Uttarakhand Cooperative Dairy Federation Limited Tender
View complete overview of Uttarakhand UCDF Tender
Uttarakhand Cooperative Dairy Federation Limited - UCDF Tender
Civil And Construction
Building Construction
Eprocure
Opening Date25 May 2023
Closing Date7 Jun 2023
Tender AmountRefer Documents
Costs
EMD
₹ 2,40,000Document Cost
₹ 4,720Tender Fee
Refer Documents
Summary
Construction Of Central Dairy Lab Building At Haldwani,
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_UCDF_59018_1Bid Award Id
ViewTender No
04(1-6)-1/UCDF/Tender/2023-24, Date-24.05.2023Tender Authority
Uttarakhand Cooperative Dairy Federation Limited ViewPurchaser Address
-Website
http://https://ucdfaanchal.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and filling in plinth with Jamuna sand under floors, including, watering, ramming, consolidating and dressing complete. ( Local Sand)
558
-
-
Diluting and injecting chemical emulsion (Chlorpyriphos/Lindane E.C. 20% with 1% concentration), at the rate of one litre per hole at 300 mm c/c to all the horizontal and vertical surfaces of the excavations made for the foundation of the building, soil under floors, apron, back fill material and along all the faces of the walls for PRE-CONSTRUCTIONAL anti-termite treatment (including the cost of chemical emulsion) as per IS:6313 Part-II. Plinth area of Building shall be measured for Payment.
558
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
114
-
-
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments,pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20
mm nominal size)
18
-
-
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
88
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
8
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
122
-
-
Centring and shuttering including strutting,propping etc. and removal of form for Centring and shuttering including strutting,ropping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
46
-
-
Centring and shuttering including Strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform.
646
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
598
-
-
Columns, Pillars, Piers, Abutments, Posts and Struts.Column
163
-
-
Reinforcement for R.C.C. work including Straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars.
27318
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
168
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
126
-
-
Half brick masonry with common burnt clay F.P.S.(non modular) bricksof class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
556.2
-
-
Half brick masonry with common burnt clay F.P.S.(non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand)
18
-
-
15 mm cement plaster on rough side of single or half brick wall of mix 1: 6 (1 cement: 6 fine sand) .
394
-
-
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
972
-
-
Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.60 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.60mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge Profile -A
20.8
-
-
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
75
-
-
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound
consisting of applying:(a) after surface preparation, first layer of slurry of cement
@ 0.488 kg/sqm mixed with water proofing cement compound@ 0.253 kg/sqm.(b) laying second layer of Fibre glass cloth when the first layer isstill green. Overlaps of joints of fibre cloth should not be less
than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement
@ 1.289 kg/sqm mixed with water proofing cement compound@ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will
be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which
will be paid for separately.For the purpose of measurement the entire treated surface will be measured.
527
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
30
-
-
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Gutter (600 mm over all girth)
6
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal
ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
(i) Single socketed pipes. 75 mm diameter
70
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal
ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
(i) Single socketed pipes. 110 mm diameter
115
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain water pipes conforming
to IS : 13592 Type A, including jointing with seal ring conforming to
IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° 75 mm bend
20
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain water pipes conforming
to IS : 13592 Type A, including jointing with seal ring conforming to
IS : 5382, leaving 10 mm gap for thermal expansion..Bend 87.5° 110 mm bend
25
-
-
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,
handles, including applying a priming coat of approved steel primer.
24
-
-
Providing and laying damp-proof course 40mm thick with cement
concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone
aggregate 12.5mm nominal size)
80
-
-
Extra for providing and mixing water proofing material in cement concrete per 50kg
work in doses by weight of cement as per manufacturer's specification.
42
-
-
Structural steel work in single section, fixed with or without connecting
plate,including cutting, hoisting, fixing in position and applying a priming
coat of approved steel primer all complete.
500
-
-
Installation, testing and commissioning of ceiling fan, including
wiring the down rods of standard length (upto 30 cm) with 1.5
sq. mm FRLS PVC insulated, copper conductor, single core cable,
including providing and fixing phenolic laminated sheet cover
on the fan box etc. as required.
20
-
-
Supplying and fixing of following sizes of medium class PVC
conduit along with accessories in surface/recess including
cutting the wall and making good the same in case of recessed
conduit as required.25 mm
800
-
-
Providing & applying a coat of residual petroleum bitumen of grade of
VG-10 of approved quality using 1.7kg per square metre on damp proof
course after cleaning the surface with brushes and finally with apiece
of cloth lightly soaked in kerosene oil.
80
-
-