Archaeological Survey Of India Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Archaeological Survey Of India - ASI Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date29 Jan 2025
Closing Soon19 Feb 2025
Tender Amount₹ 29,62,366
Costs
EMD
₹ 88,871Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_ASI_846726_1Tender No
02 / HDPM / 2024-25Tender Authority
Archaeological Survey Of India ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ≥ 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32 mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8 mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. (With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.60)
204.25
-
-
... More
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre.
886.25
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
886.25
-
-
... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.
204.25
-
-
... More
Removal of rubbish, earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge .
27.5
-
-
... More
Providing and fixing incomer panel box (incomer 01 no.-box 63A, 4 P, MCB, outer - 25 A, TP,MCB,-2 nos, 6A to 25A ,SP.MCB-18 nos, 16 way VTPN MCB DB(DD) IP-54.- 01 no.
2
-
-
... More
Providing and fixing 32A 4P MCB WITH ENCLOSURE BOX
2
-
-
... More
Providing and fixing 25 sqmm x 4C AL, AR CABLE XLPE
100
-
-
... More
Providing and fixing 63 sqmm x 4C AL, 21/2" AR CABLE END TERMINATIONS WITH DC TYPE GLANDS.
2
-
-
... More
Wiring for light /power plug with 2x4 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 no. 4 sqmm FRLS PVC insulated copper conductor single core cable for loop earthing as required (Conduit Wiring of Primary & Secondary light points for Lighting using 2 X 1.5Cu for P & N + 1 X 1.5PE from Switch Board to Lights.)
900
-
-
... More
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required.( Conduit Wiring of Main Circuit for Lighting using 2 X 2.5Cu for P & N + 1 X 2.5PE from DB to Switch Board.)
1200
-
-
... More
Wiring for light / power plug with 2x4 sq. mm FRLS pvc insulated copper conductor single core cable in surface / recessed steel conduit along with 1 no. 4 sqm mm FRLS pvc insulated copper conductor single core cable for loop earthing as required .
900
-
-
... More
Wiring for circuit / sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor , single core cable in surface / recessed steel conduit as required
850
-
-
... More
Dismantling of Electrical Room DB,Cable,Light fixture, fan, Conduit & etc.
1
-
-
... More
Supplying and fixing 12 MODULAR (16 gauge) MODULAR BASE & COVER PLATE on existing modular metal boxes etc as required
4
-
-
... More
Supplying and fixing 3 MODULAR (16 gauge) MOOULAR BASE & COVER PLATE on existing modular melal boxes etc as required .
26
-
-
... More
Supplying and fixing 4 MODULAR MODULAR BASE & COVER PLATE on existing modular metal boxes etc as required
4
-
-
... More
Supplying and fixing 6 MODULAR MODULAR BASE & COVER PLATE on existing modular metal boxes etc as required
4
-
-
... More
Supplying and fixing 8 MODULAR rectangular (stainless steel metal box) MODULAR BASE & COVER PLATE on existing modular metal boxes etc as required
4
-
-
... More
Supplying and fixing MOOULAR SWITCH: 6A on existing modular plate & switch box including connections but excluding modular plate etc. as required including all complete as per directed .
30
-
-
... More
Supplying and fixing MODULAR SWITCH : 16A on existing modular plate & switch box including connections but excluding modular plate etc. as required including all complete as per directed
16
-
-
... More
Supplying and fixing MODULAR SOCKET & PlN : 6/16 A on existing modular plate & switch box including connections but excluding modular plate etc. as required including all complete as per directed
18
-
-
... More
supplying and fixing MODULAR SOCKET 3-PlN : 6A on existing modular plate & switch box including connections but excluding modular plate etc. as required including all complete as per directed
10
-
-
... More
Supplying and lixing MODULAR blanking PLATE on existing modular plate & switch box including connections but excluding modular plate etc. as required
10
-
-
... More
Providing and fixing MODULAR AC STARTER SWITCH including all complete as per directed
4
-
-
... More
Providing and fixing 12W LED DOWN LIGHT FIXTURES INSTALLATION ONLY including all complete as per directed
128
-
-
... More
Providing and fixing 36W LED 2' X 2' LIGHT FIXTURES INSTALLATION ONLY including all complete as per directed.
48
-
-
... More
Providing and fixing 8 SWG GI WIRE FOR EARTHING CONTINUITY including all complete as per directed
120
-
-
... More
Supply & installation of 25 mm dia PVC Flexible pipe including all complete as per directed
50
-
-
... More
Supply & installation of 25 mm dia PVC MMS conduit pipe including all complete as per directed.
150
-
-
... More
Temporary Construction Power and Lighting Arrangement with manpower for maintenance as required for the working site
1
-
-
... More
Wall Cutting Charges including all complete as per directed
180
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%