Public Works Department Tender
View complete overview of Uttarakhand PWD Tender
Public Works Department - PWD Tender
Civil And Construction
Drainage Work
Eprocure
Opening Date24 Jan 2024
Closing Date5 Feb 2024
Tender AmountRefer Documents
Costs
EMD
₹ 13,10,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_pwd_68171_1Bid Award Id
ViewTender No
213/41-M Dated 18-01-2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://pwd.uk.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling of Structures
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per
Technical Specification Clause 202. Cement Concrete
1878
-
-
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD
Specifiction
465.15
-
-
Providing concrete for P.C.C. grade M 10 plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix (1:3:6)
1759
-
-
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction
620
-
-
Cement plum Masonry with 40% plum & 60% 1:3:6 cement concrete including supply of all material, labour, T&P etc. required for proper completion of the work. As per drawings and technical specifications Clause 802, 803, 1202 & 1203 of MORD Specifiction
110
-
-
Providing concrete for P.C.C. grade M 20 plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix (1:2:4)
1175
-
-
Providing and fixing 10x10x10cm Cobbel stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge.
1600
-
-
Providing and fixing 20x10x10 cm block (cobble stone) hand cut and chisel dressed on paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement:4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer -in-charge.
3100
-
-
Providing and Laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80 mm as per drawings and Technical Specification Clause 1504.
5200
-
-
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
2355
-
-
Pointing with cement mortar (1:3) on brickwork as per drawing and technical specification Clauses 613.3 and 1204
3080
-
-
Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203 Brick masonry in 1:4 cement mortar
201.76
-
-
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
16454.4
-
-
Painting Two Coats on New Concrete Surfaces
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification
Clause 1701
176
-
-
Providing and fixing of retro reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of Type XI retro reflective sheeting fixed over 3mm/4mm thick Aluminium composite material sheet vide clause801.3, depending on the size of the sign fixed over back support frame ofmin 25 x 25 x 3mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designedfoundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cmbelow ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.
-
-
-
900 mm equilateral triangle
23
-
-
600 x 450 mm Rectangle
14
-
-
Direction and Place Identification Signs upto 0.9 sqm Size Board. Providing and erecting direction and place
identification retro-reflectorised sign as per IRC :67 made of Type XI retroreflectivesheeting, vide clause 801.3, fixed over Aluminium compositematerial sheet with overall thickness of 4mm with area not exceeding 0.9 sqm fixed over back support frame of min 35 x 35 x 3mm Angle mountedon a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60cm, 60 cm below ground level as per approved drawing.
24.02
-
-
Road Delineators
Providing and fixing of Standard Metal Delineator consisting of minimum retro reflective unit exposed area of 330 sqcm, full cube corner micro prismatic non-metallic retro reflective sheeting on each side conforming with IRC 67 and meeting the coefficient of retro reflection values as per ASTM D 4956 Type XI table specification with pure polyester powder coating with the minimum thickness of powder coating of not less than 40 micron. The posts shall have ellipsoidal or circular design with
the height of the pole shall be 800 to 900 mm above the ground with about 200 to 300 anchored with PCC M-15 onto the ground. The front and back faces of the delineator should be curved with a radius of not more than 200 mm and with delta angle (or central angle of curve) lying between 20o and 30 o, to increase the visibility of the delineator for vehicles moving in continuous curves. The delineator shall have sufficient arrangement to make the reflective sheets vandal-proof. Including all
test report and warranties as per IRC 67 and IRC 79.
25
-
-
Road Studs / Cat Eye:
Providing and fixing of single mould twin shank reflective road studs of ‘category A’ Raised pavement markers made out of poly carbonate/ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values shall be as given in the detailed specifications and the product shall conform to ASTM D4280. The raised pavement marker shall also meet all the testing conditions of ASTM D4280 and fixed to the road surface using the adhesive recommended by the manufacturer. Two cylindrical Polymer Shanks of not less than 20 mm diameter and not less than 30 mm length shall be molded in the RPM body.
The reflective raised pavement markers shall also confirm to the MORTH circular No RW / NH. 33023/10/ 97-DO.III and the length ,height and width of the body shall not be less than 100 mm, 15 mm and 90 mm and base of marker shall be flat within 1.3 mm and outermost faces of configuration of marker shall not deviate more than 1.3 mm from a flat surface. The marker shall support a load of 13635 Kg tested in
accordance with ASTM D4280. The marker shall withstand flexural strength of 909 kgf force in accordance with ASTM D4280. Marker lenses shall be moulded of Polycarbonate or methyl methecrylate conforming to ASTM D788. The area of each retro reflectory surface shall not be less than 13.0 sq.cm. The slope or retro –reflectory surface shall be 35 + 5 degree to base. Each reflector shall have a CILnot less than values specified in table 1 of MORTH Section 800 page no. 353 and
should accompany two year warranty for satisfactory field performance from the manufactu
400
-
-
Solar Road Studs:
Providing and fixing Solar Powered Road Studs (Rectangular) of size not less than 100mm x 100 mm x 10 mm or (Circular) of dia 130+/- 6mm and height 30 +/- 2mm (with 8 super bright LEDs for long visibility from distance greater than 800 m) having twin shank and body made of aluminium alloy and poly carbonate material which shall be absolutely weather resistant and strong enough to support a load of 13635 kg tested in accordance with ASTM D 4280 and water resistance as per IP 65 in
accordance with IS 12063:1987, fixed to the road surface using adhesives and the procedure recommended by the manufacturer as per Clause No. 804.6 and 804.7 of MORTH specifications.
130
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements