Pey Jal Nigam Uttarakhand Tender

View complete overview of Uttarakhand Pey Jal Nigam Uttarakhand Tender

Pey Jal Nigam Uttarakhand Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date11 Mar 2024
Closing Date22 Apr 2024
Tender Amount₹ 35,15,44,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Extra for planking, strutting and packing materials for cavities (in close timbering) if required to be left permanently in position. (Face area of timber permanently left to be measured).

1273.84

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).

120.34

-

-

... More
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works upto plinth level

1261.84

-

-

... More
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. All works above plinth level upto floor V level

1982.01

-

-

... More
Providing and laying in position machine batched, machine mixed cu.m and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement. including Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. M-25 grade reinforced cement concrete by using 410kg. of cement per cum of concrete. All work up to floor V level.:

1.8

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)

22.24

-

-

... More
Extra for providing richer mixes at all floor levels. Providing M-30 grade concrete instead of M-25 grade BMC/ RMC.

3243.85

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.

6130.38

-

-

... More
Centring and shuttering including strutting, ropping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete.

106.78

-

-

... More
Centring and shuttering including strutting, ropping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts.

8122.07

-

-

... More
Centring and shuttering including strutting, ropping etc. and removal of form for Lintel, beams, plinth beams, girder, bressumer and cantilevers.

6006.01

-

-

... More
Centring and shuttering including strutting, ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick

5958

-

-

... More
Centring and shuttering including strutting, ropping etc. and removal of form for Walls (any thickness) including pilasters,butteresses, plinth and string courses etc.

65.28

-

-

... More
Centring and Shuttering for Suspended floors, roofs, landings, balconies and access platform.

51.52

-

-

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75mm deep chase

23.54

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.

20

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 110 mm diameter

588

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler 110 mm

120

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5 degree 110 mm bend

4

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe

4

-

-

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including

12

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

3036

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)

69.2

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)

1455.2

-

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)

142.2

-

-

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

142.2

-

-

... More
Providing and fixing of ISI marked Partially insulated fire rated door single / double leaf GI Sheet doors conforming to FD 120-PI classification of IS 3614 :2021 with fire rating of 120 minutes integrity and 30 minutes insulation.The factory manufactured door frame and shutter assembly shall be finished with powder coating in standard RAL shade finish having DFT of minimum 30 microns. The door should carry a minimum 500 Hrs of salt spray test. All accessories like hardware, vision panel, fire & smoke seal etc. to be supplied by Fire door manufacturer only as per the guidelines laid down in IS 3614:2021.Every door must carry a label confirming to type of door & its fire rating. The test evidence from CBRI-Roorkee should not be older than 5 years. Due to ISI marking and guidelines of IS code there will not be any need of fresh testing within the above mentioned timeline. There should be a separate test evidence for both single leaf doors and double leaf door. The Door frame shall be single rebate grooved profile of size minimum 125mm x 75mm made out of 1.50mm minimum thick galvanized steel sheet. Frames shall be butt / mitered joint and field assembled with bolting system. Frames to have inbuilt groove to accommodate Intumescent fire seal strip of size 10x4mm. The frame should also be provided with EPDM seal to limit the spread of smoke vide clause no. 7.2.6 of IS code. All provisions should be mortised & provided with necessary inbuilt reinforcement to receive appropriate hardware. Frames should be provided with back plate bracket for anchor fastener with 8-10 mm dia and minimum 80 mm long HDG fasteners, with Polyamide sleeves (Payable in extra item) for installation of frame in finished plastered masonry wall opening. Note:- For grouting of Steel frames in masonry installations ;cement slurry of 1:3 ratio by civil contractor/fire rated PU foam or such fire rated material may be used except head member(Frame filling Payable in extra item). Door leaf should be minimum 60mm thick fully flush double skin door. Door leaf must be manufactured from minimum 1.2mm (18gauge) thick galvanized steel sheet. The infill material shall be mineral wool of minimum density 96 kg/cum. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For double leaf doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf. The shutters shall be mounted to the frame with SS 304 grade ball bearing type hinges of size 100x 75x3 mm alongwith all suitable hardware (Payable in extra item). Vision lite size 200x300 mm or (max area 0.06sqm) wherever applicable should be provided with single layered clear fire rated glass panes as per guidelines laid down under IS 3614 : 2021 vide clause no. 7.2.7 table no. 2 with a clipon arrangement.The glass will be provided with fire rated ceramic tape of min. 2 mm thickness alround on either face. Every Glass pane must carry a permanent marking of its glass manufacturer mentioning its details

112.08

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate

4049.08

-

-

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work

512.93

-

-

... More
Providing and laying flamed finish/leather finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

175.5

-

-

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

540.61

-

-

... More
Extra for pre finished nosing to treads of steps of Granite stone.

585

-

-

... More
Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre .

278.55

-

-

... More
Providing and fixing 18mm thick Granite stone work for wall lining at all height in cement mortar 1:3 (1cement : 3 coarse sand) including pointing with white cement mortor with an admixture of pigment to match the granite shade complete as per direction of Engineer-in-charge.

183.5

-

-

... More
Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : Decorative veneer facings of approved manufacture

123.32

-

-

... More
Supply and installation of Natural Creation ESSERTESS commercial heterogeneous vinyl flooring in planks. The total thickness would be 2.5 mm and the thickness of the wear layer would be 0.55mm. The product should be multi-layered consisting of a wear layer with PUR coating, PVC layer, fiberglass layer, and solid backing. Natural creation commercial shall conform to group T wear resistance as per EN 660-2, Flammability resistance of ≥0.45 as per ASTM E6848, Slip resistance of R8- R9 as per DIN1130, Residual indentation of ≤ 0.01mm as per ASTMF1914, Color fastness rating of ≥ 6 as per ASTM 105- B02. The product shall exhibit antistatic behavior, chemical resistance, and castor chair suitability. The floor should be smooth, flat, and free from moisture. Design and shade to be as per the architect’s choice, it should be installed by an authorized dealer in India.

3356.79

-

-

... More
Providing and fixing of Woven vinyl carpet floorings of series with roll dimensions of 1.8/2mtr meters width and length of 20 meters or Tiles size as per company standard should be approved by architech. 2.50-2.80 mm thickness to laid on hard, levelled, smooth and moisture free sub floor. Woven Vinyl flooring should have traffic classification 33 and weight of 2.7-3.5 kg/m2. Flooring should have caster chair EN-985 tested with color fastness of more than 6. It should be ASTME662 qualified on Smoke density test. Product must be fire rating of the product should be Bfl-S1. Any Joints in flooring rolls should be sealed with cold welding.As per approved shade and colour as per the satisfaction of the Architect.

179.36

-

-

... More
Water based bio-degradable epoxy polymide chemical on roof for water proofing treatment Supplying and applying of water based bio-degradable epoxy polymide chemical on roof for water proofing treatment in three layers over 20mm thick cement plaster laid in 1:3 cement and coarse sand mortar including all labour, material, T&P etc.The rate also includes addition of synthetic polyster triangular fibre of length 6mm, by using 125 gms of synthetic polyster triangular fibre per 50 kg cement used as per directions of engineer in charge.

58.4

-

-

... More
12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)

10019.23

-

-

... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)

6447.86

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 fine sand)

3648.47

-

-

... More
12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 (1 cement : 3 fine sand)

100.95

-

-

... More
Providing & fixing Chicken wire mesh on joints of RCC & Brick work before plastering complete in the direction of Engineer-in-charge.

13667.73

-

-

... More
Colour washing such as green, blue or buff to give an even shade : New work (two or more coats) with a base coat of white washing with lime

453.21

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

20115.59

-

-

... More
Finishing walls with Premium Acrylic Smooth Exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 over and including base

35.19

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

1170.42

-

-

... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two Coat

18491.96

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

8449.58

-

-

... More
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).

27438.03

-

-

... More
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml

2743.78

-

-

... More
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU panels in the curtain glazing is included in cost of item No.26.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.

2743.78

-

-

... More
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.

105.62

-

-

... More
Providing and fixing of Extruded Hollow Clay / Terracotta Ventilated Rainscreen Façade Tiles of grid dimensions 300 x 600mm/1200mm (c/c) in a horizontal direction on the building facade. The extruded hollow clay tile cladding material shall be rigid and of adequate strength and shall have a minimum total thickness of 16 mm (±10%). The tiles shall be installed using the ventilated rainscreen principle, with provision for natural ventilation of the space between the façade tiles and the structural wall. The clay tiles shall be of the hollow type, fixed to a supporting aluminium framework consisting of vertical 'T'/ 'L'/ Tube sections measuring 80x60x2mm/ 40x60x2mm/ 40x40x2mm respectively, spaced at maximum 600mm/1200mm c/c intervals matching to the tile vertical grid, and horizontal aluminium 'C'-clamps measuring 56x25mm x 150mm/ 75mm length fixed on top of the vertical sections at maximum 300mm c/c matching to the tile horizontal grid. The vertical 'T'/'L/Tube' sections shall be fixed to the wall using Steel L-brackets (Galvanized thickness minimum 80 microns) and Hilti/Wurth/ Fischer AISI 304 stainless steel anchor fasteners for MS framework/ brickwork/ concrete as applicable, spacing to be based on a structural/ static calculation. The brackets shall be fixed to the vertical aluminium T / L / Tube profiles using two AISI 304 stainless-steel self-drilling/ self-tapping screws of dimensions 5.5 x 25mm. The horizontal aluminium 'C'-clamps shall be fixed on top of the vertical aluminium 'T'/'L/Tube' sections from front using two AISI 304 stainless steel self-drilling/ self-tapping screws. The tiles shall be mounted on the C-clamps such that the tiles are supported at top and bottom at both ends. The tiles shall be additionally secured to the horizontal C-clamps using special stainless steel clips which shall be inserted and pressed into position on the C-clamps holding the tiles. In certain cases, instead of securing the tiles with clips, the tiles shall be glued at points to the horizontal C-clamps using an MS Polymer Sealent adhesive. The vertical joint between adjacent tiles to be a 6mm open groove.MAKE: ANAKON/EKOS/HUNTER DOUGLAS/MOEDING

1049.97

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 1000x1000 mm

866.82

-

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 1000x1000 mm

186.44

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm

669.02

-

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm

1581.47

-

-

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.

171.99

-

-

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick

103.53

-

-

... More
6mm thick annealed Planilaque Evolution or equivalent (Premium Griha rated Lacquered Glass) manufactured industrially by curtain coating process with PU lacquer(50 micron thick), opaque (if viewed against a support wall) confirming to EN 16477 standards for back painted glass , of approved colour by Architect / Client fixed with compatible glassmate Ultrafix or equivalent. Neutral Alkoxy based Silicon having shear bond strength (Dry, 24 hours), greater than 450 kpa and tack free time of 10 to 30 minutes compatible for installation of mirror and lacquered glass / Glassmate Mirror mounting tape MIRROR MOUNTING TAPE or equivalent -Foam based double sided adhesive tape for instanteneous adhesion, compatible with mirror and lacquered glass having shear bond strength (Dry, 15 mins) of 250 to 350 kpa ) on a perfectly leveled 12mm thick water proof marine plywood / MDF / Mineral Fibre board which is mounted on the RCC wall / any other. Properties: High humiditity resistance (confirming to BS 1036:1999); colour fastness ISO 105B02 standard and mechanical resistance ISO 7784 (Taber Abrasion Test) ISO 2409 (Cross Hatch Test) standard. The manufacturer back painted glass should be environmental friendly (no lead, no arsenic, no copper, no formaldehyde): appropriate recycled content (12% post industrial / 6% post consumer); compressive strength (1000 Mpa) & tensile strength (40 Mpa), same as float glass . a) Lacquered glass / back painted glass must be made industrially (via curtain coating process or equivalent ); opaque (if viewed against a supporting wall), coated with PU lacquer (min 25 micron thick); b) Colour consistency (measured by minolta spectrophotometer CM5081 or equivalent): c) Highly durable (passes PERSOZ hardness test for minimum 220 oscillations or equivalent); d) Humid resistance (confirms to BS EN 1036:1999 or equivalent ); environment friendly (no lead, no arsenic, no copper, no formaldehyde): e) Appropriate recycled content (12% post indtrial / 6% post consumer or as per standard) ; comprehensive strength (1000 Mpa)

123.32

-

-

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mmdia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks)

554.59

-

-

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece

390.63

-

-

... More
Providing & fixing Anavertical Linear Baffle Box Curtain Closed Ceiling made out of Aluminum Extrusion of 1.2mm thickness. The baffle blade shall be in size of 30 x 100 x 3000mm in powder coated finish of approved shade or wooden texture. The baffle blade shall be suspended using Slotted U-profile powder coated to black colour at an on-center spacing of 100/150/200mm. The C-Channel/U profile shall be suspended at every 1200mm on-centre using 6mm threaded rod/4mm rod/12 gauge hanger wire from the structural soffit at every 1200mm intervals using U-profile hanger/C-channel hanger. Multiple lengths of U-profile/C-channel shall be connected using U-profile connector/ C-channel connector. The baffle blades shall be suspended from the C-channel/U-profile carrier bars at the required intervals (100/150/200/250mm) using baffle hangers. Spacing between blades shall be adjusted using the slots in carrier.MAKE:ANAKON/ECOPHON/LINDER

3043.98

-

-

... More
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-incharge.With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6

114.14

-

-

... More
Providing and Fixing Soundscapes Poly fiber Acoustical Clouds which are 50mm thick, flat glass fiber panels with Humidity Resistance RH 90% and recycled content of minimum 40%, come in various shapes options like Square/ Convex/ Concave/ Circle/Hexagon/ Trapezoid/Parallelogram (left and right)/ Rectangle (small and large) and in standard traffic white color with LR 90% or in the color specified by the Architect/ Engineer in Charge (Ivory/Pale green/ Pastel Blue/ Traffic grey/ Pale Brown) provisions are already made for integration of installation system for suspension of individual or grouped panels. The panels to be suspended individually using the Deck hanging Kit. Each kit to consist of gripper structure anchors with an outer diameter of 16mm and height 23 mm aircraft cables or threaded wire of 1.5 mm dia 2.44mm LM in length and bottom end cable adjusters of 8.9mm outer diameter. Each Panel to be suspended using the aircraft cables or threaded wire which are suspended from the soffit using the gripper structure anchors and its other end passing through the bottom end cable adjuster which are screwed in the 4 corners of the frame bracket system. The height and level of the panels can be adjusted using the bottom end cable adjusters complete in all respects as per manufacturer specification and as per the direction of Engineer in charge.MAKE:ANAKON/ARKTURA/ACOUSTIC FIRST

227.27

-

-

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming tc IS 2645 in recommended proportions.(ii) 11 nd course of 20 mm cement plaster 1:3 (1 cement:3 coarse sand)mixed with water proofing compound in recommended proportion, (iii) Illrd course of applying blown or/residual bitumen aplied hot at 1.7 kg. per sqm of area, (iv) Ivth course of 400 micron thick PVC sheet.(Overlaps at joints of PVC shet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).

336.5

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade

13.49

-

-

... More
Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work.

30.21

-

-

... More
Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete.

30.21

-

-

... More
Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.

2

-

-

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Second class teak wood

1.29

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

69.15

-

-

... More
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) over item no. 9.20 and 9.21

69.12

-

-

... More
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick

138.24

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately).

56.64

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge

37.28

-

-

... More
Tower bolt Surface Mounted, L - 12" (300 mm), SS 304, SSS

62

-

-

... More
Lever Handle with 6501 Roses,6612 Escutcheons, 8mm Spindle with Fixing Screws for door thickness 35-55mm, SS 304, Finish : Satin with 271a Sash Lock Backset - 55mm, Centre to Centre - 72mm, 20mm Square Forend, Strike plate, SS 304, Finish : SSS and EPC 60mm BSK

58

-

-

... More
Door Stop half dome 45 mm dia

42

-

-

... More
Door Closer with Std Arm EN 2/3/4 Finish : Silver

38

-

-

... More
Providing and fixing approved brand and manufacture SS 304 grade Top & Bottom Patch fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.

56

-

-

... More
Providing and fixing approved brand and manufacture SS 304 grade D type 300mm Pull Handle with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.

28

-

-

... More
Providing & fixing of Toilet cubical( of Greenlam or equivalent of following standard dimension which includes 600mm door size width) of 1995 mm in total height and made up of thermosetting resign treated high pressure ,self supporting decorative compact laminates with permanently incorporate anti-bacterial agents during manufacturing .Compact board should be resistance to water immersion through permissible increase on thickness and mass 0.60% and board density 1.35kg/cm3 and fulfilled the criteria of green guard gold certification and manufactured under IS2046 and EN438-2&3:2005 standard. 12mm thick compact board should be Moisture resistant, Impact resistant, termite resistant ,Scratch resistant ,Weather and climatic shock resistant. Finish of compact laminates should be suede finish which includes door, pilasters and intermediate panels finished with approved texture/shades as per IS2046 and fulfilled the criteria of fire retardant under BS-476/97 and EN438-6 with classification of BS1D0 standard. Pilaster to be supported by grade -6 Nylon polyamide thermoplastic palm designpedestal footing with non corrosive steel inserts and intermediate panels will attached to the wall with the help of approved aluminum U channel and all required hardware, made up of Nylon polyamide Grade-6 &aluminum powder coated as per manufacturer’s specification like Door knob, gravity hinges, Thumb turn locksets with occupancy indicators ,coat hooks with door stoper , U channel, top rail with corner connector, adjustable foot/pedestal,Rubber noice deafening tape, screw & wall plugs should be approved under the instruction of Engineer-in-charge. The top fitting should consist of Aluminium powder coated or anodized(Grade 6063) top rail which will get fixed with Mid & End plister. . All screw will of 304 grade in SS finish. All pilasters are supported by Nylon polyamide footing with non corrosive steel inserts.The base diameter 65mm and neck diameter of 33mm anchored to the floor with 304 grade SS screws with pust fit capping at a clearance height of 150mm .Finish and colour of Toilet cubical should be approved under guidance of engineer-in-charge.

60

-

-

... More
Providing and Fixing of Akous wood grooved panel having system NRC up to 0.88 with lineal perforation. The high grade MDF/HDDMR panels shall be melamine laminate of size 2440mm x128mm x 18mm with 2mm groove at 14mm pitch, Tongue and Groove edges for seamless mounting having density of 800kg/m3(base panel confirming to IS 12406 and laminated panel confirming to IS 14587). The back of the panels are perforated with a nonwoven fabric covering of 0.2mm for providing Sound absorption via the acoustic impedance method. Panel is fixed by using GI Framework 2400mmx50mmx0.50mm spaced at 600mmx600 c/c & 12 mm WPC framework spaced at 400mm centers with suitable brackets and the system is backline with 50 mm Rockwool insulation@48kg density and along with all accessories example: chicken mesh and all. MAKE: DECOR SYSTEM/ANAKON/ECOPHON

1014.45

-

-

... More
Providing and Fixing of Spandex System on G.I studs 2400mm X 50mm web flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel With 120GSM zinc coating specially designed for Acoustic vibration management and long life with a backing 50mm thick Rock wool @48kg density insulation intact with chicken mess wires. 600x1200x15mm Magnetite pine wool tile with NRC 0.9-1 to be mechanically fastened on the G.I Studs. Then 12mm clip rail system are screw fixed on to the 12 mm MDF waterproof and Acoustics panel’s .Then the Spandex is stretched over the clip rail system. The installed system should provide NRC OF 1.00. Spandex colour as per Architect choice-Ref attached specifications for more details. The system to be installed on G.I studs 600x600mm centre to centre 2400mm X 50mm web thickness 0.5mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120GSM zinc coating specially designed for Acoustic vibration.

137.43

-

-

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a)Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.

870

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.

-

-

-

... More
15 mm nominal outer dia Pipes

315

-

-

... More
20 mm nominal outer dia Pipes

420

-

-

... More
25 mm nominal outer dia Pipes

175

-

-

... More
32 mm nominal outer dia Pipes

105

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall

-

-

-

... More
15 mm dia nominal bore

5

-

-

... More
20 mm dia nominal bore

20

-

-

... More
25 mm dia nominal bore

20

-

-

... More
32 mm dia. nominal bore

30

-

-

... More
40 mm dia. nominal bore

80

-

-

... More
50 mm dia. nominal bore

80

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 50 mm dia nominal bore

40

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
25 mm dia nominal bore

24

-

-

... More
32 mm dia. nominal bore

2

-

-

... More
40 mm dia. nominal bore

2

-

-

... More
50 mm dia. nominal bore

6

-

-

... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.

24

-

-

... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bor

42

-

-

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approvedquality .(15 mm nominal bore)

2

-

-

... More
Providing and fixing uplasticised PVC connection pipe with brass unions : 30 cm length 15 mm nominal bore

30

-

-

... More
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 50 mm nominal bore

4

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

15000

-

-

... More
Supplying, installing, testing and commissioning of SS vertical centrifugal pump. Each pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have cast iron head, base plate SS Shaft / Impeller / Intermediate chamber along with motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, stainer (with by-pass) at suction. Pump shall be provided with mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve (25 dia). The pump shall be suitable for auto/ manual operation. The installation shall be complete with all necessary ancillaries, starter panel / control panel & accessories including base plate complete as required. The entire Hydropneumatic system shall be factory fitted. Filter feed pump Flow rate : 100.0 LPM each Pumping Head - 35 m 1 Set = 2 Nos. pump (1 working+1 standby) Approx H.P. - 2.5 HP or as per manufacturer recommendation.

1

-

-

... More
Supply, installing, testing and commissioning of submersible open impeller non-clog pumps with C.I.body and to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, guide pipe and chain in built level controller, sequence running controller, arrangement for both pumps together inacase of emenegency, audible hooter for failure or flooding, dry running Protection complete in all respects., painting, testing and commissioning complete with approved quality and make as required as per instruction of site incharge. (Pumps shall be installed in a set of two pumps One working and One standby) Basement & Pump Room Drainage Pumps (Pumps to be suitable to handle solids upto 12 mm size) Capacity - 5.0 LPS (Each) Head - 40 M , H.P. - 5.0 HP Approx.

1

-

-

... More
Supply, installing, testing and commissioning of vertical Multigrade Sand Filter (comprising of minimum 300 mm depth of Anthracite, 200 mm depth of pebbles in two layers of 100 mm each, 100 mm depth of gravels,100 mm depth of coarse sand and 300 mm depth of filtering sand. Minimum Height of Straight 1500mm) fabricated from high performance M.S plate of minimum 8 mm thick for shell & 10 mm thick for dished ends,(Quality of Steel as per IS:2062 Grade B, thickness as per ASME Section 8),Tested to 5.0 Kg/cm2 , internally treated with coal-tar epoxy, air scouring, collection system initial charge of media, M.S face piping with necessary flanges, gaskets, isolating valves, accessories,nuts & bolts, external painting with 2 coats of zinc chromate primer and synthetic enamel paint etc. with suitable foundation boits & other accessories, mounting frame, complete with testing and commissioning etc.as required & as specified. Diameter : 750 mm (Approx.) Shell thickness : 8 mm. Dished ends : 10 mm HOS : 1200 mm (Approx.) Depth of filter media :900 mm Filteration capacity : 6 cu.m/hr Flow thru' rate : 15000 ltr./hr./m2, Filter Media : Silex Quartz, (Multigrade) and Anthracite, Material of Construction: MS-EP, Manhole size : 450/ 600 mm, Working Pressure : 3.5 Kg/Sq.cm.

1

-

-

... More
Supply, installing, testing and commissioning of vertical Activated Carbon Filter (comprising of minimum 450 mm depth of Activated Carbon, 200 mm depth of pebbles in two layers of 100 mm each, 100 mm depth of gravels,100 mm depth of coarse sand and 300 mm depth of filtering sand. Minimum Height of Straight 1500mm) fabricated from high performance M.S plate of minimum 8 mm thick for shell & 10 mm thick for dished ends, (Quality of Steel as per IS:2062 Grade B, thickness as per ASME Section 8),Tested to 5.0 Kg/m2 , internally treated with coal-tar epoxy, air scouring, collection system initial charge of media, M.S face piping with necessary flanges, gaskets, isolating valves, accessories,nuts & bolts, external painting with 2 coats of zinc chromate primer and synthetic enamel paint etc. with suitable foundation boits & other accessories, mounting frame, complete with testing and commissioning etc. as required & as specified with the following:, Diameter : 750 mm (Approx.), Shell thickness : 8 mm. Dished ends : 10 mm, HOS : 1200 mm (Approx.), Depth of filter media :900 mm, Filteration capacity : 6 cu.m/hr, Flow thru' rate : 15000 ltr./hr./m2, Filter Media : Silex Quartz, (Multigrade) and Anthracite, Material of Construction: MS-EP, Manhole size : 450/ 600 mm, Working Pressure : 3.5 Kg/Sq.cm.

1

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :

42

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar tap

24

-

-

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 225 mm

6

-

-

... More
Providing and fixing soil, waste and vent pipes : Sand cast iron S&S pipe as per IS: 1729 110 mm dia.

530

-

-

... More
Providing and fixing soil, waste and vent pipes : Sand cast iron S&S pipe as per IS: 1729 75 mm dia.

154

-

-

... More
Providing and fixing M.S holder-bat clamps of approved design to PVC/Sand Cast iron/ cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. for 110 mm dia pipe

179

-

-

... More
Providing and fixing M.S holder-bat clamps of approved design to PVC/Sand Cast iron/ cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. for 75 mm dia pipe

47

-

-

... More
Painting pvc/ sand cast iron / centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint off any colour such as chocolate, grey, or buff etc. over a coat of primer (of approved quality) for new work: 110 mm diameter pipe

530

-

-

... More
Painting pvc/ sand cast iron / centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint off any colour such as chocolate, grey, or buff etc. over a coat of primer (of approved quality) for new work: 75 mm diameter pipe

154

-

-

... More
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :

48

-

-

... More
BOTTLE TRAP, F8060301 228 mm (9”), Cera/Jaguar make

60

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 15mm nominal bore

30

-

-

... More
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia

24

-

-

... More
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.

2

-

-

... More
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.

12

-

-

... More
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.

36

-

-

... More
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.

12

-

-

... More
Providing and fixing terminal guard : 100 mm Sand cast iron S&S as per IS - 1729

4

-

-

... More
Sand cast iron S&S as per IS - 1729 : 75 mm Sand cast iron S&S as per IS - 1729

2

-

-

... More
Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :100x100x100x100 mm Sand cast iron S&S as per IS - 1729

14

-

-

... More
Providing and fixing plain bend of required degree Sand cast iron S&S as per IS - 1729 - 100mm dia

54

-

-

... More
Providing and fixing plain bend of required degree Sand cast iron S&S as per IS - 1729 - 75mm dia

12

-

-

... More
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100x100x100 mm Sand cast iron S&S as per IS - 1729

104

-

-

... More
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100x100x100 mm Sand cast iron S&S as per IS - 1729

12

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter

320

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single Push Fit Coupler 110 mm dia

107

-

-

... More
Plain bend 87.5 deg 110 mm dia

4

-

-

... More
Shoe (Plain) 110 mm dia

4

-

-

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

60

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe

60

-

-

... More
Providing and laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40 mm nominal size) all round S.W pipe including bed concrete as per standard design: 100 mm diameter S. W. pipe

60

-

-

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.

2

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

-

... More
Extra depth for manholes Size 90x80 cmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5

2

-

-

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in\ cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

4

-

-

... More
Sewage Treatment Plant 50 KLD ( MBBR Technology) Design, Supplying, installing, testing & commissioning of Sewage Treatment Plant of 50 KLD (excluding excavation, back filling & disposal of surplus earth MS / Civil construction work) for the following duty: Sewage treatment plant shall include the following items: a. Screen chambers with SS Screen, b. Equalization Tank, c. Anoxic tank, , d. MBBR TANK, e.Tube settler tank, f.Sludge holding tank g. Clear water tank, h.Treated water tank, i. UF Tank, j. Air Blowers, k. MBBR Media, deck media, l. Recirculation pumps, backpulse pump, permeate pump, valve, MS piping Exopsed & SS SCH 40 pipe submerged etc. m. Dewatering system, n. Electrical Panel, Cabling (Power & Control), Earthing, o. Tertiary Treatment, p.UF System INLET SEWAGE CHARACTERSTICS (ASSUMED), pH - 6.0 – 8.5, BOD5 : 250 - 350 mg/lit, Total Suspended Solids (TSS) : 250 - 450 mg/lit, COD : 500 - 700 mg/lit, Oil / Grease : upto 50 mg/lit, Inflow time : 24 HRS, Peak factor : 3, Temperature : Ambient, Desired Sewage Quality After Treatment, pH : 7 - 8, BOD5 : 10 mg/lit , Total Suspended Solids (TSS) : 10 mg/lit, COD : 50 mg/lit, Oil / Grease : 5 mg/lit, Colour : Colourless, Odor : unobjectionable, E.coli : Nil, NH4-N : 5 mg/lit, N Total : 10 mg/lit, PO4-P : 2 mg/lit. Note: 1- Vendor shall ensure submission of detailed Design & GA drawings (Plan & Section), P&I diagram, schematic diagram for the above said component and additional component if so required for the complete working of the STP for the full capacity.Note : All Civil 2- Works with Structural Walk Ways/ Railings, to be Done extra.

1

-

-

... More
ROAD WORK Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.

732

-

-

... More
Gravel/Soil-Aggregate Base (Table 400.2) Grading B Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with three wheel 80-100 kN static roller capacity to chieve the desired density, complete as per Technical Specification Clause 402

183

-

-

... More
WBM Grading 2 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405.

109.8

-

-

... More
WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. By Mechanical Means

109.8

-

-

... More
Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer incharge.

732

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment).

1004.5

-

-

... More
Trenching in ordinary soil up to a depth of 60cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling with in a lead of 50m and making up the trenched area to p

1004.5

-

-

... More
Renovating lawns including weeding, cheeling the grass, forking the ground, top dressing with sludge or manure, mixing the same with forked soil, watering and maintaining the lawn for 30 days or more till the grass forms a thick lawn free from weeds and f

4018

-

-

... More
Supplying & Stacking of Selection No.1 doob grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge.

4018

-

-

... More
Supplying and stacking sludge at site including royalty and carriage up to 1 km(sludge measured in stacks will be reduced by 8% for payment)

803.6

-

-

... More
Supplying and stacking at site dump manure from approved source, including carriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8% for payment) :

401.8

-

-

... More
Suply and plantation of mature trees including excavation of pit, providing manure and watering and caring for one year as per directions of Engineer-Incharge

60

-

-

... More
Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m high, above ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6 mm M.S. flat iron rings in two halves, fixing together a

60

-

-

... More
Fire Fighting Work Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520., Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325, M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required, Suitable cement concrete foundation duly plastered with anti vibration pads, 2280 lpm at 88 m Head (For Hydrant & Sprinkler System). Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.

2

-

-

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump), Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520., Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required., M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required., Suitable cement concrete foundation duly plastered with anti vibration pads, 2280 lpm at 88 m Head (For Hydrant & Sprinkler System)., Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/farthest point.

1

-

-

... More
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)., Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520., Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325., M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required, Suitable cement concrete foundation duly plastered and with anti vibration pads.180 lpm at 88 m Head (For Hydrant & Sprinkler System).

2

-

-

... More
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : Incomings, 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating, Digital Voltmeter 0-500V with selector switch, Ammeter (0-400 A) with selector swtich & CTs etc., LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps, Set of Copper Bus Bar 500A, Outgoings, ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps), Main Fire Pump ,200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 2 Set, Jockey Pump, 100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 2 Set, Diesel Engine Control, Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempt starting device, timers and relays as required, push buttons, start/stop in manual mode, Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication. Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter. All standard relays and accessories for automatic operation of diesel engine, System Controller : Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specifications.

1

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge.

-

-

-

... More
4 x 25 sqmm ( 28 mm )

4

-

-

... More
3.5 x 50 sqmm ( 35 mm )

4

-

-

... More
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. 150 mm width x 50mm depth x 1.6 mm thickness.

20

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

20

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

40

-

-

... More
Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of 1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/ masonary Open Duct/ cable tray/ open in air etc. as requred.

-

-

-

... More
4 core, 25 sq.mm. Aluminium Armoured

50

-

-

... More
3.5 core, 50 sq.mm. Aluminium Armoured

100

-

-

... More
Supply and fixing in position 1 m wide Insulation mat made of elastomeric polymers Material (Class -A) of 415V grade as per IS 15642-2006 . Thickness of insulation mat shall be not less than 2 mm to withstand 1.1 KV dielectric strength AS PER IS 15652 : 2006. It should be complete as per specifications & directions of Engineer-in-charge.

5

-

-

... More
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. ( For Underground )

-

-

-

... More
150 mm. Dia

50

-

-

... More
100 mm. Dia

20

-

-

... More
80 mm. Dia

10

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required. (Plant Room piping/Vertical Riser/Downcomer/Floor)

-

-

-

... More
25 mm dia

1200

-

-

... More
32 mm dia

150

-

-

... More
40 mm dia

200

-

-

... More
50 mm dia

100

-

-

... More
65 mm dia

100

-

-

... More
80 mm dia

125

-

-

... More
100 mm dia

100

-

-

... More
150 mm dia

120

-

-

... More
200 mm dia (wall thickness 6.3 mm)

10

-

-

... More
250 mm dia (wall thickness 6.3 mm)

10

-

-

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal

8

-

-

... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal

5

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :

-

-

-

... More
50mm dia

2

-

-

... More
80 mm dia

12

-

-

... More
150 mm dia

16

-

-

... More
200 mm dia

2

-

-

... More
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.

4

-

-

... More
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :

-

-

-

... More
80 mm dia

2

-

-

... More
150 mm dia

7

-

-

... More
200 mm dia

1

-

-

... More
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.

-

-

-

... More
150 mm dia

1

-

-

... More
200 mm dia

2

-

-

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal

26

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 36 m

8

-

-

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal

13

-

-

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :

-

-

-

... More
2 way-100 mm dia M.S. Pipe.

1

-

-

... More
4 way - 150 mm dia M.S. Pipe. (FOR UG TANK & EXTERNAL RING MAIN)

2

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.

1

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :

-

-

-

... More
Pendent Sprinkler

580

-

-

... More
Upright Sprinkler

620

-

-

... More
Horizontal side wall sprinkler

20

-

-

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.

5

-

-

... More
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 150mm dia

8

-

-

... More
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia

1

-

-

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.

-

-

-

... More
700 mm

232

-

-

... More
1000 mm

232

-

-

... More
1200 mm

58

-

-

... More
1500 mm

58

-

-

... More
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.

580

-

-

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required

30

-

-

... More
Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete.

8

-

-

... More
Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2 & 1 No. Dry podwer type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & "FIRE HOSE" written on front. (Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE )

8

-

-

... More
Providing and fixing hose cabinet of size 750mmX600X250mm made of 16 gause thick MS sheet with 4 mm thick float glass doors in front painted "FIRE" in red paint i/c recessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15 mtr. long hose pipe. 1 no. brach pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant. as directed by Engineer-in-Charge.

5

-

-

... More
Pressure Vessel Supplying, installing, testing and commissioning of pressure vessel for pressurization of fire system complete with valves at outlet / drain to operate as per operating sequences including 25 mm dia drain valve, air release valve with stop cock on the top, outside with one coat of primer & two coats of synthetic enamel paint of approved shade complete as required to operate commonly main fire pump, sprinkler pump & jockey pump at drop of pressure, automatically at required pressure setting. Complete as per manufacturer's specifications & as directed by Engineer- in-charge. working pressure:- 11 kg/sqcm test pressure: 20 kg/sqcm (450 mm dia & 2000 mm height)

2

-

-

... More
Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges.

-

-

-

... More
150 mm dia

6

-

-

... More
80 mm dia

4

-

-

... More
Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm.25 mm Dia

13

-

-

... More
Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass ,Reducer ,union, G.I PIPE. connection to drain pipe/riser.

8

-

-

... More
Providing & fixing cast iron 100 mm dia. Foot valve with nuts, bolts, 1.5 mm thick CAF gasket complete with all accessories (To be provided into UG Fire Water Tanks).

2

-

-

... More
Supply and fixing of 4 Nos G.I round bottom FIRE BUCKET of 9 LTR. Capacity field with sand including proper supporting /mounting arrangement MS Angle Iron Frame painted by fire red colour over 2 coats of red oxide paint and written with white paint FIRE complete in all respects as per direction of Engineer Incharge .

4

-

-

... More
Providing, fixing water flow meter on test line complete with all accessories for flow indication , monitoring & testing of fire pumps with bypass arrangment including piping & bypass valves. 150 mm dia

1

-

-

... More
Providing and fixing of 4.5 Kg. carbon-di-oxide type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase ingernal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming ro IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with internal charge.

16

-

-

... More
Providing and fixing 6.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge.

16

-

-

... More
Providing and fixing 9.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge.

2

-

-

... More
Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:13386 .

2

-

-

... More
Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEY confirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285.

2

-

-

... More
Providing and fixing 2 kg capacity clean agent-HFC 236FA Stored Pressure type fire extinguisher ISI marked under IS:15683 complete with imported Novec 1230 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions.

4

-

-

... More
Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc.

1500

-

-

... More
Machnical Parking - Specification as per approved by Engineer-in-charge

30

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C

660

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C

378

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.

72

-

-

... More
Wiring for light/ power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

2800

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.

-

-

-

... More
2x1.5 sq mm + 1x1.5 sq mm earth wire

3885

-

-

... More
2x2.5 sq mm + 1x2.5 sq mm earth wire

6300

-

-

... More
4x2.5 sq mm + 2x2.5 sq mm earth wire

1200

-

-

... More
2x6 sq mm + 1x6 sq mm earth wire.

300

-

-

... More
2x10 sq. mm + 1x6 sq. mm earth wire

200

-

-

... More
2x16 sq. mm + 1x6 sq. mm earth wire

150

-

-

... More
4x4 sq mm + 2x4 sq mm earth wire

1200

-

-

... More
4x6 sq mm + 2x6 sq mm earth wire

490

-

-

... More
4x10 sq mm + 2x6 sq mm earth wire

710

-

-

... More
4x16 sq mm + 2x6 sq mm earth wire

1155

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.

510

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

160

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.

-

-

-

... More
5/6 amps switch

10

-

-

... More
15/16 A switch

15

-

-

... More
3 pin 5/6 amp socket outlet

10

-

-

... More
6 pin 15/16 A socket outlet

15

-

-

... More
TV anteena Socket Outlet

10

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.

-

-

-

... More
1 or 2 Module (75mmX75mm) - For Telephone,TV outlet & Data

10

-

-

... More
3 Module (100mmX75mm) - For Socket outlet.

25

-

-

... More
4 Module (200mmX75mm) - For Socket outlet.

10

-

-

... More
6 Module (200mmX75mm) - For Socket outlet.

5

-

-

... More
8 Module (125 mmX125 mm)

6

-

-

... More
12 Module (200 mmX150 mm)

8

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
12 Way, Double Door

10

-

-

... More
8 way , Double door

2

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).

-

-

-

... More
6 Way (4+18), Double Door

14

-

-

... More
8 Way (4+24), Double Door

16

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. 12 way (4 + 36), Double door

28

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C series Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc,as required.

-

-

-

... More
Single pole

1424

-

-

... More
Triple pole and neutral

14

-

-

... More
Supplying and fixing following rating, double pole, 240 volts, MCB complete with connections, testing and commissioning etc. as required. 40 Amp

12

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, MCB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
40 Amp

16

-

-

... More
63 Amp

28

-

-

... More
Supplying and fixing of following rating double pole (Single phase and neutral) 240 volts, residual current circuit breaker (RCCB), having a current sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc. as required.

-

-

-

... More
25 Amps

42

-

-

... More
40 Amp

60

-

-

... More
63 Amp

84

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

350

-

-

... More
Supplying and fixing of following sizes of steel conduit alonwith the accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

... More
20 mm dia

950

-

-

... More
25 mm dia

3500

-

-

... More
32 mm dia

100

-

-

... More
40 mm dia

50

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

50

-

-

... More
Supplying and fixing Cable End Box (Loose wire box) (IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required.

-

-

-

... More
For 10 way, Double door SPN MCBDB

2

-

-

... More
For 14 way, Double door SPN MCBDB

10

-

-

... More
Supplying and fixing Cable End Box (Loose wire box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415V, on surface/ recess, complete with testing and commissioning etc. as required.

-

-

-

... More
For 6 way, Double door TPN MCBDB

14

-

-

... More
For 8way, Double door TPN MCBDB

44

-

-

... More
Supply, erection, testing and commissioning of following sizes of splitter of aluminium die cast body in suitable size of G.I. Box. 6 way

6

-

-

... More
Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & cover shall be as per technical specification.

-

-

-

... More
100 mm wide x 40 mm deep.

175

-

-

... More
150 mm wide x 40 mm deep.

135

-

-

... More
200 mm wide x 40 mm deep.

40

-

-

... More
Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification.

-

-

-

... More
150 mm wide x 50 mm deep.

32

-

-

... More
200mm wide x 50 mm deep

25

-

-

... More
250mm wide x 50 mm deep

4

-

-

... More
Supply & installation of 25 Amp single phase 240 Volt, 50 Hz, water tight (IP-55) socket outlet with interlocking switch complete with all the fixing accessories.

10

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single corecable etc. as required.

10

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

10

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/ LED fittings of all types, complete with all accessories and tube/lamp/ LED etc. directly on ceiling/ wall/ false ceiling with GI Chain included for fixing wherever required, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

1110

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 2x1.5 sq mm

1250

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). (For UPS Supply)

508

-

-

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet (near equipment point) and 25 A modular SP MCB, “C” curve (at accessible point) including connections, painting etc. as required.

10

-

-

... More
Supply of following sizes of 1.1KV grade aluminium conductor XLPE insulated and FRLS PVC sheathed armoured cable conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant).

-

-

-

... More
3.5 core, 300 sq.mm.

150

-

-

... More
3.5 core, 240 sq.mm.

240

-

-

... More
3.5 core, 185 sq.mm.

220

-

-

... More
3.5 core, 150 sq.mm.

50

-

-

... More
3.5 core, 120 sq.mm.

60

-

-

... More
3.5 core, 95 sq.mm.

75

-

-

... More
3.5 core, 70 sq.mm.

150

-

-

... More
3.5 core, 50 sq.mm.

20

-

-

... More
3.5 core, 35 sq.mm.

705

-

-

... More
4 core, 25 sq.mm.

20

-

-

... More
4 core, 16 sq.mm.

810

-

-

... More
4 core, 10 sq.mm.

290

-

-

... More
4 core, 6 sq.mm.

147

-

-

... More
2 core, 10 sq.mm.

40

-

-

... More
2 core, 6 sq.mm.

570

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
Upto 35 sq. mm

570

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

390

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
Upto 35 sq. mm (clamped with cable tie)

2012

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with cable tie)

245

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with cable tie)

185

-

-

... More
Above 185 sq. mm and upto 400 sq. mm (clamped with cable tie)

610

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
2 x 6 sq. mm (19mm)

20

-

-

... More
2 x 10 sq. mm (19mm)

2

-

-

... More
3½ X 35 sq. mm (32mm)

28

-

-

... More
3½ X 50 sq. mm (35mm)

2

-

-

... More
3½ X 70 sq. mm (38mm)

4

-

-

... More
3½ X 95 sq. mm (45mm)

2

-

-

... More
3½ X 120 sq. mm (50mm)

2

-

-

... More
3½ X 150 sq. mm (50mm)

2

-

-

... More
3½ X 185 sq. mm (57mm)

6

-

-

... More
3½ X 240 sq. mm (62mm)

10

-

-

... More
3½ X 300 sq. mm (70mm)

6

-

-

... More
4 X 10 sq. mm (25mm) (The Termination including 4 x 6 sq. mm cable)

26

-

-

... More
4 X 16 sq. mm (28mm)

52

-

-

... More
4 X 25 sq. mm (28mm)

2

-

-

... More
Supply & Laying of following sizes of 1.1KV grade multistranded copper conductor FRLS insulated wire including termination complete as required in existing cable tray.

-

-

-

... More
1C x 25 sq.mm PVC Insulated cu wire including end termination.

180

-

-

... More
1C x 16 sq.mm PVC Insulated cu wire including end termination.

100

-

-

... More
Supply, Installation, Testing & Commissioning of Earthing Junction Box size - 400mm x 300mm x 80mm made out of 16 SWG CRCA sheet with seven tank process & powder coating, earthing link (32mmx6mm copper strip), front door with glass as complete as required.

2

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

225

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

200

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness.

160

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness.

90

-

-

... More
600 mm width X 50 mm depth X 2.0 mm thickness

75

-

-

... More
750 mm width X 62.5 mm depth X 2.0 mm thickness

50

-

-

... More
900 mm width X 62.5 mm depth X 2.0 mm thickness

45

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

10

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

8

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness.

6

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness.

4

-

-

... More
600 mm wide x 50 mm depth x 2.0 mm thickness.

3

-

-

... More
750 mm wide x 62.5 mm depth x 2.0 mm thickness.

2

-

-

... More
900 mm width X 62.5 mm depth X 2.0 mm thickness

3

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

2

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

6

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness.

10

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness.

8

-

-

... More
600 mm wide x 50 mm depth x 2.0 mm thickness.

4

-

-

... More
750 mm wide x 52.5 mm depth x 2.0 mm thickness.

6

-

-

... More
900 mm width X 62.5 mm depth X 2.0 mm thickness

3

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

8

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

8

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness.

6

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness.

4

-

-

... More
600 mm wide x 50 mm depth x 2.0 mm thickness.

6

-

-

... More
750 mm wide x 52.5 mm depth x 2.0 mm thickness.

4

-

-

... More
900 mm width X 62.5 mm depth X 2.0 mm thickness

4

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm wide x 50 mm depth x 1.6 mm thickness.

6

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

8

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness.

4

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness.

4

-

-

... More
600 mm wide x 50 mm depth x 2.0 mm thickness.

3

-

-

... More
750 mm wide x 62.5 mm depth x 2.0 mm thickness.

2

-

-

... More
900 mm wide x 62.5 mm depth x 2.0 mm thickness.

3

-

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
120 mm dia (OD-120 mm & ID-103 mm nominal)

100

-

-

... More
200 mm dia (OD-200 mm & ID-175 mm nominal)

50

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

32

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

10

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

500

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

80

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

1600

-

-

... More
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.

120

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

12

-

-

... More
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.

12

-

-

... More
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.

12

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

550

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

380

-

-

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.

12

-

-

... More
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

120

-

-

... More
Providing and fixing earth bus of 50 mm X 5 mm GI strip on surface for connections etc. as required.

120

-

-

... More
Supply, Installation, Testing & Commissioning of 6 Mtr High hot dip Galvanized Octagonal Pole with bottom 130mm A/F, top 70 mm A/F made up of 3 mm thick HT plate and 220x220x12 mm base plate and 1000 mm long single arm bracket complete with 4 Nos M20 x 700 mmlong " J type " foundation bolts, suitable RCC foundation etc as complete as required.

16

-

-

... More
Supply, Installation, Testing & commissioning of Bollard LED 3000K 230-240Vac 50-60Hz CRI 80 Input power: 8W Height 800mm, Electronic driver ON/OFF CE and RoHS compliance TYPE: Bollard, IP rating IP65, impact resistance IK10. MATERIAL CHARACTERISTICS : Extruded aluminium bottom pipe Ø100 x H800mm with polycarbonate diffuser and integral base plate Ø180 with PG gland. Luminaire contains built in LED modules. Operating ambient temperature range is from -20°C to +40°C. Lumen output 300 lm, light source 96 power LEDs. Resistance to heat and fore for plasticpart should be 850 degree celcius. Housing Color Dark grey RAL 7043. CCE, CE and RoHS compliance. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted. Approved Make: Signify cat. ref. no. BCP151(Approved Make- Philips / Signify Cat No.-BCP151, or equivalent / Regent /Trilux ).

10

-

-

... More
Supply, Installation, Testing & Commissioning of 45W Led Street Light made up of pressure die cast aluminium housing with glasss cover and unique road optics  for better uniformity. The luminaire shall have minimum system lumen of 5400 lm and shall be with higher ingress protection  IP66 and impact resistance of IK07. Operating voltage range: 140-270V/50Hz, Average life L70B50: 50000 hours. Lumen efficacy of LED 120 lm/W,  CRI≥70, CCT-5700K, SDCM5. Powered by built-in potted LED driver gives constant light over wide voltage range. Shall have HV cutoff@325V protection for 8hours. Surge  protection 4 kV, power factor ≥0.95, THD≤ 10%. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL accredited lab to verify above parameters. Both the fixture and Driver should have separate BIS.(Approved Make- Philips / Signify Cat No.- BRP331 LED54 CW R5N PC PSU S1, or equivalent / Regent Trilux)

16

-

-

... More
Supply of surface mounted LED Downlighter made of pressure die cast alu. housing, LED Used shall be SMD type and fixture should have minimum efficacy =100lumens/watt with Minimum system Lumens 1800 with maximum system wattage of 18W Life of fixture (Including Driver) : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K, CRI 80, PF 0.9, Minimum Internal Surge Protection 2.5KV & , TThe fixture should comply with the parameters as per IS10322. The LED driver should comply to IS 15885 sec 13 for Harmonics, IS 10322 for Electrical Safety. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Similar to LDSER or Equivalenlt in Philips/Orient/Regent

72

-

-

... More
Supply of Recess LED Downlighter made of pressure die cast alu. housing, LED Used shall be SMD type and fixture should have minimum efficacy =100lumens/watt with Minimum system Lumens 2000 with maximum system wattage of 20W Life of fixture (Including Driver) : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K, CRI 80, PF 0.95, Minimum Internal Surge Protection 2.5KV & , TThe fixture should comply with the parameters as per IS10322. The LED driver should comply to IS 15885 sec 13 for Harmonics, IS 10322 for Electrical Safety. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Similar to venus or Equivalenlt in Philips/Orient/Regent

29

-

-

... More
Supply of Recess LED Downlighter made of pressure die cast alu. housing, LED Used shall be SMD type and fixture should have minimum efficacy =100lumens/watt with Minimum system Lumens 1500 with maximum system wattage of 15W Life of fixture (Including Driver) : 50000 burning Hrs. @ L70B50 Lumen maintenance, CCT of 6500K, CRI 80, PF 0.95, Minimum Internal Surge Protection 2.5KV & , TThe fixture should comply with the parameters as per IS10322. The LED driver should comply to IS 15885 sec 13 for Harmonics, IS 10322 for Electrical Safety. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Similar to venus or Equivalenlt in Philips/Orient/Regent

48

-

-

... More
Supply of linear receesed/suspended 4 ft luminaire made of extruded aluminium. Fixture should have minimum efficacy100lumens/watt and a minimum system lumen output of 2800(downlight) lumens and maximum system wattage of 28W. Luminaire should have Life of 50000hrs@L70B50 Lumen maintenance, CCT up to 4000/6500K, CRI 80, PF 0.95, THD10% and Internal Surge Protection 2.5KV. Fixture is available in 4 ft module with 50-55mm width options. The fixture should comply with the parameters as per IS10322. The LED driver should comply to IS 15885 sec 13 for Harmonics, IS 10322 for Electrical Safety. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Similar to LCRDL-20-C-50C or Equivalenlt in Philips/Orient/Regent

790

-

-

... More
Supply of Integral LED 4 ft IP40 Batten with powder coated Al housing and PC cover. The luminaire should have CCT of 5700K. Luminaire shall be designed to emit at least 2000 nominal lumens at a system efficacy of greater than 100 lumen/watt with maximum input power of 19± 1 Watt. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.9  The fixture should comply with the parameters as per IS10322. The LED driver should comply to IS 15885 sec 13 for Harmonics, IS 10322 for Electrical Safety. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Similar to LBLN-20-C or Equivalenlt in Philips/Orient/Regent

104

-

-

... More
Supply of LED 1x4 ft luminaire with CRCA white housing suitable with phosphochromate treatment and fully diffused suitable for hospitals. The luminaire should have CRI 80 and CCT of both 4000K / 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and an outstanding backlit solution efficacy of atleast 100 lumen/watt and maximum system wattage of 36 Watts.The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.9 and THD 10% and minimum inbuilt surge protection of 2.5kV. The fixture should comply with the parameters as per IS10322. The LED driver should comply to IS 15885 sec 13 for Harmonics, IS 10322 for Electrical Safety. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Height/depth of the luminaire must not exceed 80mm for site provision. Similar to LTRAQ-36-C-1x4-FC or Equivalenlt in Philips/Orient/Regent

59

-

-

... More
Supply of Heavy duty bulkhead surface type lighting fixture 10W - 1100lm made up of pressure die-cast aluminium housing and Polyster Powder coated die cast aluminium with High quality polycarbonate diffuser in opal finish for glare free light distribution.High efficiency long life LED module with SMD LED package mounted on MCPCB with lumen efficacy of 100 lm/W. Powered by integral electronic LED driver with CCT 6500, CRI80,THD10%, PF0.9, IP66, IK 09, Life class of 50,000 hrs @ L70, Operating Temperature: 0 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ. Driver Safety requirement standards:IS 15885, Test Report to be submitted, Photobiological Safety Norms: IS 16108, test Certificate to be submitted, Certification: LM79 for Luminaire, Lm80 for LED Source. Both the fixture and Driver should have separate BIS approval. (Approved Make- Philips / Signify Cat No.- Endura Bulkhead WT202 or equivalent / Regent Trilux).

24

-

-

... More
Supply of LED strip used to create comfortable lighting ambience,various needs for different customers/applications, superior light quality, mechanical flexibility, System efficacy up to 110 lm /W, IP20, 5mtr length, SDCM 3, Supply Voltage: 24VDC±10%, Approbation & Report: CB report, LM79, IP test, thermal test, CRI≥80, CCT: 2700K,. (Approved Make- Philips / Signify Cat No.- LS170S LED4 827 IP20 L5000 or equivalent / Regent Oriant ).

250

-

-

... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.. (Make : Havells / Oriant / Bajaj)

10

-

-

... More
Supplying of 250 mm sweep decorative Fresh air fan with all accessories suitable for operation single phase 230 volt 50 cycle per second per sec. AC supply etc. as required. in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning earthing etc. as required.(Make : Havells / oriant)

20

-

-

... More
DATA, TELEPHONE SYSTEM INCLUDING ACTIVE COMPONENTS Supply, Installation, Testing, Commissioning of Cat 6A, 10G U/FTP Cable, 23AWG LSZH as per technical specification. (Approved Make- Molex / systmax / Pendut)

19200

-

-

... More
Supply, Installation, Testing & Commissioning of Patch Panel Cat 6A U/FTP 24 Port- Loaded as per technical specification. (Approved Make- Molex / systimax / Penduit)

9

-

-

... More
Supply, Installation, Testing & Commissioning of Patch Panel Cat 6A U/FTP 48 Port- Loaded as per technical specification. (Approved Make- Molex / systimax / Penduit)

8

-

-

... More
Supply, Installation, Testing & Commissioning of Patch Cord Cat 6A U/FTP 3 feet as per technical specification. (Approved Make- Molex / systimax / Penduit)

320

-

-

... More
Supply, Installation, Testing & Commissioning of Patch Cord Cat 6A U/FTP 7 feet as per technical specification. (Approved Make- Molex / systimax / Penduit)

320

-

-

... More
Supply, Installation, Testing, Commissioning of Cat6A, 10G, U/FTP, Information Outlet including G.I. Box and modular Wall / face plate as per technical specification. (Approved Make- Molex / systimax / Penduit)

640

-

-

... More
Supply , Installtion , Testing and comissioning of 15U wall mount rack with fans , 2 cable managers, satationary shelf , 2 Nos of hardware pkts as per technical specification. (Approved Make- Rittal /Netrack / Valrack ( Legrand) / WQ)

7

-

-

... More
Supply,Testing & Commissioning of Network Rack 42 U with below included: Network Rack 800W x 2000H x 800D, Top cover with 4 x cutout, 2 x cutout for cable entry. Bottom cover with 4 x cutout for cable entry. All cutouts blanked with Plastic caps. 2 pairs, 42 U 19" Profile Type angle,Front & etc. complete as per technical specification. (Approved Make- Rittal /Netrack / Valrack ( Legrand) / WQ)

1

-

-

... More
Supply, Installation, Testing & Commissioning of 24 port 10/100/1000Mbps, 4SFP module, L-2 Switch, POE as per technical specifications. (Approved Make- Cisco / HP / Juniper)

9

-

-

... More
Supply, Installation, Testing & Commissioning of 48 port 10/100/1000Mbps, 4 SFP Module, L-2 Switch, POE as per technical specifications. (Approved Make- Cisco / HP / Juniper)

8

-

-

... More
Supply, Installation, Testing & Commissioning of IP Based voice Communication System with 04 Port Voicemail ,04 Port FXS ,04 Port FXO ,1 PRI Trunk lines (30 Ch) Circuit with CLIP Facility , 350 IP users License ,01 Nos. IP Operator Console,100 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup, - Redundant server in Active-Passive mode as per technical specification. (Approved Make- alcatel / NEC / Siemens )

1

-

-

... More
Supply, Installation, Testing & Commissioning of Type 1 IP Phone . Graphic LCD display with backlight 3 user accounts with multi-line appearance keys Local and company-wide phone directories. (Approved Make- alcatel / NEC / Siemens )

320

-

-

... More
Supply, Installation, Testing & Commissioning of Type 2 IP Phone 1 VoIP account , Full duplex speaker phone, IPV6, 2xLAN, PoE. (Approved Make- alcatel / NEC / Siemens )

2

-

-

... More
Supply, Installation, Testing & Commissioning of Core Switch 24 1Gb/10GBASE-T ports, 2 10Gb/40Gb QSFP+ ports, 2 x 10G SFP+ Ports can support virtual stacking up to 6 Switches 4, 2 populated power supplies slots, with suitabe fan module slots, supporting RIP, OSPF, VRRP L3 protocols from day one as per technical specification. (Approved Make- alcatel / NEC / Siemens )

1

-

-

... More
Supply, Installation, Testing & Commissioning of SFP+ 10GBASE-SR 10 Gigabit Ethernet Optics, 850 nm for up to 300 m,transmission on multimode fiber (MMF). (Approved Make- alcatel / NEC / Siemens )

17

-

-

... More
Supply, Installation, Testing & Commissioning of 6 Core OM4 Multimode Fiber Cable as per technical specification. (Approved Make- Molex / systimax / Penduit)

650

-

-

... More
Supply, Installation, Testing & Commissioning of 12 Port LC multimode loaded LIU. (Approved Make- Molex / systimax / Penduit)

7

-

-

... More
Supply , Installtion , Testing and comissioning of 24 port loaded LIU for core switch to access switch connectivity over fiber. (Approved Make- Molex / systimax / Penduit)

1.75

-

-

... More
Supply, Installation, Testing & Commissioning of LC - LC Fiber patch cord OM4, 3 Mtrs. (Approved Make- Molex / systimax / Penduit)

30

-

-

... More
Supply, Installation, Testing & Commissioning of 6 Core, Single Mode, OS2 as complete as required. (Approved Make- Molex / systimax / Penduit)

100

-

-

... More
Supply, Installation, Testing & Commissioning of wifi Access point as complete as required. (Approved Make- alcatel / NEC / Siemens )

6

-

-

... More
FIRE ALARM SYSTEM (ADDRESSABLE TYPE) AND PA SYSTEM Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel.

1

-

-

... More
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.

1

-

-

... More
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt active reset, acknowledge and silence switches complete as required.

1

-

-

... More
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector acclimate type sensetive level (0.524%) OVS/ft. complete with mounting base complete as required.

286

-

-

... More
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.

2

-

-

... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required.

18

-

-

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required.

10

-

-

... More
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. (75 DBA @3 mtr. & 75CD flashing)

18

-

-

... More
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.

133

-

-

... More
Supplying, installation, testing & commissioning of fault isolator complete with base as required.

16

-

-

... More
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.

3800

-

-

... More
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.

1

-

-

... More
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.

1

-

-

... More
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.

58

-

-

... More
Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required.

5

-

-

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. Speaker cable Single pair, 2-core, 1.5 sqmm

900

-

-

... More
IP CCTV SYSTEM- Supplying, installation, testing & commissioning of 4MP or better IP Network TDN Low-Light IR Rugged Dome Camera, 1/3" CMOS or better, 4MP (2592 x 1520) @ 20fps or better, triple stream at various resolution up to 25fps, Min. Illumination required 0.01 lux @ F2.0 (color), 0 Lux IR On, 4 IR LEDs Smart IR with upto 30m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 55db, Shutter Speed 1 - 1/100,000; Adavance Video Compression technology such as H.265 & H.264 High Profile & MJPEG , Triple stream, , Stream Encryption, 256GB SD card support, PoE (802.3 af) and 12V DC, Max 6W, IP 66/67, IK 10 vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant, UL.

48

-

-

... More
Supplying, installation, testing & commissioning of 4MP IP Network TDN Low-Light IR Rugged Bullet Camera, 1/2.7" CMOS or better, 4MP (2592 x 1944) @ 25fps or better, triple stream at various resolution up to 25fps, Min. Illumination required 0.008 lux @ F1.6 (color), 0 Lux IR On, 4 IR LEDs Smart IR with upto 50m IR distance, Auto ICR (Infrared Cut Filter) 120dB True WDR, S/N Ratio 50db, Shutter Speed 1/8 - 1/30,000; Adavance Video Compression technology such as H.265 & H.264 High Profile & MJPEG , Triple stream, 2.7 to 13.5mm 5X motorized focus & zoom lens, Field of View FoV H:85°-24°, BLC, HLC, 3DNR White Balance, Minimum Edge Intelligence Video Analytics : Motion Detection, Face Detection, 4Privacy Mask, 4 Region Of Intreset, TLS1.2, AES-128/256, SSH/Telnet closed, Stream Encryption, 256GB SD card support, PoE and 12V DC, Max 6W, IP 66/67, IK 10 vandal proof with Die Cast Aluminium Housing, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S/G/T compliant, UL

4

-

-

... More
Supplying, installation, testing & commissioning of Outdoor 1/2.8 inch CMOS 2MP or better, IR PTZ Camera ; 40x Optical Zoom & 16x Digital Zoom, tripple stream; IR distance: 200 meter or better; Lens 4 -175mm Motorized Auto focus zoom lens; Memory card slot: Min 256GB support. Minimum Illumination- Sense up on- Color: 0.001 lux color, B/W: 0 lux IR On, WDR 120dB, Edge Video Analysis Video Motion Detection, Intrusion, Lioter, Counter & Tampering, 3DNR, BLC, HLC, White Balance, EIS, Defog, Mechanical switchable IR filter (Auto ICR), Pan Range 360° continuous, Tilt Range -10° to 90°, Pan/Tilt Modes - Pan: 0.1°/s - 180°/s; Tilt: 0.1°/s - 90°/s, Presets 200, Preset Accuracy 0.25 Deg, 16 Patrol & Tours, Alarm I/O - 2In/2Out, 2-Way Audio- 1/1 Channel In/Out, 256GB Memory card slot, 4 individually configurable privacy masks, 4 Region of Interest, POE+ or 24VAC 3A for indoor/Outdoor application, IP66/67, IK 10 ; Certifications: ONVIF Profile S/G/T compliant, UL

1

-

-

... More
Supplying, installation, testing & commissioning of IP Network Video Storage Manager Server Channel Network Video Storage Manager Server - NSM shall have Intel® Xeon Silver 4210R, 2.2 GHz or better, Mnimum 32GB RAM, 1+1 750W hot plug redundant power supply, OS drive: 2 x 240 GB in RAID 1; 12 field upgrade up to 20 TB SATA/SAS hard drive options for Video Recording, Data RAID Level: 0, 1, 5, 6, 10. NIC card 4 x 1GbE supporting network throughput of 800 MBPS, Windows Server 2019 R2 64- bit/Windows10 64-Bit IOT Operating System, Microsoft SQL Server/Express 2019. NSM Shall support upto 128 Cameras @ 1080P, 25fps, 09 Remote Client Licenses inbuilt, Web Clients, Monitor Layout up to 4x4, Digital Signature for Video Clip, Continous & Motion Based Recording options, up to 8X forawrd & backward palyback, Playback search as date/time timeline, time jump FWD/REV, bookmarks, calendar, preview, film strip, event search and SMART Motion Search as a min. NVR shall be ONVIF S/G/T certified and liested on ONVIF Website. NVR shall Support Two -Way Audio with cameras equiped with Microphone & Speaker. Each NSM shall be offered with 128TB Video Stoarge for Recording for 30 days.

1

-

-

... More
Supply, Installation, Testing and commissioning of Managable 24 port Switch with Power on Ethernet (PoE) enabled, 10/100, RJ45 Access ports with PoE complete as required.

8

-

-

... More
Supply, installation, testing and commissioning of of 16 TB HDD all accessories complete as required.

2

-

-

... More
Supply installation and commissioning of 55 inch LED monitor for disply of camera.

2

-

-

... More
UPS SYSTEM Supply, Installation, Testing & Commissioing of 30 KVA UPS in paralleling mode at 0.99 input power factor with SNMP card, compatible for BMS connectivity on backnet/MODBUS, Inbuilt Isolation transformer as per specification given in the document with following broad features. THD(i) shall be less than 3% in the entire loading range, UPS shall carry design output at 40 deg, Shall have soft start and hold of for incoming supply., Invertor capability to supply 150% load for 5 sec. Three Phase Input and Three Phase Output. (Input - 340V - 470V, Three Phase, 4 wire. / Output - 400-415 Volt, Three Phase, 4 Wire.), Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells., Battery shall be external type with rack and suitable for 15 minute backup on 100% load., Suitable size of copper cable between UPS and battery bank shall be provided, UPS shall be compatible for 3 nos unit in parallel operation. (Synchronize). Parallel operation kit shall be supplied with UPS., UPS described as above

2

-

-

... More
PASSENGER LIFT , LIFT PIT SIZE : 1900(W) X 2500 (D) X 1000 DOOR OPENING, Supplying, Installation, Testing & Commissioning of 13 Passenger (884 Kg) Lifts (Gearless), with Machin Room having contract speed of 1.5 MPS serving different floors in the lift shaft as per detailed specifications enclosed and as under:-, Speed -- 1.5 MPS, Floors --B+7, Travel -- 36 Mtrs Approx. Stops & door opening - -- 6/1200 mm WideX 2100mm High, Controller: A.C. variable voltage & variable frequency drive., Automatic rescue device complete with dry maintenance free batteries as required, Operation: Microprocessor based single automatic push button / Duplex / Triplex selective collective with / without attendant., Power-415 V, 3 phase, 50 Hz, 4 wires system, Type of doors, (i) Car Power operated, Two Speed Stainless Steel hail line finish. (SS 304 Grade), (ii) Landing doors : Stainless Steel hail line finish. (SS 304 Grade), Hand rail not less than 600mm long at 900mm above floor level to be fixed on all the three sides adjacent to control panel in the lift car., The Lift shall be provided with Brail System., Ceiling as per manufacturer's standards with Fan & LED Lights., On each Landing outside the lift, a steel plate with illumination sign shall be provided with written on it:- DO NOT USE LIFT IN CASE OF FIRE. Fire man switch at ground floor to be provided. Interlocking provision with Fire detection system shall be provided., Voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or stops at a floor served by the elevator., IP based CCTV interfaced to be provided., BMS interface for lift position & 3 way Intercom system., 2 Hour Fire rated door. Manufacturer shall be submit the certificate alongwith supply of material from NABL approved Lab., Lift described as above

3

-

-

... More
SOLAR PHOTO VOLTAIC POWER GENERATION SYSTEM- Supplying installation testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including all the required accessories like Solar PV module, Grid Tie invertor, arrey junction box, cabling & wiring, earthing, surge protection device, FRLSame structure for mounting of solar panel. The cell shall be poly crystaline silicon cells of 6 inch each and module efficiency shall be more than 17%. Solar module shall have linear output warranty with degradation not exceeding 0.7% FRLSom 2nd Year onwards. Minimum 80% power output must be assured at end of 25 years. The FRLSont glass of solar module shall be low iron tempered glass ARC type. Termination box shall be Thermo-plastic, IP 67 or better, UV resistant with built-in-bypass. The nominal power of a single PV module shall be minimum 540 Wp or higher. Positive power tolerance modules only to be used. RF identification tag for each solar module shall be provided inside the module and must be able to withstand environmental conditions. The solar panel shall be complience of IEC 61215, IEC 61730 certified by TUV Rheinland / UL. The solar panel shall be installed as per BOQ & detailed technical specification.

30

-

-

... More
4.0 KG UL Listed Cylinder Automatic Pre-Engineered System filled with Clean Agent FK 5-1-12, Fitted with DLP Valve mounted on Cylinder Push-In-Connector for Tube, Mounting Bracket, End of Line Adopter and UL Listed Low Pressure Switch for Monitoring System Activation.

10

-

-

... More
9.0 KG UL Listed Cylinder Automatic Pre-Engineered System filled with Clean Agent FK 5-1-12, Fitted with DLP Valve mounted on Cylinder Push-In-Connector for Tube, Mounting Bracket, End of Line Adopter and UL Listed Low Pressure Switch for Monitoring System Activation.

2

-

-

... More
UL Listed Linear Pneumatic Heat Detection Tube with all necessary fittings & supports, HR Grade,UV Protected, MultiLayered, Made of Special Modified Polyamide Material, Inner diameter 4mm, Outer Diameter 6MM, Operating Pressure 15 8Bar, Maximum Pressure 30 Bar at maximum Temperature of +65 Degree C, Pressurized

500

-

-

... More
Master Control Unit with Audio Visual Alarm with wiring to make complete system operational. The Control Panel should have provision for integration with Fire Alarm/SCADA/BMS System (Supply to be provide by the end client at 220 Volt AC).

12

-

-

... More
DG SETS, DIESEL GENERATING SET, Supply, Installation testing and Commissioning of Silent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation / PLC based synchronization, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per latest CPCB norms) fabricated out of CRCA sheet of 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following., Diesel Engine - Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system. Instrument Panel - Engine mounted Instrument Panel fitted with and having digital display for followings : Start stop switch with key, Water temperature indication, Lubrication oil pressure indication. Lubrication oil temperature indication. Battery charging indication RPM indication Over speed indication Low Lube oil trip indication Engine hours indication Alternator - Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for bus duct termination / cable termination as required. Note : - Alternator should have with all other accessories as per specified in Technical specfications. Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer. Inbuilt Fuel tank of standard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete. Daily service Fuel tank of 990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system, level indicators and all standard accessories etc. as required. Exhaust Silencer - Exhaust manifold with residential silencer. The D G set should be supplied with required hardware for external PLC based auto synchronization, auto load sharing, auto load management system. Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH. Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications.320 KVA

2

-

-

... More
Supply, Fixing, testing and Commissioning of Exhaust gas piping system of Class `B' MS pipe as per IS:1239 for upto 150 mm dia and for 200 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, flanges, painting over primer coat, with mineral wool / rock wool insulation of minimum 75 mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil. The measurement shall be done on the basis of centre line. (Stack height should be in accordance with emission regulations of CPCB, which will go well above the top most terrace) The exhaust piping system should be suitable for upto 550oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC. (The rates are exclusive of support structure) (Note - Final size of exhaust pipe will be confirmed by the DG vendor after calculating the actual back pressure and submit the same to client / consultant for approval) 200 mm dia (wall thickness - 4.8 mm)

70

-

-

... More
Supply & fixing of SS Bellow of following diameter 200 mm dia

4

-

-

... More
Supply & fabrication of D G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MS angle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation.

4500

-

-

... More
SUB- STATION WORK 11 KV HT VCB FOUR BREAKER PANEL BOARD (INDOOR TYPE) Supplying, Installation, Testing & Commissioning of indoor type floor mounted metal clad, 11 KV VCB panel with 3 nos VCBs, totally inclosed & fully interlocked, horizontal drawout, horizontal isolation type breaker as per IS 13118, as amended up to date and additional specifications, having capacities as mentioned below, single break, trip free mechanism, manually charged and manually closing breaker suitable for use on 11 KV, 3 phase, 50 Hz A.C. supply with short circuit fault level of 350 MVA, complete with self contained, fully interlocked, rack in and rack out mechanism, air insulated but encapsulated copper bus bars of 630 Amp capacity, breaker featured with mechanical ON/OFF indicator with hand trip device. Spring release coil, shunt trip coil and auxiliary switch of 4 NO + 4 NC and equipped with following switchgears and accessories i/c connections for 3C x 185 sq.mm. XLPE 11 KV cable (cable entry from bottom), end termination with heat shrinkable jointing material etc. as required. (Note - Cost of end termination not included in this item). ( Approved Make- ABB / SIEMENS / SCHNEIDER / L & T) a) 1 No, 630 Amp, VCB., b) 1 No.- 11 KV / 110 Volt PT class 0.5 accuracy and 100 VA burden with 1 No. voltmeter (0-12 KV), digital type, selector switch for voltmeter and protection MCB for HT Metering up to 12 KV on incommer., c) 1 No.- (0 - 50 A) dual scale Ammeter, digital type, selector switch for ammeters., d) 1 No - Microprocessor based numericak relay with O/C, E/F and S/C protection., e) 1 No - set of dual core dual ratio 3 CTs 50/5A of 15 VA burden and accuracy class 0.5 for metering and class 5P10 for protection., f) 1 No. electronic type digital energy analyser having 30 days memory and parameters of KW, KWH, Power factor, frequency etc. Suitable for BMS compatible with all accessories. g) 1 No. hooter with hooter acceptance and reset push button., h) 1 No - Red, Yellow & Blue for phase indication., i) 1 No - Amber for Trip indication. j) 1 No - Red `ON' Green `OFF'indication., k) 1 No - Spring charge indication., l) 1 No - Auto trip indication., m) 1 No. hooter with hooter acceptance and reset push button., n) 1 No. master trip relay. ( Electromechanical Type ), o) 1 No.Trip ckt supervision relay. (Electromechanical Type ), p) 2 No.auxiliary relay for transformer fault., h) Power pack., H.T. Panel described as above

1

-

-

... More
630 KVA, 11KV/415V OIL TYPE TRANSFORMER Design, manufacture, supply, installation, testing and commissioning of 630 KVA, 11 KV /0.415 KV, 3 phase, 5.0 % impedance, 50 Hz delta/star-11 connected, outdoor type, copper wound transformer, oil immersed ONAN cooled, complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent with on Load Tap changing (OLTC) arrangement on HV side with Tapping for variations of high voltage from (+) 5% to (-) 15% in steps of 1.25% each with integrated microprocessor based RTCC Panel, bi-directional roller, diagrams & rating plate, Oil temperature indicator, & Winding temperature indicator, Buchholz relay, weather proof Marshalling Box, lifting lugs, first filling of oil, weather proof H.T/L.T cable box etc. complete as per specification. All relays, contacts & CT terminals to be wired upto marshalling box. The Transformer losses should confirm to IS - 1180 Part-1 (2014) with energy efficiency level-1. ( Approved Make- Sudhir Intra / Crompton / Esennar / Kotsins / Dynamic)

1

-

-

... More
MAIN L.T. PANEL WITH PLC BASED LOAD MANAGER Design, manufacture, supply inspection, handling, assembling, affecting proper connections, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type Main L.T. Panel with PLC based load manager, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable as required. All incoming & outgoing MCCB's shall be microprocessor based with O/L & S/C and E/F protection. ( Approved Make- Application Control / Neptune / Tricolite / Ambit / Adlec) All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link. The breaking capacity specified for all ACB's and MCCB's breakers is Ics value (service rating). The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, cast resin type CT's & PT's, etc. Separate CT's shall be provided for protective and measuring system and for APFCR of capacitor bank with suitable VA. Each section of Panel shall have door opearted light of sufficent lux to illumunate that section & each section of capacitor, buscoupler, transformer and DG incomers shall have exhaust fans for ventilation purpose. INCOMERS from 1Nos. 630 KVA TRANSFORMER 1 nos. 1000 AMP. Four Pole, Electrically operated 3 position motorized (220 V AC) drawout type Air Circuit Breaker with all inbuilt protections, with microprocessor based release, over current, earth fault, short circuit, Instantaneous short circuit, closing coil (220 V AC), trip coil (24 V DC), shunt trip release, inbuilt U/V release with LCD / LED display for event history with intruppted current value during fault & measurement of current parameters, 50 KA Breaking Capaciy with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947, The ACB shall be electrically interlocked with the bus coupler, DG incomers and other transformer incomers., 1 nos. 20 KVAR capacitor bank with 63 amp TP MCCB (25 KA) for each transformer incomer., 1 nos. 32 amp TP MCCB (25 KA) for OLTC (for each transformer incomer), Protection releases / relays, Metering & Accessories for each Transformer incomers, Surge Protection Device - Type - 01 (Class - B), 10/350 µ sec. (100 / 25KA) , Over Voltage / Under Voltage relay / release (3 phase) with timer., Backup earth fault relay. Master trip relay. Trip Circuit Supervison relay., TNC switch., Auto manual selector switch. 1 nos. 0-500 volt range digital type voltmeter with selector switch, 1 set of 3 CT's of ratio 1000/5A, Class 1.0 accuracy 15 VA burden for metering. 1 set of 3 CT's of ratio 1000/5A, Class 1.0 accuracy 15 VA burden for APFCR. 1 set - 415 / √3 / 110 / √3 Class 1.0 accuracy 100 VA burden PT along with primary and secondary fuse. 1 no. CT's of ratio 1000/5A, Class 5P20 for protection. 1 no. 0-1000 Amp range digital type ammeter with selector switch. Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation. Power factor meter. Frequency meter. 3 Nos. LED type phase indicating lamps, each lamp shall be with bakup MCB along with hooter, auxillary relay, 2 sets of push buttons. 5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup MCB.

-

-

-

... More
INCOMERS from 2Nos. 320 KVA D G sets. 1 nos. 630 AMP. Four Pole, Electrically operated 3 position motorized drawout type Air Circuit Breaker, with all inbuilt protections, with microprocessor based releases/relays, over current, earth fault, short circuit, Instantaneous short circuit, shunt trip release, closing coil (220 V AC), trip coil (24 V DC), inbuilt U/V release with LCD / LED display for event history & measurement of current parameters with intruppted current value during fault , 50 KA Breaking Capaciy with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947. Protection releases / relays, Metering & Accessories for each D G set incomers Over Voltage / Under Voltage relay / release (3 phase) with timer. IDMT earth fault relay. Backup earth fault relay. Master trip relay. Trip Circuit Supervison relay. Reverse power relay. TNC switch. Auto / manual / test selector switch 1 Set - 415 /v3 / 110 / v3 Volts PT Class 1.0 accuracy and 100 VA burden along with primary & secondary MCB. 0-500 volt range digital type voltmeter with selector switch 1 set - 3 CTs of ratio : 600/5A , Class 1.0 accuracy 15 VA each burden for metering. 1 set - 3 CTs of ratio : 600/5A , Class 5P20 accuracy 15 VA each burden for protection. 0-600 Amp range digital type ammeter with selector switch. Energy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI (EM 6400 of Conzerve or equi.) with RS 485 communication port for communication / report generation. Frequency meter. Power Factor meter. 1 No -12 point Temp Scanner with Alarm/ Trip contact for winding & bearing. 3 Nos. LED type phase indicating lamps, each lamp shall be with bakup HRC fuse/MCB along with hooter, auxillary relay, 2 sets of push buttons. 5 Nos. LED type indicating lamp for indicating the status of feeder - ON / OFF / TRIP / Trip circuit healthy / DC supply healthy. Each lamp shall be with bakup HRC fuse/MCB. 8 window annunciator with accept / reset / test push button for each DG set for following indications and alarm : set fail to start, engine over heat, high temperature, excitation failure, low lube oil pressure, over speed, low fuel oil level, cooling water flow failure, breaker trip, generator fault, DC control supply failure, out of limit voltages and spares. Push buttons for Test. Accept. Reset. Fault Reset. Engine start, Engine stop, ACB close, ACB Trip Emergency stop. Shut down due to low lube oil pressure/High water temp/Over speed/Low fuel level - set of 4 indication lamps. D G control incorporating engine start / stop indicating three attempt facility and on failure to start, engine lock out. 1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (320 KVA) Note : In normal case all three lamps shall be ON to indicate that incoming power supply is available. In case of power resumption after failure buzzer shall ring to indicate the power supply is resumed. There shall be one push button to acknowledge the same. The ACB shall be electrically and mechanically interlocked with the bus coupler and Transformer incomers. BUSCOUPLER 1 nos 630 AMP. Four Pole, Electrically operated 3 position motorised (220V AC) drawout type ACB's, closing coil (220V AC), trip coil (24V DC), with inbuilt U/V release 50 KA Breaking Capacity with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:13947-2. The bus coupler shall be electrically interlocked with all incoming ACB's in such a way that at any one time two supply should not get mixed up. BUS BARS, Bus Bar Make :- HINDALCO / JINDAL. 1250 AMP TPN busbars of aluminium alloy as per SLD. PLC for load management / automation Design, manufacturing, testing at works, supply of PLC BASED , AUTOLOAD TRANSFER, AUTOLOAD BALANCING PANEL FOR 2 nos. 320 KVA D.G. sets complete as required to acheive the desired functions. (Make : ALLEN BRADLEY / SIEMENS / MITSUBISHI / ABB) PLC shall be provided in main LT panel for interlocking between different incomers and bus couplers to avoid unintentional paralleling of different supplies. PLC shall have with VIEW PANEL In addition to required hardware and software following components shall also be provided. Based on the load requirement only required no. of DG sets shall be operated. Monitoring of DG set safeties (mechanical as well as electrical). PLC Hardware as required Auxiliary relays/contactor/metering/protection etc as required 230 V AC, UPS of suitable rating Annunciators as required One no. Battery charger set consisting of Transformer / Rectifier, DC ammeter, DC voltmeter, Charging rate selector switch, Off/Trickle/boost. All control wiring from PLC to various feeders with min. of 2.5 sq mm copper FRLS cable. OUTGOINGS: All outgoing feeder shall be provide with ON / OFF / Trip indication lamp with protection MCB's, & Dual Source energy Meter. 01 Nos. 630 Amp TP Moulded Case Circuit Breaker (25 KA) 02 Nos. 400 Amp TP Moulded Case Circuit Breaker (25 KA) 04 Nos. 315 Amp TP Moulded Case Circuit Breaker (25 KA) 01 Nos. 250 Amp TP Moulded Case Circuit Breaker (25 KA) 02 Nos. 200 Amp TP Moulded Case Circuit Breaker (25 KA) 03 Nos. 160 Amp TP Moulded Case Circuit Breaker (25 KA) 15 Nos. 100 Amp TP Moulded Case Circuit Breaker (25 KA), 01 Nos. 63 Amp TP Moulded Case Circuit Breaker (25 KA) Main L.T. Panel Described as Above.

1

-

-

... More
AUTOMATIC POWER FACTOR CORRECTION PANEL (CAPACITOR PANEL) Design, Manufacturing, Supply, Receiving, Unloading, Shifting, testing & commissioning of 14 SWG CRCA sheet steel fabricated cubical type 225 KVAR A P F C Panel consisting of 5 /10 / 25 / 50 KVAR (at 415 Volts rated voltage of bank shall be 440 Volts) capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust & vermin proof, front operated construction, enclosure class - IP 42, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623 . All out going MCCB's shall be thermal-magnetic based with inbuilt O/L & S/C release. All MCCB's shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link. The breaking capacity specified is Ics value. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CT's, PT's, etc. AC3 duty contactors should be used for switching individual capacitor banks. The fault withstanding capacity of panel & its control gear shall be min. 25 KA rms for 1 sec. Each section of capacitor panel shall have Verticle hood & exhaust fans for ventilation purpose. INCOMING Incomer circuit breaker has been included in the main panel. 1Nos- (500 A) digital Ammeter with selector switch Micro processor based automatic power factor control relay (3 phase) (including power factor meter) in 8 steps for automatic cut off or add on capacitor units to keep the power factor at 0.95 with variation of loads. All associated auxiliary contactors / relays shall be provided with in the scope of work. Phase indicating lamps with HRC fuses, and indicating in each capacitor chamber unit to indicate On/Off status of capacitor unit. BUS BARS 600 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coding and insulated by heat shrinkable sleeves and clips on shrouds for joints. OUTGOINGS 2 nos. of 125 AMPS TPN MCB (35 KA) and 140 amps AC3 duty contactor with 50 KVAR, MPP resin filled, super heavy duty ,440 V capacitor bank, start stop push button for manual operation including on/off indicating lamps and delay timer complete. 4 nos. of 63 AMPS TPN MCB (35 KA) and 80 amps AC3 duty contactor with 25 KVAR, MPP resin filled, super heavy duty ,440 V capacitor bank, start stop push button for manual operation including on/off indicating lamps and delay timer complete. 2 nos. of 32 AMPS TPN MCB (35 KA) and 40 amps AC3 duty contactor with 10 KVAR, MPP resin filled, super heavy duty ,440 V capacitor bank, start stop push button for manual operation including on/off indicating lamps and delay timer complete. 1 no. of 16 AMPS TPN MCB (35 KA) and 20 amps AC3 duty contactor with 5 KVAR, MPP resin filled, super heavy duty ,440 V capacitor bank, start stop push button for manual operation including on/off indicating lamps and delay timer complete. Capacitor Panel as described above

1

-

-

... More
11 KV END TERMINATION: supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 3C x 240 Sqmm, 11KV XLPE

2

-

-

... More
11 KV H.T. CABLE: Supplying of 11 KV grade aluminium conductor, cross linked polyethylene (XLPE) insulated individual core screened, flat steel/strip armoured PVC sheathed cable complete as required. 3C x 240 Sqmm, 11 KV XLPE

100

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Above 120 sq. mm and upto 400 sq. mm

100

-

-

... More
Supply of following sizes of 1.1KV grade Copper conductor XLPE insulated and FRLS PVC sheathed armoured control cable including termination conforming to relevant IS. (Cable shall be purchased only after approval of cable schedule by architect / consultant).

-

-

-

... More
4 core, 2.5 sq.mm.

50

-

-

... More
10 core, 2.5 sq.mm.

150

-

-

... More
12 core, 2.5 sq.mm.

150

-

-

... More
SAFETY EQUIPMENT Supplying & Placing of First aid box as approved by St.John Ambulance Brigade /Indian Red Cross society conforming to IS : 2217 - 1963 etc as reqd.

2

-

-

... More
Supplying & Installation of Shock treatment chart duly mounted on a wooden frame with glass on, as required in 2 languages (Hindi & English) etc. as reqd

2

-

-

... More
Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS 15652-2006 etc. as reqd.

20

-

-

... More
Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd.

5

-

-

... More
DISTRIBUTION PANEL Design, Manufacturing, Supply, Receiving, Unloading, Shifting, installation, testing & commissioning of cubicle type totally enclosed free standing type moisture, dust and vermin proof Floor Distribution Panel made out of 2.0 mm thick & front cover 1.6 mm thick CRCA sheet complete with following equipments, including digital ammeter with inbuilt ammeter selector switch, digital voltmeter with inbuilt voltmeter selector switch, indicating lamps, CT's, internal wiring with suitable size wires / cable, interconnection, painting complete as per specification & drawing. All the incomming and outgoing MCCB shall have 25 KA Ics.The incoming MCCB shall be microprocessor based with O/L & S/C and E/F protection and all Outgoings up to 250A MCCB's may be thermo-magnetic based O/L & S/C protection. All outgoing MCB's shall be C type with 10 KA breaking capacity.

-

-

-

... More
ELECTRICAL PANEL - 1 to 7 (BASEMENT TO 6TH FLOOR) INCOMING 1 No. 100 Amp FP Moulded Case Circuit Breaker. (25 KA) 1 No. Digital Multifunction Meter, CT's control MCB. 1 Set of phase indicating lamps with Single Pole MCB. 1 Set of ON / OFF indicating lamps with Single Pole MCB. BUS BARS 200 Amp FP aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 04 No. 25 Amp FP MCB (10 KA). 04 No. 40 Amp FP MCB (10 KA). 04 No. 63 Amp FP MCB (10 KA). Electrical Panel -1 to 7 described as above

7

-

-

... More
LIFT PANEL (TERRACE FLOOR) INCOMING 2 No. 160 Amp FP Moulded Case Circuit Breaker. (25 KA) 1 No Fixed type Automatic transfer switch 100 Amp rating in open frame with  live to live transfer time  150ms. The ATS should have complete switching neutral with zero position having positive isolation and on load manual operation complying to IEC 60947-3 and IEC 60947-6-1. The control unit shall be integral part of the ATS. 1 No. Digital Multifunction Meter, CT's control MCB. 2 Set of phase indicating lamps with Single Pole MCB. 2 Set of ON / OFF indicating lamps with Single Pole MCB. The Panel shall have a provision for AUTOMATIC FIRE DETECTION GAS SUPPRESSION flooding system for complete panel of each compartment / section including gas bank of required capacity (Note - Gas Supression flooding sysytem having seperate item). BUS BARS 200 Amp FP aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 4 No. 63 Amp TP MCCB (25 KA) 4 No. 40 Amp DP MCB (10 KA) Lift Panel described as above

1

-

-

... More
UPS INCOMING PANEL- (2 x 30 KVA) Supply, installation, testing & commissioning of Sheet steel enclosure suitable for installing of 100A FP MCCB including providing cable termination link in incloming / outgoing side. The item does not include the MCCB.

2

-

-

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100A, 16 KA,TPMCCB

2

-

-

... More
UPS OUTGOING PANEL- (2 x 30 KVA) INCOMING 2 No 100 Amp FP Moulded Case Circuit Breaker (25 KA) 2 No. Digital Multifunction Meter, CT's control MCB. 2 Set of phase indicating lamps with Single Pole MCB. 2 Set of ON / OFF indicating lamps with Single Pole MCB. BUS BARS 200 Amp FP copper busbar. OUTGOING, 10 No 40 Amp DP MCB (10 KA), 16 No 63 Amp FP MCB (10 KA), UPS Outgoing Panel (2 x 30 KVA) described as above

1

-

-

... More
PRESSURIZATION PANEL (TERRACE FLOOR) INCOMING 1 No 100 Amp FP Moulded Case Circuit Breaker (25 KA) 1 No. Digital Multifunction Meter with CT's. 1 Set of phase indicating lamps with Single Pole MCB. 1 Set of ON / OFF indicating lamps with Single Pole MCB. BUS BARS 200 Amp FP aluminium busbar with coloured heat shrinkable sleeve. OUTGOING 8 Nos. 40 Amp FP MCB (10 KA) Pressurization Panel described as above

1

-

-

... More
AC PANEL1,2 & 3 OUT DOOR TYPE (TERRACE FLOOR) INCOMING, 1 No 315 Amp FP Moulded Case Circuit Breaker (25 KA), 1 No. Digital Multifunction Meter with CT's., 1 Set of phase indicating lamps with Single Pole MCB., 1 Set of ON / OFF indicating lamps with Single Pole MCB. BUS BARS, 400 Amp FP aluminium busbar with coloured heat shrinkable sleeve. OUTGOING, 9 Nos. 63 Amp FP RCCB (300mA) , AC Panel Panel described as above

3

-

-

... More
AC PANE-4 OUT DOOR TYPE (TERRACE FLOOR) INCOMING, 1 No 200 Amp FP Moulded Case Circuit Breaker (25 KA), 1 No. Digital Multifunction Meter with CT's., 1 Set of phase indicating lamps with Single Pole MCB., 1 Set of ON / OFF indicating lamps with Single Pole MCB. BUS BARS, 250 Amp FP aluminium busbar with coloured heat shrinkable sleeve, OUTGOING, 6 Nos. 32 Amp FP MCB (10KA), 4 Nos. 40 Amp FP MCB (10KA), 6 Nos. 63 Amp FP MCB (10KA) AC Panel Panel described as above

1

-

-

... More
EXTERNAL LIGHTING PANEL (OUTDOOR TYPE)- Supply, Installation, Testing & Commissioning of fidder pillar type totally enclosed free standing type moisture, dust, vermin & weather proof (IP-55) Floor Distribution Panel made out of 2.0 mm thick & front cover 1.6 mm thick CRCA sheet complete with following equipments, including digital ammeter with inbuilt ammeter selector switch, digital voltmeter with inbuilt voltmeter selector switch, indicating lamps, CT's, internal wiring with suitable size wires / cable, interconnection, painting, MS Stand, RCC foundation etc complete as per specification & drawing. INCOMING 1 No. 63 Amp FP ( 35 KA Ics) Moulded Case Circuit Breaker. 1 No. AVF Meter withinbuilt selector switch & Protective SP MCB. 1 Set of phase indicating lamps with Protective SP MCB. 1 Set of ON / OFF indicating lamps with Protective SP MCB. 1 Set of Electronic KWH Meter with maximum demand recording facility. 1 Set 24 Hrs TSQ Timer 1 Set 63 Amp, FP Contactor & A/M switch and Push Button. BUS BARS 100 Amp FP aluminium busbar. OUTGOING 9 No. 25 Amp DP MCB 2 No. 40 Amp DP MCB. 2 No. 40 Amp TPN MCB. Panel described as above

1

-

-

... More
AIR CONDITIONING (HVAC) EQUIPMENTS HIGH SIDE SUB-HEAD 'A' - AIR CONDITIONING EQUIPMENTS HIGH SIDE (VRV/VRF SIDE) AIR COOLDED VARIABLE REFRIGERANT VOLUME/FLOW AIR CONDITIONING SYSTEM Supply, Installation, testing and commissioning of air cooled Variable Refrigerant Volume/Flow modular type air-conditioning system Invertor Controlled with step less modulation complete with indoor and outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping ,full charge of refrigerant gas & oil, control cabling etc.as per detail given in specifications and having following items: Refrigerant to be used shall be - R - 410 A. OUTDOOR UNIT Supply, Installation, testing and commissioning of Both Cooling & Heating Modular type outdoor units suitable to operate at 415 ± 10 % volt, 50 Hz, 3 phase AC supply and suitable for cooling & Heating application by using 100 % inverter driven capacity control compressors (Hermetically sealed scroll type) with stepless modulation complete with special acryl precoated heat exchanger, minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), low noise condenser fan , auto check function for connection error in display panel, auto address setting as per specifications. The COP at AHRI conditions shall not be less than 3.8 . Complete Set (Indoor and Outdoor) of equipment testing shall be done in the presence of client representative at AHRI Conditions without any extra cost. The units shall be complete with necessary mounting frames and capacity as mentioned below and as per specification. The cost should include the following : Nitrogen pressure testing for refrigerant pipe leakages & flushing during installation & after commissioning between IDU & ODU with flare nuts. Refrigerant gas & oil charging as per OEM standard. Necessary corrosive treatment of copper coil of the ODU with Aluminium hydroxide, 25 microns thickness or equivalent coating as per manufacturer standard to protect from corrosion, sulphur and other chemical contaminants present in the air. The coating should be done in the presence of OEM representative. The coating shall be carried-out by the authorized applicator of coating manufacturer. Note : The ODU provided with cowl duct for exhaust air should have minimum 5 mm ESP. GI wire mesh (minimum 16 SWG thickness) type bird screen with framing at the Mouth of exhaust air Cowl duct of Outdoor Units, where ever required. ODU Units Mounted on MS Frame/Masonry Pedestal with required anti-vibration mounting.

-

-

-

... More
54 HP (3x18 HP)

1

-

-

... More
60 HP (3x20 HP)

2

-

-

... More
64 HP (4x16 HP)

1

-

-

... More
72 HP (4x18 HP)

2

-

-

... More
CEILING MOUNTED 4-WAY/1-WAY CASSETTE UNITS Supply, installation, testing and commissioning of following minimum capacity 1-Way/4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Indoor Units powder coated MS Hanging arrangement/wall Brackets/Spring Isolators with required anti-vibration mounting. 4-Way Cassette Unit

-

-

-

... More
1.5 TR (550 CFM)

1

-

-

... More
2.0 TR (700 CFM)

1

-

-

... More
2.5 TR (800 CFM)

1

-

-

... More
3.0 TR (1050 CFM)

1

-

-

... More
CEILING SUSPENDED DUCTED TYPE UNITS Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pump, drain pan, fire retardant non-porous double layer flexible connection, other necessary supports etc., suitable for operation on single phase AC supply 230 V± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Indoor Units powder coated MS Hanging arrangement/wall Brackets/Spring Isolators with required anti-vibration mounting and Fire Rated Flexible Connection. Mid Static Ductable units (minimum 50 pascal external static pressure) 1.5 TR (525 CFM) Mid Static Ductable units (minimum 100 pascal external static pressure)

4

-

-

... More
2.0 TR (700 CFM)

1

-

-

... More
2.5 TR (900 CFM)

1

-

-

... More
3.0 TR (1200 CFM)

2

-

-

... More
High Static Ductable units (minimum 150 pascal external static pressure)

-

-

-

... More
4.0 TR (1400 CFM)

1

-

-

... More
4.5 TR (1800 CFM)

6

-

-

... More
6.5 TR (2600 CFM)

17

-

-

... More
8.0 TR (3000 CFM)

19

-

-

... More
12.0 TR (4400 CFM)

1

-

-

... More
Refrigerant Joints and Headers Supply, Installation, Testing and Commissioning of copper Y-Joints sets, distributer and headers, suitable for various sizes of gas and liquid line of VRF System complete as required for the above system.

66

-

-

... More
Corded/Cordless Remote Controller Supply, Installation, testing and commissioning of self diagnostic type Corded/Cordless remote controllers for operation of indoor units.

60

-

-

... More
Central Remote Controller Supply, Installation, testing & commissioning of Main intelligent central controller with Scheduled Timer system Touch screen/Gate Way Type suitable for groups of indoor units to operate, monitor, on/off, cyclic operation setting, temperature setting etc. The controller shall be able to control up to minimum nos. of indoor units with zoning option as mentioned below. The controller shall have wide screen user friendly colour LCD Touch screen display and can be wired by a non-polar transmission cable The CRC shall be provided with suitable size metallic box with lock arrangement. The controller shall be integrated to BMS system thru software for monitoring & controlling of all above parameters including start/ stop of each indoor / outdoor unit. All necessary interface cards / units should be supplied as a part of the system to integrate to the BMS Software. Maximum 128 Nos of Indoor Units

1

-

-

... More
Air Cooled Ductable Unit Supplying, installing, testing and commissioning of Air Cooled Ducted Air conditioners suitable for R410A or eco-friendly refrigerant with evaporating unit comprising of cooling coil, blower with motor in Metallic (Steel) casing and condensing unit comprising hermetically sealed scroll compressor, condenser coil, and propeller fan. Unit shall be complete with controls, interconnecting copper refrigerant piping with insulation, Expansion kit to connect with DX AHU, and electrical cabling etc. between evaporative and condensing unit, refrigerant gas and oil and complete as per specifications. The unit shall be suitable for operating on 240 volt, 1 phase, 50 Hz AC supply with five star energy rating. The units shall be suitable for chorded remote operation. The refrigerant piping & cabling shall run in PVC sleeve Steel supporting structure for outdoor units suitable for wall mounting / floor mounting. Providing, fixing and testing of copper refrigerant piping of appropriate sizes duly insulated with nitrile rubber insulation of 19 mm thickness. The pipes plus nitrile rubber insulation and cable are to be covered with PVC flexible conduits for protection. Note: Providing and fixing of Powder coated M.S. angle iron frame work/Masonry Pedestal with required anti-vibration mounting for outdoor unit is also included in the above scope. Contractor to submit design/Scheme for Iron frame and obtain approval of engineer/employer before proceeding purchase & installation. Nitrogen pressure testing for refrigerant pipe leakages & flushing during installation & after commissioning between IDU & ODU with flare nuts. Refrigerant gas & oil charging as per OEM standard. Necessary corrosive treatment of copper coil of the ODU with Aluminium hydroxide, 25 microns thickness or equivalent coating as per manufacturer standard to protect from corrosion, sulphur and other chemical contaminants present in the air. The coating should be done in the presence of OEM representative. The coating shall be carried-out by the authorized applicator of coating manufacturer.

-

-

-

... More
8.5 TR Ductable Split Unit (Only Condensing Unit)

2

-

-

... More
11.0 TR Ductable Split Unit (Only Condensing Unit)

2

-

-

... More
AIR HANDLING UNITS DOUBLE SKIN FLOOR MOUNTED TREATED FRESH AIR UNIT WITH FINE FILTER Supply, Installation, Testing and commissioning of factory built floor mounted Direct Expansion (DX Type) double skin type horizontal/vertical air handling units made of 50±1 mm thick panels consisting of pre plasticized G.I. casing of thickness 1.0mm outside layer and 1.0 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine of density, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/ PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE4 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for variable frequency drive applications, thermal break, drain connections, stainless steel (18G) drain pan with PUF insulation, Fire Rated Flexible Connection, necessary vibration isolation arrangement etc. complete as per specification. The cooling coil made of Aluminium finned Copper tube with coil section, pre-filter section with non woven synthetic media of 10 micron particle size with an efficiency of 90% in both the supply & exhaust side of AHU, fine filter section with filters of non woven synthetic media of 5 micron particle size in supply after fan, mixing chamber complete with motor, belt drive etc. without face and bypass dampers. The AHU mooter and blower shall be acoustically insulated with 25mm thick open cell nitrile rubber with 36 Kg/m³ density and covered with perforated type 0.8 mm MS frame on each sides. The motor & blower assembly shall be mounted on Aluminium extruded section. AHUs shall have air inlet / outlet connection made of aluminium 20 G & all fixing arrangement / blank off shall be of SS, the complete AHU shall conform to standard specification. The face velocity across cooling coil shall be limited to 500 FPM (2.52 MPS) maxim & Fan outlet velocity shall be not exceed 9.0 m/s. Casing shall be of panel construction; double wall type packed with pressure injected CFC free foam insulation minimum 50mm ± 1mm thick. Casing framework shall be of modular galvanized iron, aluminium or Approved equal pentapost double skin construction. Outer skin shall be minimum 1.0 mm galvanized steel sheet while inner skin shall be minimum 1.0 mm galvanized steel sheet. The sheets should have a minimum galvanisation of 275 GSM. The outer skin and inner skin should be precoated or powder coated on the exposed side. The mechanical performance of AHU shall be as per EN 1886. Rating performance for units, components and section shall be as per EN 13053. Fans shall be AMCA certified. Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager. Cost shall be included for suitable rating Starter panel within MS enclosure near the fan with necessary power cabling & connection from Starter panel to fan motor. AHU Filter Shall be Capable of Treating fresh air up to recommended Breathing limit in Delhi NCR of PM 2.5 & PM 10

-

-

-

... More
1,200 CFM (6.0 TR), 65 mm St. Pr.,6 Row CC

2

-

-

... More
1,800 CFM (10.0 TR), 65 mm St. Pr.,6 Row CC

2

-

-

... More
KIT FOR AHUs Supply, Installation, Testing and Commissioning of VRV Kits for AHUs having all controllers & Electronic Expansion Valve (EEV) and temperature set arrangement. It Shall have cut off arrangement after a particular set value of Supply air Temperature.

-

-

-

... More
AHU Kits & Controllers-(Upto-10HP)

2

-

-

... More
AHU Kits & Controllers-(10-20HP)

2

-

-

... More
AIR COOLED DX TYPE SPLIT AC UNITS Supply , installation, testing & Commissioning of ceiling suspended DX type split AC units with air cooled condenser complete with 5 Star Inverter type scroll/rotary compressor ,condenser ,wiring & accessories . Indoor units shall be ceiling suspended/wall mounted type complete with evaporator ,fan, filter ,drier, expansion devices & microprocessor control panel along with all accessories with refrigerant & oil charge , corded remote controls. The unit shall be suitable for working at 240 ± 10% ,50 Hz,1 phase AC supply .The unit shall be designed to take care of minimum vertical head 5mt & horizontal length of 15 mt & necessary oil separator shall be included ,Necessary supporting arrangement for both indoor & outdoor units ( Powder Coated /Epoxy painted MS stand for ODU units as per approved make, shade by Architect) with necessary vibration isolation arrangement as per site condition etc. (without condensate drain pipe ,electrical power & control cabling between indoor & outdoor unit which shall be paid separately ). The coil in the outdoor units shall be provided with anti corrosive treatment. Necessary corrosive treatment of copper coil of the ODU with Bly gold Polu Al (Aluminium hydroxide, 25-microns thickness) to protect from corrosion, sulphur and other chemical contaminants present in the air. Coating should be done in presence of OEM representative. The coating shall be carried-out by the authorized applicator of coating manufacturer. The coil in the outdoor units shall be provided with anti corrosive treatment. Necessary corrosive treatment of copper coil of the ODU with Bly gold Polu Al (Aluminium hydroxide, 25-microns thickness) to protect from corrosion, sulphur and other chemical contaminants present in the air. Coating should be done in presence of OEM representative. The coating shall be carried-out by the authorized applicator of coating manufacturer. The Outdoor unit Compressor must be provided with 5 Year Warranty Period. Silver Ion Filter, Dust FilterCivil Work such as wall hole making , wall chiselling ,refilling of chiselling part with mortar etc. as per site condition. Nitrogen pressure testing for leakages & flushing during installation & after commissioning between IDU & ODU with flare nuts Removable Covers for all indoor & Outdoor units shall be supplied & put on the units after installation & commissioning. Incoming power supply shall be provided near each indoor units 1.5 TR

4

-

-

... More
SCHEDULED TIMER FOR SPLIT AC Supply, installation, testing and commissioning of Scheduled Timer for wall mounted split type Air conditioning units.

2

-

-

... More
AIR PURIFICATION SYSTEM (DUCT MOUNTED) Supply, installation, testing and commissioning of duct mounted Air Purification System with advance oxidation plasma cell (AOP) comprising of UVC lamp 254 NM with nanoX coating metallic compound of five metals targeted on Alumninum matrix cell duly enclosed by a poly quartz casing tube, with the capability to produce ionized Hydroxyl oxidizers with in-built plasmoX to generate ion generator pins (+- ions 10^6) along with ultrasonic radio frequency waves for pest repellancy. The UV-C lamp will be a low-pressure mercury type and of such intensity as to provide minimum performance as listed below. The UV-C lamp will produce only Germicidal UV (by definition this means 99.99% UV-C energy). The airpurifier will have built in LED indication system stating the operation of the 3 technologies the UV lamp, ionizer and pest repellant. The AOP cell shal be capable of removing Particulate matter, Gasous Contamination as well as Microbial Contamination. The power / control cabling between the Pentagon units and the power source / controls shall be included in the cost . The wattage of the lamp shall not be less than 13 watts upto and length not less than 212 MM upto 2000 CFM, 21 watts upto and length not less than 436 MM upto 2000-6500 CFM, 36 watts upto and length not less than 436 MM upto 6501-18000 CFM and a minimum of 48 watts upto 28000 CFM or combination based on the application area. The system shall be capable of reducing microbial bacteria, virus and spores , VoC’, odors and particulates matter. The equipment shall have to CE, ISO 13485, ROHS, TUV, FICCI, GreenPro with 2014/35/EU Low Voltage Directive along with FDA compliance certifications. The AOP cell shall a microbiological testing report against Bacteriophage (MS-2 FDA) surrogate SARS Cov-2 with a minimum efficiency of 99 percent along with a Virology report from ICMR approved lab with an minimum efficiency of 99 percent against SARS COV2 within 45 minutes. The technology shall be tested by ICMR/ IIT on human Alveolar Basal Epithelial Cells stating that there is no change in the structure and prove that it is absoluely safe for humans. The air purfication AOP does not produces ozone, the test certificate from an International Lab shall be produced. The specific certifications shall be submitted along with the technical submital. The failure to submit the certifications along with the submital shall lead to rejection of the product. The AOP cells should be selected by considering a load factor calculation for each specific area where the equipment is to be installed. The Cells Should be complete with Transformers, control cabling and Plug Top & necessary power cable. Vendor to comply all Tender Specifications.

-

-

-

... More
Cassette Type (4-Way)-4Nos.

4

-

-

... More
Duct Type-51 Nos. (350 CFM To 3000 CFM)

51

-

-

... More
Ductable VRV-1Nos (4800 CFM)

1

-

-

... More
DX TFA-1200 & 1800 CFM

4

-

-

... More
VENTILATIONS FANSAXIAL FLOW FANS (SMOKE EXTRACTION/EXHAUST FAN) Supplying, installation, testing and commissioning of AMCA Certified (For Air and Sound Performance) ceiling hung exhaust air tube axial flow fans of following capacity with GSS casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiency class IE3 (as per IS 12615) suitable for 3 Phase 50 Hz 415V ± 10 %, including all accessories complete as required and as per specifications. Motor shall be of high temperature resistance "Class H Smoke Spill" 250° C for 2 hrs. Motor make shall be same as mentioned on the fire certificate. Fan total efficiency should not be less than 70%, noise level should not be more than 78 db. @ 3 m distance when measured in hemispherical reverberant room conditions. All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating. Entire fan model & AMCA Seal shall appear in technical submittal of fan. Air moving capacity shall be as follows: Cost shall be included for suitable rating Starter panel within MS enclosure near the fan with necessary power cabling & connection from Starter panel to fan motor.Fan shall be supplied with Spring Isolators, Fire Rated Flexible Connection, GI gravity louvers, bird screen and fan guard. Note: Contractor Has to take approval on computer generated selection charts and fan curves showing power input and fan motor etc. prior to order the fans,(a) Noise level @ 3m from Fan shall be not more than 78 dB. Back draft Damper : Where required for system design roof-mounted fan shall be equipped with a rattle-free back draft damper to prevent air from re­ entering the fan when fan is not in operation, thus sealing completely in closed position. Damper shall be chatter proof under all conditions.Note:-These fans would be connected to the fire alarm system & BMS system of the building and would start automatically in case of Fire Note 1. Outlet Velocity for normal mode fans not to exceed 10.0 MPS(Meter/Second), 2. Outlet Velocity for Fire mode fans not to exceed 12.0 MPS (Meter/Second), 3. Fan motor shall meet IE3 or above standard as per IS-12615, 4. Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager, 5. Thickness of casing : for dia( 315-630 )mm - 2.5mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm, 6. In case of attenuator , calculation of reduction of sound level with insertion loss of attenuator is to be submitted.

-

-

-

... More
Capacity 4000 CFM, SP 25 mm wg

2

-

-

... More
Capacity 6000 CFM, SP 25 mm wg

1

-

-

... More
Capacity 8000 CFM, SP 25 mm wg

2

-

-

... More
Capacity 10000 CFM, SP 30 mm wg

1

-

-

... More
AXIAL FLOW FANS (SUPPLY/PRESSURISATION FAN) Supplying, installation, testing and commissioning of AMCA Certified (For Air and Sound Performance) ceiling hung Supply/ Pressurisation tube axial flow fans of following capacity with GSS casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor should be of high efficiency class IE3 (as per IS 12615) suitable for 3 Phase 50 Hz 415V ± 10 %, of class 'F' insulation etc. including all accessories complete as required and as per specifications. . Motor make shall be same as mentioned on the fire certificate. Fan total efficiency should not be less than 70%, noise level should not be more than 78 db. @ 3 m distance when measured in hemispherical reverberant room conditions. All the fans shall be hot dip galvanized with minimum 220 GSM Zinc Coating. Entire fan model & AMCA Seal shall appear in technical submittal of fan. Air moving capacity shall be as follows:Cost shall be included for suitable rating Starter panel within MS enclosure near the fan with necessary power cabling & connection from Starter panel to fan motor. Fan shall be supplied with Spring Isolators, Fire Rated Flexible Connection, GI gravity louvers, bird screen and fan guard. Back draft Damper : Where required for system design roof-mounted fan shall be equipped with a rattle-free back draft damper to prevent air from re­ entering the fan when fan is not in operation, thus sealing completely in closed position. Damper shall be chatter proof under all conditions.Note: Contractor Has to take approval on computer generated selection charts and fan curves showing power input and fan motor etc. prior to order the fans,(a) Noise level @ 3m from Fan shall be less than 78 dBA. with starter panel Note:-These fans would be connected to the fire alarm system & BMS System of the building and would start automatically in case of FireNote 1. Outlet Velocity for normal mode fans not to exceed 10.0 MPS(Meter/Second) , 2. Outlet Velocity for Fire mode fans not to exceed 12.0 MPS (Meter/Second) , 3. Fan motor shall meet IE3 or above standard as per IS-12615, 4. Static pressure and Motor Rating : The Indicated static pressure and motor rating is only provisional. Vendor to calculate static pressure based on drawings and pressure drop of finalized Equipment and submit for approval. The procurement shall be processed only after duly approval of calculation and selection from the Project Manager. 5. Thickness of casing : for dia( 315-630 )mm - 2.5mm , dia ( 710-1120)mm - 3mm , dia (1250-1400)mm - 4mm & dia 1600mm - 5mm. 6. In case of attenuator , calculation of reduction of sound level with insertion loss of attenuator is to be submitted.

-

-

-

... More
Capacity 4000 CFM, SP 25 mm wg

2

-

-

... More
Capacity 6000 CFM, SP 25 mm wg

1

-

-

... More
Capacity 8000 CFM, SP 25 mm wg

2

-

-

... More
Capacity 9000 CFM, SP 25 mm wg

3

-

-

... More
Capacity 10000 CFM, SP 25 mm wg

1

-

-

... More
Capacity 14,000 CFM, SP 30 mm wg

2

-

-

... More
INLINE FAN (Ceiling suspended) Supply, installation, testing, commissioning of Single Skin Inline fan with Backward Curved SISW Fan, vibration isolators, speed regulator, GI gravity louvers, Bird Screen and required cable as per specification and drawing. The Motor shall be suitable to run on 1 phase/50 hz/ 220 v electrical power Supply including fire retardant non-porous double layer flexible connection of the following capacity. Thickness of casing : Upto 1000 CFM - 2mm , above 1000 CFM - 3mm, The louvers & bird screen shall be made of 24G & 16G metallic construction respectively.

-

-

-

... More
Upto 200 CFM (340 CMH) at 10 mm static pressure

3

-

-

... More
300 CFM (510 CMH) at 10 mm static pressure

16

-

-

... More
700 CFM (1190 CMH) at 15 mm static pressure

12

-

-

... More
1000 CFM (1700 CMH) at 15 mm static pressure

1

-

-

... More
1600 CFM (2720 CMH) at 15 mm static pressure

1

-

-

... More
PROPELLER FAN: METALLIC TYPE PROPELLER FAN Supply, installation, testing and commissioning of wall mounted Propeller type heavy duty exhaust Fan of metallic construction complete with speed regulator, bird screen, gravity louvers, vibration isolators, required cable, plug & other accessories compete as required, suitable for single phase, 240± 10 volts, 50Hz AC. supply of following capacities:

-

-

-

... More
300 mm sweep dia (900 RPM)

3

-

-

... More
380 mm sweep dia (900 RPM)

1

-

-

... More
450 mm sweep dia (900 RPM)

4

-

-

... More
ABS PLASTIC TYPE PROPELLER FAN Supply, installation, testing & commissioning of Wall mounted Propeller type exhaust air fans of high grade ABS plastic construction complete with electric motor suitable for operation on 230 V+ 10%,50 Hz, 1 phase AC supply fitted with speed regulator, mountings frames, louvers and bird screen, required cable & plug to connect with socket etc. complete as required of following capacities.

-

-

-

... More
200 mm sweep dia (900 RPM)

1

-

-

... More
250 mm sweep dia (900 RPM)

1

-

-

... More
TRANSMISSION & CONTROL WIRING Supplying, installing, testing and commissioning of Shielded control cum transmission wiring of 2 core x 1.5 sqmm copper FRLSH, XLPE insulated cable in suitable GI conduits accessories between indoor and outdoor units. Necessary securing of conduit shall be made by contractor. After completion of work wall and floor shall be repaired and brought to its original finish. The rate will also include cost of laying of GI conduit between indoor and outdoor units. 2C x 1.5 Sq mm (Shielded-Unarmoured)

715

-

-

... More
REFRIGERANT PIPING Supply, fixing, testing and commissioning of interconnecting soft/hard drawn copper refrigerant pipe work of following outer diameter duly insulated with fire rated class'O' closed cell elastomeric nitrile rubber insulation (19mm/13mm thick) between indoor & outdoor units & protected with 26 G aluminium sheet cladding as per specifications. All piping should be laid on Galvanized/Powder Coated tray supported by Galvanized M S Hangers & Clamps and all external piping shall run in covered cable trays. The rate includes all the items required to complete the piping work and nothing extra should be payable except the cable tray. Vaccumiazation & Nitrogen pressure testing for leakages & flushing during installation & after commissioning between IDU & ODU. Civil Work such as wall hole making , wall chiselling ,refilling of chiselling part with mortar etc. as per site condition. Covering of External refrigerant piping insulation shall be done with 26 G aluminium sheet cladding as per specifications. Internal Refrigerant piping insulation shall be covered with Aluminium Foil as per specifications.

-

-

-

... More
6.4 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

14

-

-

... More
9.5 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

371

-

-

... More
12.7 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

88

-

-

... More
15.9 mm outer dia Soft Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

142

-

-

... More
19.1 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

288

-

-

... More
22.2 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

159

-

-

... More
25.4 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

15

-

-

... More
28.6 mm outer dia Hard Drawn with Tube Thickness-1.2mm ( Insulation-19 mm )

29

-

-

... More
31.8 mm outer dia Hard Drawn with Tube Thickness-1.62mm ( Insulation-19 mm )

121

-

-

... More
34.9 mm outer dia Hard Drawn with Tube Thickness-1.62mm ( Insulation-19 mm )

24

-

-

... More
38.1 mm outer dia Hard Drawn with Tube Thickness-1.62mm( Insulation-19 mm )

24

-

-

... More
41.3 mm outer dia Hard Drawn with Tube Thickness-1.62mm( Insulation-19 mm )

101

-

-

... More
44.5 mm outer dia Hard Drawn with Tube Thickness-1.62mm( Insulation-19 mm )

38

-

-

... More
50.8 mm outer dia Hard Drawn with Tube Thickness-1.62mm( Insulation-19 mm )

10

-

-

... More
DRAIN PIPING Providing and fixing of cPVC drain water piping complete with fittings, flexible connection to IDU, necessary support as per specification and insulated with 6 mm thick fire rated class'O' closed cell elastomeric nitrile rubber insulation.

-

-

-

... More
25 mm dia

314

-

-

... More
32 mm dia

293

-

-

... More
40 mm dia

164

-

-

... More
50 mm dia

45

-

-

... More
DUCTING FOR AIR CONDITIONING / VENTILATION FACTORY FABRICATED GALVANIZED SHEET METAL DUCTS (GSS) Supply, installation, testing and commissioning of factory fabricated Galvanized Steel (GSS) Sheet metal ducts complete with flanges, neoprene rubber gasket, elbows, Splitter Damper, vanes, hangers & support etc. as required as per IS/DW144/SAMACNA standard & confirming to specification. Duct shall be furnish at site in "L" shape or box shape from factory. The rates shall include all materials of the duct and labour for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications. Note : Splitter Shall be a part of ducting.

-

-

-

... More
0.63 MM (24 Gauge )

1470

-

-

... More
0.80 MM (22 Gauge )

260

-

-

... More
1.00 MM (20 Gauge )

5

-

-

... More
1.25 MM (18 Gauge)

10

-

-

... More
SITE FABRICATED GALVANIZED SHEET METAL DUCTS (GSS) Supply, Fabrication, installation and testing of Galvanized Steel (GS) sheet metal ducts & finally applying fire rated paint as per BS 476 Part 24 (Site FABRICATED DUCTS For Connection /Plenum etc.) in accordance with the approved shop drawings complete with all accessories like vanes, flanges, suspension rods , anchor bolts, GI bolts & nuts, etc., as per specifications. Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006

-

-

-

... More
0.63 MM (24 Gauge )

134

-

-

... More
0.80 MM (22 Gauge )

15

-

-

... More
1.00 MM (20 Gauge )

10

-

-

... More
1.25 MM (18 Gauge) Plenum

60

-

-

... More
FIRE RATED SHEET METAL DUCT Supply. Installation, testing and commissioning of Fire rated sheet metal ducts with flanges complete with supports, vanes, dampers, links, levers and quadrants etc. as per specifications and drawings. Supporting distance shall not exceed 1.2 Mtr with 6mm thick fire retardant gasket suitable for 250 deg C 2 hr shall be used in duct joints along with fire sealants. The rates shall include all materials of the duct and labour for suspension and supporting arrangement for plenums, ducts, complete with fire retardant flexible connection as required and as per specifications. 1.25 MM (18 Gauge)

75

-

-

... More
Duct Insulation Supplying , installation, testing & commissioning of external thermal insulation on ducts with duly laminated 28G aluminium foil of mat finish Closed Cell Elastomeric Nitrile Rubber Insulation of density not less than 50±5 Kg/m³ & thermal Conductive not exceeding 0.032 W/mK at an average Temperature of 0°C and . The Material Shall be Class O as per BS476 part6 for fire propagation test. The Material shall have Fire Approval from CBRI - Roorkee & no toxicity under flaming and non- flaming condition as per AITM 3.000 (1993). Adhesive used for setting the insulation shall be non - flammable, Vapour Proof. All Joints should be sealed with 3 mm thick 50 mm wide PE tape and Flange to be overlapped by 6" width of the same material thickness. Finally Duct insulated should be strapped by 12mm metallic Packing strip at every random meter & conforming to standard and Specification. All Ducts insulated internally on oval shaped and externally insulated on rectangular ducts.

-

-

-

... More
9 mm (Return Duct)

31

-

-

... More
13 mm (Supply Duct)

1131

-

-

... More
19 mm (TFA Duct)

98

-

-

... More
ACCOUSTIC LINING AHU ROOM ACCOUSTIC LINING Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg/cu.m resin bonded glass fiber insulation friction fixed in 610mm x 610 mm frame work made of 25X50X50X50X25 mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications. 50 mm thick

1

-

-

... More
Duct Acoustic Lining Supply and fixing of acoustic lining of supply air duct and plenum with thick Engineered Nitrile Rubber open cell foam having a Noise Reduction Coefficient of 0.55 with Density 160 Kg/m3 passing Class 1 Fire Performance test as per BS 476 Part 7, Air Erosion test for 10,000 fpm air velocity as per ASTM C 1071-05 and with built-in antimicrobial protection. The material should pass Fungi Resistance Test as per DIN EN ISO 846 Method A and Bacterial Resistance Test as per DIN EN ISO 846 Method C; to be applied using manufacturer's recommended Rubber based Adhesive in a blend of solvents. protected with 26 G aluminium sheet cladding as per specifications.

-

-

-

... More
20 mm For Duct

220

-

-

... More
25 mm For Plenum

70

-

-

... More
CONTROL DAMPER VOLUME CONTROL DAMPER Supply,. Installation, testing and commissioning of 18 Gauge G.I construction Frame with 22/24 Gauge GI Aero foil blades Volume control Duct/Wall Dampers with linkages, levers & fittings for Controlling the Airflow in Ducts with neoprene rubber gaskets,nuts, Bolts, Screws Linkages, Flanges etc. as per specification.

8

-

-

... More
AIR TERMINAL (SUPPLY/RETURN/EXHAUST) Supply, installation, testing and commissioning of 50 micron Powder coated Aluminium extruded Air Terminal (Diffuser/Grille) as per specification & and drawings including fixing frames of GI in False ceiling/wall. Grilles Supply. Installation, testing and commissioning of powder coated extruded aluminium section grills with aluminium dampers for supply air terminal and grilles without damper for return air for air-conditioning as per specification.

-

-

-

... More
Grilles with Dampers

30

-

-

... More
Grilles without Dampers

26

-

-

... More
Diffusers Supply. Installation, testing and commissioning of powder coated extruded aluminium square diffusers with antismudge ring and removable core.

-

-

-

... More
Supply air with dampers

5

-

-

... More
Return air without damper

1

-

-

... More
Flexible Duct Supply. Installation, testing and commissioning of thermal flexible aluminium duct of following sizes duly supported at regular interval as per site requirement & speciation's. 200 mm

50

-

-

... More
Slot Diffusers Supply. Installation, testing and commissioning of slot diffusers with/without damper as specified below and as per specification.

-

-

-

... More
3-Slot Diffuser

1

-

-

... More
2-Slot Diffuser

1

-

-

... More
Linear Grille Supply. Installation, testing and commissioning of powder coated extruded aluminium Linear Grille.

-

-

-

... More
100 mm

1

-

-

... More
150 mm

30

-

-

... More
200 mm

1

-

-

... More
Air Transfer Door Grille Supply and fixing of non vision air transfer door grille of powder coated extruded aluminium, single deflection grille with horizontal vanes arrangement etc. as per specifications and drawings.

10

-

-

... More
Exhaust/Fresh Air Louvers Supply, Installation, Testing and Commissioning of Fresh Air/Exhaust air Louvers minimum 80 mm deep comprising of inclined blade and extended-out lowest blade for disposal of rain water including the wire mesh, filter (washable type filter section Class-G3 having efficiency 80% down to 20 micron fitted in aluminium frame) . The louver shall be of extruded Aluminium construction, and powder coated to the approved finish and colour.

5

-

-

... More
FIRE DAMPER Motorized Fire Dampers With Actuator Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Duct/Wall mounted multi blade, motorised fire & smoke dampers with spring return actuator. The damper shall be of at least 1.5 hr. fire rating and actuated with the help of 24 V electric actuator excluding. The damper shall be as per UL listed UL 555; 1995 and CBRI approved. The damper shall be constructed out of 16G galvanised steel sheet & as per specification with Control Cable to Potential Free Contact for tripping of AHU fan motor. Supply, installation, testing and commissioning of Motorised Spring Return Actuator for devices up to 0.8 sq. meter with control panel & temperature sensor.

-

-

-

... More
Fire Damper

2

-

-

... More
Actuator

4

-

-

... More
SUB-HEAD 'F' -ELECTRICAL WORKS ISOLATOR FOR OUTDOOR UNIT Supply, Installation, Testing & Commissioning of following Switchgears as an Isolator in IP-65 rated in power coated 16 SWG sheet steel enclosure .

-

-

-

... More
32A 4P MCCB(25 KA) Upto 10.0HP

4

-

-

... More
40A 4P MCCB(25 KA) 10.1 to 14.0HP

2

-

-

... More
63A 4P MCCB(25 KA) 14.1 HP To 22.0 HP

21

-

-

... More
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. Supply and laying ,testing and commissioning of following sizes of Copper conductor control cables with PVC conduit & fixing clamps and effecting proper connections to equipment etc. of following sizes :

-

-

-

... More
4C x 16 Sq. mm Copper Conductor (Armoured) 14.1 HP To 22.0 HP

140

-

-

... More
4C x 10 Sq. mm Copper Conductor (Armoured) 10.1 to 14.0HP

22

-

-

... More
4C x 6 Sq. mm Copper Conductor (Armoured) Upto 10.0HP

36

-

-

... More
4C x 4 Sq. mm Copper Conductor (Armoured) For AHU

48

-

-

... More
GI COVERED CABLE TRAY Supplying and installation for following size of perforated Hot Dipped Galvanised Iron Covered cable tray With Bends, Tee, Cross Member & Reducer (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
150 mm wide x 50 mm depth x 1.6 mm thickness.

25

-

-

... More
300 mm wide x 50 mm depth x 1.6 mm thickness.

32

-

-

... More
450 mm wide x 50 mm depth x 2.0 mm thickness.

45

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.