Power Transmission Corporation Of Uttarakhand Limited Tender

View complete overview of Uttarakhand PTCUL Tender

Power Transmission Corporation Of Uttarakhand Limited - PTCUL Tender

Works
Civil And Construction
Civil Works Others
Building Construction
Eprocure
Opening Date29 Dec 2023
Closing Date18 Jan 2024
Tender Amount₹ 26,77,292.1 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position cement concrete of specified grade including the cost of centering shuttring - All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

15

-

-

... More
Providing and laying in position of reinforcement cement concrete, including the cost of cenetering, shuttering, finishing. All work up to plinth level; 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).

25

-

-

... More
Providing and laying in position cement concrete, including the cost of cenetering, shuttering, finishing. All work up to plinth level; 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

20

-

-

... More
Providing and laying in position of reinforcement cement concrete, including the cost of cenetering, shuttering, finishing. All work up to plinth level; 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).

5

-

-

... More
Providing and laying in position cement concrete, 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).

60.5

-

-

... More
Bricks work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 Cement : 4 coarse sand).

70

-

-

... More
12 mm cement plaster of mix : 1:4 (1 cement: 6 coarse sand).

510

-

-

... More
MS Steel bar including supply of material, cutting, bending, moulding etc complete in all respect as per direction of engineer in charge

2.7

-

-

... More
Supply and fixing of rolling shutters made of 80x1.25 mm machine rolled laths of approved make, MS Lath interlocked together through its entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets and arrangement for inside and outside locking with push and pull operation, work complete in all respect.

15

-

-

... More
Top cover for rolling shutters 1.25 mm thick

4

-

-

... More
27.5 cm long wire spring grade No. 2 for rolling shutters

4

-

-

... More
Ball bearing for rolling shutters

2

-

-

... More
Extra for mechanical devices chain and cranked operation for operating rolling shutters: exceeding 10.00 sqm and up to 16.80 sqm area of door.

3

-

-

... More
Wiring for light point/ fan point/ exhaust fan point with 1.5 Sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with piono type switch, suitable size MS box and earthing the point with 1.5 Sqmm FRLS insulated copper conductor single core cable etc as required. (Group A)

11

-

-

... More
Dismantaling of old and damaged security fencing base boundary wall and chain link mesh fencing by cutting of damaged chain link fencing, intermediate post and shifting of dismantaled old damaged and rusted chain link fecing at suitable place as per instruction of engineer in charge.

34

-

-

... More
Structural steel works riveted, bolted or welded in built up sections, trusses, Heavy sections and of approved steel primer including cost of material,labour and T&P complete in all respect as per direction of engineer in charge.

1

-

-

... More
Installation of corrgated G S sheet 1.00 mm thick roofing including vertical curved surface fixed with polymer coated J or L hocks bots and nuts 8 mm diameter with bitumen and G.I. impet washers or with G.I. limper washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal vertical or curves surfaces excluding the cost of purlins, rafters and trusses but including cutting to size and shape wherever requred and all consumables materal labour and T&P complete in all respect as per the direction of engineer incharge

135

-

-

... More
White washing with lime to give an even shade : 13.37.1 New work (three or more coats) sqm 32.45

440

-

-

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).

210

-

-

... More
Finishing walls with Premium Acrylic Smooth interior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).

230

-

-

... More
Installation, testing and commissioning of celing fan of reputed make, including wiring the down rods of standard length upto 30 cm) with 1.5 sq mm FRLS PVC insulated copper cover on the fan box etc required as per site conditions including cost of all consumables, material, labour and T&P complete in all respect as per the direction of engineer incharge.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.