Pradhan Mantri Gram Sadak Yojana Tender
View complete overview of Uttarakhand PMGSY Tender
Pradhan Mantri Gram Sadak Yojana - PMGSY Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date3 Aug 2018
Closing Date29 Aug 2018
Tender Amount₹ 512 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 13,20,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_CCUK_66191_34Bid Award Id
ViewTender No
URRDA_1046_18072018Tender Authority
Pradhan Mantri Gram Sadak Yojana ViewPurchaser Address
-Website
http://http://omms.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
R/W & B/W
3027.49
-
-
X-Drainage/Drainage structure
5001.81
-
-
Construction of R.R. stone masonary in cement mortar 1:5 including supply of all materials,labour, T&P,Royalty etc required for proper completion of work as directed by Engineer-in-charge and MORD Specification for clause 700&1604.
-
-
-
R/W&B/W
1893.55
-
-
X-Drainage/Drainage structure
2436.92
-
-
Petty works like perapet etc.
56.93
-
-
Construction of R.R. stone masonary laid dry including bond stones, supply of all materials, labour,T&P & Royalty etc.required for proper completion of work as directed by Engineer-in-charge MORD Specification Clause 700&1604
-
-
-
R/W&B/W
2748.15
-
-
X-Drainage/Drainage structure
706.6
-
-
HP stone filling in back of structures including supply of all material, labour, T&P, royalty etc. required for proper completion as directed by Engineer-in-charge and MORD Specification Clause 1604.7
-
-
-
R/W & B/W
1742.45
-
-
X-Drainage/Drainage structure
963.02
-
-
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 150 mm x 150 mm mesh (woven diagonally)including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each (crate size 3.00m * 1.50m* 1.25m) as directed by Engineer-in-charge and MORD Specification 1301
436.88
-
-
Providing weep holes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full width of the structures with slope of 1(V):20(H) towards face complete as directed by Engineer-in-charge and MORD Specification Clause 1206.6
1237.32
-
-
Providing and laying of concrete for plain concrete in open foundations for structures including supply of all materials, labour, T&P, royalty etc. required for proper completion of work as directed by Engineer-in-charge and MORD Specification Clause 800,1202,1203 for . P.C.C grade M 10. Nominal mix
-
-
-
X-Drainage/Drainage straucture
285.89
-
-
Providing and laying of concrete for plain concrete for structures including supply of all materials, labour,T&P,royalty etc. required for proper completion of work as directed by Engineer-in-charge and MORD Specification for 800 . P.C.C grade M 20. Nominal mix 1;2;4
-
-
-
Petty works like perapet etc.
2.48
-
-
Providing and laying of concrete for plain concrete for structures including supply of all materials, labour,T&P,royalty etc. required for proper completion of work as directed by Engineer-in-charge and MORD Specification Clause 800 1202 and for P.C.C grade M 25. Nominal mix
-
-
-
X-Drainage/Drainage structure
14.89
-
-
Providing and laying of concrete for reinforced concrete for structures including supply of all materials, labour, t&p, shuttering, centering , royalty etc. required for proper completion of work as directed by Engineer-in-charge and MORD Specification Clause 800.R.C.C.grade M 25 Nominal Mix
-
-
-
X-Drainage/Drainage structure
138.63
-
-
15 mm thick Plastering with 1:6 cement mortar including supply of all materials, labour,T&P, royalty etc. required for proper completion of work as directed by Engineer-in-charge and MORD Specification Clause 613.4
323.4
-
-
Supplying, cutting , and placing of HYSD bar reinforcement in substructure/superstructure complete (IS1786:2008 clause no. 1.6) Steel shall not be from rerolling plants and shall conform to relevent IS Code including supply of all materials, labour,T&P, royalty etc. required for proper completion of work as directed by Engineer-in-charge as per MORD Specification clause 1000
-
-
-
Sub structure
114.57
-
-
Reinforced cement concrete M15 grade kilometer stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing , directed by Engineer-in-charge and MORD Specification clause 1703. (precast).( km stone)
12
-
-
5th km Stone As per standard design (precast)
2
-
-
200mt Stone As per standard design (precast)
48
-
-
Providing & fixing of PMGSY Logo Board at starting point, end point and at every 2 Km distance of road length as per standard drawing duly painted and written and as directed by Engineer in charge/ as per MORD Specification 1701.
7
-
-
Providing and Fixing 'Logo' of PMGSY Project Providing and fixing of typical PMGSY Title informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
1
-
-
Providing & fixing of Citizen Information Board with PMGSY Logo at starting or prominent location (where maximum no. of citizens can view the detail of the road) as per standard drawing dully painted and written as directed by Engineer in charge/ as per MORD Specification 1701.
1
-
-
Providing & fixing of Semi reflective Traffic Sign Boards (cautionary, mandatory & informatory) as per standard drawing duly painted and written as directed by Engineer in charge. as per IRC/ MORD Specification 1701.
42
-
-
Providing & fixing of Maintenance Information Board with PMGSY Logo at starting or prominent location (where maximum no. of citizens can view the detail of the road) as per standard drawing dully painted and written as directed by Engineer in charge/ as per IRC/ MORD Specification Clause 1701
1
-
-
Construction of (200x200x300)mm size Reference piller / level piller in RR Mud Motar stone masonary and plaster in 1:6 on three side and top on each pegs (40nos/km)includi white washing and eletter writting supply of all material labour T&P etc required for proper completion of work as per drawing & directed by engineer in charge Technical specification.
438
-
-
Construction of (300x300x400)mm size Back Cutting piller in RR Mud Motar stone masonary and plaster in 1:6 on three side and top on each pegs (40nos/km)includi white washing and eletter writting supply of all material labour T&P etc required for proper completion of work as per drawing & directed by engineer in charge Technical specification.
438
-
-
Construction of (400x400x600)mm size Job piller in RR Mud Motar stone masonary and plaster in 1:6 on three side and top on each pegs (40nos/km)includi white washing and eletter writting supply of all material labour T&P etc required for proper completion of work as per drawing & directed by engineer in charge Technical specification.
2
-
-
White washing two coats on parapet walls and tree trunks including preparation of surface by cleaning scraping etc. as per technical specifications Clause 1916 of MORD Specification clause1704
323.4
-
-
Cement plum masonry with 40%plump & 60% 1:3:7 cement concrect including supply of all matirail labours T &P etc required for proper complatication of the work
1547.6
-
-
Development of Dumping place & slop Protection - Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 150 mm x 150 mm mesh (woven diagonally)including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each (crate size 3.00m * 1.50m* 1.25m) as directed by Engineer-in-charge and MORD Specification 1301
-
-
-
Earthwork in Excavation for wire crates required for debris disposal
371.66
-
-
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 150 mm x 150 mm mesh (woven diagonally)including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each (crate size 3.00m * 1.50m* 1.25m) as directed by Engineer-in-charge and MORD Specification 1301
1858.16
-
-
EMERGENT MAINTENANCE
-
-
-
Major Slip Clearance in all Type of Soil ,rock and boulders including cost of all material , machine,T&p etc required for proper compeletion of work as per mord specification of work 1611
-
-
-
Ist Year
876
-
-
Iind Year
788
-
-
Deploying Hydraulic excavator of 0.90cum bucket for clearence of Major slip in all type of soil rock and boulders including its operator ,pol, and all other charges required for proper compeletion of work
-
-
-
Ist Year
33
-
-
Iind Year
30
-
-
Providing and laying of boulder apron laid in wire crate with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and techniacal specification 1301
-
-
-
Ist Year
44
-
-
Iind Year
40
-
-
Coolie Walling including supply of all material, labour, T&P,royalty etc. required for proper completion of the work,as directed by Engineer-in-charge and as per PWD specifications 8.90 (For opening communication only)
-
-
-
Ist Year
22
-
-
Iind Year
19.8
-
-
Maintenance Activities: PBMC
-
-
-
Maintenance under PBMC for 1] Trimming of grass and weeds from the shoulders/berms and disposing off the same to suitable locations as per technical specifications Clause 1914. 2] Maintenance of road side Drains including minor slip clearence , reshaping ,deepening and ,regrading ,as well as catch water drains as per technical specification Clause 1907.
3]Maintenance of shoulders to the required level by filling/cutting the soil and its compacting including disposal of the surplus material in approved muck disposal points as per specification clause 1903 .
4] Maintenance of scuppers & Culverts by way of clearing, Cleaning, Erosion repair, repairs to cracks, parapet walls and Protection works as per drawing and technical specification Clasue 1908.
5] Maintenance of Causeway by way of minor Surface repairs, replacing Guide Posts, repair of flood gauges, removal of debris, providing boulders and protection work and painting as per technical specification Clause 1909. 6] Maintenance of road signs by way of cleaning and repainting of mandatory / requlatory / cautionary / informatory and place identifications sign board as per drawings and technical specification Clause 1910.
7] Maintenance of 200 metre km stone by way of refiting of tilted stones repairing with cement mortar, cleaning, repairing and lettering on 200 metre km stone and 5th km stone as per drawing and technical specification Clause 1912.
8] Two coat white washing on parapet walls of CD work ,edge stones, tree truncks, and prominent rock patches on hill sides including preparation of surface by cleaning scraping etc. as per technical specifications Clause 191.
-
-
-
1st year
10.95
-
-
2nd year
10.95
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements