Rural Works Department Tender
View complete overview of Uttarakhand RWD Tender
Rural Works Department - RWD Tender
Eprocure
Opening Date9 Jul 2021
Closing Date24 Jul 2021
Tender AmountRefer Documents
Costs
EMD
₹ 5,00,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_RES_34324_3Bid Award Id
ViewTender No
343/T.I-02/RWD/21-22Tender Authority
Rural Works Department ViewPurchaser Address
-Website
http://https://res.uk.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Random rubble masonry with hard stone in foundation and plinth including
levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12
graded stone aggregate 20 mm nominal size) upto plinth level with :
7.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand)
136.97
-
-
Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up
to 50 m and lift upto 1.5 m.
221.43
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in foundation and plinth in:
6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
6.37
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
11.53
-
-
Providing and laying in position specified grade of reinforced cement
concrete, excluding the cost of centering, shuttering, finishing and
reinforcement - All work up to plinth level :
5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone
aggregate 20 mm nominal size)
107.77
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class
designation 7.5 in superstructure above plinth level up to floor V level in
all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
228.2
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricks
of class designation 7.5 in superstructure above plinth level up to floor
V level.Cement mortar 1:4 (1 cement :4 coarse sand
234.95
-
-
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at
every third course of half brick masonry
234.95
-
-
\Reinforced cement concrete work in walls (any thickness), including
attached pilasters, buttresses, plinth and string courses, fillets, columns,
pillars, piers, abutments, posts and struts etc. above plinth level up to
floor five level, excluding cost of centering, shuttering, finishing and
reinforcement :
5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone
aggregate 20 mm nominal size)
185.47
-
-
Centering and shuttering including strutting, propping etc. and removal
of form for :
5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
100.83
-
-
Centering and shuttering including strutting, propping etc. and removal
of form for :Suspended floors, roofs, landings, balconies and access
platform
553.89
-
-
Centering and shuttering including strutting, propping etc. and removal
of form for :Lintels, beams, plinth beams, girders, bressumers and
cantilevers
631.46
-
-
Centering and shuttering including strutting, propping etc. and removal
of form for Columns, Pillars, Piers, Abutments, Posts and Struts
394.58
-
-
Centering and shuttering including strutting, propping etc. and removal
of form for Cornices and mouldings
10.73
-
-
Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete upto plinth levelHot rolled deformed bars
16919.89
-
-
Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete above plinth level.Hot rolled deformed bars
29118.79
-
-
Steel work welded in built up sections/ framed work, including cutting,
hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as requiredIn gratings, frames, guard bar, ladder, railings, brackets, gates
and similar works
2467.51
-
-
Steel work in built up tubular (round, square or rectangular hollow tubes
etc.) trusses etc., including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer, including welding and
bolted with special shaped washers etc. complete.
10.16.1 Hot finished welded type tubes
8280.53
-
-
Providing and fixing 50 + 30mm thick precoated galvanised iron puf insulated sandwich sheet (puf roof panel) with dansity of 40+2 kg/m3 ,the top covering on roof panels wiill tapezoidal precoated galvanizes iron sheet with crest height 30+1 crest width 24+1 mm and pitch 200+1mm and bottom covering on roof panel shall be micro ribbing )precoated galvanizes iron sheet as approoved by eng in-charge 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120
grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns
epoxy primer on both side of the sheet and polyester top coat 15-18
microns. Sheet should have protective guard film of 25 microns
minimum to avoid scratches during transportation and should be
supplied in single length upto 12 metre or as desired by Engineerin-
charge. The sheet shall be fixed using self drilling /self tapping
screws of size (5.5x 55 mm) with EPDM seal, complete upto any
pitch in horizontal/ vertical or curved surfaces, excluding the cost of
purlins, rafters and trusses and including cutting to size and shape
wherever required
409.4
-
-
Providing and fixing precoated galvanised steel sheet roofing accessories
0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams
per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy
primer on both side of the sheet and polyester top coat 15-18 microns
using self drilling/ self tapping screws complete :
12.51.1 Ridges plain (500 - 600mm)
26.57
-
-
Providing and fixing precoated galvanised steel sheet roofing accessories
0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams
per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy
primer on both side of the sheet and polyester top coat 15-18 microns
using self drilling/ self tapping screws complete : Gutter (600 mm over all girth)
12.9
-
-
Providing and fixing false ceiling at all heights with integral densified
calcium silicate reinforced with fibre and natural filler false ceiling
tiles of Size 595x595 mm of approved texture, design and patterns
having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per
IS 8225:1987, Light reflectance of 85% (minimum). Non combustible
as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7),
humidity resistance of 100%, thermal conductivity 0.043 W/m K
as per ASTM 518:1991, in true horizontal level suspended on interlocking
metal powder coated T-Grid of hot dipped galvanised iron
section of 0.40 mm thick on Silhouette profile,rotary stiched double
webbed white with 6mm reveal profile (white/black),comprising of
main-T runners of size 15x42mm of length 3000 mm, cross - T of
size 15x42 mm of length 1200 mm and secondary intermediate cross-
T of size 15x42 mm of length 600mm to form grid module of size
600 x 600 mm, suspended from ceiling using galvanised mild steel
items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm
outer diameter M-6 dash fasteners, 6 mm dia fully threaded hang
265.63
-
-
Providing and fixing pressed steel door frames conforming to IS: 4351,
manufactured from commercial mild steel sheet of 1.60 mm thickness,
including hinges, jamb, lock jamb, bead and if required angle threshold
of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,
pressed mild steel welded or rigidly fixed together by mechanical means,
including M.S. pressed butt hinges 2.5 mm thick with mortar guards,
lock strike-plate and shock absorbers as specified and applying a coat
of approved steel primer after pre-treatment of the surface as directed
by Engineer-in-charge:Profile B
10.14.1.1 Fixing with adjustable lugs with split end tail to
each jamb
324.6
-
-
12 mm cement plaster1:6 (1 cement: 6 fine sand)
2343.2
-
-
12 mm cement plaster of mix :
13.4.1 1:4 (1 cement: 4 coarse sand
35
-
-
6 mm cement plaster of mix :
13.16.1 1:3 (1 cement : 3 fine sand
553.89
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to
IS: 15622 (thickness to be specified by the manufacturer), of approved
make, in all colours, shades except burgundy, bottle green, black of
any size as approved by Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,
including pointing in white cement mixed with pigment of matching shade
complete.
92.55
-
-
Providing and laying Ceramic glazed floor tiles of size 300x300 mm
(thickness to be specified by the manufacturer) of 1st quality conforming
to IS : 15622 of approved make in colours such as White, Ivory, Grey,
Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :
4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including
pointing the joints with white cement and matching pigment etc.,
complete.
42.58
-
-
12 mm thick one side Pre-laminated particle board (decorative
lamination on one side and other sides balancing lamination)
grade -1, medium density flat pressed, three layer particle
board FPT - I or graded wood particle board FPT-1 conforming
to IS : 3087 bonded with BWP type synthetic resin adhesive
as per IS : 848 and pre-laminated conforming to IS : 12823,
Grade -1, Type II marked :
260.48
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08%
and conforming to IS: 15622, of approved make, in all colours and shades,
laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),
jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the
joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm
574.97
-
-
Providing and fixing 18 mm thick gang saw cut, mirror polished,
premoulded and prepolished, machine cut for kitchen platforms, vanity
counters, window sills, facias and similar locations of required size,
approved shade, colour and texture laid over 20 mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,
mixed with matching pigment, epoxy touch ups, including rubbing, curing,
moulding and polishing to edges to give high gloss finish etc. complete
at all levels.8.2.2 Granite of any colour and shade
8.2.2.1 Area of slab upto 0.50 sqm
42.39
-
-
Providing and fixing ISI marked flush door shutters conforming to IS :
2202 (Part I) non-decorative type, core of block board construction with
frame of 1st class hard wood and well matched commercial 3 ply
veneering with vertical grains or cross bands and face veneers on both
faces of shutters:
9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges
with necessary screws
108.36
-
-
Extra for Providing and fixing flush doors with decorative veneering instead
of non decorative ISI marked flush door shutters conforming to IS: 2202
(Part I)
9.22.1 On one side only
95.76
-
-
Providing and fixing aluminium sliding door bolts, ISI marked anodised
(anodic coating not less than grade AC 10 as per IS : 1868),
transparent or dyed to required colour or shade, with nuts and screws
etc. complete :
9.96.1 300x16 mm
46
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating
not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required250X10
colour or shade, with necessary screws
314
-
-
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating
not less than grade AC 10 as per IS : 1868) transparent or dyed to required
colour or shade, with necessary screws etc. complete :
9.100.1 125 mm
314
-
-
Providing and fixing aluminium hanging floor door stopper, ISI marked, (twin rubber) anodised
(anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed
to required colour and shade, with necessaryTwin rubber stopper
38
-
-
Renewing glass panes, with putty and nails wherever necessary
including racking out the old putty:
14.5.1 Float glass panes of nominal thickness 4 mm (weight
not less than 10kg/sqm)
109.53
-
-
Providing and laying water proofing treatment in sunken portion of
WCs, bathroom etc., by applying cement slurry mixed with water
proofing cement compound consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with
water proofing cement compound @ 0.253 kg/ sqm. This layer
will be allowed to air cure for 4 hours.
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with
water proofing cement compound @ 0.126 kg/sqm. This layer
will be allowed to air cure for 4 hours followed with water curing
for 48 hours.
(The rate includes preparation of surface, treatment and sealing of
all joints, corners, junctions of pipes and masonry with polymer mixed
slurry.)
32.14
-
-
Providing and laying water proofing treatment on roofs of slabs by
applying cement slurry mixed with water proofing cement compound
consisting of applying:
(a) after surface preparation, first layer of slurry of cement @ 0.488
kg/sqm mixed with water proofing cement compound @ 0.253
kg/sqm.
(b) laying second layer of Fibre glass cloth when the first layer is
still green. Overlaps of joints of fibre cloth should not be less
than 10 cm.
(c) third layer of 1.5 mm thickness consisting of slurry of cement
@ 1.289 kg/sqm mixed with water proofing cement compound
@ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will
be allowed to air cure for 4 hours followed by water curing for 48
hours. The entire treatment will be taken upto 30 cm on parapet
wall and tucked into groove in parapet all around.
(d) fourth and final layer of brick tiling with cement mortar (which
will be paid for separately.
(For the purpose of measurement the entire treated surface will be
measured.)
272.5
-
-
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating
coat of neat cement.
13.9.1 12 mm cement plaster
272.5
-
-
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps,
i/c making good the walls etc. concealed pipe, including painting
with anti corrosive bitumastic paint, cutting chases and making good
the wall : internal work
18.11.1 15 mm dia nominal bore
100
-
-
Providing and fixing G.I. pipes complete with G.I. fittings including trenching
and refilling etc.external work 15 mm dia nominal bore
200
-
-
Providing and fixing brass stop cock of approved quality :
18.16.1 15 mm nominal bore
4
-
-
Providing and fixing ball valve (brass) of approved quality, High or low
pressure, with plastic floats complete :
18.18.1 15 mm nominal bore
12
-
-
Providing and fixing uplasticised PVC connection pipe with brass unions45 cm length
18.21.2.1 15 mm nominal bore
8
-
-
Providing and placing on terrace (at all floor levels) polyethylene water
storage tank, IS : 12701 marked, with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank.
4000
-
-
Providing and fixing C.P. brass bib cock of approved quality conforming to
IS:8931 :
18.49.1 15 mm nominal bore
8
-
-
Providing and fixing C.P. brass long body bib cock of approved quality
conforming to IS standards and weighing not less than 690 gms.
18.51.1 15 mm nominal bore
8
-
-
Providing and fixing C.P. brass stop cock (concealed) of standard design
and of approved make conforming to IS:8931.
18.52.1 15 mm nominal bore
6
-
-
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and
threading the pipe and making long screws, including excavation,
refilling the earth or cutting of wall and making good the same complete
wherever required :
18.47.1 15 mm nominal bore
10
-
-
Providing and fixing white vitreous china pedestal type water closet
(European type W.C. pan) with seat and lid, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever), conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and making good the walls and
floors wherever required :
17.2.1 W.C. pan with ISI marked white solid plastic seat and lid
4
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass
pillar taps, 32 mm C.P. brass waste of standard pattern, including
painting of fittings and brackets, cutting and making good the walls
wherever require:White Vitreous China Wash basin size 630x450 mm with
a single 15 mm C.P. brass pillar tap
9
-
-
Providing and fixing water closet squatting pan (Indian type W.C.
pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and
fixtures complete, including cutting and making good the walls and
floors wherever required:
17.1.1 White Vitreous china Orissa pattern W.C. pan of size
580x440 mm with integral type foot rests
4
-
-
Providing and fixing white vitreous china flat back or wall corner type
lipped front urinal basin of 430x260x350 mm and 340x410x265 mm
sizes respectively with automatic flushing cistern with standard flush
pipe and C.P. brass spreaders with brass unions and G.I clamps
complete, including painting of fittings and brackets, cutting and
making good the walls and floors wherever required :Range of four urinal basins with 10 litre white P.V.C.
automatic flushing cistern
1
-
-
Providing and fixing mirror of superior glass (of approved quality) and
of required shape and size with plastic moulded frame of approved
make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm
8
-
-
Providing and fixing PTMT towel rail complete with brackets fixed to
wooden cleats with CP brass screws with concealed fittings
arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width
78 mm and effective height of 88 mm, weighing not less
than 190 gms.
3
-
-
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement
: 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement :
1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm
nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse
sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),
inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3
coarse sand) finished with floating coat of neat cement and making
SUB HEAD : 19.0 DRAINAGE 364
Codechannels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) finished with a floating
coat of neat cement complete as per standard design :
19.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover
with frame (light duty) 455x610 mm internal dimensions,
total weight of cover and frame to be not less than 38 kg
(weight of cover 23 kg and weight of frame 15 kg) :
19.7.1.1 With common burnt clay F.P.S. (non modular)
bricks of class designation 7.5
5
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal
ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
(i) Single socketed pipes.
12.41.1 75 mm diameter
60
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal
ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,110 mm diameter
30
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain water pipes conforming
to IS : 13592 Type A, including jointing with seal ring conforming to
IS : 5382, leaving 10 mm gap for thermal expansion.
12.42.1 Coupler
12.42.1.1 75 mm
5
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain water pipes conforming
to IS : 13592 Type A, including jointing with seal ring conforming to
IS : 5382, leaving 10 mm gap for thermal expansion.110 mm
5
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain water pipes conforming
to IS : 13592 Type A, including jointing with seal ring conforming to
IS : 5382, leaving 10 mm gap for thermal expansion.12.42.3 Single tee with door
12.42.3.1 75x75x75 mm
3
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain water pipes conforming
to IS : 13592 Type A, including jointing with seal ring conforming to
IS : 5382, leaving 10 mm gap for thermal expansion.12.42.3 Single tee with door110x110x110 mm
4
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain water pipes conforming
to IS : 13592 Type A, including jointing with seal ring conforming to
IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5°
12.42.5.1 75 mm bend
5
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/
accessories for unplasticised Rigid PVC rain water pipes conforming
to IS : 13592 Type A, including jointing with seal ring conforming to
IS : 5382, leaving 10 mm gap for thermal expansion.12.42.5.2 110 mm bend
5
-
-
Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered wall
surface to prepare the surface even and smooth complete
2897.09
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade :
13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm
over and including priming coat of exterior primer applied
@ 2.20 kg/10 sqm)
974.41
-
-
Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :
13.41.1 New work (two or more coats) over and including water
thinnable priming coat with cement primer
1922.68
-
-
Finishing with Deluxe Multi surface paint system for interiors and
exteriors using Primer as per manufacturers specifications :Painting wood work with Deluxe Multi Surface Paint of required shade. Two
or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied
@0.75 ltr/10 sqm of approved brand and manufacture
108.36
-
-
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre
long with S.S. triangular plate to Eureopean type W.C. of quality and make as
approved by Engineer - in - charge.
5
-
-
Finishing with Deluxe Multi surface paint system for interiors and
exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to
give an even shade. Two or more coat applied @ 0.90 ltr/
10 sqm over an under coat of primer applied @ 0.80 ltr/
10 sqm of approved brand and manufacture
89.01
-
-
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement
: 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal
size) over 75mm thick bed of dry brick ballast 40 mm nominal size,
well rammed and consolidated and grouted with fine sand, including
necessary excavation, levelling & dressing & finishing the top smooth.
66.54
-
-
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay
F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement
mortar 1:4 (1 cement : 4 fine sand).
110.9
-
-
Supplying and applying bituminous solution primer on roof and / or wall surface
at 0.24 litre per sqm.
85.92
-
-
Providing and fixing in position collapsible steel shutters with vertical
channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm
size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia
steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,
handles, including applying a priming coat of approved steel primer.
7.56
-
-
Providing and Laying of Interlocking Concrete Blcok Pavements having thickness 60
mm as per drawing and Technical Specification Clause 1504
284
-
-
Excavation in soil in Hilly Area by mechanical means Without useinng Dozer
including cutting and trimming of side slopes and disposing of excavated earth
with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause
1603.1
648
-
-
Excavation in foundation for retaining, breast walls etc, in all types of soils and
rocks including all lead, lift and disposal of surplus material as per direction of
engineer - in - charge, as per drawing and technical specifications Clause 305.1 of
MORD Specifiction
97.6
-
-
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls,
retaining walls, parapets, scuppers, etc. including supply of all material, labour,
T&P and royaltiies etc. complete as per drawing and technical specifications
Clauses 702, 704, 1202 & 1203 of MORD Specifiction
409.46
-
-
Random Rubble Stone Masonry laid Dry, in breast walls, retaining walls, etc.
including supply of all material, labour, T&P and royaltiies etc. complete as per
drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD
Specifiction
96.92
-
-
Hand Packed stone filling in back of wallls including cost of all materials, royality,
T&P etc. complete as per direction of Engineer-in- charge. (As per PWD
Uttarakhand specifications
288.15
-
-