Pey Jal Nigam Uttarakhand Tender
View complete overview of Uttarakhand Pey Jal Nigam Uttarakhand Tender
Pey Jal Nigam Uttarakhand Tender
Civil And Construction
Building Construction
Eprocure
Opening Date10 Oct 2024
Closing Date28 Oct 2024
Tender Amount₹ 32,01,000
Costs
EMD
₹ 64,000Document Cost
₹ 2,360Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MDPEY_76889_1Bid Award Id
ViewTender No
01/CAMP HALDWANI/ DT. 10/10/2024Tender Authority
Pey Jal Nigam Uttarakhand ViewPurchaser Address
-Website
http://http://peyjal.uk.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and filling in plinth with Jamuna sand under floors including, watering, ramming consolidating and dressing complete.
8.6
-
-
Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level withCement mortar 1:6 (1 cement : 6 coarse sand)
4.33
-
-
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 ( 1 cement : 6 coarse sand )
4.98
-
-
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shape and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
41.68
-
-
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
19.23
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
57
-
-
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars.
9275.29
-
-
Centring and shuttering including strutting,ropping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete.
35.4
-
-
Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform.
225.38
-
-
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
93.85
-
-
Centring and shuttering including strutting,ropping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts.
132.3
-
-
Providing and fixing pressed steel door frames confirming to IS: 43 from commercial mild steel sheet of 1.25 mm thickness including h jamb, bead and if required angle threshold of mild steel angle of se or base ties of 1.25mm pressed mild steel welded or rigidly fixed t mechanical means, adjustable lugs with split end tail to each jamb butt hinges 2.5mm thick with mortar guards, lock strike-plate and as specified and applying a coat of approved steel primer after pre surface as directed by Engineer-in-charge. Profile B
34.8
-
-
Steel work welded in built up section/framed work including cuttin in position and applying a priming coat of approved steel primer us required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
219.6
-
-
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with L-Type section made of 1.60m M.S. Sheet, joints mitred and welded and grinded finish profi required size with 15x3mm lugs 10cm long embedded in ce concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse graded stone aggregate 20mm nominal size) or with wooden plugs screws or rawl plugs and screws or with fixing clips or with b nuts as required including fixing of necessary butt hinges and and applying a priming coat of approved steel primers.
495
-
-
12 mm cement plaster of mix in 1:6 (1 cement : 6 fine sand)
251.6
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix :
300.06
-
-
6 mm cement plaster of mix. 1:3 (1 cement: 3 fine sand)
221.52
-
-
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
75
-
-
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick
223.2
-
-
Making plinth protection 50mm thick of cement concrete 1:3: cement :3 coarse sand : 6graded stone aggregate 20mm no size) over 75mm bed by dry brick ballast 40mm nominal siz rammed and consolidated and grouted with fine sand includin finishing the top smooth.
19.29
-
-
Providing and fixing ISI marked flush door shutters conforming to I non-decorative type, core of block board construction with frame o wood and well matched commercial 3 ply veneering with vertical g bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
10.08
-
-
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic) 300x16 mm
4
-
-
Providing and fixing aluminium handles ISI marked anodised (anodic coating not) 125 mm
8
-
-
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating ) 250x10 mm
8
-
-
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper
4
-
-
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured
93.18
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
275.8
-
-
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade
300.06
-
-
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications. Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm.
255.39
-
-
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
24.19
-
-
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture
35.52
-
-
Renewing glass panes, with putty and nails wherever necessary. Float glass panes of thickness 4 mm
19.8
-
-
windows using galvanised M.S. wire gauge with average width of a in both directions with wire of dia. 0.63 mm. With 12 mm mild steel U beading.
19.8
-
-
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 25 mm thick
186.28
-
-
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
12
-
-
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
9
-
-
Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203
1.8
-
-
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction
31.37
-
-
Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications)
9
-
-
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
12
-
-
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand (zone-III) : 10 graded stoneaggregate 40 mm nominal size).
1.44
-
-
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil
153
-
-
WGSTLPT Point wiring in PVC conduit, with modular type switch.Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group C
6
-
-
WGSTLMIDTC Twin Control point wiring in PVC conduit, with modular type switch: Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
2
-
-
WGSTLPP2 Power plug wiring in PVC conduit (2x4 sq. mm Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
25
-
-
WGSTLSB Circuit/ submain wiring in PVC conduit: Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2X2.5sqm+1x2.5sqmm earth wire
25
-
-
PVCCON S/F PVC conduit: Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including painting in case of surface conduit, or cuttting the wall and making good the same in case of recessed conduit as required. 25mm
10
-
-
MB S/F metal boxes: Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75 mm X 75 mm X 60 mm deep
2
-
-
PTSWEB S/F modular type switch/ socket:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
2
-
-
PTSWEB S/F modular type switch/ socket:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
1
-
-
MODFREB S/F modular type electronic fan regulator: Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
2
-
-
LPACCPT S/F light plug point modular type accessories: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
2
-
-
PPACCPT S/F power plug point modular type accessories: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
2
-
-
CREB S/F ceilling rose: Supplying and fixing 3 pin, 5 amp. ceilling rose on the existing junction box/ wooden block including connection etc. as required
2
-
-
BRHOLD S/F brass holder: Supplying and flxing brass batten/angle holder including connection etc. as required.
2
-
-
SUPPLY OF LED Glass Bulb B22, 12 W ,6000k /4000k/3000K ,230/250 Volt,50 HZ ETC, complete in all aspects as per direction of Engineer in Charge.
2
-
-
Supply and fixing of T5 LEDTube Light -Wall mounted LED batten , extruded aluminium Heat sink provided for efficient heat dissipation & integrated electronic driver. (1X22W LED )complete in all aspects as per direction of Engineer in Charge
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements