Power Transmission Corporation Of Uttarakhand Limited Tender
View complete overview of Uttarakhand PTCUL Tender
Power Transmission Corporation Of Uttarakhand Limited - PTCUL Tender
Civil And Construction
Electrical Generators And Transformers
Building Construction
Electrical and Electronics
Eprocure
Opening Date27 Dec 2023
Closing Date30 Jan 2024
Tender Amount₹ 13,77,00,000 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 27,54,000Document Cost
₹ 23,600Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_PTCUX_66923_1Bid Award Id
ViewTender No
CE/GZR-18/2023-24Tender Authority
Power Transmission Corporation Of Uttarakhand Limited ViewPurchaser Address
-Website
http://https://www.ptcul.org
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(iv) Supply of Oil sampling Bottle, Stainless Steel 2 ltrs capacity.
4
-
-
... More
(B)145kV Equipments:-
(i) Supply of 145 K.V Circuit Breaker (3 phase), along with support structure, clamps, mounting nut bolts & washers
2
-
-
... More
(ii) Supply of 145 K.V 2000A, 40KA horizontal double brake Isolator (3PH, motorized type), without earth switch (metallic & insulator) along with clamps, mounting nut bolts & washers
2
-
-
... More
(iii) Supply of 145 K.V 2000A, 40KA horizontal centre brake Tandem Isolator (3PH), without earth switch (metallic & insulator) along with clamps, mounting nut bolts & washers
2
-
-
... More
(iv) Supply of 145 KV (5 core) Current transformer (1 ph) ratio (400/200/1A, 0.2S class), without junction box along with clamps.
4
-
-
... More
(iv) Supply of 132 K.V Lightening Arrester (1ph) along with surge counter, clamps, mounting nut bolts & washers
3
-
-
... More
(vi) Supply of 145 kV Bus Post Insulator
12
-
-
... More
(vii) Supply of Junction Box for 145 KV,CT
1
-
-
... More
(C)33kV Equipments (i) Supply of 33KV circuit Braker (VCB) along with clamps, mounting nut bolts & washers
2
-
-
... More
(ii) Supply of 33KV CT (3 Core) (800/400/1A, 0.2S class) along with clamps, mounting nut bolts & washers without junction box
4
-
-
... More
(iii) Supply of 33KV bus Isolator along with clamps, mounting nut bolts & washers without earthlink
3
-
-
... More
(iv) Supply of 33KV LA along with clamps, mounting nut bolts & washers
6
-
-
... More
(v) Supply of 33 kV Bus Post Insulators/Solid core insulator
6
-
-
... More
(vi) Supply of Junction Box for 33kV CT
2
-
-
... More
(D)132 kV Control and Relay panel:-
(i) Supply of 132/33 K.V Transformer Protection panel for (HV & LV) 110Volt DC.
1
-
-
... More
(ii) Supply of 132/33 K.V circuit breaker control panel for 40MVA transformer without auto reclose 110Volt DC.
1
-
-
... More
(E)Control cable & XLPE cable:-
(i) Supply of 2 core, 2.5 mm², aromoured copper control cable
2
-
-
... More
(ii) Supply of 4 core, 2.5 mm², aromoured copper control cable (4*2.5)mm control cable
2
-
-
... More
(iii) Supply of 6 core, 2.5 mm², aromoured copper control cable
2
-
-
... More
(iv) Supply of 10 core, 2.5 mm², aromoured copper control cable
1.5
-
-
... More
(v) Supply of 33KV Al XLPE cable size 3 core x 400 sqmm
1
-
-
... More
(vi) Supply of outdoor type termination kit suitable for 3x400 sqmm XLPE cable
4
-
-
... More
(F)Main & Auxiliary structure and earthing material:- (i) Supply of Main & Auxiliary Gal. Lattice structure, Nut & Bolts and Washer with foundation Anchor Nut & Bolts and Washer of 132 KV Column 2 Nos, 132KV Beam 1 Nos, & ATM,BTM Structure and structure for 132 KV 3 Nos LA, 132 KV 4 Nos Isolator ( Standard & Tandam ),132 KV 3 Nos C.T, 132 KV 2 No Post Insulator & 33KV Structure CCR, CGM, 33 KV 2 Nos Isolator, 33 KV 3 No C.T, 33 KV 6 No L.A.
12
-
-
... More
(i) Supply of MS flat earth strip 50x6 mm
3
-
-
... More
(ii) Supply of MS round 40 mm for earth mat.
4
-
-
... More
(iii) Supply of 40mm 03 meter deep driven pipe electrode (treated pit)
8
-
-
... More
(iv) 3 meter deep driven pipe electrode
6
-
-
... More
(v) Supply of Copper Bond of size 12mm dia 500mm long rope type having copper lugs on both the ends.
30
-
-
... More
(G)Bus bar material & insulator:-
(i) Supply of Yoke plate suitable for twin ACSR Moose conductor size 340x90x16 mm for 70KN disc insulator complete along with all accessories as per given sample.
6
-
-
... More
(ii) Supply of Bolted type tension fitting for ACSR Moose conductor along with all accessories 5 U bolted type complete as per given sample
12
-
-
... More
(iii) Supply of Bolted type tension fitting for ACSR Panther conductor along with all accessories 5 U bolted type complete as per given sample
15
-
-
... More
(iv) Supply of Suspension Fitting for Panther Conductor
6
-
-
... More
(v) Supply of Spacer clamp suitable for twin Moose bus to single Moose dropper made of LM6 aluminium alloy without any blow holes & burs as per sample.
15
-
-
... More
(vi) Supply of Spacer for twin Moose conductor for bus bar
15
-
-
... More
(vii) Supply of Fired type C wedge clamp with lock as ACSR Moose to Moose, Moose to Panther and Panther to Panther conductor
100
-
-
... More
(viii) Supply of 132KV post insulator clamp (Run through type) for ACSR Panther conductor
10
-
-
... More
(ix) Supply of 33 KV post insulator clamp (Run through type) for ACSR Moose conductor
10
-
-
... More
(x) Supply of Phase Plate (set of three)
50
-
-
... More
(xi) Supply of 132 KV CT Clamp for ACSR Panther conductor
10
-
-
... More
(xii) Supply of 132 KV C.B. clamp for ACSR Panther conductor
10
-
-
... More
(xiii) Supply of 132KV Isolator clamp for ACSR Panther conductor
30
-
-
... More
(xiv) Supply of 132 KV Tandem Isolator clamp for ACSR Panther conductor
15
-
-
... More
(xv) Supply of 132 KV LA Clamp for ACSR panther condcutor
5
-
-
... More
(xvi) Supply of 33 KV CT 5 U bolted clamp for ACSR Moose conductor
10
-
-
... More
(xvii) Supply of 33 KV CB pad type clamp for ACSR Moose conductor
10
-
-
... More
(xviii) Supply of 33kV Isolator pad type clamp for ACSR Moose conductor
10
-
-
... More
(H)Material for Line:-
(i) Supply of ACSR Panther conductor allowing 1.5% sag, jumpers and wastage etc as per approved Technical Specification.
4
-
-
... More
(ii) Supply of 120 KN Disc Insulator for tension fitting.
250
-
-
... More
(iii) Supply of 70 KN Disc Insulator for tension fitting.
60
-
-
... More
(iv) Supply of Compression type Single Tension fitting (120 KN) for ACSR panther conductor including Dead end with steel portion, Aluminium portion, Jumper cone, arching horn & D sackle with nuts & bolts of jumper cone.
15
-
-
... More
(v) Supply of Vibration damper for ACSR panther conductor.
15
-
-
... More
(I)Other Misc. items:-.
(i) Supply of Fire fighting equipment 45 ltr foam type
2
-
-
... More
(ii) Supply of Fire fighting equipment 20 kg CO2 type
1
-
-
... More
(iii) Supply of Fire fighting equipment 10 kg ABC type
4
-
-
... More
(iv) Supply of Mechanical foam type fire extingusher 9 ltrs
2
-
-
... More
(v) Supply of Water mist & CAF fire extinguisher backpack capacity 50 ltr.
1
-
-
... More
(vi) Supply of 6 Fire Buckets with stand
1
-
-
... More
(vii) Supply of Sand Drums (Half size) filled with sand
5
-
-
... More
(viii) Supply of Fire Hut & Sand Pit (as per existing hut & pit)
1
-
-
... More
(ix) Supply of Aluminium binding wire
10
-
-
... More
(x) Supply of Rubber mats (size 3'x6')
5
-
-
... More
(xi) Supply of Aluminium strip tape
10
-
-
... More
(xi) Supply of Rail suitable for 40MVA T/F of desired length from approch road to the foundation of transformer.
850
-
-
... More
Annexure -I I (A) (Erection) Foundation work for Transformer, its HV & LV bay equipments, gantery colums and cable trenches, civil foundation drawing, electrical layout plant and cable schedule:- (i) Work of preparation of civil foundation drawing for 132/33KV power transformer, all 132 KV equipments for HV bay of transformer (LA, CT, Bus Isolator, Tandem Isolator and Circuit Breaker etc.), 33 KV equipments for LV Bay of transformer (LA, CT, Isolator, Circuit Breaker etc) and gantery colums with anchor bolts as per the requirements of sites and type of soil.
1
-
-
... More
(ii) Preparation of Electrical layout plan/earth - mat/ section elevations drawing.
1
-
-
... More
(iii) Preparation of Cable Schedule/Inter-Panel Wiring Drawing.
1
-
-
... More
(iv) Earth work excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or pits of any size, including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed, including all leads & lifts.
800
-
-
... More
(v) Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering. All work up to plinth level 1:2:4 (1 Cement, 2 Coarse sand, 4 graded stone aggregate 20 mm nominal size.)
100
-
-
... More
(vi) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level 1:4:8 ( 1 Cement, 4 Coarse sand, 8 graded stone aggregate 40 mm nominal size.)
85
-
-
... More
(vii) Providing and laying in position specified grade of reinforced cement concrete, including the cost of centering and shuttering, finishing. All work up to plinth level 1:1.5:3 ( 1 Cement, 1.5 Coarse sand, 3 graded stone aggregate 20 mm nominal size.) & also fixing of rail on transformer foundation.
95
-
-
... More
(viii) First class brick work in 1:4 cement and sand mortar including cost of material, labour and T&P required for proper completion of work.
300
-
-
... More
(ix) 12mm Plaster in 1:4 ratio with cement and sand including cost of material, labour and T&P required for proper completion of work.
800
-
-
... More
(x) Filling available excavted earth (excluding rock) in trenches, plinths, side edges of foundation etc. in layers not exceeding 20cm in dept, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m
200
-
-
... More
(xi) Iron work in plain such as reinforced necessary including bending for proper completion of work and including supply of steel bar and authorized over lapping shall be measured (As per drawing)
4
-
-
... More
(xii) Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). DSR 11.20.1
20
-
-
... More
(xiii) RCC cable trenches with trench covers (all sections) including all type of crossing and all metallic work to support cables and trench covers : trench size (1.0x0.80x0.80 mtr.)/ (1.10x1.0x1.0 mtr) & fixing of angle size 40x40x5mm in interval of 1 mtr, laying of proper size of cable tray and fixing of cables with metal bracket.
200
-
-
... More
(B)Earthing & earth mat work:-
(i) Work of design & laying of earthmat by excavaion of earth work in mixed soil for extended switchyard by M.S. Rod 40 mm dia. (excluding cost of rod)
4
-
-
... More
(i) Earthing of all equipments & structure cutting, bending, weding etc at 2 point with earth mat by 50x6 mm earth strip in required shape & size also includes cost of painting with one coat of red oxide paint and two coats of enamaled green paint over it, Nuts & Bolts, earthing strip connecting to exsiting strip in cable trench and civil work as per site incharge. (excluding cost of MS strip)
3
-
-
... More
(ii) 40mm 03 meter deep driven pipe electrode (treated pit)
8
-
-
... More
(iii) 3 meter deep driven pipe electrode
6
-
-
... More
(C) Erection, Testing & commissioning and jumpering /clamping of following items with structure, making all electricals with complete work of electrical inter-connections, ferruling, dressing of cables etc. work of making proper earthing including painting in earth strip up to the satisfication of concerned Engineer incharge incuding cost of all T&P and labour :-
(i) Erection of 40 MVA, 132/33KV, Three phase Transformer including first filling of oil, alongwith Fibre Optic Temperature Measurement System complete with all associted accessories. Work also includes unloading at site, shifting from site to plinth and proper stacking of transformer on plinth as per drawing of OEM. (Excluding foundation work)
1
-
-
... More
(ii) Supervision of testing & commissioning of 40 MVA (132/33kV) Transformer with direct temprature measurement system, Nitrogen Injection, Fire prevention cum Extinguishing system along with online DGA.
5
-
-
... More
(iii) ETC of Nitrogen Injection Fire Prevention & extinguishing system for transformer.
1
-
-
... More
(iv) ETC of Online DGA Multigas Type for 132/33kV 40MVA Transformer as per Technical specification
1
-
-
... More
(v) Erection of 132 KV Current Transformer without junction box
3
-
-
... More
(vi) Erection of 132 KV Circuit Breaker
1
-
-
... More
(vii) Erection of 132 KV Lightening Arrestor
3
-
-
... More
(viii) Erection of 132 KV Isolator
2
-
-
... More
(ix) Erection of 132 KV Tandem Isolator
2
-
-
... More
(x) Erection of Junction Box for 132kV CTs
1
-
-
... More
(xi) Erection of 132/33KV CB control panel of 40 MVA T/F
1
-
-
... More
(xii) Erection of 40MVA Transformer Protection panel for HV & LV
1
-
-
... More
(xiii) Erection of 33 KV Current Transformer
3
-
-
... More
(xiv) Erection of 33 KV Circuit Breaker
1
-
-
... More
(xv) Erection of 33 KV Lightening Arrestor
6
-
-
... More
(xvi) Erection of 33 KV Isolator
3
-
-
... More
(xvii) Erection of Junction Box for 33kV CT's
1
-
-
... More
(xviii) Erection of 132KV post insulator
12
-
-
... More
(xix)Erection of 33KV Post insulator with run through clamp at LV side of Transformer.
6
-
-
... More
(D) Erection of Bus bar material, bus bar, main & auxiliary structure etc:-.
(i)ACSR Panther conductor
1000
-
-
... More
(ii)ACSR Moose conductor (Provided by the PTCUL free of cost)
500
-
-
... More
(iii) Disc Insulator 120 KN.
250
-
-
... More
(iv)Disc Insulator 70 KN.
60
-
-
... More
(v)Yoke plate suitable for twin ACSR Moose conductor size 340x90x16 mm for 70KN disc insulator complete along with all accessories as per given sample.
6
-
-
... More
(vi)Bolted type tension fitting for single ACSR Moose conductor along with all accessories 5 U bolted type complete as per given sample
12
-
-
... More
(vii)Bolted type tension fitting for singe ACSR Panther conductor along with all accessories 5 U bolted type complete as per given sample
15
-
-
... More
(viii)Suspension Fitting for Panther Conductor
6
-
-
... More
(ix)Phase Plate (set of three)
50
-
-
... More
(x)Super structure erection of ATM,BTM,CCR, column Beam, 33 KV and 132 KV CT, PT. LA, Post Insulator, Tandam & Isolator structure all work above ground level including extension with proper tightening of Nut & Bolt work include cost of labour and T&P.
12
-
-
... More
(xi)Laying, stringing, tesioning, clamping, jointing, etc. of 3 phase bus bar complete with single/double ACSR panther/ moose conductor including hoisting of single/double tension fitting of insulator and all other assoceries on 132 KV 1 No Bay & 33 KV 1 No Bays.
1
-
-
... More
(E) Stringing of line conductor work:- (i)Cutting, Laying, Stringing, Tensioning, Clamping, Jointing etc. complete with single ACSR Panther conductor including hoisting of insulators and single or double fittingsof insulator and fitting of vibration damper etc for complete route of 3 phase.
3
-
-
... More
(F)Laying of control & XLPE cable:_
(i)Laying of 2 core x 2.5 sqmm control cable
2
-
-
... More
(ii)Laying of 4 core x 2.5 sqmm control cable
2
-
-
... More
(iii)Laying of 6 core x 2.5 sqmm control cable
2
-
-
... More
(iv)Laying of 10 core x 2.5 sqmm control cable
1.5
-
-
... More
(v) Laying of 3 phase, 3 core x 400 sqmm power cable on cable tray with proper fixing by providing bracket & cable tie.
1
-
-
... More
(vi)33 KV outdoor cable termination suitable for 3x400 sqmm
4
-
-
... More
(G)Testing, Lighting work and cable tray:-
(i)Complete terminaion, interconnection, ferrulling and dressing of control cable between equipment to equipment in outdoor swich yard and indoor control room all equipments other then transformer.
1
-
-
... More
(ii)Complete testing of transformer (open circuit, short circuit, vector group, stability test, insulaion test etc as per manufacturer manual & IS) including all connected accessories before to energize. Work also includes submitting the test results copy (jointly signed) to the department in 03 copies.
1
-
-
... More
(iii)work of complete testing of 145kV CB, CTs, LAs & 36kV CB, CTs, LAs etc as per manufacturer manual & IS including all connected equipment's before to energize, work also includes submitting the test results copy (jointly signed) to the department in 03 copies.
1
-
-
... More
(iv)Complete testing of Transformer oil from CPRI, NTPC etc. including Collection of oil samples.
4
-
-
... More
(v)Providing & laying of cable tray, cable glands, termination clamping, lugs, cable marking & ferruling etc, including providing of all material as required.
3
-
-
... More
(v)Providing & Fixing of 2 Nos ACDB outdoor type of cubical size 90x60x30 cm having four no MCCB of rated ampears 10,16,36, 65 & 3 phase-Natural Bus-Bar with Switch Disconnector 100 Amp, 415Volt AC-23amp FSB-100 Make Havells ISI mark etc. along with locking arrangment.
2
-
-
... More
(vi)Providing and fixing of switchyard LED lights complete (100W Philips, Havells, Bajaj etc.) complete work including making AC point, cable laying, bend pipe and fixing AC Junction Box 16 & 6 AMP MCB inbuild with all labour, material and T&P etc.
5
-
-
... More
(H)Misc. & other works:-
(i)Work of development of land by earth work excavation, levelling of soil by mech./ manual method
180
-
-
... More
(ii)Providing & fixing of wire mesh radiator guard of appropriate height at LV side of 40MVA T/F work also includes fabrication of channel, angle and grounting of angles in cement concrete ratio of 1:2:4 then applying one coat of red oxide primer & two coat of bus green paint, complete work including all labour, material and T&P etc.
1
-
-
... More
(iii)Providing & fixing G.I. chain link febric fencing of required with in mesh size 50x50 mm including strengthening with 4 mm dia wire or nuts bolts and washers as required complete per the direction of Engineer-in charge 16.70.1 Made of GI wire of dia 4mm
350
-
-
... More
(iv) Fabrication & fixing MS/GI angle 75x75x6 mm alongwith all fastenng items nut, bolts, washers as supporting structure for chain link fencing including all modification work such as welding, cutting, painting & fabrication work as per instruction of site incharge. (Provided by the PTCUL)
500
-
-
... More
(v) Providing & fixing MS/GI angle 35x35x5 mm alongwith all fastenng items nut, bolts, washers as supporting structure for chain link fencing including all modification work such as welding, cutting, painting & fabrication work as per instruction of site incharge.
1
-
-
... More
(vi) Providing & fixing of Barbed wire on runners of chain link fencing, complete work as per instruction of site incharge, including all labour, material and T&P etc.
1
-
-
... More
(vii)Providing & fixing of MS flat 35x5 & 75x6 mm alongwith all fastening items nuts bolts washers as supporting structure for chain link fencing including all modification work such as welding, cutting & fabrication work as of instruction site incharge.
1
-
-
... More
(viii)Fabrication of MS/GI angle (Provided by the PTCUL) for making support in "Y" shape to string the razor wire & concertina coil fancing by cutting, welding, bendng, straightening, drilling & fixing on wall and painting with one coat of red oxide and two coat of best quality enamel paint (Silver/ Aluminium paint) after rubbing, cleaning of angles with embrey paper after fabrication.
200
-
-
... More
(viii)Providing and fixing punched tape concertina coil 600/ 700 mm dia 10 meter openable length, having approx 7-8 nos rounds per meter length upto 3 m height of wall with existing ange iron "Y" shaped, stud tied with GI staples and GI clips to retain horizontal, including necessary bolts or GI barbed wire tied to angle iron complete in all respect including all cost of material, labour and T&P for proper completion of work. (excluding cost of MS angle)
150
-
-
... More
(ix) Providing & fixing of MS frame gate including fabrication, modification, welding, bending, cutting of MS flat 75x5 mm MS square 25x5 mm, MS bar alongwith fastening items etc., civil grouting work also included as per instruction of site incharge.
1
-
-
... More
(x) Fire fighting equipment 45 ltr foam type
2
-
-
... More
(xi)Fire fighting equipment 20 kg CO2 type
1
-
-
... More
(xii)Fire fighting equipment 10 kg ABC type
4
-
-
... More
(xiii)Mechanical foam type fire extingusher 9 ltrs
2
-
-
... More
(xiv)Water mist & CAF fire extinguisher backpack capacity 50 ltr.
1
-
-
... More
(xv)6 Fire Buckets with stand
1
-
-
... More
(xvi)Sand Drums (Half size) filled with stand
5
-
-
... More
(xvii)Fire Hut & Sand Pit (as per existing hut & pit)
1
-
-
... More
(I)Laying of Stones Gravels (40mm) for 40MVA Transformer & Bays:-
(i)Work of Excavation / removing and levelling of switchyard work also include grass treatment by digging, cleaning and removing the root of vegetation.
40
-
-
... More
(ii)Work of providing and laying the 40mm grevels in 50mm thickness and 20mm grevels over it 150mm thickness is spread all through the switchyard
40
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements