Water Resources Development Directorate Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Water Resources Development Directorate - WRDD Tender

Works
Civil Works
Eprocure
Opening Date20 Nov 2019
Closing Date7 Dec 2019
Tender Amount₹ 1,51,42,577 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
PVC STRAINER (As per IS 12818-1997)

-

-

-

... More
(i) 100 mm dia.

180

-

445.33

... More
OTHER MATERIALS

-

-

-

... More
Supply of 100 mm dia PVC Lay Flat Hose

1200

-

148

... More
Supply of 3 Core 2.5 sq.mm flat waterproof cable Note: To be paid on actual execution as per specific requirements of site only as desired by the ENC

360

-

77

... More
Supply of M.S Hexagonal Head Nuts and Bolts conforming to IS 1365(Part-I)/1992 of product grade C with latest amendment for bolt & IS 1363(Part-III)/1992 of product grade C with latest amendment for Nuts properties / class for bolt 4.6 and for nut 4.5 16 mm x 50 mm Nut & Bolt

36

-

140

... More
Supply & transport of Rubber Insertion 5 mm thick with proper reinforcement 2 ply conforming to I.S.638/79 with ISI Mark with latest ammendments suitable for raised surface of M.S.Flange as per I.S. 6392/71 ( Table - 5, 11 & 17 ) b) 80 mm dia.

60

-

55

... More
PART-B. Drilling & Development of Tube well:- Drilling of bore hole of suitable diameter upto required depth by water jet system through any type of soil including hire and labour charges for boring pipes, scaffolding, other tools and plants etc. and taking out the same complete and other incidental works in this connection. The bore hole should have minimum 65 mm gap in between outside of the tube well pipe and the bore. a) for lowering 100 mm dia P.V.C. Pipe

732

-

262.14

... More
b) for lowering 150 mm dia P.V.C. Pipe

504

-

565.77

... More
Labour charges for lowering of pipe, strainers, blank pipe etc. and fitting, fixing the same including cutting, threading where necessary complete including bucket washing and other incidental works in this connection.

-

-

-

... More
i) 100 mm dia. UPVC pipe Blank, bottom plug with cutter, PVC ribbed strainer

684

-

70.73

... More
ii) 150 mm dia. PVC Housing Pipe

504

-

102.55

... More
Supplying and filling up of the annular space between the Well Pipe and the bore hole by coarse sand including watering as necessary as per direction of Engineer-in-Charge.

48

-

718.53

... More
Supplying , fitting and fixing150 mm dia ISI mark G.I. short Pipes of ( medium quality) of suitable length ( 0.60 m to 1.0 m ) with both end screwed, one end to match with the 150 mm dia housing pipe and the other end match with the 150 mm dia MS top cap as per direction of the E.I.C.

12

-

1430.46

... More
Supplying, fitting and fixing including supplying of suitable jointing compound for fixing in position, threading, if necessary etc. all complete

-

-

-

... More
i) 100 mm long dia. Steel Cutter piece upto 450 mm long with socket.

12

-

330.03

... More
ii) 100 mm X 150 mm dia P.V.C. Reducing socket.

12

-

471.48

... More
iii) 150 mm dia G.I. threaded top cap fixed in position.

12

-

565.77

... More
iv) 100 mm dia. Plug of approved make conforming to IS specifications.

12

-

150.87

... More
Washing and development by pumping with 30 cum per hour capacity pump for a period till sand free water comes out and the discharge is about 30 cum per hour, followed by final yield test; inclusive of all tools, plants and scaffolding and hire charge of submersible pump, generator etc. all complete.

12

-

4563.88

... More
Charges for Mobilisation of drilling equipments, tools and plants etc. and transportion of departmental materials from Sub-divisional store to work site and returning excess departmental materials if any, to Sub-divisional store after completion of work.

12

-

1810.46

... More
Making arrangement and showing varticality test and sounding test including cost / hire charges of necessary tools and plants, scaffolding, labour etc. all complete as per direction of Engineer-in-Charge.

12

-

858.08

... More
Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding literate of sand stone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed & including trimming the sides of trenches,leveling dressing & ramming the bottoms, bailing orpumping out of water etc. as required complete. a) Depth of excavation exceeding 1500 mm.

78.6

-

11927

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation.

12.3

-

7754

... More
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (Payment to be made on the basis of measurement of finished quantity of work).

39

-

93621

... More
Single brick flat soling of picked Jhama bricks including ramming & dressing bed to proper level & filling joints with local sand.

258

-

361

... More
Ordinary Cement Concrete (mix 1:2:4) with graded stone chips (20 mm. nominal size) excluding shuttering and reinforcement, if any, in ground floor, as per relevant IS codes. a) Pakur variety (1:2:4 Proportion) i) with approved Grade NB variety ( 20 mm size) ( 30 Km from nearest Kalyani Railway Stackyard)

18.156

-

5621.78

... More
Brickwork with 1st class bricks in cement morter (1:6) a) In foundation & Plinth

45.6

-

5413

... More
b) In superstructure, Ground Floor

6.6

-

5636

... More
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3)[with graded stone aggregate 10 mm nominal size] and painting the top surface with a coat of Bitumen [VG.40]using 1.7 Kg. Per sq.m. Including heating the bitumen and cost and carriage of materials complete [Bitumen to be supplied by the Agency] (at plinth level)

30

-

263

... More
Hire and labour charges for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing and striking out after completion of works. (upto roof of ground floor) (a) 25 mm. to 30 mm. thick wooden shuttering as per decision & direction of Engineer-in-charge.

204

-

335

... More
Ordinary Cement Concrete (mix 1:1.5:3) with graded stone chips (20 mm. nominal size) excluding shuttering and reinforcement, if any, in ground floor, as per relevant IS codes. i) Pakur Variety ( 30 Km from nearest Kalyani City Railway Stackyard)

27.6

-

6167.86

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups,binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4m. (i) Tor steel/Mild steel Other than SAIL/TATA/RINL

2.34

-

67191.43

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.

261

-

736

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding / staging where necessary (ground floor). [Excluding cost of chipping over concrete surface]

-

-

-

... More
(i) With 1:6 cement mortar (b) 20 mm. thick plaster for groung floor

210

-

175

... More
(i) With 1:6 cement mortar (b) 15 mm. thick plaster for groung floor

600

-

151

... More
(ii) With 1:4cement mortar (c) 10 mm. thick plaster

126

-

133

... More
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. NOTE: Cement 0.152 cu.m. Per 100 sq.m. In ground floor

454.2

-

34

... More
Atificial stone in floor, dado,staircase etc. with cement concrete 1:2:4 laid in panels as directed with topping made with ordinary 0r white cement (as directed) and marble dust in proportion (1:20 including smooth finishing and rounding off concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sqm all complete including all materials and labour. 25 mm thick artificial stone flooring ( using grey cement ) In ground floor, 3 mm thick topping ( high polishing grinding on this item is not permitted with ordinary cement) Using grey cement (a) 25 mm thick

79.2

-

273

... More
M.S. Or W.I. ornamental grill of approved design joints continuously welded with M.S. / W.I. flats and bars of windows, railings etc. Fitted and fixed with necessary screws and lugs in ground floor. (ii) Grill weighing above 16 kg/Sqm and above.

10.8

-

9696

... More
Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials .

49.2

-

1304

... More
Supplying, fitting and fixing iron hasp bolt of approved quality (oxidised) with 16 mm dia rod with centre bolt and round fitting 250 mm long

12

-

159

... More
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification.

624

-

49

... More
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

105.72

-

29

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : a) On steel or Other metal surfaces with Super gloss (hi-gloss) i) Two Coats ( with any shade except white).

105.72

-

79

... More
Supplying, fitting & fixing UPVC pipes A-Type and fittings conforming to IS 13592-1992 with all necessary clamps nails, including making holes in walls, floors etc. cutting trenches in any soil through masonary masonary concrete structures etc. if necessary and mending good damages including joining with jointing materials (Spun Yarn, Valamoid,/Bitumen/M-Seal etc.) complete. A) UPVC Pipes (i)75 mm Dia.

30

-

188

... More
B) UPVC Fittings (a) Plain Tee : 75 mm Dia

12

-

102

... More
(d) Shoe : 75 mm Dia

12

-

78

... More
Brickwork with 1st class bricks in cement morter (1:4) In foundation & Plinth

18.6

-

5682

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding / staging where necessary (ground floor). (i) With 1:4 cement mortar. 20 mm. thick plaster for groung floor.

442.2

-

194

... More
Supplying, fitting & fixing of G.I. Pipes of TATA make bifurcating at end point within concrete block with all necessary accessories, special viz. socket, bend, tee, union, cross, elbow, nipple, etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc all complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any posision above ground. a) 50 mm dia. (ii) Medium quality.

48

-

540

... More
Painting block letters or digits in black japan or any approved paint as per direction. (b) Size above 2.5 Cm and upto 4 cm.

3000

-

8

... More
(c) Size above 4 Cm and upto 5 cm.

600

-

10

... More
Supply of Godrej Lock 6 Levers (3 Keys)

12

-

448

... More
M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 808 & SP (6)- 1964 connected to one another with bracket, guests, cleats as per design, direction of Engineer-in-charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816-1969 & IS 1995 using electrodes of approved make and brand conforming to IS: 814-2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel sectoin, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work incuding all incidental charges such as electricity charges, labour insurance charges etc.

-

-

-

... More
I) For structural members of specified sections weighing less than 22.5 kg/m. Structural frame should be made with minimum 25mm X 25mm X 5mmth M.S. angels with necessary joints.

432

-

72.6

... More
Extra rate allowed over schedule rates @ 5% for construction of pump house of STW/LDTW concidering remote places, away from town except earthwork i.e. Rs..1,49,784.62X 5% ( For One T/W)

12

-

7489.23

... More
Instalation of submersible electro motor pumping set of following capacities by using necessary requisite, tools and plants by lowering the same within the tubewell housing pipe upto the following depth as per direction by fitting, fixing column pipes and other accessories, fixtures with necessary nuts, bolts and washers and suspending the entire assembly of pump set vertically by fixing the same supported by M.S. clamps over the top of housing pipe, binding the motor cable with each column pipes and drawing cable upto pump controller/starter point including opening out of the top cap of housing pipe of the tubewell and testing of motor both in loading as well as in unloaded condition before and after installation of the same. (The rate is inclusive of hiring charges of tools & plants.) (Colum Pipe and other accessories supplied departmentally) (b) 30 cubic metre her hour capacity electro motor pumping set. (ii) Length of pump assembly exceeding 18 metre length.

12

-

696.84

... More
Charge for jointing water proof cable with required water proof insulation and proper jointing compound including supplying the same and motor related materials complete.

12

-

42.43

... More
Supplying, fitting and fixing PVC pipes for underground work of approved make (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.). 32 mm dia pipe.

36

-

250

... More
Supplying, fitting & fixing of M.S. plate of size 20 cm x 20 cm, thickness 6 mm, make of two halves (20cm x 10 cm), placed over Housing Pipe of LDTW to rest the supporting clamps,with semi circular hole of 90 mm dia. at centre including locking arrangement between the two halves on both sides,including fitting, fixing of 25 mm dia. G.I. bend by making a hole on plate for passing submersible cable smoothly and complete in all respect.

12

-

382.84

... More
Supplying, fitting and fixing G.I pipe of TATA make with all necessary accessories, specials, viz. socket, bend, tee union, cross, melbow, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paint in any position above ground. ( No seperate payment will be made for accessories, specials.) ( h ) ( ii ) 80 mm dia. medium quality

18

-

818

... More
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20mm dia x 125 mm long galvanized bolt, double nuts, doublewashers including socketing at both ends of stranded GI (HotDip) wire by crimping sockets/ thimbles and S & F 40 mm diaGI pipe (ISI-Medium) protection (3 Mts. long) to be filled withbitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts

24

-

3146

... More
Supplying and fixing earth busbar of galvanized (Hot Dip) M.S. Flat 25 mm × 6 mm on wall having clearance of 6 mm. from wall including providing drilled holes on the busbar complete with G.I. bolts, nuts, washers spacing insulators etc. as required

5.4

-

156

... More
Connecting the equipments to earth busbar including supplying and fixing G.I. (Hot Dip) Wire of size as below on wall/floor with stapples buried inside floor/wall as required and making connection to equipments with bolts, nuts, washers, cable, lugs etc. as required and mending good damages. No. 8 SWG

120

-

9

... More
Supplying and fixing 240 Volt DP with fuse on L&N, 15/16 Amps.sheet steel Main Switchs of Havells make on Iron legs on wall

12

-

576

... More
Supplying and fixing 415 Volt DP with fuse on L&N, 32 Amps.sheet steel Main Switchs of Havells make on Iron legs on wall

12

-

1738

... More
Supplying & fitting E.I. danger board on wall 20 mm × 30 cm.(8" x 12")

24

-

85

... More
Supplying 31/2 Core 25 sq. mm aluminium armoured Cable

36

-

219

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables for 31/2 Core 25 sq. Mm

12

-

152

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 3½ core 25 sqmm cable

24

-

110

... More
Distribution wiring in 1.1 KV grade 2x 22/0.3 (1.5 sq mm) single core standard 'FR' PVC insulated and sheathed single core standard copper wire (Brand approved by EIC) in suitable size PVC casing-caping (Precision make) with 1X20/0.3 (1.5 sq mm.) single core standard 'FR' PVC insulated and sheathed copper wire for ECC, inc. necy. PVC clips, fittings etc. to light/fan/call bell points with Piano Key type switch (Anchor make) fixed on sheet metal fabricated switch board with perspex/ bakelite to cover on wall incl. necy. connection and making earthing attachment, painting the MS box and mending good the damages to building works.( PVC casing-caping and switch board both on surface ) A) average run 5 mts

24

-

577

... More
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sq mm) single core standard 'FR' PVC insulated and sheathed single core standard copper wire ((Brand approved by EIC) in suitable size PVC casing-caping (Precision make) with 1X20/0.3 (1.5 sq mm.) single core standard 'FR' PVC insulated and sheathed copper wire for ECC, inc. necy. PVC clips, fittings etc.to 5A 3 pin flush type plug socket & Piano Key type switch (Anchor make) fixed on sheet metal fabricated CRC MS switch board with perspex/ bakelite (wall maching color) top cover 3 mm thick flushed in wall by housing the board after cutting brick wall incl. necry. connection making earthing attachment, painting and mending good the damages to building works.( PVC casing-caping and plug box both on surface ) A) On Board

12

-

67

... More
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. (Meter Loop connection from 440V TPN Main Switch to Pump Controller) 3x36/0.3 (2.5 sqmm) + 2x22/0.3 (1.5 sqmm) as ECC

48

-

105

... More
Supplying, fitting & fixing 350 mm x 250 mm x 25 mm size Wooden Plank on wall (for fitting & fixing of electrial equipments as necessary on the plank).

12

-

413.01

... More
Supplying Fixing angular batten holder (Anchor) on 75 mm dia PVC round block / round bakelite on wall/ceiling.

24

-

38

... More
Supplying 230/250 Votl., 15/18 Watt LED Lamp (Havelles/Philips make). Model- LED New Adore 15W E27 WW Ball Lamp.

24

-

300

... More
Insulation testing of internal wiring of Pump House/Kiosk Box including wiring of electric Motor & other ancilary equipments by means of Megger

12

-

165.02

... More
Add extra @ 2% over PWD Electrical schedule rates as District Charge i.e, 2%

12

-

233.64

... More
Solar Module: Supply, transport, installation and commissioningof MNRE(Ministry of Renewable Energy, Govt. of India)/ IEC approved Solar Module of multicrystaline cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA)and high transmissivity 3.2mm tempered glass, framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak,with adequate provision for measurement tolerances.Modules supplied with the SPVsystem should have certificate as per IEC61215 specification or equivalent National or International standards. Modules must qualify to IEC61730 part I and part II for safety qualification testing and Salt Mist Corrosion Testing as per IEC 61701/IS 61701. and having warranty for output wattage, which should not be less1 sthuapnpl9ie0d%. at the end of 10 years and 80%at the end of 25 years.Necessary test certificate also to be supplied. For 5 HP Off-grid Solar Water Pumping System (with Submersible pump-motor set) - 5440/5525Wp with 320/325 Wp SPV Panel

70200

-

33.53

... More
Module Mounting Structure (For 2HP,3HPand 5HPSolarWater PumpingSystem): Supply, transport , installation of weather proof manualtracking structure madeof MS channels,angles and pipes etc. duly IS markedchannels,angles(IS808 ) to hold SPVModule with MS heavy duty pipes not less than CD125 mm as per IS1239and plates of IS226.Structure like Canopy supported with a RCC column is to be installedto limit land requirement with a height of placementof panel for free human movement and natural air cooling will be happening to get the maximum efficiency from the 2 modules.This structure to be designed considering all the possible loads on the solar panels and on the structure it self including wind load with basic wind velocity 150km/hr. The steel structure of Kg 120.00 suitable size is to be protected with minimum 80 micron galvanisation and provided with dual axis manual tracking arrangement three times in a day and seasonal tilting are to be provided to face the sun optimally.The weight of the Module Mounting Structure having4 Module structure of 320/325wp panels should not be lessthan 145 Kg, 6 Module structure of 320/325 wp panels should not be less than 191 Kgand 8 Module structure of 300wp panelsshould not be lessthan 263 Kg.

7200

-

120

... More
Foundation of Module Mounting Structure: Suitable and stable Reinforced Cement Concrete foundation for dual axis manual tracking SPV Module structure as per approved drawing.

36

-

19628

... More
Power conditioning unit including MPPT , Data logger and IP54 enclosure : Supply , transport , installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 600682-Environment Standard , safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine.condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc . The system should be capable to store the data at a set interval and transfer it in a pendrive through USB port . It should also monitor and save total run time, total water pumped etc . There should be provision for interfacing GPRS based data transmission.

12

-

69288

... More
Cable and Accessories : Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc. i. 4.0 Sq mm single core multi studs - 10 Mtrs (Minimum) ii. 6.0 Sq mm single core multi studs -5 Mtrs (Minimum) iii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc. For 5 Hp per structure

36

-

2529

... More
Earthing: Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe including excavation of soil for installation of Earth Electrode and filling & ramming and connecting to individual structure to earth electrode including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall / floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc complete.

60

-

1839

... More
a) Lighting System at Scheme: (with lighting Pole) : Lighting arrangement of 4 mts height with 75 mm x 50 mm G.I. pipe without lighting arm and with Solar Battery 12 V, 40 Ah (reputed brand- tubular type), Charge controller, 50 Wp solar panel, LED 11 watt 12 volt. Battery and Charge controller to be mounted on a kiosk box of thickness 14 swg, powder coated painted which is to be fitted at the bottom of the light post at man height.

12

-

16713

... More
b) Lighting System at Scheme: (Mounted on Pump House wall) : Lighting arrangement with Solar Battery 12 V, 40 Ah (reputed brand- tubular type), Charge controller, 50 Wp solar panel, LED 11 watt 12 volt. Battery and Charge controller to be mounted in a kiosk box of thickness 14 swg powder coated painted which is to be fitted at the bottom of the light post at man height fitted on wall with MS angles at pump house wall.

12

-

12218

... More
Lightning protection (Pole mounted): Lightning protection with 3" X 1.5" G.I pipe of 4 mts height with base flange in proper RCC foundation and S & F Lightning Conductor Air Terminal made of 20 mm dia 1000 mm long GI pipe (ISI Medium) having five discharge prongs of 4 SWG GI (Hot Dip) wire at top duly soldered with 7/16 stranded GI (Hot Dip) wire and 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. Earthing with 65 mm dia GI pipe (Medium) 3.0 Mts. long and 1 x 19/10 stranded GI (Hot Dip) wire (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. (Provision of one lightning protection for each structure).

12

-

7080

... More
Supply and installation of 3 phase electromotor pump set suitable for Solar operation covering 5 years warranty for the following conditions including loading, unloading, transportation etc.:-

-

-

-

... More
5 HP ISI marked 3 phase 415 V Pump-Motor set having discharge at required head as below:- Submersible Pump-motor set for LDTW ISI marked as per IS: 8034 with discharge of 7.5 Lps- 5.83 Lps at 30 mts.-40 mts. total head with cable, bends, supporting clamps, cover plate, Socket, Sluice valve, G.I. Pipe both end flanged, Nipple, Rubber Insertion, Nuts& bolts and all other accessories including transportation of Column Pipes from Deptt. Store.

12

-

28000

... More
Testing and commissioning of scheme after completion of all work

12

-

2000

... More
Comprehensive maintenance charges for 4 years beyond 1 year warranty period (which cover monthly inspection, Yearly training to WUA, to attend breakdown within 3 days and to keep the scheme in operation without lapse of time)

-

-

-

... More
For 5 HP both for Submersible & Surface pump

70200

-

5

... More
Remote monitoring for 5 years: Supply & installation of GSM/GPRS based Data Transmitter or Modem and to provide remote monitoring service to transmit the parameters to central server from the Solar pumping System with time stamp at user-defined interval and report generation at the buyer end.

12

-

21850

... More
Insurance @ 2% covering a period of 5 years.

12

-

6447.39

... More
Add GST @ 12% except supply items which are including GST as per rule

12

-

92530.69

... More
ENERGISATION PART-C: MATERIALS (WITH CODE NUMBER) : PCC Pole 9 mtr. (0110030241)

47

-

7629.32

... More
PCC Pole 8 mtr. (0110030141)

70

-

4193.25

... More
M.S. Channel 100X 50 mm. (0102010911)

0.184

-

62139.94

... More
M.S. Channel 75X40 mm 40X6mm (0102010611)

1.825

-

72682.97

... More
M.S. Angle 65x6 mm. (0101011311)

0.675

-

71884.25

... More
M.S. Angle 50x6 mm. (0101011011)

0.79

-

72682.97

... More
M.S. Flat 65x 6 mm. (0103011511)

0.77

-

79072.68

... More
M.S. Flat 50x 6 mm. (0103011211)

0.42

-

79072.68

... More
G.I. STAY SET HT (1830X20 MM) WRKG LD-7900KG (0504130432)

68

-

1035.93

... More
PORCLAIN GUY INSULATOR HT (0508040841)

68

-

33

... More
G.I.STAY WIRE 7/3.15 MM (0503050711)

0.41

-

89399.15

... More
G.I. STAY SET L.T.( 1680X16MM) WRKG LD-5100KG(0504130332)

82

-

590.68

... More
PORCELAIN GUY INSULATOR (L.T.) (0508040741)

82

-

12

... More
G.I. Stay Wire 7/2.5 mm. (0503050611)

0.42

-

92206.75

... More
G.I. Earth Spike (1833 mm X 20 mm) (0504110541)

129

-

423.32

... More
G.I. wire 5 mm (0503010811)

0.81

-

85289.45

... More
POLYMERIC DISC INSULATOR 11 KV ( 508030541)

48

-

200.38

... More
Composite H/W Fitting (0504010132)

48

-

288.34

... More
POLYMERIC COMPOSIT PIN INSULATOR 11 KV ( 508011141)

138

-

216.9

... More
ISL 11KV 200A TPGO (0304010532)

4

-

8300.62

... More
COND ACSR 50 SQ MM (0502010921)

6.1

-

42950.51

... More
LA 12 KV (5KA) FOR 11 KV (9309010841)

12

-

437.62

... More
1.1 KVPVC4C 50 SMM AL CABLE (0501017921)

0.105

-

193822.31

... More
PORCELAIN SHACKLE INSULATOR (3"X31/2") (0508040441)

356

-

17.33

... More
"D" iron clamp 3"x 3.5" (0505031541))

304

-

28.03

... More
SHACKLE STRAP BIG 185X 30 X3

52

-

29.33

... More
COND ACSR 30 SQ MM (0502010621)

13.2

-

25837.72

... More
Turn Buckle18"X5/8" (0912011441)

8

-

90.68

... More
DTR 63 KVA 11/0.433 KV 3 PH O/D (0301012541)

2

-

123887.88

... More
DTR 25 KVA 11/0.433 KV 3 PH O/D (0301011541)

1

-

68230.47

... More
DTR 16 KVA 11/0.433 KV 3 PH O/D (0301011041)

1

-

75176.26

... More
PORC CUTOUT FUSE 415/600V 100A RERBL (504122441)

21

-

568.29

... More
LABOUR: Survey of HTOH line

1.908

-

2761

... More
Survey of LTOH line

3.181

-

1714

... More
Erection of 9 mtr.Pole DP Structure with all fitting without pin insulator.

6

-

9438

... More
Erection of 9 mtr.Pole S/STN DP Structure with all fitting without pin insulator.

4

-

13169

... More
Erection of single 9 mtr.Pole with all fitting without pin insulator.

27

-

2620

... More
Erection of single 8 mtr. PCC Pole Single without Fittings without pin insulator.

70

-

1501

... More
Fixing of Bracket

70

-

605

... More
Fixing of Box Bracket

6

-

1433

... More
Extension of PCC Pole

18

-

1706.38

... More
Fixing of 11 kv Pin Insulator

138

-

63

... More
Fixing of Disc Insulator

48

-

65

... More
Fixing of LT Shakle Insulator

356

-

52

... More
Erection of H.T. GI Stay Set.

68

-

641

... More
Erection of L.T. GI Stay Set.

82

-

555

... More
Drawal of lead wire

16

-

312

... More
fixing of Cross Lessing

435

-

15

... More
Earthing complete

129

-

313

... More
Stringing & sagging ASCR 50 sq.mm

1.908

-

8289

... More
Stringing & sagging ASCR 30 sq.mm (4Wire)

3.181

-

8821

... More
Fixing of C.G. Bracket (SP)

12

-

237

... More
Fixing of C.G. Bracket (DP)

6

-

369

... More
Fixing of T.P.G.O. Isolator on S/STN DP

4

-

1193

... More
Fixing of LA

4

-

339

... More
Erection of Distribution Transformer 63 KVA

2

-

2711

... More
Erection of Distribution Transformer 25 KVA

1

-

1925

... More
Erection of Distribution Transformer 16 KVA

1

-

1885

... More
Fixing of Tee Off on SP

1

-

1510

... More
Fixing of Tee Off ON DP

2

-

1498

... More
FIXING OF MAIN SWITCH WITH CABLE AND MS HOOD FOR DC

3

-

1636

... More
FIXING OF MAIN SWITCH WITH CABLE AND MS HOOD FOR AC

1

-

1637

... More
SUNDRY @ 5% on material cost i.e, Rs.24,52,713.65x 5%

1

-

122635.68

... More
SUPERVISION CHARGE @ 15% on Material with sundry and labour i.e, Rs. (25,75,349.33+6,24,159.08) x15%

1

-

479926.26

... More
Cess @ 1% on Part-A+ Part-B+ Part-C

1

-

147958.82

... More
Add extra charge @ 18% as GST on Labour & SUPERVISION CHARGE of Part-C i.e. Rs.(6,24,159.08+4,79,926.26) x 18%

1

-

198735.36



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.