Uttarakhand Power Corporation Limited Tender
View complete overview of Uttarakhand UPCL Tender
Uttarakhand Power Corporation Limited - UPCL Tender
Eprocure
Opening Date18 Jun 2024
Closing Date9 Jul 2024
Tender Amount₹ 29,11,000
Costs
EMD
₹ 75,000Document Cost
₹ 2,360Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UPCL3_72421_1Bid Award Id
ViewTender No
06/2024-25/EDC(CH)Tender Authority
Uttarakhand Power Corporation Limited ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
LT Bushing rod for 500 KVA T/F
8
-
-
LT Bushing Rod (Brass) for 250-400 KVA
80
-
-
Cotton Tape
50
-
-
Rub Corck sheet 2x3x5mm
20
-
-
Empire Sleeve 8mm
100
-
-
L-Contract Copper matel
200
-
-
Breather Assembly 0.5Kg.
32
-
-
Breather Assembly 1 Kg.
32
-
-
Annexure-B (Work Portation)
-
-
-
Opening of HT/LT connection, dismounting of T/F from Sub Station double pole/ plinght and shifting of transformer upto repairing site.
-
-
-
25 KVA DTR
28
-
-
63 KVA DTR
22
-
-
100 KVA DTR
23
-
-
160 KVA DTR
1
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Cartage of the following capacity transformers from site to contractor's workshop with loading and unloading at both points.
-
-
-
25 KVA DTR
28
-
-
63 KVA DTR
22
-
-
100 KVA DTR
23
-
-
160 KVA DTR
1
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Back cartage of the following capacity transformers from contractor's workshop to work site with loading and unloading at both points.
-
-
-
25 KVA DTR
28
-
-
63 KVA DTR
22
-
-
100 KVA DTR
23
-
-
160 KVA DTR
1
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Opening of top plate cover and conserver tank of T/F 11 KV bushing complete by opening nut & bolt or cutting welding & safe stacking at work site.
-
-
-
25 KVA DTR
28
-
-
63 KVA DTR
22
-
-
100 KVA DTR
23
-
-
160 KVA DTR
1
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Draining out of Transformer oil from the tank of T/F & Collecting in drums including proper & safe stacking at work site including labour & T&P required.
-
-
-
25 KVA DTR
28
-
-
63 KVA DTR
22
-
-
100 KVA DTR
23
-
-
160 KVA DTR
1
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Opening of LT bushing from inside and outside, Clamps of core assembly & taking out the core/ winding assembling out of T/F tank including proper and safe stacking at work site.
-
-
-
25 KVA DTR
28
-
-
63 KVA DTR
22
-
-
100 KVA DTR
23
-
-
160 KVA DTR
1
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Repairing of HT connection leads by jointing with soldering etc. with providing empire sleeve & proper taping encluding replacement of carbonised bushing & replacement of old packing with new rubbersied cork sheet packing work complete in all respect.
-
-
-
25 KVA DTR
28
-
-
63 KVA DTR
22
-
-
100 KVA DTR
23
-
-
160 KVA DTR
1
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Repairing of Carboinised/ burned LT side connecting strips by way of soldering/ tightening with bolt & nut with providing empire sleeve & proper tapping of leads of all the three phase on Neutral of LT side alongwith replacement carboinsed/ damage bushing & replacement of old packing with new Rubberised cork sheet packing & short circuit the core/ winding assembling to remove moisture contents from core stamping including labour & T&P required.
-
-
-
25 KVA DTR
28
-
-
63 KVA DTR
22
-
-
100 KVA DTR
23
-
-
160 KVA DTR
1
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Repairing of T/F tank after removing sludge deposit from the bottom of the tank & cleaning of core/ winding assembling with T/F Oil complete work including labour & T&P required.
-
-
-
25 KVA DTR
28
-
-
63 KVA DTR
22
-
-
100 KVA DTR
23
-
-
160 KVA DTR
1
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Housing of core/ winding assembling inside the T/F tank fixing of tighting clamps with core assembly making LT Connection with LT Bushing & necessary taping of leads etc. complete work including labour & T&P required.
-
-
-
25 KVA DTR
28
-
-
63 KVA DTR
22
-
-
100 KVA DTR
23
-
-
160 KVA DTR
1
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Providing and fixing on the tape changer specification as per sample & connection with the coils.
-
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Opening conservator tank with top plate cover of T/F 11 KV bushing providing fresh rubberised cork sheet packing & tighting with the help of Nut & Bolts & waher / by way of welding tip plate with T/F tank including labour & T&P required.
-
-
-
25 KVA DTR
28
-
-
63 KVA DTR
22
-
-
100 KVA DTR
23
-
-
160 KVA DTR
1
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Fitting & tapping of T/F oil in T/F tank properly & complete testign of T/F by meeger result & open & short Circuit test result.
-
-
-
25 KVA DTR
28
-
-
63 KVA DTR
22
-
-
100 KVA DTR
23
-
-
160 KVA DTR
1
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Cleaing of breather assembly including replacement of old packing & silica gel with new silica get including with labour & T&P required.
-
-
-
25 KVA DTR
28
-
-
63 KVA DTR
22
-
-
100 KVA DTR
23
-
-
160 KVA DTR
1
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Installation / mounting of new transformer on plinth pole structure and fixing of channel / angle etc. and making all connection s of HT & LT side including providing & fixing new lugs and its complete commissioning.
-
-
-
25 KVA DTR
28
-
-
63 KVA DTR
22
-
-
100 KVA DTR
23
-
-
160 KVA DTR
1
-
-
250 KVA DTR
9
-
-
400 KVA DTR
8
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements