The Bazpur Cooperative Sugar Factory Limited Tender

View complete overview of Uttarakhand The Bazpur Cooperative Sugar Factory Limited Tender

The Bazpur Cooperative Sugar Factory Limited Tender

Works
Machinery and Tools
Eprocure
Opening Date31 May 2024
Closing Date6 Jun 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling, Fabrication and erection of Seamless nipple of 82.5 mm. OD. x 3.66 mm.Thick. x 150 mm. long of VKW. Boiler. (a) with supply

-

-

-

... More
(b) without supply

-

-

-

... More
Rate of per welding joint of boiler tubes (a) 44.5mm.OD

-

-

-

... More
(b) 63.5mm.OD

-

-

-

... More
(c) 70.0mm.OD

-

-

-

... More
(d) 76.2mm.OD

-

-

-

... More
(d) 82.5mm.OD

-

-

-

... More
Replacement of old & worn out Coil type economizer coils of WIL Boiler 40Ton/Hr by New supplied coils as per side requirement complete IBR Norms.

-

-

-

... More
Replacement of 63.5mm. OD x 3.66mm.Thick drum to drum tube of WIL Boiler Cap.40Ton/Hr. The work include dismantling, febrication & erection Hydraulic testing at desire pressure and approval from Director of Boiler Uttrakhand.

-

-

-

... More
Replacement of 70mm. OD x 4.06mm.Thick Screen tube of WIL Boiler Cap.40Ton/Hr. The work include dismantling, febrication & erection Hydraulic testing at desire pressure and approval from Director of Boiler Uttrakhand.

-

-

-

... More
Replacement of 76.2mm. OD x 4.06mm.Thick Front Bank Tube of Taxmaco Boiler Cap.30Ton/Hr. The work include dismantling, febrication & erection Hydraulic testing at desire pressure and approval from Director of Boiler Uttrakhand.

-

-

-

... More
Dismantling, Febrication & Erection of Steam Line according to IBR Norms

-

-

-

... More
Dismantling, Febrication & Erection of Bend of Steam Line according to IBR Norms

-

-

-

... More
Dismantling, Febrication & Erection of Flange of Steam Line according as per IBR Norms

-

-

-

... More
Replacement of 76.2mm. OD x 4.06mm.Thick Riser Tube of Taxmaco Boiler Cap.30Ton/Hr. The work include dismantling, febrication & erection Hydraulic testing at desire pressure and approval from Director of Boiler Uttrakhand.

-

-

-

... More
Replacement of 82.5mm. OD x 3.66mm.Thick Curculation tube of Taxmaco Boiler Cap.30Ton/Hr. The work include dismantling, febrication & erection Hydraulic testing at desire pressure and approval from Director of Boiler Uttrakhand.

-

-

-

... More
Replacement of size 76.2mm. OD x 4.06mm.Thick Side wall tube of Taxmaco Boiler Cap.30Ton/Hr. The work include dismantling, febrication & erection Hydraulic testing at desire pressure and approval from Director of Boiler Uttrakhand.

-

-

-

... More
Replacement of old/wormout coil type economizer coils size 44.5mm.OD x 3.66mm. of Taxmaco Boiler Cap.30Ton/Hr. The work include dismantling, febrication & erection Hydraulic testing at desire pressure and approval from Director of Boiler Uttrakhand.

-

-

-

... More
Replacement of size 44.45mm. OD x 3.66mm.Thick super heater coil of Taxmaco Boiler Cap.30Ton/Hr. The work include dismantling, febrication & erection Hydraulic testing at desire pressure and approval from Director of Boiler Uttrakhand.

-

-

-

... More
Replacement of old/wormout 63.5mm.OD x 3.66mm. Thick Rear Bank tube of Taxmaco Boiler Cap.30Ton/Hr. The work include dismantling, febrication & erection Hydraulic testing at desire pressure and approval from Director of Boiler Uttrakhand.

-

-

-

... More
Replacement of old/wormout 76.2mm.OD x 3.66mm. Thick roof tube of Taxmaco Boiler Cap.30Ton/Hr. The work include dismantling, febrication & erection Hydraulic testing at desire pressure and approval from Director of Boiler Uttrakhand.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.