Uttarakhand Jal Sansthan Tender
View complete overview of Uttarakhand UJS Tender
Uttarakhand Jal Sansthan - UJS Tender
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date20 Feb 2024
Closing Date26 Feb 2024
Tender AmountRefer Documents
Costs
EMD
₹ 3,76,000Document Cost
₹ 4,720Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UKJS_69958_2Bid Award Id
ViewTender No
1672/E-Tender notice/ 2023-24 Date.17.02.2024Tender Authority
Uttarakhand Jal Sansthan ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
666.69
-
-
Excavation in ordinary soil (loam, clay, sand) for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches.
2273.25
-
-
Providing, Lowering into trenches with true to alignment. Laying & Jointing of full Length of HDPE Pipes of specified grade as per IS:4984-1995 and specifications with testing of pipe line including supply of jointing materials.(PE-100 Grade, PN-8(8.0 Kg/Cm2)
Normal Pressure (PN) in 8.0 Kg/Cm2
63mm PN8
6630.6
-
-
75 mm PN8
215
-
-
90 mm PN8
1462.6
-
-
110 mm PN8
46
-
-
160 mm PN8
2
-
-
200 mm PN8
584.3
-
-
Providing of all materials, Carting from site store to site of work, Laying & Jointing of G.I screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc.) in trenches with its cutting, threading and testing of pipe line etc complete. 15 mmdia
6916
-
-
Providing of all materials, Carting from site store to site of work, Lowering into trenches with true to alignment, Laying of MS ERW Pipes grade Yet 210, Jointing by electric welding process with proper grade of electrodes suitable for jointing of water supply pipe lines (Adore, L&T or equivalent electrodes) by cutting of pipes and making required bends by welding, completion of work with testing of pipe line etc. complete.
150 mm dia (4.8 mm thick)
30
-
-
200 mm dia (4.8 mm thick)
270
-
-
250 mm dia (4.8 mm thick)
850
-
-
Supplying and fixing of following sizes of Sluice/Gate valves including carting the same up to site of work and fixing the same in water supply lines including cost of valves, specials, labor and T&P complete in all respect but excluding the cost of earth work and construction of chamber. C.I. D/F Sluice Valves Confirming to IS: 14846-2000 Pressure PN 1.6
50 mm dia
6
-
-
65 mm dia
10
-
-
80 mm dia
4
-
-
100 mm dia
3
-
-
125 mm dia
3
-
-
150 mm dia
3
-
-
200 mm dia
2
-
-
250 mm dia
1
-
-
Providing & Fixing of Woltman type Bulk Water Meter inline type, flange end with integral mounted display and all necessary fittings etc complete.
2
-
-
Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4(1 cement: 4 coarse sand ) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand : 4"graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 (1 cement: 5 fine sand:10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3(1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design
16
-
-
Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4(1 cement: 4 coarse sand ) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand : 4"graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 (1 cement: 5 fine sand:10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3(1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design
7
-
-
Constructing masonry Chamber 120x120x100 cm, inside with 75 class designation brick work in cement mortar 1:4(1 cement: 4 coarse sand ) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand : 4"graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 (1 cement: 5 fine sand:10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3(1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design
11
-
-
Providing and making House service connection from water supply distribution pipe line etc. complete
787
-
-
Supply of all labour, material required for restoring of existing house connection which might be damaged during excavation and also shifting all existing connection to new water supply system from existing water supply system complete as per unit estimate and directed by engineer in-charge. 15 mm size water connections.
Ferrule Connection (labour cost)
89
-
-
Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main 15 mm nominal bore
89
-
-
RCC OHT Repairing work
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge decketc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shallcarry guarantee for 10 years against any leakage.
For vertical surface two coats @ 0.70 kg per sqm
167.56
-
-
For horizontal surface one coat @1.10 kg per sqm.
153
-
-
Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.
139.26
-
-
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
109.89
-
-
Removing dry or oil bound distemper, water proofing cement paintand the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
5.73
-
-
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work
115.97
-
-
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
86.6
-
-
12 mm cement plaster finished with a floating coat of neat cement of,mix :1:4 (1 cement: 4 coarse sand)
57.36
-
-
Supply & applying of water based bio-degradable epoxy polymide chemical on MS flange for repairing of water leakage including all labour material T&P etc. complete as per direction of Engineer-in-Charge.
Repairing of OHT column pipe joints with pipe joints sealents upto 10 to 20 feet height
4
-
-
Repairing of OHT column pipe joints with pipe joints sealents upto 20 to 30 feet height
4
-
-
Repairing of OHT column pipe joints with pipe joints sealents upto 30 to 40 feet height
4
-
-
Repairing of OHT column pipe joints with pipe joints sealents upto 40 to 50 feet height
8
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
549.07
-
-
Supply and installation of Water level indicator (II level) including one set of sensor with its holding parts, 54 meter sensor cable armued with steel wire.
1
-
-
Fire Hydrant work
Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement: 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design
1
-
-
P/F fire Hydrant valve confirming to is: 5290 (flanged) in position including all material, labour T&P etc Complete
80 mm dia
1
-
-
Electrical and mechanical works
Supply of energy efficient submersible pumpsets of various duty parameters, as per IS 8034 - 2002 and IS 9283 - 1995 with latest amendments
Pump of 1000 LPM discharge at 50 m head
1
-
-
Pump of 1000 LPM discharge at 50 m head
1
-
-
Supply, installation, testing and commissioning of three phase Electronic Automatic Voltage Stabiliser suitable for unbalanced voltage and unbalance load including fixing of proper size copper lugs on input and output cables on both ends at different sites on turnkey basis including five year cost free maintenance. Input voltage 280V/460V/240V(Single phase) Servo Voltage Stabilizers (50KVA)
1
-
-
Supply of chain pully block having capacity 3 Ton with 6 meter chain.
1
-
-
Supply of main switch box 200 Amp.
1
-
-
Supply of Rubber Insulation sheet 1 Mtr.x2Mtrx0.025Mtr.
1
-
-
Providing and fixing of Chlorinator Dozer (Dosing pump) pressure 10 kg/cm2
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements