Uttarakhand Agricultural Produce Marketing Board Tender
View complete overview of Uttarakhand UKAPMB Tender
Uttarakhand Agricultural Produce Marketing Board - UKAPMB Tender
Civil And Construction
Building Construction
Eprocure
Opening Date22 Oct 2024
Closing Date13 Nov 2024
Tender Amount₹ 9,79,45,000
Costs
EMD
₹ 19,59,000Document Cost
₹ 4,720Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_UAPMB_77206_1Bid Award Id
ViewTender No
e-nivida -511/2024Tender Authority
Uttarakhand Agricultural Produce Marketing Board ViewPurchaser Address
-Website
http://https://www.ukapmb.org/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Development compressor. Of tubewell by air
40
3200
-
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c
disinfection of tubewell, all complete,
30
3500
-
Development of tubewell by OP Unit 200 mm dia
30
3500
-
Supply and fixing of 175 mm dia size M.S. tubewell cap.200 mm clamp Pumping Plant
1
3000
-
Pumping Plant Supply of submersible pump set having discharge 100 LPM of 120 mtr. Head 3 Phase 415V+10% 50 C/s with motor
complete in all respects.
2
75000
-
Supply of starter cum panel suitable for operation on 3 Phase 415 volts, 50c/s suitable capacity starter cum panel with over and under voltage protection, Ameter, Voltmeter & Phase Indicator
complete in all respect.
1
18000
-
Supply of 6 sq.mm three core submersible cable for above pumping plant.
295
172
-
Supply & Laying of 16 sq mm al armoured
4 core cable.
100
375
-
Supply and fixing Main Piping and valves
as Follows Supply of 50 mm dia 3 mtr. Long MS column pipe assembly both side threaded with socket-120 mtr. Supply of 50 mm size CIDF sluice valve 2
Nos. Supply of 50 mm size CIDF reflux valve-1
Nos Venture (50 x 75) 1 No. Supply of 50 mm size CIDF Redial TEE-1 No Supply of 50 mm size to pump outlet dia reducer and other end flanged 1 no. Supply of heavy duty MSDI clamp Supply of Tubewell cap 1 no Supply of 50 mm size CIDF 90 bend-I No. Nuts Bolts, Rubber/ Fiber packing for
jointing above pipers & special-I set Supply of 100 mm dia pressure gauge with control cock & fitting of range 0.20 kg/cm with complete with all fitting 01 set Supply of Tool kit having DE spanner set, ring spanner set, screw driver, plier,
hammer, pipe rinch, screw rinch-01 set
1
165400
-
Supply of chain pully block of 2 tone capacity 4.5 mtr lift complete in all
respect Rubber resistance sheet of size
1mx2mx0.025m Installtion, Testing & Commissioning of pumping Plant with lowering of column pipe and fixing of valve and accessories.
1
32500
-
Earthing with G.I. Earth Plate of suitable size including accessories and providing masonary enclusure with cover plate having locking arrangement and watering pipe with charcoal/coke and salt as required with supplying and laying of 25mm x 3 mm G.I. strip inlucding connection/terminating with nut, bolt, spring, washer etc. as required (Jointing shall be done by overlapping and with 2 sets of brass nut bolt& spring washer
spaced at 50 mm) as required-2 set.
2
7500
-
Testing of pumping plant at site.
1
3000
-
Painting of entire installation with two coats of super enamel paint as per
direction of Engineer in charge.
1
5000
-
Geiological & Hydrological survey.
1
30000
-
Testing of Water sample
1
30000
-
Cost of Running Maintance for 06 month.
6
30000
-
EXTERNAL SEWERAGE 5.3
300
3810
-
BOOM BARRIER (Electromechanical boom barrier with all accessories upto 6 meter length 6.26.1
1
125000
-
RCC WATER TANK (UNDERGROUND SUMP) 4.5
50000
23
-
Supply, fixing, connecting and testing of telephone / computer / TV modular sockets modular plate anodised MS box and blanking plate in surface / recessed including connectionetc as required. Data -I/O (RJ-45 Connectors) + Dats Face Plate
10
641
-
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB),having a sensitivity current upto 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp SPN RCCB with 100 ma fault current rating
12
4089
-
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB),having a sensitivity current upto 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp SPN RCCB with 100 ma fault current rating
6
4095
-
Supplying and fixing upto following amps rating, 240/415 volts, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required. 63A FP MCB
4
2329
-
Supplying and fixing upto following amps rating, 240/415 volts, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required. 40A FP MCB
2
2256
-
Supply of lighting fixtures of surface mounted 15W LED Round Downlighter luminaire. The LED source used shall be complying with LM80 standards & LED source efficacy 150 lm/w. Epoxy white powder coated die cast aluminium housing; Efficient PMMA front visor;. The system lumen output of the luminaire of a minimum of 100 lms/W with color temprature of 5700 deg K (ANSI Bin) and CRI80. Integral Driver with constant current constant voltage (CVCC), P.F 0.95, THD10% and Surge Protection of atleast 3.5KV.
40
834
-
Supply of lighting fixtures of surface mounted 12W LED Round Downlighter luminaire. The LED source used shall be complying with LM80 standards & LED source efficacy 150 lm/w. Epoxy white powder coated die cast aluminium housing; Efficient PMMA front visor;. The system lumen output of the luminaire of a minimum of 100 lms/W with color temprature of 5700 deg K (ANSI Bin) and CRI80. Integral Driver with constant current constant voltage (CVCC), P.F 0.95, THD10% and Surge Protection of atleast 3.5KV.
16
793
-
Supply of lighting fixtures of surface mounted 10W LED Round Downlighter luminaire. The LED source used shall be complying with LM80 standards & LED source efficacy 150 lm/w. Epoxy white powder coated die cast aluminium housing; Efficient PMMA front visor;. The system lumen output of the luminaire of a minimum of 100 lms/W with color temprature of 5700 deg K (ANSI Bin) and CRI80. Integral Driver with constant current constant voltage (CVCC), P.F 0.95, THD10% and Surge Protection of atleast 3.5KV.
14
793
-
Supply of 20 W linear 4ft LED integrated batten made of ultra slim co-extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.White finish ABS end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. These end caps are snap-fitted to the fixture.High efficiency long life LED with lumen efficacy of 130 lm/W with viewing angle of 120º.Powered by an integral isolated low THD electronic LED driver ( SMPS based constant current supply) with output short circuit protection, surge protection.Can be fixed directly into the wall/ ceiling by means of mounting SS clips provided with the fixture. Lumen Output of 2110 lumens with System efficacy of 105lm/W .CRI 80, Color temperature 6500K, THD 20% and PF0.95,IP20 . Life class of 35,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ.
16
560
-
Supply of 36 W linear 4ft LED integrated batten made of ultra slim co-extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.White finish ABS end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. These end caps are snap-fitted to the fixture.High efficiency long life LED with lumen efficacy of 130 lm/W with viewing angle of 120º.Powered by an integral isolated low THD electronic LED driver ( SMPS based constant current supply) with output short circuit protection, surge protection.Can be fixed directly into the wall/ ceiling by means of mounting SS clips provided with the fixture. Lumen Output of 2110 lumens with System efficacy of 105lm/W .CRI 80, Color temperature 6500K, THD 20% and PF0.95,IP20 . Life class of 35,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ.
30
2311
-
Supply of 10W LED BulK head Fitting, The LED source used shall be complying with LM80 standards & LED source efficacy 120 lm/w. Epoxy white powder coated die cast aluminium housing; Efficient PMMA front visor;. The system lumen output of the luminaire of a minimum of 100 lms/W system efficacy with color temprature of 5700 deg K (ANSI Bin) and CRI80. Integral Driver with constant current constant voltage (CVCC), P.F 0.9, THD20%,IP65 and Surge Protection of atleast 5KV.
5
886
-
Supply of following Ceiling Fan : 1200mm Sweep similar to Havells CAT no. - samart /RR Kabil
18
3214
-
Supply of following Ceiling Fan : industrial wall bracket fan
10
4192
-
Supplying of Heavy Duty Exhaust Fans 300 mm, 1400 RPM
4
4023
-
Supplying of Heavy Duty Exhaust Fans industrial exhaust
10
6026
-
Supply of UL approved low carbon high tensile steel rod with copper coating of min 254 micron JK Chemrode - 0110 CBR the dia should be 25 mm with length of 10 feet ( 3000 mm) . The rod shall be as per IEC 62561-2 and approved by UL 467. The rod shall be tested from NABL lab for current discharge not less then 46kA peak. The Chemrode shall be surrounded with 25 kg ( 1 bag) of Earth enhance materiel JK Reslow according to IEC 62561-7 and the Chemical resistance value shall not increase more then 0.067 Ωm and same will be tested from NABL lab. along with earth pit chamber made up polyplastic. Size of -254x330x260 MM (Model similar to PPC01)
36
8493
-
SITC of Vertical Electrolytic Copper Lighting Arrester of 16 mm dia, 1000 mm long with Gun Metal base plate . Model similar to APSAT116C+APSTB16-253
10
6068
-
SITC 8 mm round aluminium conductor for horizontal lightning protection - run in roof. Model similar to AL8.
100
120
-
SITC of roof conductor holder for 8 mm round aluminium conductor made of Gun Metal for horizontal installation. The distance between each holder should be min of 1 mtr. Model similar to APSRCS50.
40
186
-
SITC of T connector for connecting of 8 mm Al round conductor . The connector should be of Gun Metal with SS nuts and bolt. Model similar to APSTCRC50
20
522
-
SITC of Cross connector for connecting of 8 mm Al round conductor . The connector should be of Gun Metal with SS nuts and bolt. Model similar to APSCCRC50
20
522
-
SITC of straight connector for connecting of 8 mm Al round conductor . The connector should be of Gun Metal with SS nuts and bolt. Model similar to APSPCRC50
10
504
-
SITC of Expansion piece to compensate the expansion of round 8 mm Al conductor when temperature variation . Connection should be in every 20 mtr. Model similar to APSEXP50
10
126
-
EXPANSION PIECE CONNECTOR-
20
479
-
SITC of 8 mm round aluminium conductor as a down conductor mounted in the surface of wall which will carry the lightning current to earth pit. Model similar to AL8.
10
120
-
SITC of Down conductor holder for 8 mm round aluminium conductor of min distance between the wall to the conductor will be of 85 mm. The distance between each holder should be min of 1 mtr. Model similar to APSRCS50
10
184
-
Supply and installation of Test Clamp to disconnect the down conductor from the earth termination network for regular checks of the earth termination resistance value.
4
2743
-
SITC of 6 digit lightning strike counter. Model similar to LEC06
1
8415
-
Supplying and laying 25 mm x 5mm G.I. strip on surface or in recess for connection etc as required.
20
204
-
Providing and laying of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required.
50
174
-
SITC OF SF6 insulated, 11kV Extensible Compact VCB (type VCE) contained within a metal clad enclosure having degree of protection to IP-54, suitable for outdoor use, free standing and comprising, Annexure –A BILL OF MATERIAL FOR HT Switch Board: 1 – 630 Amp triple pole, vacuum circuit breaker with independent manually charged spring mechanism and fully rated earth switch with provision for earth of the cable. 1 - Air insulated cable box with gland plate suitable for a bottom entry 3 core cables up to 300 sq. mm. The unit will be complete with: 1 - Mimic diagram on front panel complete with status indicators 1 - Set of positive standard mechanical interlocks 1 - Set of current transformers for protective relays with ratio 100-50/1A 1 - Self powered relay: Ashida/Equivalent Reputed make 1 - Set of VPIS for Circuit breaker 1 - External stud for earthing connections 1 - SF6 gas pressure indicator and SF6 recharging facility 1 - Local ‘PULL TO TRIP’ mechanism for each breaker. 1 - Set of auxiliary terminals 1 - Operating handle MAKE :-LUCY / ABB
1
420175
-
1 No.3 phase 50 Hz 160 kVA, 11KV /415V, DYn11, core type double wound with copper conductor oil immersed ONAN cooled Distribution Transformer Off circuit Tap changer voltage ratio of 11 KV / 415V with HT & LT Cable Box. Tappings +5% to –15% in steps of 1.25% shall be provided at line end of HV winding. .Losses are as per IS -1180 Level 1 (New Ammendment)) Capacity 200 KVA Input terminals suitable for connecting 11KV XLPE aluminium conductor armoured cable enclosed in a cable box. Output terminals suitable for connecting 1.1 KV grade single core aluminium conductor cable enclosed in a cable Box. L.T. Aux. terminals connections - suitable for 1.1 KV grade PVC /XLPE cable on Transformer Part H.T.Aux. terminals – suitable for 11 KV grade XLPE Al. Cable on Transformer Part Output : 415 V +/- 1% , 3 phase 50 Hz ,Unbalanced load Winding temperature indicator with alarm and trip Contacts Pressure release valve / explosion vent to be provided on ther top of the tank. Silica gel breather Oil Temp. Indicator with alarm & trip Contacts
1
678282
-
Medium Voltage Panel NOTE: ALL ACBs ARE REQUIRED WITH SAFETY SHUTTER, UNDER VOLTAGE RELEASE / SHUNT TRIP General Note for all Panels The Panels/ Switch-boards shall be fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) CRCA sheet steel, Compartmentised design, modular construction with Form 4b separation for Main Panels & 3b for remaining, Mounting Plates and Internal Partition shall be made of 1.6/2.0mm Aluzinc sheet for better heat dessipation clear space of 300mm or as approved shall be left at the bottom.The operating handle of the topmost switch shall not be higher than 1800mm from the finished floor and maximum height of panels shall not more than 2400mm.The Panel shall be Powder coated to paint of desired shadend in an approved manner. Undervoltage Relay (27) Reverse power RELAY (32) Inverse Definite minimum time overcurrent relay Overvoltage Relay (59) Trip Circuit Supervision Relay Master Trip Relay Bucholz protection (only transformer switch ) (63) Emergency stop on each panel All incomers and Bus coupler panel door should be different colour coded for identification and mimic diagram in front of panel should be marks by reflector paints All ACB terminals shall have vertical-vertical configuration for termination of incoming & outgoing bus links. All MCCB’s up to 630A shall be provided with rear stud type terminations. Space heater, Thermostat, On/Off switch, LED Lamp , Door operated switch. All ACBs shall have protection Releases with LSIG. All Multifunction meters shall communication on ethernet through ethernet ports and shall have % THD and individual harmonics till 15 order Mimic Diagram compulsary Supply, Erection, Testing and commissioning of Indoor type ( IP 54 Protection ) cubicle pattern LT Switch-Board with a rupturing capacity of 50 KA at 415 V for 1 sec or as called for in individual items, openable in front and back suitable for 3 phase, 4 wire, 50Hz AC supply at an ambient temperature of 45 C. The cubicle should be well ventilated and enclosure protection shall be IP-54 as per IS 2147-1962.or as per CPWD specifications, ( Part IV - Sub-station) and IS: 8623 , fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) CRCA sheet steel in Compartmentised design, modular construction with Form 4b separation for Main Panels & 3b for remaining, Mounting Plates and all Internal Partition shall be made of 1.6/2.0mm Aluzinc sheet for better heat dessipation. The cubicle should be front operated, floor mounted, free standing with compartments in tier formation, extensible on both sides.The panel to be provided with PVC Sleeved 4 pole Electrolytic Al .Maximum Current density for the bus bars shall meet temp rise condition. Bus Bar and PVC insulated solid interconnections and also provided with 50x6mm. horizontal AL Earth Bus Bars in each section.(as per drawing- enclosed-Main LT Panel). Panel should be extensible type. INCOMER:- (FROM 200KVA TRANSFORMER) 1 NO. 320A FP BY Pass switch 1 Nos 320A FP MCCB 35kA With Microprocessor Based Release (O/C,S/C,E/F) Protection & all Accessories in each : 1 no. 320A FP Contactor 1 No Under Voltage Relay (27) 1 No Over Voltage Relay (59) 1 No. Multifunction Meter With RS-485 port 1 set C.T's 250/5Amp , CL 1.0, 10VA for meter 1 set C.T's 250/5Amp , CL 1.0, 10VA for APFCR 1 No A/M Selector switch 1 set Phase Indicating LED Lamps with backup MCB 1 ses ON,OFF,TRIP indicating LED Lamps with backup MCB Control SP MCB 1 no emergency stop push button switch (to control whole panel) INCOMER:- (FROM 160KVA DG) x1. for each : 1 Nos 250A FP MCCB 35kA With Microprocessor Based Release (O/C,S/C,E/F) Protection & all Accessories in each : 1 no. 250A FP Contactor 1 No Under Voltage Relay (27) 1 No Over Voltage Relay (59) 1 No. Reverse Power Protection Relay 1 No. Multifunction Meter With RS-485 port 1 set C.T's 250/5Amp , CL 1.0, 10VA for meter 1 No A/M Selector switch 1 set Phase Indicating LED Lamps with backup MCB 1 ses ON,OFF,TRIP indicating LED Lamps with backup MCB. Control SP MCB 1 Nos. 8 window annunciator with accept / reset / test push button 1 no. 24V battery INCOMER:- (FROM 82.5KVA DG) x1. for each : 1 Nos 125A FP MCCB 35kA With Microprocessor Based Release (O/C,S/C,E/F) Protection & all Accessories in each : 1 No. 100A FP Contactor 1 No Under Voltage Relay (27) 1 No Over Voltage Relay (59) 1 No. Reverse Power Protection Relay 1 No. Multifunction Meter With RS-485 port 1 set C.T's 100/5Amp , CL 1.0, 10VA for meter 1 No A/M Selector switch 1 set Phase Indicating LED Lamps with backup MCB 1 ses ON,OFF,TRIP indicating LED Lamps with backup MCB. Control SP MCB 1 Nos. 8 window annunciator with accept / reset / test push button 1 no. 24V battery Note: DG to be cranked from Main Panel only. AMF feature in Main panel only. DG's are on Auto Load Management via PLC. BUSCOUPLER x 1 Nos. For each: 1 Nos 100A FP MCCB 1 No. 100A FP Contactor 1sets ON,OFF indicating LED Lamps with backup MCB. BUSBAR :- FP aluminium bus bars of minimum 1000 Amp with heat shrinkable coloured sleeves , Shrouds at Joints and including DMC/SMC bus bars supports at required interval complete for cross section, side supports and their spacing etc. for withstanding fault level of 31 MVA for 1 sec OUTGOING Note: ON Indication Light for all Outgoings. with backup MCB Section-A 1 Nos. 160Amps TPN ,MCCB with Thermal Magnetic Release adjustable with rotary handle for 70KVAR capacitor Panel FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle for External Lighting, Spare This panel should include 1 no. Busbar mounting Surge Protection Device Class B+C/ Class 1+2 Tested as per IEC 61643 Part 11:2011 & UL 1449 4th edition . Nominal voltage -230V 50/60Hz, MCOV of 350 V , Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 560KA (8/20µ sec), Voltage protection level 1.3 kV . The Surge Protection Devices should have TOV withstand for 120 Min 440 V and with out Follow Current & the Protection Modes for : L & N to PE . The connections (Three Lines & Neutral) should be directly connected to Protective Earth Terminal for better response time. Short- Circuit Current rating (Isccr) – 85 kA/50 Hz. Total Response time 1 nano sec. Miscellaneous items 2 nos door switch 2 nos illumination lights with 6 A,10kA MCB ILLUMINATION LED WITH HOLDER & DOOR SWITCH2 nos 6" dia exhaust fan with thermostate & suitable canopyInternal illumination in Cable alleys with Door operated switch. complete panel as above
1
517275
-
Supply, Erection, Testing and commissioning of indoor type cubicle pattern LT Switch-Board with a rupturing capacity of 50 KA at 415 V or as called for in individual items, openable in front and back suitable for 3 phase, 4 wire, 50Hz AC supply at an ambient temperature of 45 C. The cubicle should be vermin proof, well ventilated and enclosure protection shall be IP-54 as per IS 2147-1962.or as per CPWD specifications, ( Part IV - Sub-station) and IS: 8623 The cubicle should be front operated, floor mounted, free standing with compartments in tier formation, extensible on both sides. The panel to be provided with PVC Sleeved TPN Electrolytic Al. Bus Bar and PVC insulated solid interconnections and also provided with 50x6mm. horizontal tinned copper Earth Bus Bars in each section.70kVAR APFC Panel. 1 Nos. 160Amps TP ,MCCB with Thermal Magnetic Release adjustable with rotary handle from Main Panel 2 nos. Capacitor duty contactor suitable rating for 10 kVAR Rating 1 nos. Capacitor duty contactor suitable rating for 20kVAR Rating 1 nos. Capacitor duty contactor suitable rating for 25kVAR RatingDetuned Harmonic Filters 1 nos. 440 V, 7% detuned 5 Kvar reactor 2 nos. 440 V, 7% detuned 10 Kvar reactor 1 nos. 440 V, 7% detuned 20 Kvar reactor 1 nos. 440 V, 7% detuned 25 Kvar reactor Capacitor Banks 1 nos. 480 V, 10 kvar super heavy Capacitor Bank for 5 kvar 2 nos. 480 V, 12.5 kvar super heavy Capacitor Bank for 10 kvar 1 nos. 4805 V, 25 kvar super heavy Capacitor Bank for 20 kvar 1 nos. 480 V, 30 kvar super heavy Capacitor Bank for 25 kvar Miscellaneous items 4nos door switch 4 nos illumination lights with 6 A,10kA MCB ILLUMINATION LED WITH HOLDER & DOOR SWITCH 4 nos 6" dia exhaust fan with thermostate & suitable canopy Internal illumination in Cable alleys with Door operated switch. Complete Panel as Above and complete
1
323312
-
Fabrication supply, installing,testing & commission and connecting with main LT Panel of indoor type dust and vermin proof hinged and lockable doors at back side made out of 14 SWG CRCA MS Sheet including painting and complete with interconnections, Top entry, cable glands,removable gland plate, plugs, bonding to earth with 2 independent earth connections having 2 nos 25x6mm GI strip at bottom of panel as earth bus ,the construction of panel shall be compartmentalised, very compact, easy in maintenance .provision of ventilation shall be through axial flow fans system Legend plate of suitable size of showing panel no. and name of panel for outgoing feeder and as per the following and as per drawing for Workshop Panel
INCOMER:- 1 Nos. 100Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle 1 set Phase Indicating LED 1 Nos Multifinction Meter With RS-485 port 1 sets Current Transformer 100/5A, Cl-1.0, 10VA 6 Nos. Control MCB BUSBAR :- 160 Amps 4 pole aluminum conductor ( CD 0.8A /sq.mm. ) bus bar (PVC sleeve Heat-shrinkable busbar insulation) supported by DMC / FRP insulator (MAIN BUSBAR) OUTGOING 3 Nos. 63Amps FP ,MCB 2 Nos. 40Amps FP ,MCB 10 Nos. 16Amps FP ,MCB 2 Nos. 10Amps FP ,MCB 1 No. Type C SPD with indication and fuse. complete panel as above
1
139150
-
Design, Manufacture, Supply, Installation, Testing and Commissioning of Panel Fabricated out of 16 SWG CRCA sheet steel, IP 54, wall / floor mounting type with rain canopy The sheet steel shall undergo minimum 7 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes 415 /240 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands, including connection with outgoing feeders complete in all respect, Panel Should Have Double Earthing Provision Which Connected to the Nearest Earth Grid. External Lighting Panel INCOMER:
1 no. 63 A, 16KA 4P MCCB with Thermal Magnetic based releases, ON indication, 1 no. multifunction meter with RS-485, with selector switch, matching cast resin CT's. BUS BAR
TPN Aluminium bus bar with heat Shrink Sleeve rated for 100A. OUTGOING
4 nos 32A DP MCB ON indication lamps with 9 nos astronimical time swtich for automaitc switching of landscape light fixtures at sun set and sun rise or twillight ( auto on/ auto off and auto mode)with manual override faiclity with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site. 1 nos 63A 4P MCB (SPARE) 1 nos 40A 4P MCB (SPARE) Other items such as 1 Set of control wiring 1 Set of designation plates All Items complete as above
1
116402
-
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 4Cx10
30
224
-
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 4Cx16
30
270
-
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 4Cx25
60
330
-
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx35
50
384
-
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx50
100
510
-
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx70
50
690
-
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx95
90
864
-
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx120
150
1062
-
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required 3.5Cx150
100
1244
-
Supply and Laying of heavy duty copper armored cables 1.1 KV grade including necessary support clamps at ceiling level and connection legs,glands etc complete in all respects. Control cable 10 core 2.5 Sq.mm
50
420
-
Supply & Testing of following 11 KV( UE) grade multicore Aluminium conductor XLPE insulated cable, insulation screening with extruded semi conducting compound in combination with copper tape armoured cores laid up, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - II) and complete with all latest amendments etc. complete as required. 3 C x 70 Sq. mm 11 KV (E)
25
986
-
SITC of “Silent Type” following KVA Sound Attenuated DG Set comprising of engine coupled to 415V, following KVA alternator mounted on a common Base Frame along with other accessories i.e. Engine Control Panel, internal Fuel tank(for min. 5 hrs back up capacity at 75% load), Batteries with lead,etc as reqd for smooth operation of Genset. The DG Set should be supplied with cable terminal box to accommodate suitable size and no. of cable on alternator complete as reqd and shall have remote monitoring system for genset health monitoring. The Dg set designed and supplied shall be as per latest CPCB 4+ Norms and relevant DG set approval certificates shall be provided with supply at site. Diesel Engine: CPCB4+ compliant watercooled Diesel engine, first Service interval of 500 Hr/1 Year Whicever is earlier, electric start, of suitable BHP at 1500 RPM suitable for following KVA output of alternator at 40 Degree C, 50%RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation as per prime rating standards. The engine will be fitted complete with all the required accessories, Factory Inspection of complete Silent DG Set must be at principle Engine Manufacturer Work, genset must be fuel efficient at partial load like 50%,75%&100%, Complete package manufacture factory. Engine mounted Instrument Panel (Auto/Manual) fitted with and having digital display for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication (vi) RPM indication (vii) Over speed indication (viii) Low lub. Oil trip pressure indication (ix)DG Controller having feature to show HSD fuel consumption Units/ ltr. (x) Engine Hours indication
Alternator :
Synchronous alternator rated at following KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, prime duty, self-excited and self-regulated having AREP / PMG for better harmonics control conforming to IS: 4722/BS 2613 suitable for tropical conditions and with Class-H insulation and temp rise limited to Class -H insulation too.
Base Frame & Foundation FOR Engine and Alternator:
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
Base Frame & Foundation For Daily Service Fuel Tank: Fuel tank of suitable as per mfg Standard capacity for fabricated out of 2mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.
Exhaust System:
Dry exhaust manifold with residential / hospital Grade exhaust silencer as per manufacturer design.
Starting System:
12V / 24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plates, 180 Amp / as per OEM.-Hour capacity lead acid type) as required as per specifications.
Acoustic and weather proof enclosure
Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per specifications. 160 KVADG Set
1
2382001
-
SITC of “Silent Type” following KVA Sound Attenuated DG Set comprising of engine coupled to 415V, following KVA alternator mounted on a common Base Frame along with other accessories i.e. Engine Control Panel, internal Fuel tank(for min. 5 hrs back up capacity at 75% load), Batteries with lead,etc as reqd for smooth operation of Genset. The DG Set should be supplied with cable terminal box to accommodate suitable size and no. of cable on alternator complete as reqd and shall have remote monitoring system for genset health monitoring. The Dg set designed and supplied shall be as per latest CPCB 4+ Norms and relevant DG set approval certificates shall be provided with supply at site. Diesel Engine: CPCB4+ compliant watercooled Diesel engine, first Service interval of 500 Hr/1 Year Whicever is earlier, electric start, of suitable BHP at 1500 RPM suitable for following KVA output of alternator at 40 Degree C, 50%RH & at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation as per prime rating standards. The engine will be fitted complete with all the required accessories, Factory Inspection of complete Silent DG Set must be at principle Engine Manufacturer Work, genset must be fuel efficient at partial load like 50%,75%&100%, Complete package manufacture factory. Engine mounted Instrument Panel (Auto/Manual) fitted with and having digital display for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication (vi) RPM indication (vii) Over speed indication (viii) Low lub. Oil trip pressure indication (ix)DG Controller having feature to show HSD fuel consumption Units/ ltr. (x) Engine Hours indication
Alternator :
Synchronous alternator rated at following KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH & at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, prime duty, self-excited and self-regulated having AREP / PMG for better harmonics control conforming to IS: 4722/BS 2613 suitable for tropical conditions and with Class-H insulation and temp rise limited to Class -H insulation too.
Base Frame & Foundation FOR Engine and Alternator:
Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
Base Frame & Foundation For Daily Service Fuel Tank: Fuel tank of suitable as per mfg Standard capacity for fabricated out of 2mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.
Exhaust System:
Dry exhaust manifold with residential / hospital Grade exhaust silencer as per manufacturer design.
Starting System:
12V / 24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plates, 180 Amp / as per OEM.-Hour capacity lead acid type) as required as per specifications.
Acoustic and weather proof enclosure
Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per specifications. 82.5 KVADG Set
1
1059231
-
Supply, Installation, Testing And Commisioning of 1 No. Indoor Digital Micro Processor Based Servo Voltage Stabilizer 200 kVA, Linear Type, Indoor, 3 Phase, Balanced Type, Input Voltage 330-470V Output voltage 400V ±1% .
1
415756
-
Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part- 2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 1 O years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from O to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. Above 10 kWp and up to 100 Kwp
50
66550
-
Supplying and fixing integral post top lantern with 40 watt LED fitting comprises of copper dust finish cast aluminium spigot and spun aluminium canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting, open construction driver and accessories are wired up to terminal block. LED of 1 to 3 W each assembled on single MCPCB, having color temp 6500K & having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy80lm/W. LED driver PF 0.95 & surge protection 2KV.The colour rendering index of LED light should be more than 70. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory. i/c connection wire, testing etc. to complete the job. 2 Yrs Guarantee certificate from manufacturer.
2
6933
-
Supply , Installation, Testing & Commissioning of 60 W LED with complete with pot optic reflector including connection with 3x2.5sq.mm single core PVC insulated copper conductor cable from junction box to fixture as required
20
9704
-
Supply,Installation,TestingandCommissioningof202x238x111(KVPC)Polycarbonatethermoplasticsenclosure junctionboxwithI.P-65Protectionwithcablehingedcoverofapproveddesigncompletehavinggasketofinternallyembedded&madeofpolyeutherene&shouldbeweatherproof,rustproof,dustproof,waterproof-boxshallbetestedasperIEC-60670-2/60670-22.theboxshallhaveselfthreadedholes&provisionformountingdinrail.with2Noscableglandincludingsupplying&fixingcrimping2noslugs&1nos32Aconnector6wayforloopingtheincoming&outgoingcablesandalsoconnectionofthestreetlightone6ASPMCBIncludingConnection of 2x6 sqmm Cable etc as Required
20
1391
-
Supplying of 8 mtr long hot dip Galvanized octagonal Pole with top of the pole 70 mm dia (A/F) and bottom of the pole 135 mm dia (A/F) made out of 3mm sheet with MS base plate of size 225mm (NS) x 225mm (NS) x 16mm (NS) on precast RCC foundation complete with suitable size opening inside the pole with flush weather proof door with locking facility preferably with LN key having proper arrangement with Accommodating of 1 Nos. 6 Amp.,10 KA MCB & neutral link 4 way connector suitable for 25 Sqmm cable complete with electrically safe including inside cable termination with thimbles i/c wiring from pole box to fitting with 3x1.5 sq.mm. FRLS PVC insulated copper conductor wire, earth connection, din channel, earth stud and other accessories pertaining to this pole (But without street light fitting) etc as reqd.including providing & laying in position suitable RCC foundation as required for 6 mtr. octagonal hot dip Galvanized Pole as per Manufacturers drawing with 1:1.5:3 concrete (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) including excavation of all kind of earth such as all type of soil/soft rock or hard rock etc. as per existing site condition i/c providing, cutting, bending and placing reinforcement & J type foundation bolts , anchor plate and templates in position as per manufacturer Standard and Providing PVC Pipe for Cable Entry and Exits Including Disposal of Surplus Malba / Softrock / Hardrock Stone etc.as Required.
20
12052
-