Pey Jal Nigam Uttarakhand Tender
View complete overview of Uttarakhand Pey Jal Nigam Uttarakhand Tender
Pey Jal Nigam Uttarakhand Tender
Civil And Construction
Building Construction
Eprocure
Opening Date3 Dec 2024
Closing Date21 Dec 2024
Tender Amount₹ 7,20,35,000
Costs
EMD
₹ 14,40,000Document Cost
₹ 11,800Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MDPEY_78426_1Bid Award Id
ViewTender No
4733/Nivida(Garh) Khel D.Dun/191 Dt.30/11/2024Tender Authority
Pey Jal Nigam Uttarakhand ViewPurchaser Address
-Website
http://http://peyjal.uk.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
DSR Item- 12.50
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed
using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
6302.11
-
-
... More
NSI item-
Acoustical paneling on walls : Providing and fixing Acoustical Wall paneling with Compressed polyester fibre nonwoven 10mm thick panels with a density of 200kg/m3, of size1200mmX600mm with an NRC of 0.80 to 0.85 . The panels to be pasted with approved construction adhesives over 9mm thick perforated ply (minimum 20% perforations). The 9mm thick perforated ply shall be fixed over GI framing consisting of 48x36x34x0.5mm thick GI Studs wall channels & floor channels @ 600mm c/c with filling of 50mm thick 1000GSM thermally bonded polyester wadding. The insulation to be supported from the back by covering the frame with 19mm mesh GI wire netting. Approved Make : Acoustic India/ Absound Overseas/AMF.
1368.92
-
-
... More
DSR Item- 2.6.1
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
200.59
-
-
... More
DSR Item- 4.1.8
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
5.9
-
-
... More
DSR Item- 5.33.1.1
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level
48.36
-
-
... More
DSR Item- 5.22.6
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
5693.98
-
-
... More
DSR Item- 5.9
Centering and shuttering including strutting, propping etc. and removal of form for :
-
-
-
... More
DSR Item- 5.9.1
Foundations, footings, bases of columns, etc. for mass concrete
9.24
-
-
... More
DSR Item- 5.9.2
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
209.66
-
-
... More
DSR Item- 5.9.3
Suspended floors, roofs, landings, balconies and access platform
47.79
-
-
... More
DSR Item- 8.31
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
100.8
-
-
... More
DSR Item- 11.37
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc, complete.
40
-
-
... More
DSR Item- 22.23
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
-
-
-
... More
DSR Item- 22.23.1
For vertical surface two coats @ 0.70 kg per sqm
100.8
-
-
... More
DSR Item- 22.23.2
For horizontal surface one coat @1.10 kg per sqm.
40
-
-
... More
NSI Item-
Pump 2 hp
2
-
-
... More
NSI Item-
Supply installation testing and commissioning of 1.5 Ton 3 Star High wall Split AC (Hot and Cold) including initial charging etc. as reqqd.
20
-
-
... More
NSI Item-
Supply installation testing and commissioning of 2 Ton 3 Star High wall Split AC (Hot and Cold) including initial charging etc. as reqqd.
10
-
-
... More
NSI Item-
Supply installation testing and commissioning of 3 Ton 5 Star Ceiling Mounted Split AC (Cassette AC - Hot and Cold)including initial charging etc. as reqqd.
16
-
-
... More
DSR Item-6.6.1
Supply,Installation,Testing & Commissioning of modular type VariableRefrigerantFlow/ Variable Refrigerant Volume aircooled Outdoor units suitableforcooling andheating,having all hermetically sealed invertertype Scroll Compressor(s), minimum two compressors for above14HPmodules, microprocessor based Controller, top discharge type condensing unit(s) ,withR410A Refrigerant, vibration isolators, withsuitable foundationetc. complete asrequired. Theunitshalldeliver the rated capacity at AHR IConditionsandworkevenat 50°C ambienttemperature without tripping. The unit shall be suitable to workon 400V+/-10%, 3Phase, 50Hz AC powersupply.Theunit shall be filled with first charge of the refrigerant and ready for use as required.The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 . 16nos 20 HP each
-
-
-
... More
Supply,installation,testingandcommissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamicallybalancedblower, multispeedmotor, coilsection with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports,vibrationisolation, cordless remote control etc., suitable for operation on singlephase230V±10%,50Hz AC supply, complete,asrequired. The unit shall have automatic force shutdown provision in caseof fire on receiving signal fromBMSSystem. The cooling capacity of indoorunit will be at air inlet conditionsof27DegreeCDBand19Degree CWB temperature.
-
-
-
... More
1 TR 6 Nos
-
-
-
... More
1.6 TR 10 Nos
-
-
-
... More
4 TR 16 Nos
-
-
-
... More
Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noisefan/dynamically balanced blower, multispeed motor, coil section
with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
-
-
-
... More
High Static Ductable units (minimum 110 pascal external static pressure) 8TR 16 Nos
-
-
-
... More
Supply,Installation,testing and commissioning including vaccumiazation and Nitrogen testing of following nominalsizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings Y joints etc., with suitablea djustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines,allaccessories as per specifications etc. as required :
-
-
-
... More
6.4mmdia(OD)(Softdrawn)with tube thickness 1.2mm with19mmthick insulation 250 Mtr
-
-
-
... More
9.5mmdia(OD)(Softdrawn)with tube thickness 1.2mm with19mmthick insulation 200 Mtr
-
-
-
... More
12.7mmdia(OD)(Softdrawn)with tube thickness 1.2mm with19mmthick insulation 150 Mtr
-
-
-
... More
15.86 mmdia(OD)(Softdrawn)with tube thickness 1.2mm with19mmthick insulation 175 Mtr
-
-
-
... More
19mmdia(OD)(Hard drawn)with tube thickness 1.2mm with19mmthick insulation 200 Mtr
-
-
-
... More
22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19
mm thick insulation 150 Mtr
-
-
-
... More
25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19
mm thick insulation 200 Mtr
-
-
-
... More
28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19
mm thick insulation 175 Mtr
-
-
-
... More
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19
mm thick insulation 130 Mtr
-
-
-
... More
38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19
mm thick insulation 100 Mtr
-
-
-
... More
41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19
mm thick insulation 150 Mtr
320
-
-
... More
DSR Item-18.1.6
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in allrespects, as required (a) Horizontal type, multistage, centrifugal, split casingpump of cast iron body & bronze impeller with stainlesssteel shaft, mechanical seal conforming to IS 1520.(b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operationon 415 volts, 3 phase 50 Hz, AC supply with IP 55protection for enclosure, horizontal foot mounted typewith Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered.
2280 LPM at 56 mtrs Head
1
-
-
... More
DSR Item-18.2.6
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following,complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast ofiron body and bronze impeller with stainless steel shaft,mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thickaluminium sheet cladding, residential silencer,instruments and protection as per standard specification, stop solenoid for auto stop in the event offault with audio indications, painted with post office redcolour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plasteredand with anti vibration pads.2280 LPM at 56 mtrs Head
1
-
-
... More
DSR Item-18.3.3
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for
automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.180 LPM at 56 mts head
1
-
-
... More
DSR Item-18.5.2
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect,suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
INCOMING 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip ndicating lamps Set of Copper Bus Bar 300A OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps). Main Fire Pump
200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump 100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring
required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL
Control for diesel engine comprising -
Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter. All standard relays and accessories for automatic operation of diesel engine
System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per
specification
1
-
-
... More
DSR Item-18.6.2
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.150mm dia
75
-
-
... More
DSR Item-18.7
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including,Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the
wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthatic enamel paint of required shade complete as required :
-
-
-
... More
DSR Item-18.7.1 25 mm dia
97.5
-
-
... More
DSR Item-18.7.6
80 mm dia
48.75
-
-
... More
DSR Item-18.7.7
100 mm dia
25
-
-
... More
DSR Item-18.7.9
200 mm dia (wall thickness 6.3 mm)
32.5
-
-
... More
DSR Item-18.9.2
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel
25
-
-
... More
DSR Item-18.11
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gasketsconforming to IS 13095 of following sizes as required :
-
-
-
... More
DSR Item-18.11.4
80mm
13
-
-
... More
DSR Item-18.11.5
100mm
12
-
-
... More
DSR Item-18.12.6
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required.150mm dia
1
-
-
... More
DSR Item-18.13
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
25
-
-
... More
DSR Item-18.14.7
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required. 150mm dai
3
-
-
... More
DSR Item-18.15.4
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.200mm
1
-
-
... More
DSR Item-18.16.2
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required.Stainless Steel (Grade 304)
50
-
-
... More
DSR Item-18.17.1
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 mtrs
25
-
-
... More
DSR Item-18.18.2
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required. Stainless Steel (Grade 304)
25
-
-
... More
DSR Item-18.19.1
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required.2 way-100 mm dia M.S. Pipe
2
-
-
... More
DSR Item-18.20
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade
as required.
1
-
-
... More
NSI Item-
Supply of Aluminium Armoured Power Cables
-
-
-
... More
NSI Item-
4C 16 sqmm. Al Cable
25
-
-
... More
NSI Item-
3.5C 70 sqmm. Al Cable
50
-
-
... More
NSI Item-
3.5C 120sqmm. Al Cable
110
-
-
... More
NSI Item-
160MM PVC Sleeve
90
-
-
... More
DSR Item-9.1
Supply and making end termination with brass compresion gland and aluminium lugs for following size of PVC insulated and PVC sheated/XLPE aluminium conductor cable of 1.1KV grade as required.
-
-
-
... More
DSR Item-9.1.33
4C X 16 sqmm
2
-
-
... More
DSR Item-9.1.23
3.5C X 70 sqmm
2
-
-
... More
DSR Item-9.1.25
3.5C X 120 sqmm
2
-
-
... More
DSR Item-7.8
Laying & fixing of one no PVC insulated and PVC insulated and PVC sheated/XLPE power cable of 1.1 KV grade of following size on cable tray
-
-
-
... More
DSR Item-7.8.1
Upto 35 sqmm
25
-
-
... More
DSR Item-7.8.2
above 35 sqmm Upto 95 sqmm
50
-
-
... More
DSR Item-7.8.3
above 95 sqmm Upto 185 sqmm
20
-
-
... More
DSR Item-7.5.3
Laying & fixing of one no PVC insulated and PVC insulated and PVC sheated/XLPE power cable of 1.1 KV grade of folloing size in existing RCC/hume/Metal pipe as required. above 95 sqmm Upto 185 sqmm
90
-
-
... More
DSR Item-4.6
Supplying and installing following size of perforated Hot Dip galvanised Iron cable trays(Galvanization thickness not les than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I.suspenders including G.I. bolts & nuts etc reauired
-
-
-
... More
DSR Item-4.6.2
150 mm width X 50 mm depth X 1.6 mm thickness
20
-
-
... More
DSR Item-4.6.4
300 mm width X 50 mm depth X 1.6 mm thickness
30
-
-
... More
DSR Item-5.9
Supplying and Laying 25mm x 5 mm GI strip at 0.5 meter below ground as strip earth electrode, including connection / termination with GI nut, bolt, spring, washer etc as required.( Jointing shall be done by overlaping and with 2 sets of GI nut bolt & spring washer spaced at 50mm)
40
-
-
... More
DSR Item-5.1
Earthing with GI earth pipe 4.5 m long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.( but without charcoal /coke and salt) as required
2
-
-
... More
NSI item-
Providing and fixing carbon-di-oxide fire extinguishers trolley mounted with all accessories internal discharge tube,high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 Finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.
Capacity 22.5 Kg.
3
-
-
... More
NSI item-
Providing and fixing Carbon-di-oxide Fire Extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube. 30cms long high pressure discharge hose. Discharge nozzle,suspension bracket, confirming to IS:934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. (CCOE Nagpur Approved clynders). Capacity 4.5 Kg.
15
-
-
... More
NSI item-
Providing and fixing of ABC type (Stored Pressure) Fire Extinguisher I.S.I marked & T.A.C.approved complete in all respect.4 kg. capacity
36
-
-
... More
NSI item-
Providing & fixing carbon steel Fire man axe with rubber insulated handle tested to 20000 volts.
25
-
-
... More
NSI item-
Supply & fixing of main panel with 1 no. incomer of 400 amp.TP+ MCCB, Thermal Magnetic (O/C, S/C) Release 1 No. (L&T), Digital Amp. Meter 1 No., Digital Volt Meter 1 No., Metering CT-400/5A, CL-1.0 3 Nos, LED Phase Indication Light RYB 230V AC (Set) 3 Nos., Control Fuse 6A 3 Nos., Neutral Link 2 Nos, Wiring, PL 400A, FP, 415V Aluminium Busbar Link for MCCB with SMC/DMC Busbar supports and heat Shrinkable PVC Sleeve 1 No., Outgoings MCCB 32A TP+N, Thermal Magnetic (O/S,S/C) release with ROHM 24 Nos. (L&T), 3 Phase wiring with Power Terminals etc. 24 Nos complete in all respect.
1
-
-
... More
NSI item-
Supply and fixing of following sizes of PVC sheathed LT XLPE armoured, aluminium 1.1KV grade, as required of the following sizes. 3.5 c x 150 sq.mm
173
-
-
... More
Registration Fees, For independent feeder terminal equipment at sending end including swithch gear, ht cables, ct pt, meter cubicle etc, Terminal equipment at consumer end including HT cables, CT PT , meter cubicle etc., Over Head Line Cost, Security Deposit for Rs. 1000/KW
1
-
-
... More
Lighting protection
-
-
-
... More
DSR Item-6.2 Providing & fixing of lighting conductor final, made of 25mm dia 300 mm long GI tube having single prong at top, with 85 mm dia 6 mm thick GI base plate including holes etc. complete as required
357.5
-
-
... More
DSR Item-6.4 Jointing copper / GI tape,(with another copper/GI tape, base of the final or any other metallic object) by revetting/ nut bolting/sweating and soldering etc as reqd.
357.5
-
-
... More
DSR Item-6.7 Providing & fixing GI Tape 20mmX3mm thick on parapet or surface of wall for lighting conductor complete as reqd. (For horizontal run)
3750
-
-
... More
DSR Item-6.8 Providing & fixing GI Tape 20mmX3mm thick on parapet or surface of wall for lighting conductor complete as reqd.(Forvertical run)
1650
-
-
... More
DSR Item-6.12 Providing & fixing testing joint, made of 20mm X3mm thick GI strip 125 mm long with nos. of GI bolts nuts chuck nuts and spring washer etc complete as reqd.
75
-
-
... More
DSR Item-6.14 Providing & fixing GI Tape 20mmX6mm thick from earth electrode directly in ground complete as reqd.
1095
-
-
... More
DSR Item-5.2 Earthing with GI earth pipe 4.5 m long 40 mm dia. Including accessories and providing masonary enclosure with cover plate having locking arrangements and waterin pipe etc. with charcoal/ coke and salt as reqd.
75
-
-
... More
SITC of C.S.S
DSR Item-2023 plint area rate 6.2.1 Supply, Installation, testing and commissioning of (C.S.S) 33 Kv/0.33 Kv or 11 kv/0.433 substation equipment comprising HT panel, transformer, HT cable, bus trunking from transformer to LT panel, LT panel, automatic power factor correction panel, active harmonic filters, TVSS(transient voltage suppression system), SPD, essential panel, earthing required inter-connections substation safety equipments including LT cabling from substation to the building fed by the substation
630
-
-
... More
DSR Item-2023 plint area rate 6.2.1 Supply, Installation, testing and commissioning of (C.S.S) 33 Kv/0.33 Kv or 11 kv/0.433 substation equipment comprising HT panel, transformer, HT cable, bus trunking from transformer to LT panel, LT panel, automatic power factor correction panel, active harmonic filters, TVSS(transient voltage suppression system), SPD, essential panel, earthing required inter-connections substation safety equipments including LT cabling from substation to the building fed by the substation
1000
-
-
... More
DSR Item-7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
-
-
-
... More
DSR Item-7.1.1 Upto 35 sq. mm
478
-
-
... More
DSR Item-7.1.2Above 35 sq. mm and upto 95 sq. mm
158
-
-
... More
DSR Item-7.1.3 Above 95 sq. mm and upto 185 sq. mm
85
-
-
... More
DSR Item-7.1.4 Above 185 sq. mm and upto 400 sq. mm
1100
-
-
... More
DSR Item-10.2 Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11
KV grade as required :
-
-
-
... More
DSR Item-10.2.4 300 sq. mm
6
-
-
... More
DSR Item-9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV
grade as required.
-
-
-
... More
DSR Item-9.1.31 3½ X 400 sq. mm (82mm)
8
-
-
... More
DSR Item-5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
10
-
-
... More
DSR Item-5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe
of 2.7 metre long etc. with charcoal/ coke and salt as required.
16
-
-
... More
DSR Item-9.4 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for
following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
... More
DSR Item-9.4.18 3½ X 35 sq. mm
10
-
-
... More
DSR Item-9.4.28 3½ X 400 sq. mm
6
-
-
... More
DSR Item-10.5 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium
conductor cable of 11 KV grade as required :
-
-
-
... More
DSR Item-10.5.3 240 sq. mm
6
-
-
... More
DSR Item-5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.
(Jointing shall be done by overlapping and with 2 sets of G.I. nut
bolt & spring washer spaced at 50mm)
200
-
-
... More
DSR Item-5.8 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
170
-
-
... More
NSI item-Supply, Installatin, testing & commissioning of L.T Panel made of CRCA sheet steel dust and vermin proof with incommer 630 with change over switch & outgoing 250 FPMCCB 02 nos, 100 FPMCCB 02 nos complete with all respect
1
-
-
... More
NSI item-Supply of 3.5 c x 400 sq.mm L.T aluminium armoured cable
800
-
-
... More
NSI item-Supply of 3.5 c x 35 sq.mm L.T aluminium armoured cable
479
-
-
... More
NSI item-Supply of 3.5 c x 70 sq.mm L.T aluminium armoured cable
68
-
-
... More
NSI item-Supply of 3.5 c x 95 sq.mm L.T aluminium armoured cable
90
-
-
... More
NSI item-Supply of 3.5 c x 120 sq.mm L.T aluminium armoured cable
85
-
-
... More
NSI item-Supply of 3 c x 240 sq.mm H.T aluminium armoured cable
100
-
-
... More
NSI item-Fancing for L.T Panel Room
2
-
-
... More
NSI item- Making Foundation for above 2 nos C.S.S with all material
2
-
-