Public Works Department Tender
View complete overview of Uttarakhand PWD Tender
Public Works Department - PWD Tender
Civil And Construction
Road Construction
Eprocure
Opening Date10 Feb 2024
Closing Date22 Feb 2024
Tender Amount₹ 24,85,149 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 56,000Document Cost
₹ 2,360Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_pwd_69273_1Bid Award Id
ViewTender No
188/nivida soochna dt 05/04/2024Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://pwd.uk.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S/O 300W LED Flood light having PDC housing 300W ± 5W, Input voltage AC 140 to 270V V AC with auto resetting safety Cut-off, Power Factor 0.95, Driver Efficiency 85%, IEC compliance confirming to IEC-61347-1 & IEC 61347-2-13IEC615447, 610-3-2, Driver should also have 5 Kv inbuild and 10Kv External surge protection, Short /Double phase protection, THD (1)10% to 90% RH working Temp-10 C to + 50C, System Efficacy 110 Lm/Watt.
8
-
-
... More
S/O hot dip Galvanised Steel OCTAGONAL POLE height = 4m, Top OAF= 70 mm, Bottom OAF-130, Thickness-3 mm, Base Plate-200 x 200x 12mm, PCD-200mm
6
-
-
... More
S/O foundation accessories set-each set consists of 4 nos of M 16x 600 J bolts plus 10% templates
6
-
-
... More
S/O 600mm single arm bracke, standard tiype 36.3/mm OD pipe
6
-
-
... More
S/O 45 W LED Flood light having PDC housing 45 W ± 2W, Input voltage AC 140 to 270V V AC with auto resetting safety Cut-off, Power Factor 0.95, Driver Efficiency 85%, IEC compliance confirming to IEC-61347-1 & IEC 61347-2-13IEC615447, 610-3-2, Driver should also have 5 Kv inbuild and 10Kv External surge protection, Short /Double phase protection, THD (1)10% to 90% RH working Temp-10 C to + 50C, System Lumen 4900± 2%, System Efficacy 110 Lm/Watt Lm 9 front NABL lab, LED Make- CREE/NICHI / OSRAM/LUMILEDS CRS is mandatory should have vailed ISO
6
-
-
... More
S/O hot dip Galvanised Steel OCTAGONAL POLE height = 6m, Top OAF= 70 mm, Bottom OAF-130, Thickness-3 mm, Base Plate-200 x 200x 12mm, PCD-200mm
7
-
-
... More
S/O foundation accessories set-each set consists of 4 nos of M 20x 750J bolts plus 10% templates
7
-
-
... More
S/O 1000mm single arm bracke, standard tiype 36.3/mm OD pipe
7
-
-
... More
S/O 70 W LED Flood light having PDC housing 70 W ± 2W, Input voltage AC 140 to 270V V AC with auto resetting safety Cut-off, Power Factor 0.95, Driver Efficiency 85%, IEC compliance confirming to IEC-61347-1 & IEC 61347-2-13IEC615447, 610-3-2, Driver should also have 5 Kv inbuild and 10Kv External surge protection, Short /Double phase protection, THD (1)10% to 90% RH working Temp-10 C to + 50C, System Lumen 4900± 2%, System Efficacy 110 Lm/Watt Lm 9 front NABL lab, LED Make- CREE/NICHI / OSRAM/LUMILEDS CRS is mandatory should have vailed ISO
7
-
-
... More
S/O hot dip Galvanised Steel OCTAGONAL POLE height = 7m, Top OAF= 70 mm, Bottom OAF-130, Thickness-3 mm, Base Plate-200 x 200x 12mm, PCD-200mm
23
-
-
... More
S/O foundation accessories set-each set consists of 4 nos of M 16x 600 J bolts plus 10% templates
23
-
-
... More
S/O 1000mm Double arm bracke, standard tiype 36.3/mm OD pipe
23
-
-
... More
S/O 90 W LED Flood light having PDC housing 90 W ± 2W, Input voltage AC 140 to 270V V AC with auto resetting safety Cut-off, Power Factor 0.95, Driver Efficiency 85%, IEC compliance confirming to IEC-61347-1 & IEC 61347-2-13IEC615447, 610-3-2, Driver should also have 5 Kv inbuild and 10Kv External surge protection, Short /Double phase protection, THD (1)10% to 90% RH working Temp-10 C to + 50C, System Lumen 4900± 2%, System Efficacy 110 Lm/Watt Lm 9 front NABL lab, LED Make- CREE/NICHI / OSRAM/LUMILEDS CRS is mandatory should have vailed ISO
46
-
-
... More
Centralized Auto On off Timer, 12 w Three Phase Automatic Strell light cubical panel feeder box with Astronomical Timer Complete
4
-
-
... More
S/L of 4x 6 sq mm Al. armoured cable
500
-
-
... More
S/L of 4x 10 sq mm Al. armoured cable
50
-
-
... More
S/L of 50 mm dia GI pipe
400
-
-
... More
Supplying and drawing 3 x 1.5 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
300
-
-
... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of
2.7 metre long etc. with charcoal/ coke and salt as required.
5
-
-
... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and
re-filling as required.
450
-
-
... More
Supplying and laying of 63 mm dia DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,
jointing etc. in the existing trench, complete as required.
100
-
-
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole and neutral poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
26
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements