Bridge And Roof Company India Limited Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Bridge And Roof Company India Limited Tender

Works
Paints and Enamels
Eprocure
Opening Date21 Sep 2023
Closing Date13 Nov 2023
Tender Amount₹ 2,35,51,163 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
DESIGN TEMP GROUP: -14 TO 80 (DEG C)SURFACE PREPARATION: SSPC-SP-10; 1 coat of F-9 @ 65-75µ DFT/coat, PRIMER: 1 coat of P-6 @ 40µ DFT/coat (Tie/ Mist Coat), FINISH COAT: 2 coats of F-6A/ F-6B @ 100µ DFT/coat + 1 coat of F-2 @ 40µ DFT/coat

-

-

-

... More
PIPES

-

-

-

... More
NB: .5 Inches

50

2500

50

... More
NB: .75 Inches

310

18910

61

... More
NB: 1 Inches

670

52260

78

... More
NB: 1.5 Inches

50

5600

112

... More
NB: 2 Inches

140

17080

122

... More
NB: 3 Inches

3760

676800

180

... More
NB: 4 Inches

1630

376530

231

... More
NB: 6 Inches

2975

1011500

340

... More
NB: 8 Inches

3275

1450825

443

... More
NB: 10 Inches

1185

654120

552

... More
NB: 12 Inches

3450

2252850

653

... More
NB: 14 Inches

4205

3023395

719

... More
NB: 16 Inches

3880

3189360

822

... More
NB: 18 Inches

825

763125

925

... More
NB: 24 Inches

1965

2422845

1233

... More
NB: 26 Inches

5

6680

1336

... More
NB: 28 Inches

1045

1502710

1438

... More
VALVES

-

-

-

... More
NB: 2 Inches

85

18445

217

... More
NB: 3 Inches

203

64757

319

... More
NB: 4 Inches

187

76857

411

... More
NB: 6 Inches

51

30855

605

... More
NB: 8 Inches

34

26758

787

... More
NB: 10 Inches

38

37278

981

... More
NB: 12 Inches

17

19737

1161

... More
NB: 14 Inches

26

33228

1278

... More
NB: 16 Inches

29

42340

1460

... More
NB: 18 Inches

1

1643

1643

... More
NB: 24 Inches

5

10950

2190

... More
NB: 28 Inches

5

12775

2555

... More
PAINTING OF TANKS

-

-

-

... More
PAINTING FOR CARBON STEEL AND LOW ALLOY STEEL TANKS

-

-

-

... More
External Surfaces (except underside of bottom plate): Surface preparation to SSPC-SP-10, application of primer and paint on all external surfaces of tanks including insulated tanks i.e. external shell, wind girders, appurtenances, roof tops including top side of floating roof of open tanks as well as covered floating roof tanks, external roof supporting structure, associated structural steel works, ladders, walkways, platforms, handrails, spiral stairway, rolling ladder and track, internal surface of shell above maximum liquid level exposed to atmosphere for open top or floating roof tanks as per painting system defined below and other requirements as specified in respective Engg. data sheets, stencilling tank no., capacity, name of stored product, painting Emblem as per the attached sample, including supply of metallic and non-metallic materials, primer and paint of approved quality, providing scaffolding, labour, equipment, consumables, etc. to complete the work in all respect as per applicable standard specifications, standards attached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor.

-

-

-

... More
Design Temperature range (-) 14°C to 80°C, Primer : 1 coat of F-9@ 65-75µ DFT/coat + 1coat of P-6 @ 40µ DFT/ coat, Finish Paint : 2 coats of F-6A @ 100µ DFT /coat + 1 coat of F-2 @ 40µ DFT/ coat. Inside surfaces of pontoons & inside surfaces of double decks shall be surface finished to SSPC-SP-3 & primer painted with 1 coat of F-8 @ 100µ DFT/coat + finish painted with 1 coat of F-8 @ 100µ DFT/coat.

700

457100

653

... More
External Surfaces (underside of bottom plate): Surface preparation to SSPC-SP-10, application of primer and paint on underside of bottom plate (soil side) as per painting system defined below and other requirements as specified in respective Engg. data sheets including supply of metallic and non-metallic materials, primer and paint of approved quality, labour, equipment, consumables, etc. to complete the work in all respect, as per applicable standard specifications, standards attached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor.

-

-

-

... More
Design Temperature Range: -45 °C To 80 °C Primer: 1 coat of F-7 @ 1 25u DFT/ coat Finish Paint: 2 coats of F-7@ 125u DFT/coat Remarks: F-7 should be suitable for immersion service of the products given

250

112500

450

... More
Internal Surfaces: Surface preparation to SSPC-SP-10, application of primer and paint on internal surface of bottom plate, shell full height, internal surfaces of cone/dome roof, roof structure, oil side surfaces of pontoons & deck plates and oil side surfaces of double decks, internal ladder, structural steel, internal support and internal accessories (except heating coil) as per painting system defined below and requirements as given in the respective engg. data sheets. Supply of metallic and non-metallic materials, labour, primer and paint of approved quality, equipment, consumables, etc. to complete the work in all respect, as per applicable specifications, standards attached elsewhere in the tender document and instructions of Engineer- in-Charge. All materials shall be supplied by Contractor.

-

-

-

... More
Design Temperature Range: -45 °C To 60 °C Primer: F6A

690

378810

549

... More
Finish Paint F6A Remarks: 1 Coat of F-6A@100micron DFT/Coat and 2 Coats of F-6A@100micron DFT/Coat

-

-

-

... More
Painting - Non FIM Items

-

-

-

... More
Supply of paints and primers, preparation of surfaces and application of primer for all type of structural steel, chequered plate, Hand railing, pipe supports etc as specified including rubdown and touch up of shop primer wherever required, providing scaffolding (if required) for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per EIL painting spec., drawings and direction of Engineer-in-Charge. Preparing the surface for painting (SSPC-SP-10) and applying pre-erection/ shop primer (1 coat of F-9 @ 65-75 micron DFT) as per EIL Specification No. 6-79-0020 (or as per Job Specification, wherever applicable).

300

1725300

5751

... More
Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 9.2 of Table 9.0 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) over the coat of shop primer already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat as per Sl. No. 7.2.1 of Table 7.2 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable), for steel structures (excluding ladders, spiral stairways & hand rails) at all location & levels, all complete as specified, for OFFSITE (INLAND) areas considering environment classification as INDUSTRIAL. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE.(Unit rate based on Structural steel weight). Appliacable for all type of structural steel works, chequered plates, Handraing pipes and pipe supports at all level and heights.

300

1846800

6156

... More
Supplying and applying COATING (Post-erection/ Field) of approved quality and shade as per Sl. No. 8.1 of Table 8.0 of EIL Specification No. 6-79-0020 (or as per Job Specifications, wherever applicable) for painting over the coat of shop primer & galvanisation already applied, including storage, surface preparation, degreasing, cleaning, drying, providing necessary arrangement for access, testing etc. including touching up of shop primer coat, for LADDERS, SPIRAL STAIRWAYS & HAND RAILS at all location & levels, all complete as specified. SUPPLY OF ALL MATERIAL IN CONTRACTOR'S SCOPE. (Unit rate based on weight of steel).

10

76500

7650

... More
Painting of A/G pipes and valves

-

-

-

... More
Supply of paints and primers, preparation of surfaces and application of primer and finish paints, identification (Line numbering), lettering, colour bands, colour coding etc. as specified including rubdown and touch up of shop primer wherever required, providing scaffolding for all heights, labour, material, tools and tackles, consumables supervision etc. to complete the work in all respects as per painting specification, drawings and direction of Engineer-in-Charge for all types of un insulated piping and insulated piping as specified including all pipes, fittings, flanges, supports, valves etc. Surface preparation by blast cleaning and application of first coat of primer (inorganic zinc silicate, F9) shall be done in fabrication yard prior to erection. The identification marks of the piping and joints shall be noted before blasting and the same shall be transferred on primed surface with Polyurethane paint (F2) or as per the instructions of Engineer-in-Charge. Notes: 1. All joints (fabrication as well as erection joints) shall be left unpainted till hydro testing. 2. No extra payment shall be made for identification (line numbering etc.) of insulated and uninsulated lines.

-

-

-

... More
Painting of uninsulated surfaces for 'Industrial ' environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following pipe sizes

-

-

-

... More
Nominal Dia. 12 Inch

200

130600

653

... More
Nominal Dia. 10 Inch

1

1105

1105

... More
Nominal Dia. 6 Inch

20

7480

374

... More
Nominal Dia. 4 Inch

170

39270

231

... More
Nominal Dia. 8 Inch

300

132900

443

... More
Nominal Dia. 14 Inch

5

7190

1438

... More
Nominal Dia. 16 Inch

950

780900

822

... More
Nominal Dia. 2 Inch

15

2745

183

... More
Nominal Dia. 0.75 Inch

2

468

234

... More
Nominal Dia. 1 Inch

1

234

234

... More
Nominal Dia. 2.5 Inch

1

360

360

... More
Painting of uninsulated surfaces for 'Industrial ' environment as per painting specification for CS piping for design temp group: -14 to 80 (Deg C) including surface preparation. For following valve sizes

-

-

-

... More
Nominal Dia. of valve 12 Inch

2

2322

1161

... More
Nominal Dia. of valve 6 Inch

5

3025

605

... More
Nominal Dia. of valve 4 Inch

50

20550

411

... More
Nominal Dia. of valve 1 Inch

6

720

120

... More
Nominal Dia. of valve 8 Inch

5

3935

787

... More
Nominal Dia. of valve 14 Inch

2

2556

1278

... More
Nominal Dia. of valve 16 Inch

10

14600

1460

... More
Nominal Dia. of valve 0.75 Inch

4

480

120

... More
"NOTE:- THE ABOVE RATE SHALL BE INCLUSIVE OF ALL TAXES & DUTIES, ROYALTIES, CESS, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES (IF ANY), OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST."

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.