Airports Authority Of India Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
Airports Authority Of India - AAI Tender
Electrical and Electronics
Eprocure
Opening Date14 Nov 2024
Closing Date9 Dec 2024
Tender Amount₹ 2,34,15,425
Costs
EMD
₹ 4,68,309Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_AAI_214505_1Tender No
AAI/BD/AGM-I/24-25/NIT/5/222Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://https://www.aai.aero/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply,installation, testing and comminssioning of High Static Ductable Indoor units of minimum 8.0 TR capacity and external static pressure VRF/VRV celing mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve,corded remote control,outer cabinet,vibration isolators,drain pipe,other necessary supports etc. suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from BMS system. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
9
-
-
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing among following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with Nitrile Rubber Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc.as applicable for the system :
-
-
-
9-11 mm dia (OD) (Soft drawn) with 19 mm thick insulation
250
-
-
12-13 mm dia (OD) (Soft drawn) mm with 19 mm thick insulation
80
-
-
14-16 mm dia (OD) (Soft drawn) with 19 mm thick insulation
300
-
-
17-20 mm dia (OD) (Hard drawn)mm with 19 mm thick insulation
350
-
-
21-23 mm dia (OD) (Hard drawn) with 19 mm thick insulation
120
-
-
24-26 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
150
-
-
27-29 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
250
-
-
30-32 mm dia (OD) (Hard drawn) with tube thickness 1.6 mm with 19 mm thick insulation
70
-
-
33-35 mm dia (OD) (Hard drawn) with tube thickness 1.6 mm with 19 mm thick insulation
30
-
-
36-39 mm dia (OD) (Hard drawn) with tube thickness 1.6 mm with 19 mm thick insulation
100
-
-
40-42 mm dia (OD) (Hard drawn) with tube thickness 1.6 mm with 19 mm thick insulation
90
-
-
43-45 mm dia (OD) (Hard drawn) with tube thickness 1.6 mm with 19 mm thick insulation
90
-
-
46-55 mm dia (OD) (Hard drawn) with tube thickness 1.6 mm with 19 mm thick insulation
150
-
-
Supply, Installation, Testing and Commissioning of Refnet Joints & Branch Distributors for Indoor & Outdoor units as applicable to the system design as per OEM recommendation.
56
-
-
Providing & fixing rigid UPVC piping complete with fittings, supports as per specifications and pre insulated with 6mm thick closed cell elastomeric nitrile rubber tubular thermal insulation.
-
-
-
25 MM Dia
350
-
-
32 MM Dia
250
-
-
Ducting
-
-
-
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per OEM standards as per approved drawings and specifications of following sheet thickness complete as required.
-
-
-
24 G (Thickness 0.63 mm sheet)
120
-
-
Grillers/Diffuser
-
-
-
Supply,installation, testing and comminssioning of grilles/diffuser as per specification and drawing.
-
-
-
Aluminium supply air jet diffuser
27
-
-
Supplying and drawing 3C x 0.75 Sqmm FRLS PVC shielded copper in the existing surface/ recessed steel/ PVC conduit as required.
2000
-
-
Supplying and drawing 3C x 1.5 sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2000
-
-
Supplying and fixing of 25 mm size of Steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
2000
-
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
500
-
-
Supply of 4 CORE 35 sq.mm. XLPE insulated and PVC sheathed FRLS aluminium conductor armoured Power Cable of 1.1KV grade, confirming to IS 7098, Part-I 1988 with up to date amendments and confirming to technical specifications.
200
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq. mm (clamped with 1mm thick saddle) on wall surface as required.
200
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
a) 4 X 35 sq. mm (32mm)
4
-
-
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
-
-
-
150 mm width X 50 mm depth X 1.6 mm thickness
350
-
-
300 mm width X 50 mm depth X 1.6 mm thickness
500
-
-
Refrigerant-410a Supply , charging & Leakage testing of refrigerant - 410a in additional copper piping circuit.
150
-
-
Lifting/lowering & shifting of ODUs & IDUs as per site requirement.
1
-
-
Supplying and fixing 12 way double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator)
3
-
-
Supplying and fixing of following ways surface/ recess mounting, Horizontal type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’/MCCB ) as required .
-
-
-
8 way (4 + 24), Double door, suitable for MCCB Incoming
1
-
-
Supplying and fixing of follwoing rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole (5 amps to 32 amps)
48
-
-
Double Pole, 63 Amp
3
-
-
Triple pole (5 amps to 32 amps)
2
-
-
Triple pole and neutral (63 Amps)
2
-
-
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
a) Blanking plate
2
-
-
Supply and fixing of 1 Mtr Air curtain along with sensor at Bagdogra Airport as per technical specification.
10
-
-
Supply and fixing of 1.2 Mtr Air curtain at Bagdogra Airport as per technical specification.
9
-
-
SITC of outdoor PTTA type LT Panel, made out of 14 SWG CRCA sheet steel double door, totally enclosed, IP-55, protection free standing, floor mounting, dust and vermin proof, compartmentalized, powder coated painting suitable for operation on 3 Phase and neutral, 415V, 50 Hz AC supply system with bus bars extensible on both sides, entire panel shall have a common Copper earth bus bar of size 25 mm x 6 mm at the rear with 2 Nos. earth stud, interconnections with suitable size of copper leads/ solid aluminium strips. (Panel shall conform to IEC 60439 & of Form-4b construction).
-
-
-
Incomer:
-
-
-
02 No. MCCB LISG type, 400 Amps, 4 pole, 35 kA (Ics=100% Icu) with adjustable setting, microprocessor release with O/C & S/C protection with simultaneous double break mechanism & total break time less than equal to 10ms with Spreader terminal of both side
-
-
-
Bus Coupler:
-
-
-
01 No. MCCB LISG type, 400 Amps, 4 pole, 35 kA (Ics=100% Icu) with adjustable setting, microprocessor release with O/C & S/C protection with simultaneous double break mechanism & total break time less than equal to 10ms with Spreader terminal of both side as Bus Coupler
-
-
-
Busbars:
-
-
-
4P aluminum bus bars of minimum 600 A capacity with heat shrinkable coloured sleeves i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 35 KA for 1 sec.
-
-
-
Instruments & accessories:
-
-
-
2 No. 96 mm x 96 mm digital type Voltmeter suitable range for 3phase,4 wire operation with LED display and selector switch backup by 3 nos of 2Amp MCB.
-
-
-
2 No.96 mm x 96 mm digital type Ammeter for 3 phase 4 wire operation with LED display and selector switch and CT's
-
-
-
2 Set of LED type phase indicating lamps (RYB) and 3 set LED type Indicating lamps for ON-OFF controlled by 2Amp MCBs .
-
-
-
4 Pole SPD's of type 2 class C with both the Incomer.
-
-
-
3 Set Rotary operating mechanism and terminal extension spreaders with door interlock for all the MCCB's.
-
-
-
Mechanical & Electrical Interlocking system for Incomer & Bus Coupler.
-
-
-
Outgoing:
-
-
-
06 Nos MCCB(Ics=100% Icu), 100 Amps, 4 Pole, min 25 kA with adjustable setting , Thermal Magnetic release shall have Variable Thermal (O/L) & Variable Magnetic (S/C) protection,including connections etc as required with LED type ON-OFF Indicating lamp controlled by 2Amp MCBs .
1
-
-
SITC of Indoor TTA type LT Panel, made out of 14 SWG CRCA sheet steel double door, totally enclosed, IP-55, protection free standing, floor mounting, dust and vermin proof, compartmentalized, powder coated painting suitable for operation on 3 Phase and neutral, 415V, 50 Hz AC supply system with bus bars extensible on both sides, entire panel shall have a common Copper earth bus bar of size 25 mm x 6 mm at the rear with 2 Nos. earth stud, interconnections with suitable size of copper leads/ solid aluminium strips. (Panel shall conform to IEC 61439 -1&2 & of Form-4b construction).
-
-
-
Incomer:
-
-
-
02 No. MCCB LISG type, 630 Amps, 4 pole, 50 kA (Ics=100% Icu) with adjustable setting, microprocessor release with O/C & S/C protection with simultaneous double break mechanism & total break time less than equal to 10ms with Spreader terminal of both side .
-
-
-
Bus Coupler:
-
-
-
01 No. MCCB, LISG type, 630 Amps, 4 pole, 50 kA (Ics=100% Icu) with adjustable setting, microprocessor release with O/C & S/C protection with simultaneous double break mechanism & total break time less than equal to 10ms with Spreader terminal of both side as Bus Coupler
-
-
-
Busbars:
-
-
-
4P aluminum bus bars of minimum 1000 A capacity with heat shrinkable coloured sleeves i/c SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 36 KA for 1 sec.
-
-
-
Instruments & accessories:
-
-
-
2 No. 96 mm x 96 mm digital type Voltmeter suitable range for 3phase,4 wire operation with LED display and selector switch backup by 3 nos of 2Amp MCB.
-
-
-
2 No.96 mm x 96 mm digital type Ammeter for 3 phase 4 wire operation with LED display and selector switch and CT's
-
-
-
2 Set of LED type phase indicating lamps (RYB) and 3 set LED type Indicating lamps for ON-OFF controlled by 2Amp MCBs .
-
-
-
4 Pole SPD's of type 2 class C with both the Incomer.
-
-
-
3 Set Rotary operating mechanism and terminal extension spreaders with door interlock for all the MCCB's.
-
-
-
Mechanical & Electrical Interlocking system for Incomer & Bus Coupler.
-
-
-
Outgoing:
-
-
-
(i) 02 Nos MCCB(Ics=100% Icu) each for 500 Amps,400Amps,250 Amps & 125 Amps each having 4 Pole, min 36 kA,(Total 08 nos of MCCB) with adjustable setting , Thermal Magnetic release shall have Variable Thermal (O/L) & Variable Magnetic (S/C) protection, including connections etc as required with LED type ON-OFF Indicating lamp controlled by 2Amp MCBs.
1
-
-
SITC of outdoor type totally enclosed double door junction box having IP-55 protection, made out of 14 SWG CRCA sheet steel ,free standing, floor mounting with angle supports, dust and vermin proof, powder coated painting includes 4P aluminum bus bars of minimum 200 A capacity with heat shrinkable coloured sleeves i/c SMC/DMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 35 KA for 1 sec. Provision of 04 nos. 4P, 63 amp MCB should there as outgoing, interconnected with bus bar with 10 sq.mm size copper leads suitable for operation on 3 Phase and neutral, 415V, 50 Hz AC supply system with 2 Nos. earth stud, etc complete as required.
4
-
-
To execute the work opening and closing of desired number of existing 2X2 mettalic false celing and cutting of false celing to fix cassete IDUs. All the false celing need to be fixed with professional civil man power as required suitable as per site requirement.
1
-
-
Supply of 3.5 core x 300 sqmm XLPE insulated and PVC sheathed aluminium conductor armoured Power Cable of 1.1KV grade, confirming to IS 7098, Part-I 1988 with up to date amendments and confirming to technical specifications.(The outer sheath shall be FRLS.)
450
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) on wall surface as required.
400
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Above 185 sq. mm and upto 400 sq. mm in the existing RCC/ HUME/DUCT/ METAL pipe as required
50
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 core x 300 sqmm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4
-
-
Supplying and drawing of 3 x 10 sq.mm size FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
100
-
-
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5C x 300 sq.mm. size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
1
-
-
Providing and fixing of 4Pole, 630A, 36 KA MCCB with adjustable setting, microprocessor release with O/C & S/C protection along with rotary handle in the existing cubicle panel boards (i/c. neessary modification) including suitable size bus bar arrangements, drilling holes in cubicle panel with providing digital KWH Meter with maximum demand load and current display RS485 module of class-0.5 accuracy with suitable range of cast resin CT including making connections etc as required. 3 Nos of LED type phase indicating lamps (RYB) controlled by 2Amp MCB should be provided in panel board compartment.
2
-
-
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
50
-
-
Providing & fixing in position 3mm thick Aluminum composite panels in external face, column / wall cladding and canopy ceiling of approved make comprising virgin polyethylene core sandwiched between two skins of 0.25mm thick. Fixing of surface cladding to masonry / concrete faces / steel structure as called for (straight/slope and curvilinear profile and shapes),including all required aluminium frame and supporting items fixed on appropriate and adequate frame work of aluminium tubular sections/round/hinges etc including all accessories and all incidental work. The cladding shall be done in accordance with the drawings, fixed to sides and faces of columns/ piers, to sills and soffits of window opening, returned over coping, to RCC / structureal steel system, etc, to line and level. The joints shall be properly sealed with approved silicon sealant to make the joints wateright and weather proof includding, fixing over aluminum frame using mechaical fasteners such as Aluminum cleats and stainless steel fasteners all complete as approved by the Engineer-in-charge. The colour of ACP will be approved by EIC. The work shall be completed as per specification and directions of Engineer-in-charge.
250
-
-
All Inclusive Comprehensive Maintenance Conrtract (AICMC) of above VRF/VRV AC System for 5 years (after defect liability period of 2 years) as per the direction of EIC complete as required.
-
-
-
Year -1 (5.37 % of SITC cost)
1
-
-
Year -2 (5.00% cumulative enhancement on Year - 1 AICMC cost)
1
-
-
Year- 3 (5.00% cumulative enhancement on Year - 2 AICMC cost)
1
-
-
Year -4 (5.00% cumulative enhancement on Year - 3 AICMC cost)
1
-
-
Year -5 (5.00% cumulative enhancement on Year - 4 AICMC cost)
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%