Uttarakhand Power Corporation Limited Tender

View complete overview of Uttarakhand UPCL Tender

Uttarakhand Power Corporation Limited - UPCL Tender

Works
Energy, Oil and Gas
Eprocure
Opening Date22 Feb 2025
Closing Date7 Mar 2025
Tender Amount₹ 2,00,94,000 
Notes
Download

Costs

Summary

71/2024-25/edc(ch) Replacement Of Bare Conductor By Insulated Covered Conductor (aaac) In 11 Kv Bara Feeder Emanating From 33/11 Kv S/s Bara

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
X arm clamp for ST Pole, SP-55 with N&B.

6

-

-

... More
Stay clamp for SP-55 with N&B.

6

-

-

... More
Stay Insulator 100x115.

13

-

-

... More
11 KV Cable Tie for Pin Insulator.

480

-

-

... More
11 KV IPC for covered conductor to cover Conductor.

210

-

-

... More
11 KV IPC for covered conductor to Bare Conductor.

105

-

-

... More
11 KV mid span jointing kit.

170

-

-

... More
11 KV composit poly disc insulator 70 KN.

150

-

-

... More
Disc fitting type 70 kn 11 KV AAAC.

150

-

-

... More
11 KV AAAC Covered conductsor Al. 59, 99 Sq.mm.

22600

-

-

... More
11 KV tension clamp with ball & IPC.

150

-

-

... More
Annexure-B (Following work as per UPCL Norms/Site Requirement /RESPO)

-

-

-

... More
Excavation of earth for stay Pit of size 0.6x0.6x1.2mtr in all type of soil including proper dressing of sides and ramming of bottom including getting out he exacavated soil and disposal of surplus excavated soil.

5.62

-

-

... More
Erection of 11 kv Stay set including digging of pit size 0.6X0.6X1.5 Mtr with stay rod 16x1800 mm, stay wire 7/8 swg with proper nozzeling with back filling of pit with CC 1:4:8 in bottom of pit in size 0.60

13

-

-

... More
Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:48 ( 1 cement : 4 graded stone 20mm nominal size 8 coarse sand) block including cost of cement,sand and stone ballast

1.4

-

-

... More
Charges of Erection of Single P.C.C. Pole8.5 Mtr. Long ( 180 kg. line including digging of pits 0.6x0.9x2.15 Mtr.& with fixing of all accessories & back filling with soil & boulder earthing complete work as per RESPO specification & as per direction of Engineer in charge.

16

-

-

... More
Erection & Grouting of STP SP-55 Single Pole including digging of pit size 0.6X0.6X1.8 M , grouting, stone pad and making kiciking block in E&B ,fixing of all accessories upto energisation..

6

-

-

... More
Painting of poles STP SP 55 with angle and channel and all steel part by one coat of Red Oxide Primer and two coats of Aluminum Paint and two strip of fluorescent alternate Red and White paint 30 Cm wide upto 1.5 Mtrs. from ground level.

95

-

-

... More
Looping & Chooping of Tree branches of route clearance

5

-

-

... More
Cartage of SP-55 from store centre to nearest road site with loading, unloading at both points. (Loading, unloading plus carriage per pole) (51 to 70 km).

6

-

-

... More
Cartage of other material by vehicle from store centre to nearest road site including loading and unloading at both ends. (21 to 50 km).

3

-

-

... More
Fixing of 11 KV 90kn tension clamp B&IPC.

150

-

-

... More
Fixing of 11 KV Mid span jointing kit.

170

-

-

... More
Fixing of 11Kv IPC for Covered to Covered.

170

-

-

... More
Fixing of 11 KV IPC for Covered to Bare Conductor.

105

-

-

... More
Grouting & Muffing of poles size 0.45cmX0.60cm radious with CC 1:3:6 (1cement:3coarse sand:6 graded stone 10mm nominal size) block size 45cm height from ground level including cost of cement, stoneand sand etc.

6

-

-

... More
Laying,Spreading, Stringing and sagging of 11KV 11KV ALS AL-59-90 equivalent 105 sqmm Covered Conductor. Line in 3-phase of the following wire as phase wire including proper sagging with binding and jumpering as per user manual and sagging chart. Workdone and installation of covered Conductor.

22000

-

-

... More
Removing of old conductor with opening of binding,jumpering,and making of bundle with carriage from pit site to JE store including loading/unloading Complete work.

18000

-

-

... More
Barck Cartage of Scrap from Site to JE Store

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.