Rural Works Department Tender
View complete overview of Uttarakhand RWD Tender
Rural Works Department - RWD Tender
Civil And Construction
Building Construction
Eprocure
Opening Date27 Jul 2024
Closing Date9 Aug 2024
Tender Amount₹ 1,09,84,760.55 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 2,82,000Document Cost
₹ 4,720Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RES_73985_1Bid Award Id
ViewTender No
334/RWD/NIT/2024-25Tender Authority
Rural Works Department ViewPurchaser Address
-Website
http://https://res.uk.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Providing and laying vitrified floor tiles in different sizes (thickness to be
specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS: 15622, of approved make, in all colours and shades,
laid on 20 mm thick cementmortar 1:4 (1 cement: 4 coarse sand), jointing
with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with
white cement and matching pigments etc., complete.Size of Tile 600x600 mm
1125.71
-
-
Providing and fixing lst quality ceramic glazed wall tiles conforming to
IS: 15622 (thickness to be specified by the manufacturer), of approved
make, in allcolours, shades except burgundy, bottle green, black of any
size as approved by Engineer-in-Charge, in skirting, risers of steps and
dados, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse
sand) and jointing with grey cement slurry @ 3.3kg per sqm, including
pointing in white cement mixed with pigment of matching shade complete.
1417.04
-
-
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300
mm or more (thickness to be specified by the manufacturer), of 1st quality
conforming to IS: 15622, of approved make, in colours White, lvory, Grey,
Fume Red Brown, laid on 20 mm thick cement motar 1:4 (1 Cement: 4
Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including
grouting the joints with white cement and matching pigments etc., complete.
60.8
-
-
13.80 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
3050.45
-
-
13.41 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
3514.13
-
-
13.46 Finishing walls with Acrylic Smooth exterior paint of required shade : 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
742.99
-
-
13.48 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :13.48.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
354.1
-
-
Designing, fabricating, testing, installing and fixing in position Curtain
Wallwith Aluminium Composite Panel Cladding, with open grooves for
linear as well as curvilinear portions of the building, for all heights and all
levels etc. including:
(a) Structural analysis & design and preparation of shop drawings for
pressure equalisation or rain screen principle as required, proper drainage
of water to make it watertight including checking of all the structural and
functional design.
(b) Providing, fabricating and supplying and fixing panels of aluminium
composite panel cladding in pan shape in metalic colour of approved
shades made out of 4 mm thick aluminium composite panel material
consisting of 3 mm thick FR grade mineral core sandwiched between
two Aluminium sheets (each 0.5 mm thick). The aluminium composite
panel cladding sheet shallbe coil coated, with Kynar 500 based PVDF /
Lumiflon based fluoropolymer resin coating of approved colour and shade
on face #1and polymer (Service) coating on face #2 as specified using
stainless steel screws, nuts, bolts, washers, cleats, weather silicone
sealant, backer rods etc.
(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot
Dip Galvanised with serrations and serrated washers to arrest the wind
load movement, fasteners, SS 316 Pins and anchor bolts of approved
make in SS 316, Nylon separators to prevent bi-metalic contacts all
complete required to perform as per specification and drawing The item
includes cost of all material & labour component, the cost of all mock
ups at site, cost of all samples of the individual components for testing
in an approved laboratory, field tests on the assembled working curtain
wall with aluminium composite panel cladding, cleaning and protection of
the curtain wall with aluminium composite panel cladding tillthe handing
over of the building for occupation. Base frame work for ACP cladding
is payable under the relevant aluminium items. The Contractor shall
provide curtain wall with aluminium composite panel cladding, having
all the performance characteristics all complete ,
as per the Architectural
drawings, as per item description, as specified, as per the approved shop
drawings and as directed by the Engineer-in-Charge. However, for the
purpose of payment, only the actual area on the external face of the
curtain wall with Aluminum Composite Panel Cladding (including width of
groove) shall be measured in sqm. up to two decimal places.
411
-
-
21.5 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
595.35
-
-
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to
a height of 5 m above floor level, over first class kail wood strips 25x6 mm
with 10 mm gap in between and reinforced with rabbit wire mesh fixed to
wooden frame (frame work to be paid separately):
12.31.1 Flat surfaces
119.07
-
-
Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading DSR 9.51.2
22.5
-
-
14.5 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: 14.5.1 Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
29.7
-
-
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25.2
362.85
-
-
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
802.54
-
-
Reinforced cement concrete work in beams, suspended floors, roofs
having slope up to 15° landings, balconies,shelves, chajjas, lintels, bands,
plain window sills,staircases and spiral stair cases above plinth level up
to floor five level, excluding the cost of centering, shuttering, finishing and
reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-lll) derived
from natural sources :
3 graded stone aggregate 20 mm nominal size
derived from natural sources).
1.28
-
-
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. DSR 5.9.5
13.46
-
-
Marble stone flooring with 18 mm thick marble stone, as per sample of
marble approved by Engineer-in-charge, over 20 mm (average) thick
base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed
with grey cement slurry, including rubbing and polishing complete with:Udaipur green marble
55.62
-
-
Chequerred precast cement concrete tiles 22 mm thick in footpath &
courtyard, jointed with neat cement slurry mixed with pigment to match
the shade of tiles, including rubbing and cleaning etc. complete, on 20
mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
Ordinary cement without any pigment
Light shade pigment using white cement
160.5
-
-
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars. DSR 5.22.3
200.96
-
-
22.6 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:
(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/
sqm mixed with water proofing cement compound @ 0.253 kg/sqm.
(b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.
(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.
(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.
For the purpose of measurement the entire treated surface will be measured
588.32
-
-
Filling available excavated earth (excluding rock) in trenches, plin sides of foundations etc. in layers not exceeding 20cm in de consolidating each deposited layer by ramming and watering, up to 50 m and lift upto 1.5 m. DSR 2.25
10.45
-
-
11.24 Extra for pre finished nosing to treads of steps of marble stone.
57.6
-
-
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
62.06
-
-
9.21 Providing and fixing ISI marked flush door shutters conforming to IS :
2202 (Part I) non-decorative type, core of block board construction with
frame of 1st class hard wood and well matched commercial 3 ply
veneering with vertical grains or cross bands and face veneers on both
faces of shutters:
9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges
with necessary screws
49.13
-
-
9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic
coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed
to required colour or shade, with necessary screws etc. complete :
36
-
-
9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised
(anodic coating not less than grade AC 10 as per IS : 1868),
transparent or dyed to required colour or shade, with nuts and screws
etc. complete :: 250x16x5 mm
36
-
-
9.100 Providing and fixing aluminium handles, ISI marked, anodised (anodic
coating not less than grade AC 10 as per IS : 1868) transparent or dyed
to required colour or shade, with necessary screws etc. complete :
9.100.1 125 mm
36
-
-
9.101 Providing and fixing aluminium hanging floor door stopper, ISI marked,
anodised (anodic coating not less than grade AC 10 as per IS : 1868)
transparent or dyed to required colour and shade, with necessary screws
etc. complete.9.101.2 Twin rubber stopper
36
-
-
Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to plinth
level:
1:2:4 (1 cement :2 coarse sand (zone-l|l) derived from
natural sources: 4 graded stone aggregate 20mm nominal
size derived from natural sources)
3.58
-
-
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.16.91.2 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.
240
-
-
Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section
made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever reqired) of appropriate dimension, EPDM gasket, hardware, SS
304 grade fasteners of minimum 8 mm dia with countersunk head,comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 :
Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash &
mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between
frame and adjacent finishedwall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of
Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit
with /without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from Government
Engineering Institute, to be provided by the manufacturer for :
() Sites with basic wind speed 45 m/sec as per IS 875 - Part 3
(ii) Sites with structure height more than 20m for all wind speedsUsing R4 series with frame (64 mm & above)
x (45 mm & above) & sash (44 mm & above)
x (55 mm & above) with zinc alloy (zamak)
powder coated handle on every panel along
with multi-point locking system (Height above
1.8m).
214.38
-
-
15.12 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.1 Of area 3 sq. metres and below
214.38
-
-
21.18 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
15.75
-
-
Grouting the joints of flooring tiles having joints of 3 mm width, using
epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10
kg of hardener and 0.20 kg of resin per kg), including filling/ grouting and
finishing complete as per direction of Engineer-in-charge.ize of Tile 600x600 mm
1125.71
-
-
Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface.8.25.4 12 mm thick
298.74
-
-
9.7 Description 9.6.2 9.6.3 12 mm thick pre-laminated board (decorative lamination on both sides) grade-1, medium density flat pressed, three layer particle board FPT- lor graded wood particle board FPT- |, conforming to IS:3087, bonded with BWP type synthetic resin adhesive as per IS: 848 and pre-laminated conforming to IS: 12823, Grade 1, Type- || marked. 12 mm thick one side Pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) grade-1, medium density flat pressed, three layer particle board FPT- Ior graded wood particle board FPT-1 conforming to IS: 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-laminated conforming to IS : 12823, Grade-1, Type Il marked. Providing and fixing panelling or panelling and glazing in panelled or panelled and glazedshutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Particle Board 12 mm thick Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS: 3087 marked
298.74
-
-
13.68 French spirit polishing : 13.68.1 Two or more coats on new works including a coat of wood filler
298.74
-
-
Providing and fixing white viterous china water closet squatting pan indian type orissa pattern W.C pan with P.V.C low level flushing cistern with manually controlled device DSR 17.1.1
4
-
-
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
10
-
-
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern
6
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter
40
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75mm diameter
27.2
-
-
Providing and fixing M.S. holder bat clamps of approved design to C.I. or S.C.I. rain water pipes embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and cost of cutting holes and making good the walls etc. : 100 mm diameter
32
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer External work in Charge. 15 mm nominal outer dia Pipes
60
-
-
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 20 mm dia nominal bore. DSR 18.12.2
100
-
-
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse Inside size 60x45x50 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg): With F.P.S. bricks with class designation 75 with inside plastering 12 mm th of cement mortar 1:3 finished smooth with a floating coat of neat cement. DSR 18.32.1
6
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. internal work - Exposed on wall 15 mm nominal outer dia Pipes
50
-
-
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15mm nominal bore. DSR 18.50.1
16
-
-
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15mm nominal bore. DSR 18.52.1
28
-
-
Providing and placing on terrace (at all floor levels) polyethylene w tank ISI : 12701 marked with cover and suitable locking arrangement tank ISI : 12701 marked with cover and suitable locking arrangem necessary holes for inlet, outlet and overflow pipes but without fitti base support for tank. DSR 18.48
2000
-
-
Providing and fixing gun metal gate valve with C.I. wheel of appro (screwed end) 25 mm nominal bore. DSR 18.17.1
4
-
-
providing and fixing wash basin with C.I brackets,brass pillar taps 32 white viterous china wash basin size 630x450mm. DSR 17.7.1
11
-
-
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm
11
-
-
Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia
8
-
-
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1
-
-
Evaluation Notes How It Works ?