Pey Jal Nigam Uttarakhand Tender
View complete overview of Uttarakhand Pey Jal Nigam Uttarakhand Tender
Pey Jal Nigam Uttarakhand Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Dec 2024
Closing Soon26 Dec 2024
Tender Amount₹ 1,79,19,000
Costs
EMD
₹ 3,58,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MDPEY_78688_1Tender No
4931/Nivida(Garh)Elect.DDun/37 Dt.11/12/24Tender Authority
Pey Jal Nigam Uttarakhand ViewPurchaser Address
-Website
http://http://peyjal.uk.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
DSR 1.14.2
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2000
-
-
... More
DSR 1.14.3
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1500
-
-
... More
DSR 5.4
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
15
-
-
... More
DSR 5.9
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
300
-
-
... More
DSR 2.4
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
... More
DSR 2.4.1
4 way (4 + 12), Double door
4
-
-
... More
DSR 2.4.2
6 way (4 + 18), Double door
4
-
-
... More
DSR 2.4.3
8 way (4 + 24), Double door
4
-
-
... More
DSR 2.2
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
-
-
-
... More
DSR 2.2.14
125 A,36KA,FPMCCB
2
-
-
... More
DSR 2.2.15
200 A,36KA,FPMCCB (160 to 200)
3
-
-
... More
DSR 2.5
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
-
-
-
... More
DSR 2.5.2
8 way (4 + 24), Double door
3
-
-
... More
DSR 2.5.3
12 way (4 + 36), Double door
3
-
-
... More
DSR 2.10
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
DSR 2.10.1
Single pole
426
-
-
... More
DSR 2.10.5
Triple pole and neutral
12
-
-
... More
DSR 2.13
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
DSR 2.13.1
40 amp
2
-
-
... More
DSR 2.13.2
63 amp
9
-
-
... More
DSR 2.13.3
100 amp
2
-
-
... More
DSR 2.15
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required
-
-
-
... More
DSR 2.15.3
63 amp
12
-
-
... More
DSR 7.1
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
-
-
-
... More
DSR 7.1.1
Upto 35 sq. mm
3000
-
-
... More
DSR 7.1.4
Above 185 sq. mm and upto 400 sq. mm
600
-
-
... More
DSR 9.1
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
... More
DSR 9.1.29
3½ X 240 sq. mm (62mm)
20
-
-
... More
DSR 9.1.31
3½ X 400 sq. mm (82mm)
20
-
-
... More
DSR 14.15
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.
-
-
-
... More
DSR 14.15.5
200 mm dia (OD-200 mm & ID-175 mm nominal)
200
-
-
... More
DSR 1.32
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
50
-
-
... More
DSR 11.1
Erection of RCC/PCC pole of following length in brick ballast and ramming the foundation with 150 mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required
-
-
-
... More
DSR 11.1.2
Above 6.5 metre and upto 8.0 metre
50
-
-
... More
DSR 4.3
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
-
-
-
... More
DSR 4.3.1
100 mm width X 50 mm depth X 1.6 mm thickness
300
-
-
... More
DSR 4.3.2
150 mm width X 50 mm depth X 1.6 mm thickness
50
-
-
... More
DSR 4.3.6
450 mm width X 50 mm depth X 2.0 mm thickness
50
-
-
... More
Non Schedule
Supply of 3.5 c x 240 sq.mm aluminium armoured cable
300
-
-
... More
Non Schedule
Supply of 3.5 c x 400 sq.mm aluminium armoured cable
300
-
-
... More
Non Schedule
Supply of 4 c x 6 sq.mm aluminium armoured cable
3000
-
-
... More
Non Schedule
Supply ,Installation ,Testing , commissionig and aiming of high wattage LED Floodlight fixture having system wattage of 500W made of aluminium pressure die cast housing to ensure durability in harsh environment and excellant heat dissipation. The Luminaire should have optical cover/lens made of polycarbonate with beam angles ranging from 20° to 60°. The Lumiaire should comply with IK08 mechanical impact protection and IP66 for Ingress protection. The Lumiaire life shall be 50000 burning hours @ L70 criteria. The Luminiare shall deliver 60000 Lumens with a system efficacy of 120Lm/w. The Luminaire shall have CCT of 5700K and CRI not less than 90 i.e TLCI 90. the Drivers should be BIS certified with efficiency of 85%, THD 10% and P.F0.95. Surge Protection sholud be Upto 20Kv
103
-
-
... More
Non Schedule
Supply ,Installation ,Testing , commissionig and aiming of 1x4 Linear surface mounted LED Luminaire having system wattage of 36W made of CRCA Powder coated body. The Luminaire should have optical cover made of HETpolycarbonate.The Lumiaire should have IP20 for Ingress protection. The Lumiaire life shall be 50000 burning hours @ L70 criteria. The Luminiare shall deliver 3600 Lumens with a system efficacy of 100Lm/w. The Luminaire shall have CCT of 5700K and CRI not less than 80. the Drivers should be BIS certified with efficiency of 85%, THD 10% and P.F0.95. Surge Protection sholud be Upto 4Kv
36
-
-
... More
Non Schedule
Supply ,Installation ,Testing , commissionig and aiming of 2x2 Recess mounted LED Luminaire having system wattage of 36W made of CRCA Powder coated body. The Luminaire should have optical cover made of HETpolycarbonate.The Lumiaire should have IP20 for Ingress protection. The Lumiaire life shall be 50000 burning hours @ L70 criteria. The Luminiare shall deliver 4320 Lumens with a system efficacy of 120Lm/w. The Luminaire shall have CCT of 5700K and CRI not less than 80. the Drivers should be BIS certified with efficiency of 85%, THD 10% and P.F0.95. Surge Protection sholud be Upto 4Kv
300
-
-
... More
Non Schedule
Supply ,Installation ,Testing , commissionig and aiming of round surface mounted LED Luminaire having system wattage of 24W made of Pressure die cast Aluminium body. The Luminaire should have optical cover made of HETpolycarbonate.The Lumiaire should have IP20 for Ingress protection. The Lumiaire life shall be 50000 burning hours @ L70 criteria. The Luminiare shall deliver 2400 Lumens with a system efficacy of 100Lm/w. The Luminaire shall have CCT of 5700K and CRI not less than 80. the Drivers should be BIS certified with efficiency of 85%, THD 20% and P.F0.90. Surge Protection sholud be Upto 3Kv
180
-
-
... More
Non Schedule
Supply and fixing of street light 90 watt complete with pole painting and pole box repair/replacement etc
100
-
-
... More
Non Schedule
Supply and fixing of street light 45 watt complete with pole painting and pole box repair/replacement etc
100
-
-
... More
Non Schedule
Servicing/overhauling of fresh Air system including repair/replacement of spares, & comsumable, filter etc complete as per site requirement
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%