1

-

-

... More
C) 2 HP

1

-

-

... More
(ii) Supply and Installation Self Priming Centrifugal Pump:- A) 1HP

1

-

-

... More
B) 1.5 HP

1

-

-

... More
C) 2 HP

1

-

-

... More
Surface and wall mounted 22 watt LED batten (Make: Havell’s Cat no.: ENDURALINEAR NEO BS 22W LED 865 SPCWH Or equivalent)

1

-

-

... More
Surface and wall mounted 10 watt LED batten (Make: Havell’s Cat no.: ENDURALINEAR NEO BS 10W LED 865 SPCWH Or equivalent)

1

-

-

... More
Surface and wall mounted 40 watt LED batten (Make: Havell’s Cat no.: DURA BS 40W LED 865 SPCSS Or equivalent)

1

-

-

... More
Fully diffused recessed mounted 2’x2’, 36 watt LED Luminaire – Make-PHILIPS, Havell’s or equivalent

1

-

-

... More
Fully diffused recessed mounted 170x170mm, 12 watt LED Luminaire – Make-PHILIPS, Havell’s, Magik

1

-

-

... More
Fully diffused recessed mounted 300x300mm, 24 watt LED Luminaire – Make-PHILIPS, Havell’s, Magik

1

-

-

... More
S & Fixing LED flat panel 1’x1’ for 15 watt surface Mounting Luminaire – Make-Philips, Havell’s, Magik etc.

1

-

-

... More
S & Fixing LED flat panel 2’x2’ for 34 watt surface Mounting Luminaire – Make-Philips, Havell’s & Others

1

-

-

... More
S & Fixing LED flat panel 6 watt surface Mounting Luminaire (Square/Round) – Make-Philips, Havell’s, Magik or equivalent

1

-

-

... More
S & Fixing LED flat panel 12 watt surface Mounting Luminaire (Square/Round) – Make-Philips, Havell’s, Magik or equivalent

1

-

-

... More
S & Fixing LED flat panel 18 watt surface Mounting Luminaire (Square/Round) – Make-Philips, Havell’s, Magik or equivalent

1

-

-

... More
S & Fixing LED flat panel 24 watt surface Mounting Luminaire (Square/Round) – Make-Philips, Havell’s, Magik or equivalent

1

-

-

... More
S & Fixing LED Decorative light Panel Drivers with universal Connection for easy installation a) 6 watt

1

-

-

... More
b) 9W/12 watt

1

-

-

... More
c) 15W/18 watt

1

-

-

... More
d) 24 watt

1

-

-

... More
e) 36 watt

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.