Pey Jal Nigam Uttarakhand Tender
View complete overview of Uttarakhand Pey Jal Nigam Uttarakhand Tender
Pey Jal Nigam Uttarakhand Tender
Eprocure
Opening Date26 Dec 2020
Closing Date11 Jan 2021
Tender AmountRefer Documents
Costs
EMD
₹ 57,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_MDPEY_28435_1Bid Award Id
ViewTender No
1591/NIVIDA/82 Dated 21/12/2020Tender Authority
Pey Jal Nigam Uttarakhand ViewPurchaser Address
-Website
http://http://peyjal.uk.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Concrete with 4 cm. Gauge approved stone ballast ,local sand and cement in proportion 8:4:1 in foundation and beam
6.69
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
22.07
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
6.98
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
29.87
-
-
Centring and shuttering for foundations, footings, bases of columns, etc. for mass sq.m concrete.
18
-
-
Centring and Shuttering for Suspended floors, roofs, landings, balconies and sq.m
access platform
157.54
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers
187.86
-
-
Columns, Pillars, Piers, Abutments, Posts and Struts.
89.86
-
-
Mild steel reinforcement including bending in R.C.C. work
6939.01
-
-
First class brick work in 1:6 cement & fine sand of 1.25 FM mortar in foundation & plinth including supply of all materials,labours,T&P complete.
9.83
-
-
40 mm thick damp proof course with cement and approved coarse sand 1:2:4 including water proofing material including supply of all materials, labour and T&P etc. required for proper completion of the work and including proper curing and shuttering as necessary.
15.47
-
-
First class brick work in 1:6 cement & fine sand of 1.25 FM mortar in super structure including supply of all materials, labours, T&P complete.
39.43
-
-
Supply and fixing of Z-section window and ventilators glazed complete in all respect
529.2
-
-
Steel work welded in built up section/ framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, kilogram gates and similar works.
86.52
-
-
30 mm thick flush door shutters(Sita ply or commercial quality door shutters)
8.4
-
-
Supply and fixing galvanized Mosquitos proof heavy quality iron wire gauge etc complete in all respect
15.12
-
-
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
15.12
-
-
6 mm thick plaster with cement & fine sand of 1.25 FM mortar in 1:4 for ceiling
158.31
-
-
15 mm cement plaster on rough side of single or half brick wall of mix 1: 6 (1 cement: 6 fine sand)
162.54
-
-
12 mm cement plaster of mix 1:6 (1 cement : 6 fine sand)
210.87
-
-
Concrete with 4 cm. gauge approved stone ballast, coarse sand, cement in proportion of 8:4:1 in floor including supply of all materials labour T&P etc. required for proper completion of works.
11.3
-
-
40mm thick cement concrete (1:2:4) flooring finished with a floating of neat cement.
113.03
-
-
Supplying and fixing of glass strips of 40x6mm size in cement concrete flooring.
339.1
-
-
20 mm thick skirting/Dado in 1:3 cement mortar with floating coat of neat cement
10.2
-
-
Distempering with oil bound washable distemper of approved brand and manufacture to give an required shade
158.31
-
-
One priming coat and three coat of oil bond distemper on new work, including supply of all material complete.
162.54
-
-
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors
using Primer as permanufacturers specifications Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of sq.m Special primer applied @0.75 ltr/10 sqm.
210.87
-
-
Painting two coat over one coat primer coat on wood work.
18.9
-
-
Painting two coat over one coat primer coat on iron work.
14.04
-
-
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured.
154.24
-
-
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
22.72
-
-
Excavation in Hilly Areas in Soil by mechanical means Excavation in soil in Hilly Area by mechanical means including cutting and cu.m trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1
300
-
-
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer - in - charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
24
-
-
Disposal of excavated earth upto a distance of 6 chain lengths
20.4
-
-
Filling of excavated earth in plinth including dressing,watering and ramming etc. complete.
3.6
-
-
PCC 1:4:8 under retaining wall
4.8
-
-
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc.(As per PWD Uttarakhand specifications)
57.6
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. Group C
15
-
-
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.
2
-
-
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed mediumclass PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.. (
150
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2X1.5 sq.mm. + 1X 1.5 sq.mm earth wire
100
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2x2.5 sq. mm + 1x2.5 sq.mm earth wire
50
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 6 sq. mm + 2 X 6 sq. mm earth wire for power DB
20
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4x10 sq. mm + 2x10 sq.mm earth wire
20
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm
75
-
-
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch
10
-
-
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 amp socket outlet
10
-
-
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
6
-
-
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
6
-
-
Supplying and fixing 3 pin, 5 amp. ceilling rose on the existing junction box/ wooden block including connection etc. as required
18
-
-
Supplying and flxing brass batten/angle holder including connection etc. as required.
15
-
-
Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling / wall, including connection with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
6
-
-
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 6 way (4 + 18), Double door
5
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
5
-
-
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissoning etc. as required. 40 amps
1
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1
-
-
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
10
-
-
Supply of AC 230/250 volts, 50 HZ fans including providing nuts, bolts, mounting frame and other accessories etc. completeModel- Ventil Air - DS (Make : Bajaj /Compton / Havells) 1200 mm sweep 900 rpm
4
-
-
SUPPLY OF LED Glass Bulb B22, 12 W ,6000k /4000k/3000K ,230/250 Volt,50 HZ ETC, complete in all aspects as per direction of Engineer in Charge.
15
-
-
Supply and fixing of T5 LEDTube Light -Wall mounted LED batten , extruded aluminium Heat sink provided for efficient heat dissipation & integrated electronic driver. (1X22W LED )complete in all aspects as per direction of Engineer in Charge
6
-
-
Supply,of following sizes of PVC sheathed LT XLPE armoured, aluminium 1.1KV grade, as required of the following sizes. 3.5c x 50 sq. mm cable
15
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements