Power Transmission Corporation Of Uttarakhand Limited Tender

View complete overview of Uttarakhand PTCUL Tender

Power Transmission Corporation Of Uttarakhand Limited - PTCUL Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date30 Dec 2023
Closing Date15 Feb 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
420 KV Current Transformer (1Ph) with Clamp (5 core= 2 metering and 3 protection core) Ratio 2000/1000/500A/1A without Junction Box

3

-

-

... More
Junction Box for 420 kV CT

1

-

-

... More
400 kV Control & Relay panels (a) Transformer/Reactor protection panel

1

-

-

... More
BMK as per site requirement

1

-

-

... More
Lighting Junction Box as per site requirement

1

-

-

... More
1.1 kV Aromoured power cables (Al) and aromoured control cables (Copper) Control cable copper (PVC). a)     2.5mm2, 2 core armoured cable

2.5

-

-

... More
b)    2.5mm2, 4 core armoured cable

2

-

-

... More
c)     2.5mm2, 10 core armoured cable

2

-

-

... More
d)    2.5mm2, 14 core armoured cable

1

-

-

... More
Power cable Aluminium (PVC) a) 3.5c x 70 Sq.mm

0.1

-

-

... More
b) 4c x 6 Sq. mm

0.5

-

-

... More
Supply of Cable Glands, Lugs & Straight through joints for power & control cables (as per site location)

1

-

-

... More
Grounding/Earthing system (a) M.S. Flat 75x12 mm strip for earthing.

2

-

-

... More
(b) M.S. Flat 50x6 mm strip for earthing etc.

0.5

-

-

... More
(c)40mm MS rod

3

-

-

... More
400 KV Bus post insulator solid core type

14

-

-

... More
Providing of galvanized pipe structure with bolts and nuts as per drawing of Pantograph Isolator, C.T, double break Isolator and bus post insulator as per existing pipe structure.

13

-

-

... More
Providing of clamps for joint connection of 4”IPS Aluminium tube (as per site requirement)

14

-

-

... More
Copper bond for 7/3.15 mm GS Earthwire or 7/10 SWG

22

-

-

... More
Phase plate 1 set for three ph.

4

-

-

... More
Danger plate.

8

-

-

... More
Illumination system/Lighting Arrangement (a) switch yard lighting points HPSV lamp 250 W

6

-

-

... More
(b) switch yard LED Lights

6

-

-

... More
Fire Fighting equipment. (a) CO2 type Fire Extinguisher 20 Kg (Trolly Type)

4

-

-

... More
(b) ABC type 10 Kg

4

-

-

... More
(c)6 fire bucket with stand

1

-

-

... More
(d) Fire hut and sand pit

1

-

-

... More
Supply and erection of 8mm/10mm/12mm MS steel bar (Ms Iron cold twisted bar) for foundation work (as per requirement of foundation drawing)

6

-

-

... More
Civil Work for 50 MVAR Reactor Bay Excavation of soil for making foundation of 420 kV circuit breaker,Panograph Isolator, Double break isolator, Post insulator and 420 KV CT etc.

115

-

-

... More
Prepare of RCC foundation & plinth and “U” bolt by providing and laying in position specified grade of reinforced cement, concrete, including the cost of centering, shuttering, finishing, all work up to plinth level 1:1.5:3(1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) of 400 KV Circuit breaker (as per drawing). After completion of said work, back filling near foundation of the CB by soil.

16

-

-

... More
Prepare of RCC Foundation plinth and “U” bolt by providing and laying in position specified grade of reinforced cement, concrete, including the cost of centering, shuttering, finishing, all work up to plinth level 1:1.5:3(1cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) for single phase 400 KV CT (3 nos.) (as per drawing). After completion of said work, back filling near foundation of the CT by soil.

10

-

-

... More
Prepare of RCC Foundation plinth and “U” bolt by providing and laying in position specified grade of reinforced cement, concrete, including the cost of centering, shuttering, finishing, all work up to plinth level 1:1.5:3(1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) for Pantograph Isolator (2 sets) (as per drawing). After completion of said work, back filling near foundation of Isolator by soil.

15.3

-

-

... More
Prepare the RCC foundation plinth and “U” bolt by providing and laying in position specified grade of reinforced cement, concrete, including the cost of centering, shuttering, finishing, all work up to plinth level 1:1.5:3(1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) for C type Standard double break Isolator (1 set) (as per drawing). After completion of said work, back filling near foundation of Isolator by soil.

14

-

-

... More
Prepare the RCC foundation plinth and “U” bolt by providing and laying in position specified grade of reinforced cement, concrete, including the cost of centering, shuttering, finishing, all work up to plinth level 1:1.5:3(1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) for 14Nos. Post support insulator (as per drawing). After completion of said work, back filling near foundation of the PI by soil.

36

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

11

-

-

... More
Construction of trench (size 400 mm width with minimum depth 750 mm and trench cover size is 500 mm x 400 mm cover using MS angle (45*45*6) mm and steel reinforcement dia 12 mm and C.C 1:2:4 with all material, T&P etc.

195

-

-

... More
Erection of 420 kV CT (1 phase) with junction box

3

-

-

... More
Erection of 420 kV circuit breaker along with support structure on the foundation 3Ph completely including interconnection of wiring between poles to poles.

1

-

-

... More
Erection of 420 kV Pantograph Isolator without earth switch 3Ph completely.

1

-

-

... More
Erection of 420 kV Pantograph Isolator with one earth switch 3Ph completely.

1

-

-

... More
Erection of 400 kV bus post insulator on the foundation completely.

14

-

-

... More
Erection of C type double break Isolator with earth switch and interconnection of wiring between poles to poles completely.

1

-

-

... More
Providing and fixing of Galvanised anchor bolts for foundation of circuit breaker, isolators, CT and bus post insulator including nuts & washer complete. (as per site requirement)

95

-

-

... More
Erection, Commissioning and Other Related works 400 kV Control & Relay panels Reactor/Transformer protection panel including wiring, Erection & commissioning of local control/relay panel for proper remote and relay operation of 50MVAR reactor with all indications, and all necessary work required to proper operation including complete testing of reactors, equipments control and relay panel, indication and all local remote switches.

1

-

-

... More
BMK as per site requirement

1

-

-

... More
Lighting Junction Box as per site requirement

1

-

-

... More
1.1 kV Aromoured power cables (Al) and aromoured control cables (Copper) Control cable copper (PVC) .a) 2.5mm2, 2 core armoud cable.

2.5

-

-

... More
b)    2.5mm2, 4 core armoud cable.

2

-

-

... More
c)     2.5mm2, 10 core armoud cable.

2

-

-

... More
d)    2.5mm2, 14 core armoud cable.

1

-

-

... More
Power cable Aluminium (PVC) a) 3.5c x 70 Sq.mm

0.1

-

-

... More
b) 4c x 6 Sq. mm

0.5

-

-

... More
Erection of Cable Glands, Lugs & Straight through joints for above power & control cables (as per site location)

1

-

-

... More
Grounding/Earthing system (a) M.S. Flat 75x12 mm strip for earthing.

2

-

-

... More
(b) M.S. Flat 50x6 mm strip for earthing etc.

0.5

-

-

... More
(c)40mm MS rod

3

-

-

... More
Erection of galvanized pipe structure with bolts and nuts as per drawing of Pantograph Isolator, C.T, double break Isolator and bus post insulator as per existing pipe structure.

13

-

-

... More
Erection of 4”IPS aluminium tube between the equipments, including providing of jointing sleeve and pin, welding, cutting, bending and transportation from store to switch yard as per the site requirement.

235

-

-

... More
Erection of clamp, connector, conductor and hardware fittings as per the site requirement.

1

-

-

... More
Termination of all cable with ferrule and cable glands in junction box of all equipments (circuit breaker, 400 KV CT and isolator etc.) and control/relay panel in switch yard and control room including all interconnection of master slave etc. and interlocking wiring completely for proper operation of bay.

1

-

-

... More
Testing of all equipments as per IEC/IS standard

1

-

-

... More
Submitting the relevant drawing in hard & soft copy of all the equipments with their arrangements/connections for proper commissioning of tendered work.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.