State Infrastructure And Industrial Development Corporation Of Uttarakhand Limited Tender
View complete overview of Uttarakhand SIIDCUL Tender
State Infrastructure And Industrial Development Corporation Of Uttarakhand Limited - SIIDCUL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Feb 2023
Closing Date6 Mar 2023
Tender AmountRefer Documents
Costs
EMD
₹ 82,000Document Cost
₹ 3,540Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_SIDCU_54792_1Bid Award Id
ViewTender No
91/SIIDCUL/2023Tender Authority
State Infrastructure And Industrial Development Corporation Of Uttarakhand Limited ViewPurchaser Address
-Website
http://https://www.siidcul.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and drawing 1x1.5 sqmm sizes of FRLS PVC insulated copper conductor single core cable in existing surface /recessed steel/PVC conduit as required
1000
25990
-
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cable XLPE 35 Sqmm 3.5 core 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top.
500
211000
-
Supply of aerial bunch cable 4x25 sqmm (3core25+25sqmm) as per the site requirement including material for laying of the cables on poles excluding labour charges
1000
102000
-
Supply of aerial bunch cable 4x16 sqmm (3 core 16+25sqmm) as per the site requirement including material for laying of the cables on poles excluding labour charges
1000
76000
-
Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respect
800
823000
-
Repairing of 60 watt LED light by replacement of damage/ diffused Drivers as per the site requirement including material charge but excluding labour charges.
300
379575
-
Repairing of 60 watt LED light by replacement of damage/ diffused MPCB plates as per the site requirement including material charge but excluding labour charges.
300
233391
-
Repairing of 150 watt LED light by replacement of damage/ diffused drivers as per the site requirement including material charge but excluding labour charges.
20
36898
-
Repairing of 150 watt LED light by replacement of damage/ diffused MPCB plates as per the site requirement including material charge but excluding labour charges.
1
1249
-
Repairing of street lights/high mast electrical control panel by replacing 03 pole power contactor type MNX-70 including material charges but excluding labour charges. One in each panel . (as per site requirment)
4
25493
-
Repairing of street lights/high mast electrical control panel by replacing timer auto light including material charges but excluding labour charges.
4
8751
-
Repairing of street lights electrical control panel by replacing 3 pole MCCB 100 amps including material charges but excluding labour charges.
3
11981
-
Repairing of street lights/high mast electrical control panel by replacing MCB 4 way 40 amps C curve including material charges but excluding labour charges.
10
18220
-
Lifting Vehicle/Hydra required for overhead street light maintanace purpose(on hire basis)@minimum 7hr/day and requirement for miimum 2 days in a week. Hence 7x2=14 hrs/week. Total weeks in a year = 365/7=52 weeks, hence total weeks reuired 52 x14 hrs = 728 Hrs
728
800800
-
Repairing and rewinding of Non Clog Submersible Motor 20 HP including lifting and lowering with repairing of damage casing ,mechanical seal ,motor bush and complete in all respect with labour and material
1
30000
-
Repairing and rewinding of NON CLOG SUBMERSIBLE MOTOR 25 HP including lifting and lowering with repairing of damage casing,mechanical seal ,motor bush and complete in all respect with labour and material
1
32000
-
Repairing and rewinding of NON CLOG SUBMERSIBLE MOTOR 30 HP including lifting and lowering with repairing of damage casing,mechanical seal ,motor bush and complete in all respect with labour and material
1
32000
-
Repairing and rewinding of NON CLOG SUBMERSIBLE Pump Set UP TO 25 HP including lifting and lowering with repairing of damage casing, complete in all respect with labour and material
1
14000
-
Motor bush repair of existing make model
1
1800
-
Impellers repair of existing make model
1
5500
-
Repairing and rewinding of NON CLOG SUBMERSIBLE Pump set 30 HP including lifting and lowering with repairing to damage casing , complete in all respect with labour and material
1
15000
-
Motor bush repair of existing make model
1
1800
-
Impellers repair of existing make model
1
5500
-
Supply and Fix electric cable 6 sqmm 4 core copper conductor for Non clogging submersible pump set with pump set and starters with existing panel board of ETP pumping station complete in all respect
100
40900
-
Supply and Fix 3 pole power contactors Type MNX confirms to IS/IEC 60947-4.1& IEC 60947-4-1 size FR1 Type MNX 32 with existing panel board of ETP pumping station
1
2200
-
S&F MCCBs for motor back up protection 3 pole MCCB 100Amp type DNO-100M with existing panel board of ETP pumping station
1
4931
-
Annual Maintenance of DG sets installed at SIIDCUL officeby the follwing works Replacement of lubrication oil,Air and oil filters,gear oil,Battery inclduing repairing of canopy steel body and painting works material and Labour. ( 01 services per year )
1
20000
-
Annual Maintenance and repair of Servo panel installed at SIIDCUL offices or for street light's Back Up energy inclduing material and Labour.
1
15000
-
Annual Maintenance / Servicing of Air Conditioners ( Ductable / Window/Split ) Total 12 Nos installed at SIIDCUL offices including labour and material Scope of Maintenance 1. Servicing of all Air conditioners any type Twice in year before summer & Post Monsoon 2. Gas charging and Nitrogen testing for leakage test on demand or when applicable 3. Starting Capacitor,Running capacitor,Motor etc repair and replacement when applicable
4. Replacement of defected Compressor only 02 Nos in repair replacement when required up to 2 Ton (extra payment for extra compressors after repairing 02 compressors )
5. All Indoor unit Out door unit washing and cleaning during servicing 6. Shifting of ACs 02 Nos as per site requirement inside building 7. Provision of new outdoor stands 05 Nos 8. Copper tubing or piping work 12 mtr 9. Attending complaint on call 10 Minor internal electric complaints defect rectification extra payments for replacing MCBs
12
72000
-
Supply of Insulation Tape,HT Insulation Tape aluminium lugs, nut bolts tools etc excluding labour charges
1
21000
-
Annual Maintenance of Transformer installed for Main supply of Street Lights inclduing Dehydration of transformer Oil, OTI / WTI Calibration etc .( once in year )
1
30000
-
M&L for CT UNIT 11 KV CT coils are encapsulated in cast resin (Polyester / PU / Epoxy). Secondary terminals are provided with either screws or studs. having Power 11 KV Short Time Thermal Current 3 KA to 18.4 KA for 0.5 to 3 Second Short Time Dynamic Current 2.5 x Ith Output Burden Upto 40 VA, 0.8 PF lagging Accuracy Class 0.2s (Min.) for metering 5P/10P/15P/PS for Protection CT ratio 100/5 Amp
3
11100
-
M&L for PT UNIT 11 KV Indoor Epoxy Cast Potential Transformer Material Copper,Three Phase,Accuracy Class 0.5,Output Burden Upto 40 VA, 0.8 PF,Cooling type Dry type Rated voltage 11 KV
3
45000
-
M&L for 11 KV VACUME CIRCUIT BREAKER & SERVICE &MAINTINANCE with following : Checking of entire Circuit ,Tightness of bolts and nuts.Breaker,Cleaning with a vacuum cleaner all Dust and foreign matter. Wipe with a clean, dry cloth and recommended cleaning agent (AS66). Replacement of Deformation, excessive wear and damage Replace when damaged ,Lost or missing parts Checking of Control circuits ,Auxiliary switch ,Operating mechanism and the closing and tripping devices. .Clean off old lubricant and apply a fresh lubricant, if necessary Callibration and Testing by measurment of all neccessary values for effective operations
1
15000
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements