Uttarakhand Jal Sansthan Tender
View complete overview of Uttarakhand UJS Tender
Uttarakhand Jal Sansthan - UJS Tender
Civil And Construction
Eprocure
Opening Date17 Nov 2022
Closing Date2 Dec 2022
Tender Amount₹ 1,27,34,391 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 2,53,200Document Cost
₹ 4,720Tender Fee
Refer Documents
Summary
Gohari Mafi Water Supply Scheme
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_UKJS_51821_6Bid Award Id
ViewTender No
3552/E-tender notice/2022-23 Date 14-11-2022Tender Authority
Uttarakhand Jal Sansthan ViewPurchaser Address
-Website
http://http://ujs.uk.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
IOT Based Water Monitoring System including all Sensors (Residual Chlorine sensors,Pressure sensor) ,Mechanical flow meter & all related items.
1
-
-
Supply & Installation of elecronically controlled, electrically actuated,diaphragm operated, chemical metering pump, wall mounting suitable for delivering up to 6 litres of chemical solution/sodium hypochlorite solution per hour under maximum delivery pressure up to 6.0 KG/cm2 and suction lift not less than 1.5 meter with accessories.
1
-
-
Industrial Grade electrification of Pump House and Pump House Camps with Copper wiring in UPVC conduit.
1
-
-
Pumping Plant accessories for tube wells including earthing material, piping & valves, gauges, required tools for maintenance, chain pully block, 2 ton capacity, rubber resistance sheet, testing of plant at site and painting entire insttlalation etc. as per unit estimate complete. - Supply, testing, tagging, terminating and jointing of 3 core flat cable with bare bunched copper conductor insulated with PVC and sheathed with PVC for submersible pump motors with Voltage grade upto 1100 V generally confirming to IS 694-2010 with latest amendments of the following size. -35 Sqmm 3 Core
100
-
-
SITC of Main Incomer panel comprising of TPN MCCB of rating suitable of following rating with Three phase volt meter, Amp. Meter, CT, Mains indicating lamps etc. - 250 Amp
1
-
-
Auto Phase correction unit for following ratings - 110 Amp
1
-
-
Supply, testing, tagging, terminating and jointing of XLPE insulated PVC sheathed cable of 1.1 KV grade with Aluminium conductors armoured as per IS 7098-I including terminations at both ends, testing, commissioning at site as per spcifications, complete in all respects - 70 Sqmm
20
-
-
Earthing of complete electrical equipment (GI Earth strip, GI earth plate etc. including digging of pit & Complete earthing in all respect as per IE rule, IS: 3043, including supplying and laying 25x5mm GI Strip 0.5 meter below ground with standard accessories.
1
-
-
415 V, A' class, non-skid, high voltage insulation synthetic mat mate from electrometric polymer material, 1000mm wide, 2.0 mm thick, Dielectric strength 3300V for 1 minute, fire retardant, no adverse effect of transformer oil , diesel, acis, alkali, High Tensile and Elongation properties, good mechanical strength to withstand load and movement of breaker trolley, as per IS 15652 with latest amendments.
1
-
-
Shock treatment chart, duly laminated in Hindi (Local)- 1NO. And English language- 1N0.
1
-
-
First Aid Box with all essential medicines including wall mounted bracket
1
-
-
415 V, Aluminium, anodised Danger caution plate in Hindi (local) and English languages with the sign of skull and bones in signal red colour on front side, as per IS 2551 with latest amendments.
1
-
-
CO2 type, portable Fire extinguishers, of size 5 Kg each, manufactured from CRCA sheets in all welded construction, body coated with glossy corrosion resistant epoxy powder coating, with inbuilt water proof pressure guage, with wall bracket, as per IS 2190 and IS 13849 with latest amendments.
1
-
-
Supply of jointing materials such as lugs, Tapes etc.
1
-
-
Supply of main Piping and Valves compriging
1
-
-
Supply of 100 mm dial Pressure Gauge with control cock & fitting of range 0-10 Kg/Sqcm -01 no.
1
-
-
Supply of following Tools required for maintenance of Pumping plants.
1
-
-
Installation & Commisioning of Pumping Plants with accessories in side the Pump House but without Civil Works Such as laying of foundation,Cable Trench etc.
1
-
-
Testing of Pumping Plants at Site
1
-
-
Painting of entire installation with 02 coats of anti corrosion bituminous black paint over 1 primer coat Super Enamal Paint as per direction of Engineer Incharge
1
-
-
Civil Work - Supply of all Materials, Labours, T&P etc.repair of existing pump house including cost of all Labour & Fittings all complete.
1
-
-
Provide all Materials, Labour, T & P etc and Construct Boundary Wall 2.00 m Height & Iron Grill Over it, All Round the Tube Well & O.H.T Campus to prevent the approach of unauthorised souls.
80
-
-
Provide all Materials, Labour, T & P etc and construct 3.60 m Wide Entrance Gate with Gate Pillars for controlling approach to the area.
1
-
-
Supplying of DI Valves Including Carting the same upto the site of work as per engineering norms (with cap) complete with bolts, nuts, rubber insertions etc. anywhere in uttarakhand. - D.I. Sluice/ Gate Valve - Pressure PN 1.0 - 100 mm dia
2
-
-
Installation, testing and commissioning of DI Valves as per engineering norms anywhere in uttarakhand. - D.I. Sluice/ Gate Valve - Pressure PN 1.0 - 100 mm dia
2
-
-
Supplying of Non Return Valves Including Carting the same upto the site of workas per engineering norms anywhere in uttarakhand. - D.I. Non Return Valve - Pressure PN 1.0 - 100 mm dia
1
-
-
Installation, testing and commissioning of Non Return Valves as per engineering norms anywhere in uttarakhand. - D.I. Non Return Valve - Pressure PN 1.0 - 100 mm dia
1
-
-
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. For different types of valves.
2
-
-
Supply of dry dial,Woltman type,Magnetically coupled class-B tamper proof Bulk Water Meters with removable mechanism ,megnetic drive,hermetically scaled ,pre-equipped for remote reading as per IS:2373-1981 and ISO:4064 standard with EEC/MID certification mark shall be with protection class of IP68 for wireless AMR water meter with guarantee/warranty of following sizes along with strainer.- At Source - 100 mm dia
1
-
-
Additional rates for staging per meter height beyond 12 m height including cost of all material, labour,shuttering, scaffolding T&P complete for following capacity ( in kiloliters ) Over Head Tanks (Additional 3 metre Staging) - Leackege repair of existing OHT
1
-
-
3.0 Distribution Network & Related Components - For Pipe Laying - Dismantling of flexible pavements and disposal ofdismantled materialsupto alead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specification Clause 202 (Considering 30%)
140.82
-
-
Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately (Considering 30%)
158.49
-
-
Excavation in Pipe Line TrenchesExcavation in ordinary soil (loam, clay, sand) for foundation including lift up to 1.5M and lead up to 30M filling waterring and ramming of Excavated the earth in to the trenches or into the sides between foundation trenches or in to the plinth (75% of Total Quantity)
4016.65
-
-
Excavation in soil mixed with shingle bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling,waterring and ramming of Excavated earth in the trenches.(25% of Total Quantity)
1338.35
-
-
Providing of all materials, Carting from site store to site of work, Laying & Jointing of G.I screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc) in trenches with its cutting, threading and testing of pipe line etc complete.G.I. PIPE CONFORMING TO IS : 1239(PART-1) Medium Duty (Class 'B')-15 mm dia
5630
-
-
HDPE pipe for water supply conforiming to IS:4984-1995 - Proving of all materials, carting from site store to site of work, lowering into trenches with true to alignment, Laying & Jointing of full lengths of HDPE pipes, completion of work with testing of pipe line including supply of Jointing materials & specials. - PE-100, Normal Pressure(PN)-10 in 10 kg/cm2 - 63 mm dia
5800
-
-
75 mm dia
3174
-
-
90 mm dia
1052
-
-
110mm dia
1101
-
-
D.I. pipe conforiming to IS:8329/2000 - Proving of all materials, carting from site store to site of work, lowering into trenches with true to alignment, Laying & Jointing of full length S&S Centrifugally Cast (Spun) Ductile Iron Pipes by overlap fusion joint including supply of 'EPDM' rubber gaskets conforming to IS:5382-1985 with testing of pipe line complete. - D.I. K-7 Pipe - 150 mm dia pipe
608
-
-
Weight of DI Pipe as per IS 8329:1994 - DI K-7 - PE-100, Normal Pressure(PN)-10 in 10 kg/cm2 - Providing and laying D.I. specials of class K-12 suitable for push-on jointing as per IS: 9523-2000 (5% of DI Pipe weight)
6.36
-
-
Supplying of DI Valves Including Carting the same upto the site of work as per engineering norms (with cap) complete with bolts, nuts, rubber insertions etc. anywhere in uttarakhand. - D.I. Sluice/ Gate Valve - Pressure PN 1.0 - 65 mm dia
1
-
-
80 mm dia
2
-
-
100 mm dia
2
-
-
Installation, testing and commissioning of Sluice valve as per engineering norms anywhere in uttarakhand. - D.I. Sluice/ Gate Valve - Pressure PN 1.0 - 65 mm dia
1
-
-
80 mm dia
1
-
-
100 mm dia
2
-
-
Supplying of Air Valves as per engineering norms of approved quality with bolts, nuts, rubber insertions etc. complete anywhere in uttarakhand - D.I. Air Valve along with Isolating valve - 80 mm Diameter
2
-
-
Installation, testing and commissioning of Air Valves as per engineering norms anywhere in uttarakhand. - D.I. Air Valve along with Isolating valve - 80 mm Diameter
2
-
-
Supplying and Fixing of Fire Hydrant Valve IS 5290 (Flanged) Including carting the same upto site of work and fixing the same and water supply line Including the cost of valves,specials,labour and T&P Complete in all respect. - 80 mm diameter
2
-
-
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. For different types of valves.
4
-
-
Supply,Installation,Testing and Commissioning of Full Bore Electromagnetic Flow Meter for Lines of followoing Sizes Comprising of Flow Tube Sensor with Transmitter cum Display unit and facility to provide data communication signal over Modbus 485 Port Pulse output and 4-20mA Signal output with Flanges, Clamps etc - At Outlet of OHT - 150 mm
1
-
-
Providing and making house service connections from water supply distribution GI pipe line upto water meter chamber inside the property using GI pipe including supply and fixing of electrofussion saddle ,brass ferrules elbow, ball valve etc complete with earthwork, road cutting with restoration works
20
-
-
Providing and making house service connections from water supply distribution GI pipe line upto water meter chamber inside the property using GI pipe including supply and fixing of electrofussion saddle ,brass ferrules elbow, ball valve etc complete with earthwork, road cutting with restoration works
563
-
-
Construction of Un-reinforced, Cement concrete pavement, thickness as per design, over a prepeared sub base with 43 grade cement or any other type PCC Grade M-30, coarse and fine aggregates conforming to IS: 383,maximum size ofcoarse aggregate notexceeding 25 mm,mixed in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (Steel channel, laying and fixing of wedges, steel plates including levelling the formwork and laying and fixing of 125 micron thick polythene film, as per drawing), spreading the concrete with shovels, rakes, compacted using needle, and plate vibrators, finished in continuous operation and curing of concrete slabs for 14 days, using curing compound where specified and water finishing to lines and grade as per drawings and technical specifications.
158.49
-
-
Operation & Maintenance (3 Months) & Pipe Testing - Operation & Maintenance Cost for Trail and Testing of Pipes.
3
-
-
Testing of Pipes (G.I ,HDPE & D.I) which includes a)Parameters(Physical & Chemical)
b)Tensile Sterngth Properties
Note: Additional details were shown in attatched Quotation
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements