Central Mechanical Engineering Research Institute Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Central Mechanical Engineering Research Institute - CMERI Tender
Civil And Construction
Building Construction
Eprocure
Opening Date18 Dec 2023
Closing Date1 Jan 2024
Tender Amount₹ 33,41,421
Costs
EMD
₹ 66,829Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_CSIR_177903_1Bid Award Id
ViewTender No
34/79/23-24/Proj/ESDTender Authority
Central Mechanical Engineering Research Institute ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Scope of work, List of approved makes and Drawings.
Tender acceptance letter, Bank Details and undertaking (format given)
BOQ Items
Taking out doors, windows and clereystorey window shutters (steel or wood) including stacking within 50 metres lead of area beyond 3 sqm.
4
-
-
12 mm cement plaster of mix of mix 1:4( 1 cement : 4 fine sand).
35
-
-
Demolishing RCC work manually/ by mechanical means including stacking of steel bars and disposal of serviceable material within 50m lead as per direction of Engineer-in-charge
1
-
-
Demolishing brickwork manually/ by mechanical means including stacking of serviceable materials and disposal of unserviceable materials within 50m lead in cement mortar.
3.5
-
-
Dismantling asbestos/GI/profile sheet roofing including ridges, hips valleys and gutters etc and stacking within 50m lead
35
-
-
Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: Channels, angles, tees and flats
200
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
500
-
-
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
170
-
-
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Trapizoidal profiled colour coated sheet.
50
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
30
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
22
-
-
Providing and fixing bright finished brass tower bolts (barrel type) of size 200x10 mm with necessary screws etc. complete.
8
-
-
Providing and fixing chromium plated brass handles of 125 mm with necessary screws etc. complete
10
-
-
Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete
6
-
-
Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer (GODREJ/ HARDWYN MAKE OR EQUIVALENT ) with double speed adjustment with necessary accessories and screws etc. complete.
3
-
-
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
4
-
-
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 5 mm depth and 5 mm width
28
-
-
Half brick masonry with bricks of class designation 75 in superstructure above plinth upto floor V level in cement mortar 1:4 (1 cement: 4 coarse sand)
22
-
-
Centering & shuttering including strutting, propping etc & removal of form for lintels, beams, cantilevers etc.
7
-
-
Brick work with FPS bricks of class designation 75 upto plinth level in 1:6 grade (1 cement: 6 coarse sand).
2
-
-
Providing and laying in position 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level
1
-
-
Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars of grade Fe-500D or more
70
-
-
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
1.5
-
-
Providing and laying in position 1:2:4 (1 Cement : 2 Coarse Sand : 4 graded stone aggregate 20 mm nominal size) cement concrete of specified grade excluding the cost of centering and shuttering, all the work upto plinth level.
1.5
-
-
Providing and laying cement concrete 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor block, plain window sills, fillets etc. up to floor five level, excluding the cost of centreing, shuttering and finishing:
1
-
-
Providing and laying polished vitrified floor tiles 600x600 mm. (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS: 15622 of approved make in all colours and shades, laid on 20 mm. thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement & matching pigments etc. complete.
27
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Upto 16m height. (No separate payment shall be made for scaffolding).
1650
-
-
Wall painting with acrylic emulsion paint of Royale Luxury emulsion paint of Asian Paints/ Silk Luxury emulsion of Berger or equivalent product of approved brand and manufacture to give an even shade. Two or more coats on new work. Upto 16m height. (No separate payment shall be made for scaffolding).
1650
-
-
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
130
-
-
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 ltr/sqm. by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/ltr and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick.
22
-
-
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coat.
200
-
-
Providing and fixing PVC flexible waste pipe for sink and wash basin : 32 mm dia
15
-
-
Providing and fixing 10 mm thick calcium silicate board on existing ceiling grid.
25
-
-
Providing and fixing 100mm wide Vista (levelor make) or equivalent vertical blinds (dust gurd) of approved colour including labour material all complete.
160
-
-
Removing chokage of G.I., CPVC, H.C.I. or S.W. pipe of any dia ( Underground ) with split bamboo or any other suitable method as directed.
20
-
-
Removing chokage of G.I., CPVC, H.C.I. or S.W. Of any dia ( overground ) with split bamboo or any other suitable method as directed.
35
-
-
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987: 5mm thick coloured / tinted / smoke/ frosted glass.
20
-
-
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992: Single Socketed 3 Meter Length: 160 mm dia
20
-
-
Labour for fitting and fixing U.P.V.C. pipes for above ground work
including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 metre and refilling the same complete as per direction of the Engineer in-charge. (Payment will be made on centre line measurement of the total pipeline including specials. Above ground 160 mm dia.
20
-
-
Rendering the surface of walls and ceiling with white cement based water proof wall putty of approved make and brand (1.5mm thick).
450
-
-
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers: Fixed glazing.
45
-
-
Supplying, fitting and fixing 15 mm CP Pillar Cock of Code No. 5011 & Model - FLORENTINE of JAQUAR or equivalent.
5
-
-
Supplying, fitting and fixing of Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
5
-
-
Polishing only of old marble or terrazo work with oxalic acid powder using 33 gms/ sq.m. by manual labour / machine where necessary.
45
-
-
ELECTRICAL-PART
-
-
-
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate,suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable etc. as required.
3
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group: C
4
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
40
-
-
Supply and fixing of fully difused Recess mounted of size 2x2 feet, LED Troffer with microprismatic diffuser suitable for indoor space as required including all accessories for fixing in truss/ceiling with connection along with 3x1.5 sq mm FRLS PVC insulated copper conductor single core wire, testing, commissioning as required. RC380B LED36S-6500 G5 L60W60 PSU OD SG of philips or equivalent
65
-
-
Supply and Fixing of LED round/square surface mouted downlight including all accessories for fixing surface mounting in roof surface with connection alongwith 3x1.5 sq.mm FRLS PVC insulated copper conductor single core wire, testing, commissioning as required. Sleek surface Downlight SM250C LED12S-6500 PSU WH of Philips or equivalent
6
-
-
Supply and Fixing of LED round white downlighter complete including all accessories for fixing recessed mounting in false ceiling with connection alongwith 3x1.5 sq.mm FRLS PVC insulated copper conductor single core wire, testing, commissioning as required. The job inclusive of cutting of false ceiling.GreenPerform Sleek DN296B LED12S-6500 PSU WH of Philips or equivalent
26
-
-
Supply and fixing of 400 mm sweep, 230 Volt, white Aerodynamic blade and Hi-torque motor gives hi-air thrust wall mounted fan with Oscillation and speed control by pull cord system, connection , testing and commissioning etc. as required. (Wall-44 Plastic Bld-Crystal White of Orient or equivalent.)
32
-
-
Supply and fixing of of 1phase, 225mm Sweep, High speed Exhaust Fan in Exixting opening along with 3x1.5 sq mm FRLS PVC insulated copper conductor single core wire . 225 mm High -speed of Orient or equivalent.
2
-
-
Supplying and fixing FP sheet steel enclosure on surface/ recess , testing and commissioning etc. as required.Model 507793 for enclosure of Legrand or equivalent.
1
-
-
Supply and fixing of Mounting rail for TLED lamps luminaire with LED Tube 1200mm 20W T8 – 2100 lm including all accessories and along with 3x1.5 sq mm FRLS PVC insulated copper conductor single core wire connection, testing, commissioning as required. (TMC 501 P 1xT-LED 22W P3241 of Philips or equivalent.)
16
-
-
Dismantaling all the unserviceable electrical accessories, light fittings, Fans, power point, switch board, wiring, cable, conduit etc. The job inclusive of re fixing of light, fan, conseling of cable etc. as per direction of Engg.-in-Charge.
1
-
-
RAC - PART
-
-
-
Supply & Installation of 1.0TR non inverter wall mounted Split type A.C unit with BEE 3 star rated. Including copper pipes for suction & discharge lines with proper insulation and power cable as per technical requriment ( Approx. 9 ft. per machine). The A.C unit must be copper condensing coil, finally leak testing. Complete in all respect ( make Hitachi, carrier, blue star , voltas, L.G or equivalent).Complete in all respect and make it functional.The work as to be carried out as per Annexure –1.
10
-
-
Supply & Installation of 1.5TR non inverter wall mounted Split type A.C unit with BEE 3 star rated. Including copper pipes for suction & discharge lines with proper insulation and power cable as per technical requriment ( Approx. 9 ft. per machine). The A.C unit must be copper condensing coil, finally leak testing. Complete in all respect ( make Hitachi, carrier, blue star , voltas, L.G or equivalent).Complete in all respect and make it functional.The work as to be carried out as per Annexure –1.
11
-
-
Supply & Installation of 2.0 TR non inverter wall mounted Split type A.C unit with BEE 3 star rated. Including copper pipes for suction & discharge lines with proper insulation and power cable as per technical requriment ( Approx. 9 ft. per machine). The A.C unit must be copper condensing coil, finally leak testing. Complete in all respect ( make :Hitachi, carrier, blue star , voltas, L.G or equivalent).Complete in all respect and make it functional.The work as to be carried out as per Annexure –1.
3
-
-
If necessary Supplying and fixing of copper pipe for suction & discharge lines with proper insulation. Complete in all respect and make it functional.The work as to be carried out as per Annexure –1.
220
-
-
If necessary Supply and laying of suitable core 2.5 sq mm electrical cable for split type AC units (Havells, finolex or equilvant ) Complete in all respect and make it functionaland the work as to be carried out as per Annexure –1.
220
-
-
If necessary supplying and fixing brackets for mounting split AC out door unit as per technical requriment. Complete in all respect. The work as to be carried out as per Annexure –1.
24
-
-
If necessary supplying and fixing braided pipe for split AC unit as per technical requriment. Complete in all respect. The work as to be carried out as per Annexure –1.
150
-
-
Supply & re-filling R-22 refrigerant gas for Split A.C units with proper brazing / leakage arrest and finally leak tested . Complete in all respect. with 3 months warrentry and the work as to be carried out as per Annexure –1.
6
-
-
Supply and fixing split AC out door unit copper condenser coil as per technical requirement (existing size and coil rows or sample). Complete in all respect.with 3 months warrwnty and the work as to be carried out as per Annexure –1.
2
-
-
Evaluation Notes How It Works ?