Bridge And Roof Company India Limited Tender
... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Bridge And Roof Company India Limited Tender
Electrical and Electronics
Coronavirus COVID 19
Electrical Works
Eprocure
Opening Date7 Feb 2019
Closing Date16 Mar 2019
Tender Amount₹ 3,64,18,390 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 1,00,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Ac And Ventilation Works At Sagardighi Thermal Power Project Of Wbpdcl
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_BRWB_213058_1Bid Award Id
ViewTender No
BandR/HO/51149/TD/AC AND VENTILATION WORKS/01Tender Authority
Bridge And Roof Company India Limited ViewPurchaser Address
-Website
http://https://www.bridgeroof.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Technical_Specification_AC_and_VENTILATION_SYSTEMS_PART_C
eTender_Document_AC_Vebtilation_Works_WBPDCL_Murshidabad_WB
BOQ Items
... More
Central AC plant consisting of screw compressors each of min capacity 175 TR (to provide in built redundancy) type chiller units (with 50% standby) with water cooled condenser, chiller with R134a refrigerant circuit (In-built soft starter with each of the packaged chillers)
3
-
7117687
... More
25 thk. Double skin Air Handling Unit (AHU) with 6R deep cooling coil, high efficiency fan, casing, pipe & pipe fittings, filters, 3-way mixing valves, balancing valve, strainer, electrics & control, instruments with all accessories. Air Handling Units have been considered for VFD room, control rooms, office rooms, MCC rooms etc.
-
-
-
... More
Fresh Air Fan (1 no. in each AHU room) complete with filter, volume control damper and all other accessories to be installed in AHU room to meet the fresh air requirement.
6
-
47623
... More
Smoke / fume exhaust fan (1 no. in each AHU room) complete with volume control damper and all other accessories to be installed in AHU room.
6
-
63666
... More
Volume Control Dampers (VCD)
1
-
56577
... More
AHUs (each of 25 TR) for 1st Floor (AHU-1 & 2)
2
-
191929
... More
AHUs (each of 60 TR) for 2nd Floor (AHU-3 & 4)
2
-
488058
... More
AHUs (each of 60 TR) for 3rd Floor (AHU-5 & 6)
2
-
488058
... More
AHUs (each of 60 TR) for 4th Floor (AHU-7 & 8)
2
-
488058
... More
AHUs (each of 60 TR) for 5th Floor (AHU-9 & 10)
2
-
488058
... More
AHUs (each of 60 TR) for 6th Floor (AHU-11 & 12)
2
-
488058
... More
HSC Chilled Water Circulating Centrifugal pumps of app. capacity 115 m3/hr @ 40m Head with 50% standby, drive motor, base frame etc. of matching capacity, speed not exceeding 1500 RPM.
3
-
202671
... More
HSC Condensing Water Circulating Centrifugal pumps of app. capacity 160 m3/hr @ 35m Head with 50% standby, drive motor, base frame etc. of matching capacity, speed not exceeding 1500 RPM.
3
-
230243
... More
Condenser water circuit / make up wate r/ overflow & drain / equalizing water pipeline and fittings (app. Running Length = 100 m) of various sizes as per P&ID and approved drgs/docs during detailed engineering (Include from SL.5 to 5.41)
1
-
8970310
... More
Chilled water pipeline and fittings (app. Running Length = 80 m) of various sizes as per P&ID and approved drgs/docs during detailed engineering
-
-
-
... More
Valves & Strainers
-
-
-
... More
Ball valves dia 50 NB 10 Nos
-
-
-
... More
Gate valves 200 dia (Motorized) 9 Nos
-
-
-
... More
Gate valves 150 dia (Motorized) 6 Nos
-
-
-
... More
Gate valves 100 dia (Motorized) 10 Nos
-
-
-
... More
Gate valves 80 dia (Motorized) 2 Nos
-
-
-
... More
Gate valves 300 dia (Manual) 6 Nos
-
-
-
... More
Gate valves 300 dia (Manual) 6 Nos
-
-
-
... More
Gate valves 200 dia (Manual) 6 Nos
-
-
-
... More
Gate valves 150 dia (Manual) 6 Nos
-
-
-
... More
Gate valves 100 dia (Manual) 50 Nos
-
-
-
... More
Gate valves 80 dia (Manual) 10 Nos
-
-
-
... More
NRV 200 dia 3 Nos
-
-
-
... More
NRV 150 dia 3 Nos
-
-
-
... More
Balancing valve cum flow measurement valve 200 dia 3 Nos
-
-
-
... More
Balancing valve cum flow measurement valve 150 dia 3 Nos
-
-
-
... More
Balancing valve cum flow measurement valve 100 dia 10 Nos
-
-
-
... More
Balancing valve cum flow measurement valve 80 dia 3 Nos
-
-
-
... More
3 way mixing valve with modulating motor of 100 mm dia 10 Nos
-
-
-
... More
3 way mixing valve with modulating motor of 80 mm dia 02 Nos
-
-
-
... More
Pot strainer dia 300 01 Nos
-
-
-
... More
Pot strainer dia 250 01 Nos
-
-
-
... More
NOTE-
-
-
-
... More
i) Refer P&I diagram enclosed with the specification for estimation of Quantities of above mentioned items. However these quantities are tentative and may increase during the DE stage.
ii) Piping length given above is tentative and to be estimated and supplied as per site conditions.
-
-
-
... More
Mechanical Draft Cooling Tower of capacity 160 m3/hr complete with accessories with as per requirement having FRP basin, low speed fan with drive motor, drive package along with all accessories including ladder and canopy for motor.
-
-
-
... More
NOTE: The cooling tower is proposed to be placed on roof of the building.
3
-
822523
... More
Insulated chilled water expansion tank (to be placed at the highest point of the building) including sight glass, drain / makeup water valves, float valves, Chilled water piping network insulation, sand cement plastering, Aluminium cladding, thermometer, pressure gauge, flow switch etc.
1
-
580083
... More
Duct Thermal Insulation, Aluminium cladding, Acoustic insulation for the duct over a length of 5 m from AHU discharge mouth including plenum & AHU room acoustic insulation & underdeck thermal insulation.
1
-
1688329
... More
GI Ducting with supports, Aluminium SA / RA diffusers, Return air grill / linear grill, fittings, duct dampers & fire dampers, Fresh air intake arrangement with filter, damper, cowl & bird mesh etc.
1
-
3843947
... More
Strip heater, Acoustic and Thermal duct line Insulation, Thermostat & humidistat, Instruments & controls, pressure gauge, Thermometer, thermostat, humidistat, water flow Switch, HP / LP cut out switch, MCC, Electrics, etc.
1
-
160704
... More
MCC, Electrics, cabling (power, control, communication) earthing and all connected erection accessories as per scope of work
1
-
4977258
... More
Pressure & Temperature display cum transmitter units
1
-
61590
... More
Magnetic type flow meter
-
-
-
... More
Magnetic flow meter display cum transmitter units in Pipe dia 300
1
-
125327
... More
Magnetic flow meter display cum transmitter units in Pipe dia 250
1
-
103842
... More
Precision type AC:
Air cooled DX type Precision Type Air Conditioners of 2.5 TR for UPS / Server / Hub room at First Floor complete with all accessories as specified in the specification. The air conditioning shall be from Top / Bottom (Elevated Floor)
-
-
-
... More
(Note: Capacity specified for precision type AC is indicative and if capacity increases during the detailed engineering calculations, successful bidder to provide accordingly)
3
-
189781
... More
Split type Air Conditioner:
(Note: Capacity specified for split type AC is indicative and if capacity increases during the detailed engineering calculations, successful bidder to provide accordingly)
-
-
-
... More
Split air conditioner of min 1.5 TR cooling capacity (5 star rating) for First Aid room complete with all accessories.
2
-
50954
... More
Split air conditioner of min 1.5 TR cooling capacity (5 star rating) for Reception Lobby complete with all accessories.
4
-
50954
... More
Split air conditioner of min 1.5 TR cooling capacity (5 star rating) for elevator machine rooms complete with all accessories.
2
-
50954
... More
VENTILATION SYSTEMS:
-
-
-
... More
AC Plant room - Tube axial exhaust fan of 4500 m3/hr, 15mm of WG complete with fan, motor, dry panel air filter, valves, fittings, ducting, SAG and other accessories.
2
-
62305
... More
MCC Room - Tube axial exhaust fan of 2500 m3/hr, 10 mm of WG complete with fan, motor, dry panel air filter, valves, fittings, ducting, SAG and other accessories.
2
-
40821
... More
Battery Room - Bifurcated type Tube axial exhaust fan of 2500 m3/hr, 10 mm of WG complete with fan, motor, dry panel air filter, valves, fittings, ducting, SAG and other accessories.
2
-
40821
... More
Toilets & Pantry (each) shall be provided with Propeller types exhaust ventilation system of capacity 500 m3/hr, complete with louver shutter and other accessories.
15
-
5855
... More
TOTAL ESTIMATED VALUE OF WORK AGAINST ABOVE ITEMS INCLUDING ALL TAXES & DUTIES, ROYALTIES, CESS, ENVIORMENTAL & POLLUTION, FITNESS & SAFETY CLEARANCE CHARGES ( IF ANY ) OR ANY OTHER INCIDENTAL CHARGES ETC BUT EXCLUDING GST.
-
-
-
... More
[NOTE: Construction Power & Water in one point for the above work shall be provided by B&R 'Free of Cost' as per the relevent clauses of SCC ]. Land for Office, Godown, Labour hutment etc. out side of Project premises, All tools, plants, materials, equipment & man power are in the scope of the Bidder within their quoted rate.]
-
-
-
Evaluation Notes How It Works ?