Asansol Durgapur Development Authority Tender

Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Asansol Durgapur Development Authority - ADDA Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 May 2023
Closing Date5 Jun 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Distn. Wiring in 22 / 0.3 (1.5 sq mm ) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S & F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC. On Board. E20 3i + 3% District Charge.

36

9232

256.47

... More
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. Connection as required. 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC. E9, 1v + 3% District Charge.

575

56263

97.85

... More
Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. Connections with PVC Cu wire and earth continuity wire etc. E19, 18 + 3% District Charge. AC + Geyser

7

7548

1078.41

... More
Supply & fixing 240V, 16A, 3 pin modular type plug socket (Brand approved by EIC) with 16 A modular type switch , without plug top on 4 module GI modular type switch board with top cover plate flushed in wall incl. S & F switch board and cover plate and making necessary connections with PVC copper wire and earth continuity wire etc. PWDSR Nov. 2017, E18, 9b + 3% District Charge.

12

5636

469.68

... More
Supply at the work site of Green Line road lighting luminaire (complete set to ensure proper functioning) with high power LED and unique peanut lens to ensure uniform light distribution. Make: Philips (Cat. Ref. BRP409 LED130 CW M2 FG PSU GR V3, SPD /appvd. equivalent from OEM/ appvd. equivalent from Crompton / Wipro / Bajaj. Analysed Rate, Philips LED PL Effective 1st Feb. 2021.

6

48972

8162

... More
Fixing only outdoor / street light type fluorescent light fitting orMVlight fitting / LED light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes / providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S & F necy. length of 1.5 sq mm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. C3, 18 + 3% District Charge.

6

4987

831.21

... More
Supply at the work site of complete set for proper functioning of 4’ 20W (or equivalent) double LED tube with mounting rail and IP 20 protection. Make: Philips (TMC 501 P 2 x T- LED 22W P3242/ appvd. equivalent from OEM)/appvd. equivalent from Crompton/Wipro. Analysed Rate. Philips LP 01.01.2022.

23

24794

1078

... More
Fixing only fluorescent light fitting suspended 25 cm below the ceiling with 2 nos. 20mm dia EI conduit (14 SWG) supports incl. S & F EI conduit, ball socket or socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2 x 22/0.20 mm (1.5 sq. mm) flexible copper wire of 1.10 mtr. Length. C-2, 15 + 3% District Charge.

23

5069

220.42

... More
Supply at the work site of complete set for proper functioning of 4’ 20W (or equivalent) single LED tube with mounting rail and IP 20 protection. Make: Philips (TMC 501 P 1 x T- LED 22W P3241/ appvd. equivalent from OEM)/appvd. equivalent from Crompton/Wipro. Analysed Rate. Philips LP 01.01.2022.

6

4158

693

... More
Fixing only single / twin fluorescent (or LED) light fitting complete with all accessories directly on wall / ceiling by screws etc. PWDSR Nov. 2017, Pg C2, Item14a + 3% District Charge.

6

531

88.58

... More
Supply at the work site of single phase A.C 1200mm sweep heavy duty double ball bearing ceiling fan complete set with blades, canopy, fork, rubber bush, down rod etc. Make: Usha (striker)/appvd. Equivalent from Crompton /Orient/Bajaj. Analysed rate.

19

44145

2323.47

... More
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.

19

1291

67.98

... More
Supplying & fixing of box type fan clamp of 150 mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S & F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering into the box. D14, + 3% District Charge.

19

3405

179.22

... More
Supply & Fixing 240V, Modular Socket (2Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. Connections etc. E18, 10 + 3% District Charge.

19

7573

398.61

... More
Supplying & fixing of box type fan clamp of 150 mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S & F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering into the box. D14, + 3% District Charge.

2

6414

3207.33

... More
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. Length of PVC insulated wire and making connection for exhaust of following diameter: 30cm (12”) exhaust fan. C4, 28b + 3% District Charge.

2

677

338.87

... More
Supply & fixing louver shutter on wall with necessary bolts & nuts (6mm dia x 62mm long). For GI 30cm exhaust fan (12”). D14, 32b + 3% District Charge.

2

321

160.68

... More
Supplying & fixing MCB SS enclosure with IP 20/30 protection, powder coated provision for two/four pole MCB, concealed in wall / on iron frame (S & F) after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment. 4 way. D9 + 3% District Charge.

4

1301

325.48

... More
Supplying & fixing sheet metal (16 SWG) Iron Clad Bus bar chambers on angle iron frame on wall, incl. earthing attachment and painting as required. 4 bars, 415V, 315 A, 4 x 50x 10mm (Dimension of Al bars), 500 x 150mm (Dimension of sheet metal box). PWDSR Nov.’2017 Pg. D12, Item 19.a. + 3% District Charge.

0.3

1038

3460.8

... More
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall / on iron frame (S & F) after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Legrand, 8 Way, Enclosure 607717. D10/11, 14 + 3% District Charge.

2

8639

4319.82

... More
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal enclosure with IP-42/43protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc. incl. provision for earthing attachment. 8 Way Horizontal. D12, 16 + 3% District Charge.

4

2809

702.46

... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. Legrand, 6-32A SP. D6, 7 + 3% District Charge.

24

4696

195.7

... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. Legrand, 100A FP. D6, 7 + 3% District Charge.

6

42116

7019.45

... More
Supply & installation of storage type 2 Kw water heater (geyser) having 15 ltr. capacity. Item includes all requisite items like braided hot water pipes, power cord etc. for proper functioning of installed water heater. Make: Bajaj / A O Smith / Havells.

2

21000

10500

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1Mts.Long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA medium GI pipe. G1, 2a + 3% District Charge.

4

6278

1569.72

... More
Excavation of soil for installation of earth electrode and filling and ramming.G-1, 1a + 3% District Charge.

5.26

1164

221.45

... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. G2, 4c + 3% District Charge.

0.5

111

222.48

... More
Extra for treatment of soil by using salt & charcoal or coke for electrode. PWDSR Nov.2017,Pg.G-2,Item-3b + District Charges @3%

4

2187

546.93

... More
Supply at the work site of 4C x 16 sq.mm Al. conductor, XLPE insulated, armoured, overall PVC sheathed, 1.1 KV grade power cable conforming to IS: 7098(Part-1) 1988 with latest amendments. Make: Polycab / Finolex / KEI / Havells. Analysed Rate, Havells LP 10.05.2022. Analysed rate.

245

64141

261.8

... More
Supplying & fixing medium gauge 50 mm dia GI pipe (ISI-Medium) protection with necessary fittings and jointing materials as required. F 6, 11d + 3% District Charge.

24

8157

339.9

... More
Laying only cable upto 50 sq. mm through existing RCC/Hume/GI pipe/ Open masonry trench for single, 2, 3.5 & 4 core. PWDSR Nov. F1,3a + 3% District Charge.

24

1062

44.29

... More
Laying of one No. cable upto 35 sq mm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. F2,1a + 3% District Charge.

52

8676

166.86

... More
Laying of cable upto ¾ core 25 sq. mm on wall/surface incl. S & F MS saddles with earthing attachments in 10 SWG (hot dip) wire, making hole etc. as necy. Mending good damages and painting. F1, 2b + 3% district charge.

169

10444

61.8

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below: 4C x 16 sq.mm. F4, 7c + 3% District Charge.

18

2447

135.96

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials: 4C x 16 sq.mm. F5, 8b + 3% District Charge.

18

1761

97.85

... More
Supplying & fixing 415V TPN on load front operated changeover switch with sheet steel enclosure on angle iron frame on wall with nuts bolts etc. L&T, 125A, FP, 415V.D2,3a + 3% District Charge.

1

8825

8825.04

... More
G S T As applicable @ 18% on total work done value ( SL NO. - 1 to 39 )

1

96693

96693.77

... More
Labour Welfare Cess @ 1% on total work done value including G S T ( SL NO. - 1 to 40)

1

6338

6338.81



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.