Uttarakhand Power Corporation Limited Tender

View complete overview of Uttarakhand UPCL Tender

Uttarakhand Power Corporation Limited - UPCL Tender

Works
Civil And Construction
Eprocure
Opening Date4 Aug 2022
Closing Date18 Aug 2022
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
LT Bushing Complete rod (brass) for 630 KVA

8

-

-

... More
T/F Breather Assembly (0.5 Kg Complete)

32

-

-

... More
T/F Breather Assembly (1 Kg Complete)

32

-

-

... More
L-contact copper Metal (500 AMP)

200

-

-

... More
Cork Sheet 4'X4X6 mm

20

-

-

... More
Arcing Horn

384

-

-

... More
Empire sleeve 8 mm

100

-

-

... More
Cotton Tap

50

-

-

... More
Labour Charge: Opening of HT/LT Connections Dismounting of T/F From S/S D/P/Plangth and shifting of T/Fs upto repairing site.

-

-

-

... More
25 KVA

5

-

-

... More
63 KVA

8

-

-

... More
100 KVA

19

-

-

... More
160 KVA

3

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630 KVA

2

-

-

... More
Cartage of the following capacity transformers from site to contractor's workshop with loading and unloading at both points

-

-

-

... More
25 KVA

5

-

-

... More
63 KVA

8

-

-

... More
100 KVA

19

-

-

... More
160 KVA

3

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630 KVA

2

-

-

... More
Back cartage of the following capacity transformers from contractor's workshop to work site with loading and unloading at both points

-

-

-

... More
25 KVA

5

-

-

... More
63 KVA

8

-

-

... More
100 KVA

19

-

-

... More
160 KVA

3

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630 KVA

2

-

-

... More
Opening of with top plate cover and conserver tank of T/F 11 KV bushing complete by opening nut and bolts/or cutting welding &safe stacking at work site

-

-

-

... More
25 KVA

5

-

-

... More
63 KVA

8

-

-

... More
100 KVA

19

-

-

... More
160 KVA

3

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630 KVA

2

-

-

... More
Draining of T/F Oil from the tank of T/F & collecting in drums including proper & safe stacking at work site including labour and T&P required

-

-

-

... More
25 KVA

5

-

-

... More
63 KVA

8

-

-

... More
100 KVA

19

-

-

... More
160 KVA

3

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630 KVA

2

-

-

... More
Opening of LT bushing from inside and outside of T/F opening of clamps of core assembly and taking out the core /winding assembling out of T/F tank including proper and safe stacking at work site.

-

-

-

... More
25 KVA

5

-

-

... More
63 KVA

8

-

-

... More
100 KVA

19

-

-

... More
160 KVA

3

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630 KVA

2

-

-

... More
Repaing of HT connection leads by jointing with soldering etc. with providiong empire sleeve and proper taping encluding replacements of carbonised bushing and replacement of old packing with new rubbersied cork sheet pakcing work complete in all respect.

-

-

-

... More
25 KVA

5

-

-

... More
63 KVA

8

-

-

... More
100 KVA

19

-

-

... More
160 KVA

3

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630 KVA

2

-

-

... More
Repairing of carbonised /burned LT side connecting strips by way of soldering /tightening with bolts and nut with providing empire sleeve and proper tappling of leads of all the three phase one Neutral of LT side alongwith replacement carbonised /damage bushing &replacement of old core winding assembling to remove mousture contents from core stamping including Labour and T&P required

-

-

-

... More
25 KVA

5

-

-

... More
63 KVA

8

-

-

... More
100 KVA

19

-

-

... More
160 KVA

3

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630 KVA

2

-

-

... More
Repairing of T/F tank after removing sludege deposit from the bottom of the tank and cleaning of core/winding addembling with T/F oil complete work including labour and T&P Required

-

-

-

... More
25 KVA

5

-

-

... More
63 KVA

8

-

-

... More
100 KVA

19

-

-

... More
160 KVA

3

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630 KVA

2

-

-

... More
Housing of core/winding assembling inside the T/F tank fixing of tighting clamps with core asembly making LT Connection with LT bushing & necessary taping of leads etc complete work including labour & T&P repqired.

-

-

-

... More
25 KVA

5

-

-

... More
63 KVA

8

-

-

... More
100 KVA

19

-

-

... More
160 KVA

3

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630 KVA

2

-

-

... More
Providing and fixing on the tape changer specification as per sample and connection with the coils.

-

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630 KVA

2

-

-

... More
Placing of conservator tank with top plate cover of T/F 11 KV bushing providing fresh rubberised cork sheet pakcing tighting with the help of nut&bolts washer/by way of welding top plate with T/F tank including labour and T&P required.

-

-

-

... More
25 KVA

5

-

-

... More
63 KVA

8

-

-

... More
100 KVA

19

-

-

... More
160 KVA

3

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630 KVA

2

-

-

... More
Fitting & tapping up T/F oil in T/F tank properly and complete testing of T/F by meegar results and open and short circuit

-

-

-

... More
25 KVA

5

-

-

... More
63 KVA

8

-

-

... More
100 KVA

19

-

-

... More
160 KVA

3

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630 KVA

2

-

-

... More
Cleaing of breather assembly including replacement of old packing and silica Gel with new Silica Gel including with babour and T&P required

-

-

-

... More
25 KVA

5

-

-

... More
63 KVA

8

-

-

... More
100 KVA

19

-

-

... More
160 KVA

3

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630 KVA

2

-

-

... More
Installtion/Mounting of new transformer on plith pole structure and fixing of channel /angle etc. and making all connections of HT< side including providing and fixing new lugs and its complete commissioning.

-

-

-

... More
25 KVA

5

-

-

... More
63 KVA

8

-

-

... More
100 KVA

19

-

-

... More
160 KVA

3

-

-

... More
250 KVA

12

-

-

... More
400 KVA

10

-

-

... More
500 KVA

5

-

-

... More
630KVA

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.