Pey Jal Nigam Uttarakhand Tender

View complete overview of Uttarakhand Pey Jal Nigam Uttarakhand Tender

Pey Jal Nigam Uttarakhand Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Dec 2024
Closing Soon26 Dec 2024
Tender Amount₹ 3,91,89,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
DSR 7.1.4 Above 185 sq. mm and upto 400 sq. mm

50

-

-

... More
DSR 14.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.

-

-

-

... More
DSR 14.16.1 63 mm dia (OD-63 mm & ID-51 mm nominal)

500

-

-

... More
DSR 14.16.2 90 mm dia (OD-90 mm & ID-76 mm nominal)

400

-

-

... More
DSR 14.16.4 160 mm dia (OD-160 mm & ID-135 mm nominal)

150

-

-

... More
DSR 5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

500

-

-

... More
NS Design, Supply, Handling/Shifting, Stress fitting and Assembly, Installation, Testing and Commissioning of Fixed Head type High Mast as detailed below:

-

-

-

... More
Supply of Fixed Head type High Mast for stadium lighting application, complete with all accessories and as detailed below.

12

-

-

... More
Design Considerations and Construction Features: Total height of assembled High Mast, from bottom of flange to the top of head frame shall be as per proposed lighting simulation, meeting the Illumination and Glare requirements as per relevant standards, subject to a minimum height of 14mtrs. Constructional and dimensional parameters of High Mast structure shall be decided to meet the structural loading requirements corresponding to the wind speed specified in IS 875 (Part Ill) for Dehradun, with standard safety factors and a design life of 25 years. Polygonal mast structure shall be manufactured from HT grade steel with not more than one longitudinal welding per section and without any circumferential welding, except for the flanges. The structure, Head frame and all accessories, as applicable, shall be hot dip galvanized to achieved minimum average coating thickness through single dip process. Suitable fixed type head frame shall be provided with appropriate number of cross arms, approach ladders and maintenance platform. The mast shall be provided with appropriate lightening arrestor, necessary hardware and attachments and should have suitable provision to installed aviation lights at the top with mounting accessories,equipped with photocell for automatic switching. Design, Construction and Material of the High Mast shall conform to applicable standards/norms and its design/structural stability calculations. Appropriate arrangement for mounting MCBs for floodlights and to receive incoming supply cable from Feeder Pillar, etc. shall be provided inside the door of each High Masts. Supply of MCBs is included in the scope.

-

-

-

... More
NS Supply and Fixing of Foundation Bolt Accessories comprising of bolts, nuts, washers, anchor plate and template. Size and number of bolts, anchor plate, etc. as per manufacturer's design, The exposed threaded portion of bolts, complete nuts and washers shall be hot-dip galvanized.

12

-

-

... More
NS Unloading, Handling/Shifting, Stress fitting, Assembly, Installation on existing foundation, Testing and Commissioning of Fixed Head type High Masts, as above. The scope includes provision of necessary T&P, lifting crane/hydra, etc. adhering to prudent pracices and following all safety requirements.

12

-

-

... More
NS Disassembly of existing sports mast poles includes the safe removal of all components, such as lights and electrical systems, along with the disassembly of the mast structure

6

-

-

... More
NS Construction of RCC Foundation for the above High Masts as per manufacturer's recommendation and design, considering site conditions and complete with all material, labour, consumables and T&P.

12

-

-

... More
NS Supply, Installation on above High Masts and roof, Tesing and Commissioning of LED Floodlight luminaire with a housing of non-corrosive high pressure ADC with corrosion resistant powder coating and Anti-dust exposed Lens to ensure protection. The luminaire should have CRI 70, SDCM 5 and CCT of nominal 5700K and shall be compliant with IP66 and IK08 classification. Luminaire shall be of minimum system wattage of 450W at a system efficacy of atleast 125 lumen/watt. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 35 deg C. The luminaire should have fins on the back to ensure good heat dissipation and to prevent dirt from settling on the luminaire along with aiming angle scale. The electronic driver should be fully integrated and shall have a power factor 0.95 and THD 10% with a minimum inbuilt surge protection of 4kV/kA internal & 20Kv enternal and suitable for an operationg voltage range of 140-270V AC.

300

-

-

... More
NS Providing Chemical Earthing for High Masts and Feeder Pillars as per site soil conditions, following prudent practices, complete with requisite material, labour and chamber.

34

-

-

... More
NS SITC of Outdoor Type, Double Door Feeder Pillar with minimum 2mm thk (for straucture) and 1.6mm thk (for doors, etc.) MS sheet duly pretreted with 7-Tank process, powder coated of specified shade and provided with Sloping Canopy for installation on base frame. Suitable size of TPN Aluminium Bus Bar, Earth Bar, Padlocking arrangement, Detachable Gland Plate with all standard accessories shall be provided. The Feeder Pillar shall be deigned to accommodate following MCCBs, MCBs and Interconnection, etc. as reqd - 1 no. Incomer of 100 A, 16KA, FP MCCB c/w ON/OFF and R/Y/B LED indicating lamps, 3 nos. outgoings of 63 amps FP MCB Isolator and requsite nos. of MCBs.

4

-

-

... More
NS Design, Fabrication, Supply, Installation of painted MS structure of appropriate size/design on the building wall for mounting of requisite quantity of Floodlights and allied accessories as per the lighting design. The scope of this work includes provision of necessary material/accessories, such as, fixing/grouting hardware, clamps/arrangement for fixing electrical wiring and LILO boxes for providing electrical power supply to the floodlights.

1

-

-

... More
NS Supply of following size XLPE aluminium armoured cable

-

-

-

... More
4 c x 25 sq.mm

500

-

-

... More
3.5 c x 70 sq.mm

400

-

-

... More
3.5 c x 240 sq.mm

150

-

-

... More
NS Supply and laying/fixing of following size XLPE unarmoured copper cable

-

-

-

... More
3 c x 2.5 sq.mm

5200

-

-

... More
NS Supply, installation, testing and commissioning of outdoor type, IP 55, double door with canopy, cubicle type Main Power Supply Panel suitable for 415 volt, 3 phase, 4 wire, 50 HZ AC supply system. The panel shall be fabricated out of CRCA steel of 2 mm thick for frame work, 1.6mm for the doors/covers, 3 mm thick for gland plates and of compartmentalized design. It shall be provided with TPN aluminium alloy bus bar of high conductivity, with base frame of M.S. section of suitable size, aluminium earth bar of size 25mmx 5mm at the rear with 2 nos earth stud, complete with FRLS copper control wiring, cable alleys, cable gland plates, including the items mentioned below. The panel should be suitable for Pedestal mounting, 500mm above ground level with necessary base frame. Incoming Power Supply Section : The incoming power section shall comprise of the following; 2 Nos. 400A, FP MCCB (36kA) with thermo-magnetic releases and other accessories, such as, spreader link set, rotary handle, etc. as Incomers. These MCCBs shall be mechanically interlocked to ensure that only one Incomer is ON as any stage.

-

-

-

... More
Each incoming MCCB feeder shall be equipped with the following items;  1 Set of LED indicating lamps for phase indication (R, Y, B)  1 No. 0 to 500V AC, Volt Meter with VSS & control fuses.  1 No. 0 to 300A, Ammeter with ASS & CTs of ratio 250/5A, cast resin type with class-1 accuracy.  Digital Multifunction Meter, three phase with RS-485 Port, Cl-1.0, 96 x 96 sqmm.  Other accessories, such as, control MCB SP 6A, 10KA, CT Terminal Disconnected Type, Neutral Link, etc. Note: The incoming feeders shall be designed to receive 1100V grade, LT, aluminium armoured power cable of specified size. The outgoing supply section shall comprise of the following; 6 Nos. 100A, FP MCCB (25kA) with thermo-magnetic releases and other accessories, such as, spreader link set, rotary handle, etc. as Incomers. Each outcoming MCCB feeder shall be equipped with 1 set of LED indicating lamps for phase indication (R, Y, B) and 1 set of LED indicating lamps of showing ON/OFF status of the feeder. Other accessories, such as, control MCB SP 6A, 10KA, Neutral Link, etc. shall be provided, as required. Note: The outgoing feeders shall be designed to receive 1100V grade, LT, aluminium armoured power cable of specified size.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.