Power Transmission Corporation Of Uttarakhand Limited - PTCUL Tender
Civil And Construction
Building Construction
Eprocure
Opening Date24 Sep 2024
Closing Date23 Oct 2024
Tender AmountRefer Documents
Costs
EMD
₹ 13,00,000Document Cost
₹ 17,700Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PTCUX_76240_1Tender No
CE/GZR-13/2024-25Tender Authority
Power Transmission Corporation Of Uttarakhand Limited ViewPurchaser Address
-Website
http://https://www.ptcul.org
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Procurement of 120 K.V Lightening Arrester (1ph)
3
-
-
132/33 K.V 40 MVA Transformer relay & control panel for (HV & LV) operating volatge 110 Volt DC
1
-
-
33KV circuit Braker (SF6) 3 ph along with mounting struture, nut bolts & washers (110volt DC supply)
1
-
-
33KV CT (800/400/1A) 3 core accuracy class 0.2 without Junction box
3
-
-
33 KV PT (Single phase) without junction box
3
-
-
33KV bus Isolator along with mounting nut bolts & washers without earthlink
2
-
-
30 KV LA along with surge counter & mounting nut bolts & washers
6
-
-
Junction box for 33 KV CT/PT
2
-
-
RTCC panel for 40 MVA, 132/33 KV Transformer
1
-
-
145 KV Bus Support/ Post Insulator
8
-
-
Armoured Control cable & XLPE cable
-
-
-
2 core X 2.5 mm² Copper control cable
1.5
-
-
4 core X 2.5 mm² Copper control cable
2
-
-
6 core X 2.5 mm² Copper control cable
2
-
-
10 core X 2.5 mm² Copper control cable
2
-
-
Power cable Aluminium size 3.5 core x 35 sqmm
0.4
-
-
Main & Auxiliary structure and earthing material
-
-
-
Main & Auxiliary Gal. Lattice structure with Nut & Bolts and Washer of 132 KV Column, 132KV Beam - ATM,AXM, BTM & BXM, structure for 132 KV LA, 132 KV Isolator,132 KV C.T & Structure for 33 KV column & beam CCR, CGM, 33 KV Isolator, 33 KV C.T, 33 KV PT, 33 KV L.A.
19
-
-
GI flat earth strip 50x6 mm
1
-
-
MS round 40 mm for earth mat
2
-
-
Pipe electrode meter (treated pit)
2
-
-
Copper Bond of size 12mm dia 500mm long rope type having copper lugs on both the ends.
40
-
-
Copper strip size as per requirement
15
-
-
Bus bar material & insulator
-
-
-
ACSR Panther conductor
1
-
-
ACSR Moose conductor
1.5
-
-
Over shielded earth wire (7/10 SWG)
0.3
-
-
Disc Insulator 120 KN.
400
-
-
Disc Insulator 70 KN.
80
-
-
Yoke plate suitable for twin ACSR Moose conductor size 340MMx90MMx16MM for 70KN disc insulator complete along with all accessories as per given sample
12
-
-
Bolted type tension fitting for ACSR Moose conductor along with all accessories 5 U bolted type complete as per given sample
30
-
-
Bolted type tension fitting for ACSR Panther conductor along with all accessories 5 U bolted type complete as per given sample
6
-
-
Suspension Fitting for Panther Conductor
6
-
-
33 KV Suspension fitting suitable for twin moose conductor
3
-
-
Tension fitting for earth wire (7/10 SWG)
6
-
-
Supply of Fired type C wedge clamp with lock as ACSR Moose to Moose, Moose to Panther and Panther to Panther conductor as per site requirement
30
-
-
Supply of PG clamp for ACSR Moose to Moose, Moose to Panther & Panther to Panther conductor.
100
-
-
132 KV LA Clamp for ACSR panther condcutor
5
-
-
33 KV CT Clamp for ACSR twin Moose conductor
10
-
-
33 KV CB Clamp for ACSR twin Moose conductor
10
-
-
33 KV Isolator Clamp for ACSR twin Moose conductor
15
-
-
33 KV PT clamp
5
-
-
33 KV LA Clamp for ACSR panther condcutor
5
-
-
33 KV Post insulator run through clamp suitable for twin moose conductor
5
-
-
Phase Plate (set of three)
20
-
-
GI Anchor bolt & nut with washer
1400
-
-
132 KV Suspension fitting for moose conductor
6
-
-
Spacer for twin moose bus bar
12
-
-
Other Misc. items.
-
-
-
Lighting Junction Box
1
-
-
GI Cable tray 2.5 mtr length 75 mm wide
30
-
-
GI Cable tray 2.5 mtr length 150 mm wide
60
-
-
GI Cable tray 2.5 mtr length 300 mm wide
60
-
-
Rubber mats (size 3'x6')
3
-
-
Rail suitable for 40MVA T/F of desired length from approch road to the foundation of transformer.
850
-
-
Erection Work
-
-
-
Procurement of 145 KV Hybrid switchgear outdoor type (Including CT) Double Bus Bar, along with support structure, clamps, mounting nut bolts & washers including supervision servicec charges of erection, testing & commissioning (total mximum 6 man days including 1 visit)
1
-
-
Procurement of 120 K.V Lightening Arrester (1ph)
3
-
-
132/33 K.V 40 MVA Transformer relay & control panel for (HV & LV) operating volatge 110 Volt DC
1
-
-
33KV circuit Braker (SF6) 3 ph along with mounting struture, nut bolts & washers (110volt DC supply)
1
-
-
33KV CT (800/400/1A) 3 core accuracy class 0.2 without Junction box
3
-
-
33 KV PT (Single phase) without junction box
3
-
-
33KV bus Isolator along with mounting nut bolts & washers without earthlink
2
-
-
30 KV LA along with surge counter & mounting nut bolts & washers
6
-
-
Junction box for 33 KV CT/PT
2
-
-
RTCC panel for 40 MVA, 132/33 KV Transformer
1
-
-
145 KV Bus Support/ Post Insulator
8
-
-
2 core X 2.5 mm² Copper control cable
1.5
-
-
4 core X 2.5 mm² Copper control cable
2
-
-
6 core X 2.5 mm² Copper control cable
2
-
-
10 core X 2.5 mm² Copper control cable
2
-
-
Power cable Aluminium size 3.5 core x 35 sqmm
0.4
-
-
Main & Auxiliary Gal. Lattice structure with Nut & Bolts and Washer of 132 KV Column, 132KV Beam - ATM,AXM, BTM & BXM, structure for 132 KV LA, 132 KV Isolator,132 KV C.T & Structure for 33 KV column & beam CCR, CGM, 33 KV Isolator, 33 KV C.T, 33 KV PT, 33 KV L.A.
19
-
-
GI flat earth strip 50x6 mm
1
-
-
MS round 40 mm for earth mat
2
-
-
Pipe electrode meter (treated pit)
2
-
-
Phase Plate (set of three)
20
-
-
Lighting Junction Box
1
-
-
Laying, stringing, tesioning, clamping, jointing, etc. complete with single/double ACSR panther/ moose conductor including hoisting of single/double tension fitting of insulator and all other assoceries on 132 KV Bay/Bus &/33 KV Bay/Bus.
15
-
-
Complete termination, interconnection, ferruling and dressing of control cable between equipment to equipment in outdoor switchyard and indoor control room all equipments
1
-
-
Providing & Laying of cable tray, cable glands, termination clamping, lugs fixing, cable marking, cable taging & ferruling etc. including providing of all material as required.
1
-
-
Work of complete testing of 145 KV Hybrid switch gear, LA & 36 kV CB, CT, LA etc as per manufacturer manual & IS including all connected erquipments before to energize work also includes submitting the test results copy (jointly signed) to the department in 03 copies .
1
-
-
Civil Works
-
-
-
Work of preparation of civil foundation drawing for 132/33KV power transformer, all 132 KV equipments & column for HV bay of transformer (LA, CT, Isolator and Circuit Breaker etc.), 33 KV equipments & column for LV Bay of transformer (LA, CT, Isolator, Circuit Breaker, Trench, Trench Cover etc), gantry with anchor bolts and new store shed as per the requirements of sites and type of soil.
1
-
-
Preparation of Electrical layout plan/earth - mat/ section elevations drawing.
1
-
-
Preparation of Cable Schedule/Inter-Panel Wiring Drawing.
1
-
-
Earth work excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or pits of any size, including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed, including all leads & lifts.
450
-
-
Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering. All work up to plinth level 1:2:4 (1 Cement, 2 Coarse sand, 4 graded stone aggregate 20 mm nominal size.)
42
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work up to plinth level 1:4:8 (1 Cement, 4 Coarse sand, 8 graded stone aggregate 40 mm nominal size.)
30
-
-
Providing and laying in position specified grade of reinforced cement concrete, including the cost of centering and shuttering, finishing. All work up to plinth level 1:1.5:3 (1 Cement, 1.5 Coarse sand, 3 graded stone aggregate 20 mm nominal size.) & also fixing of rail on transformer foundation.
215
-
-
First class brick work in 1:4 cement and sand mortar including cost of material, labour and T&P required for proper completion of work.
10
-
-
Plaster in 1:4 ratio with cement and sand including cost of material, labour and T&P required for proper completion of work.
100
-
-
Iron steel bar of different size in plain such as reinforced necessary including bending for proper completion of work and including supply of steel and authorized over lapping shall be measured.Work includes cost of material, labour, T&P etc.
17
-
-
Construction of trench (1.0x0.80x0.80 mtr.)/ (1.10x1.0x1.0 mtr) or desired size as per instruction of site incharge with trench cover complete including excavation work, C.C. work in 1:4:8 ratio & C.C. work in 1:2:4 ratio, first class brick work, plaster and fixing of (40x40 mm size) angle on top side of trench, fixing of angle size 40x40x5mm in interval of 0.5 mtr for laying of proper size of cable tray & Making frame of trench cover of required size by 40x40 mm size angle & Construction of trench cover by Cement concrete in 1:2:4 ratio as per site requirement.
60
-
-
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 4 mm dia wire, nuts bolts and washers as required complete as per the direction of Engineer-in charge 16.70.1 Made of G.I. wire of dia 4 mm
115
-
-
Fixing of gate, including cost of oxidised M.S. pressed butt hinges, Sliding door bolts, bolt black finish, door latches, handles with necessary bolts, screws etc.
2
-
-
Fabrication & fixing of MS/GI angle (provided by PTCUL) for making support by cutting, welding, bending, straightning, drilling and painting with one coat of red oxide and two coat of best quality enamel paint (desired color) after rubbing, cleaning of angles with embrey paper after fabrication.
40
-
-
Providing & fixing MS Flat (size 75x6 and 50x6 mm) alongwith all fastening items nut bolts washers as supporting structure for chain link fencing including all modification work such as welding, cutting, fabrication & painting with one coat of red oxide and two coat of best quality enamel paint (desired color) after rubbing, cleaning of angles with embrey paper after fabrication, work as per instruction of site incharge.
1
-
-
Work of providing & laying stones gravels size 40 mm.
150
-
-
Work of dismantling of old/existing pale fencing. Work including dismantling iron angle, and shifting material to store as per direction of site incharge.
1
-
-