Soban Singh Jeena Government Institute Of Medical Sciences And Research Tender
View complete overview of Uttarakhand SSJGIMSR Tender
Soban Singh Jeena Government Institute Of Medical Sciences And Research - SSJGIMSR Tender
Healthcare and Medicine
Eprocure
Opening Date21 Sep 2024
Closing Date5 Oct 2024
Tender AmountRefer Documents
Costs
EMD
₹ 30,000Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_SSJM_76090_1Bid Award Id
ViewTender No
GMC/Sub Station/AMCTender Authority
Soban Singh Jeena Government Institute Of Medical Sciences And Research ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender form with necessary directions and instruction
BOQ Items
Overhauling/Servicing of air circuit breaker 1000 AMP (A.B.B/Schneider Make) Twice a year
1
-
-
Servicing of TRANSFORMER 1600 KVA Single Service Per Year. ABB/Schneider
1
-
-
Servicing of VCB 630 AMP. HT Twice A Year ABB/Schneider
1
-
-
Relay Testing By Secondary Injection of Overcurrent and earth Fault elements. Once a year
1
-
-
Dehydration of transformer oil if Required each Transformer of Rating 1200-1600 KVA Per year
1
-
-
Servicing of RTCC Panel 1.6 MVA Twice A Year ABB/Schneider
1
-
-
Servicing of APFC Panel 500 KVAR Twice A Year ABB/Schneider
1
-
-
Servicing and Overhauling bus bar complete panel with cleaning works of MCCB/SFUs in panel.(service of Bus Bar New LT panel & DG SET) complete in all respect
1
-
-
Synchronization Pannel
1
-
-
11 KV Substation Government Medical College Almora(LT panel ACB)
-
-
-
Overhauling/Servicing of air circuit breaker 2000 AMP (A.B.B/Schneider Make) Twice a year
1
-
-
Servicing of ATS 630 AMP. Twice A Year ABB/Schneider
1
-
-
Servicing of TRANSFORMER 1250 KVA Single Service Per Year. ABB/Schneider
1
-
-
Dehydration of transformer oil if Required each Transformer of Rating 1200-1600 KVA Per year
1
-
-
Servicing of VCB 630 AMP. HT Twice A Year ABB/Schneider
1
-
-
Relay Testing By Secondary Injection of Overcurrent and earth Fault elements. Once a year
1
-
-
Servicing of RTCC Panel 1.25 MVA Twice A Year ABB/Schneider
1
-
-
Servicing of APFC Panel 400 KVAR Twice A Year ABB/Schneider
1
-
-
Servicing and Overhauling bus bar complete panel with cleaning works of MCCB/SFUs in panel.(service of Bus Bar New LT panel & DG SET) complete in all respect
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements