Bridge And Roof Company India Limited Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Bridge And Roof Company India Limited Tender
Paints and Enamels
Eprocure
Opening Date21 Sep 2023
Closing Date13 Nov 2023
Tender Amount₹ 2,35,51,163
Costs
EMD
₹ 2,87,100Document Cost
₹ 3,540Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_BandR_772764_1Bid Award Id
ViewTender No
BANDR/HO/71144/PAINTING/ SC/NRL/SILIGURI/NIT/03Tender Authority
Bridge And Roof Company India Limited ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
eNIT_71144_Painting_Siliguri_NRL-03
BOQ Items
... More
DESIGN TEMP GROUP: -14 TO 80 (DEG C)SURFACE PREPARATION: SSPC-SP-10; 1 coat of F-9 @ 65-75µ DFT/coat, PRIMER: 1 coat of P-6 @ 40µ DFT/coat (Tie/ Mist Coat), FINISH COAT: 2 coats of F-6A/ F-6B @ 100µ DFT/coat + 1 coat of F-2 @ 40µ DFT/coat
-
-
-
... More
PIPES
-
-
-
... More
NB: .5 Inches
50
2500
50
... More
NB: .75 Inches
310
18910
61
... More
NB: 1 Inches
670
52260
78
... More
NB: 1.5 Inches
50
5600
112
... More
NB: 2 Inches
140
17080
122
... More
NB: 3 Inches
3760
676800
180
... More
NB: 4 Inches
1630
376530
231
... More
NB: 6 Inches
2975
1011500
340
... More
NB: 8 Inches
3275
1450825
443
... More
NB: 10 Inches
1185
654120
552
... More
NB: 12 Inches
3450
2252850
653
... More
NB: 14 Inches
4205
3023395
719
... More
NB: 16 Inches
3880
3189360
822
... More
NB: 18 Inches
825
763125
925
... More
NB: 24 Inches
1965
2422845
1233
... More
NB: 26 Inches
5
6680
1336
... More
NB: 28 Inches
1045
1502710
1438
... More
VALVES
-
-
-
... More
NB: 2 Inches
85
18445
217
... More
NB: 3 Inches
203
64757
319
... More
NB: 4 Inches
187
76857
411
... More
NB: 6 Inches
51
30855
605
... More
NB: 8 Inches
34
26758
787
... More
NB: 10 Inches
38
37278
981
... More
NB: 12 Inches
17
19737
1161
... More
NB: 14 Inches
26
33228
1278
... More
NB: 16 Inches
29
42340
1460
... More
NB: 18 Inches
1
1643
1643
... More
NB: 24 Inches
5
10950
2190
... More
NB: 28 Inches
5
12775
2555
... More
PAINTING OF TANKS
-
-
-
... More
PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS
-
-
-
... More
External Surfaces (except underside of bottom plate): Surface preparation to SSPC-SP-10, application of primer and paint on all external surfaces of tanks including insulated tanks i.e. external shell, wind girders, appurtenances, roof tops including top side of floating roof of open tanks as well as covered floating roof tanks, external roof supporting structure, associated structural steel works, ladders, walkways, platforms, handrails, spiral stairway, rolling ladder and track, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks as per painting system defined below and other requirements as specified in respective Engg. data sheets, stencilling tank no., capacity, name of stored product, painting Emblem as per the attached sample, including supply of metallic and non-metallic materials, primer and paint of approved quality, providing scaffolding, labour, equipment, consumables, etc. to complete the work in all respect as per applicable standard specifications, standards attached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor.
-
-
-
... More
Design Temperature range (-) 14°C to 80°C, Primer : 1 coat of F-9@ 65-75µ DFT/coat + 1coat of P-6 @ 40µ DFT/ coat, Finish Paint : 2 coats of F-6A @ 100µ DFT /coat + 1 coat of F-2 @ 40µ DFT/ coat. Inside surfaces of pontoons & inside surfaces of double decks shall be surface finished to SSPC-SP-3 & primer painted with 1 coat of F-8 @ 100µ DFT/coat + finish painted with 1 coat of F-8 @ 100µ DFT/coat.
700
457100
653
... More
External Surfaces (underside of bottom plate): Surface preparation to SSPC-SP-10, application of primer and paint on underside of bottom plate (soil side) as per painting system defined below and other requirements as specified in respective Engg. data sheets including supply of metallic and non-metallic materials, primer and paint of approved quality, labour, equipment, consumables, etc. to complete the work in all respect, as per applicable standard specifications, standards attached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor.
-
-
-
... More
Design Temperature Range: -45 °C To 80 °C Primer: 1 coat of F-7 @ 1 25u DFT/ coat Finish Paint: 2 coats of F-7@ 125u DFT/coat Remarks: F-7 should be suitable for immersion service of the products given
250
112500
450
... More
Internal Surfaces: Surface preparation to SSPC-SP-10, application of primer and paint on internal surface of bottom plate, shell full height, internal surfaces of cone/dome roof, roof structure, oil side surfaces of pontoons & deck plates and oil side surfaces of double decks, internal ladder, structural steel, internal support and internal accessories (except heating coil) as per painting system defined below and requirements as given in the respective engg. data sheets. Supply of metallic and non-metallic materials, labour, primer and paint of approved quality, equipment, consumables, etc. to complete the work in all respect, as per applicable specifications, standards attached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor.
-
-
-
... More
Design Temperature Range: -45 °C To 60 °C Primer: F6A
690
378810
549
... More
Finish Paint F6A Remarks: 1 Coat of F-6A@100micron DFT/Coat and 2 Coats of F-6A@100micron DFT/Coat
-
-
-
... More
Painting - Non FIM Items
-
-
-
... More
Supply of paints and primers, preparation of surfaces and application of primer for all type of structural steel, chequered plate, Hand railing, pipe supports etc as specified including rubdown and touch up of shop primer wherever required, providing scaffolding (if required) for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per EIL painting spec., drawings and direction of Engineer-in-Charge. Preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per EIL Specification No. 6-79-0020 (or as per Job Specification, wherever applicable).
300
1725300
5751
... More
Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 9.2 of Table 9.0 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 7.2.1 of Table 7.2 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable), for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, for OFFSITE (INLAND) areas considering environment classification as INDUSTRIAL. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.(Unit rate based on Structural steel weight). Appliacable for all type of structural steel works, chequered plates, Handraing pipes and pipe supports at all level and heights.
300
1846800
6156
... More
Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 8.1 of Table 8.0 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) for painting over the coat of shop primer & galvanisation already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE. (Unit rate based on weight of steel).
10
76500
7650
... More
Painting of A/G pipes and valves
-
-
-
... More
Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines.
-
-
-
... More
Painting of uninsulated surfaces for 'Industrial ' environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes
-
-
-
... More
Nominal Dia. 12 Inch
200
130600
653
... More
Nominal Dia. 10 Inch
1
1105
1105
... More
Nominal Dia. 6 Inch
20
7480
374
... More
Nominal Dia. 4 Inch
170
39270
231
... More
Nominal Dia. 8 Inch
300
132900
443
... More
Nominal Dia. 14 Inch
5
7190
1438
... More
Nominal Dia. 16 Inch
950
780900
822
... More
Nominal Dia. 2 Inch
15
2745
183
... More
Nominal Dia. 0.75 Inch
2
468
234
... More
Nominal Dia. 1 Inch
1
234
234
... More
Nominal Dia. 2.5 Inch
1
360
360
... More
Painting of uninsulated surfaces for 'Industrial ' environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes
-
-
-
... More
Nominal Dia. of valve 12 Inch
2
2322
1161
... More
Nominal Dia. of valve 6 Inch
5
3025
605
... More
Nominal Dia. of valve 4 Inch
50
20550
411
... More
Nominal Dia. of valve 1 Inch
6
720
120
... More
Nominal Dia. of valve 8 Inch
5
3935
787
... More
Nominal Dia. of valve 14 Inch
2
2556
1278
... More
Nominal Dia. of valve 16 Inch
10
14600
1460
... More
Nominal Dia. of valve 0.75 Inch
4
480
120
... More
"NOTE:-
THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements