Pey Jal Nigam Uttarakhand Tender

View complete overview of Uttarakhand Pey Jal Nigam Uttarakhand Tender

Pey Jal Nigam Uttarakhand Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date7 Feb 2024
Closing DateCancelled
Tender Amount₹ 7,42,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil

3345

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

668.91

-

-

... More
Diluting and injecting chemical emulsion (chlorpyriphos/Lindane E.C 20% with 1% concentration) at the rate of one litre per hole at 300 mm c/c to all the horizontal and vertical surface of the excavation made for the foundation of the building, soil under floor,apron, back fill material and along all the faces of the walls for PRE-CONSTRUCTIONAL anti-termite treatment (including the cost of chemical emulsion) as per IS:6313 Part-II. (Plinth area of building shall be measurd for payment.)

604.59

-

-

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

54.33

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

66.22

-

-

... More
M-10 grade plain cement concrete (cement content considered @ 220 kg/cum)

22.16

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :) 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

12.84

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level

229.39

-

-

... More
All works above plinth level upto floor V level

924.12

-

-

... More
Add for using extra cement in the items of design mix over and above the specified cement content therein.

424.93

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more

1015.84

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

512.1

-

-

... More
Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc

855.36

-

-

... More
Suspended floors, roofs, landings, balconies and access platform.

42.6

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

984.5

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

627.52

-

-

... More
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick

1324.19

-

-

... More
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).

9.82

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)

380.36

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:

31.9

-

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)

440.51

-

-

... More
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)

3466.98

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)

1770.48

-

-

... More
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand)

86.1

-

-

... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)

829.11

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate

40

-

-

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick

71.84

-

-

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

545.5

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.

25.43

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Marble work

28.89

-

-

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

23

-

-

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per SQM, including pointing in white cement mixed with pigment of matching shade

226.3

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ SQM including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm

1115.32

-

-

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/SQM mixed with water proofing cement compound @ 0.253 kg/ SQM. This layer will be allowed to air cure for 4 hours (b) Second layer of slurry of cement @ 0.242 kg/SQM mixed with water proofing cement compound @ 0.126 kg/SQM. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

134.4

-

-

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 10.14.1 Profile B10.14.1.1 Fixing with adjustable lugs with split end tail to each jamb

460.85

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

166.31

-

-

... More
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides

21.92

-

-

... More
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).

166.31

-

-

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes

166.31

-

-

... More
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90 mm

356

-

-

... More
Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete :150 mm

68

-

-

... More
Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete.

62

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete..

4296.09

-

-

... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. New work ( two or more coats) over and including priming Coat with cement primer complete.

4296.09

-

-

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 SQM) over and including priming coat of exterior primer applied @ 2.20kg/10 SQM

1712.88

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

513.42

-

-

... More
Steel work welded in built-up sections / framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.

2993.49

-

-

... More
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size)

438.3

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

111005.1

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per SQM as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

740.03

-

-

... More
Steel work welded in built-up sections / framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.

1485.39

-

-

... More
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete

7.14

-

-

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work

22.05

-

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover

32.03

-

-

... More
Providing and fixing ball bearing for rolling shutters.

8

-

-

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.

2351.42

-

-

... More
Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).

715.34

-

-

... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30

352.71

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)

235.14

-

-

... More
Sepration Membrane of Impermeable Plastic Sheeting 125micron Thick

1541.48

-

-

... More
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/expansion, construction & longitudinal joints (10 mm wide x 50 mmdeep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine

319.02

-

-

... More
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)

1027.65

-

-

... More
Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade 'A' sealing compound conforming to IS: 1834.

1027.65

-

-

... More
Painting road surface marking with adequate nos of coats to give uniform finish with ready mixed road marking paint conforming to IS : 164, on bituminous surface in white/yellow shade, including cleaning the surface of all dirt, scales, oil, grease and foreign material etc. complete. New work (Two or more coats)

30.9

-

-

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

224.63

-

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

173.42

-

-

... More
Landscapping & horticulture work As per CPWD

758.74

-

-

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.

60.21

-

-

... More
Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work.

7089.77

-

-

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.

-

-

-

... More
In cement mortar

141.3

-

-

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.

-

-

-

... More
For thickness of tiles 10 mm to 25 mm

239.09

-

-

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :

-

-

-

... More
Of area 3 sq. metres and below

18

-

-

... More
Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead.

2

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.

150

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit, 2 way modular switch, modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.( Lift well )

4

-

-

... More
Wiring for group controlled (looped) light point / fan point / exhaust fan point/ call bell point (without independent switch etc.) with1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.-group-C

150

-

-

... More
Wiring for circuit wiring alongwith earth wire with the following sizes of HR-FR-LSH-lead free copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

500

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulatedcopper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

1800

-

-

... More
Wiring for power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copperconductor single core cable for loop earthing as required. (FOR POWER PLUG )

2130

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.

-

-

-

... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire for floor panel to L- DB

1000

-

-

... More
4 X 16 sq. mm + 2 X 6 sq. mm earth wire for floor panel to P-DB

800

-

-

... More
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc as required.

60

-

-

... More
Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 16 Amp universal modular socket outlet and 15/16 amps modular switch,connection, painting etc as required.

51

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

55

-

-

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

55

-

-

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.

20

-

-

... More
Supplying and fixing of Following sizes of PVC conduit along with the accessories like Junction boxes, bends, socket, fish wire etc. on surface/recess with M.S. Clamps, nuts and bolts including cutting of the wall and making good the same in case of recessed conduit as required. for LV

-

-

-

... More
20mm

800

-

-

... More
25mm

1200

-

-

... More
32mm

500

-

-

... More
40mm

300

-

-

... More
Supply, fixing, connecting and testing of telephone / computer / TV modular sockets modular plate anodised MS box and blanking plate in surface / recessed including connectionetc as required.

-

-

-

... More
RJ-11 telephone socket two line with shutter

14

-

-

... More
Data -I/O (RJ-45 Connectors) + Dats Face Plate

10

-

-

... More
TV antenna socket outlet

2

-

-

... More
Supplying and drawing following pair, 0.5 sq.mm. FR PVC insulated copper conductor, unarmoured telephone cable in existing surface/ recessed steel/ PVC conduit as required.

-

-

-

... More
2 pair Telephone cable ( 0.5 sq.mm. )

420

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.

-

-

-

... More
1 run of cable

300

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

100

-

-

... More
Supplying and fixing following way,horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator)

-

-

-

... More
6 way (4 + 18), Double door

2

-

-

... More
8 way (4 + 24), Double door L-DB + P DB+U DB

10

-

-

... More
Supplying and fixing upto following amps rating, 240/415 volts, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required.

-

-

-

... More
6-32 Amp (10KA) SP MCB 'C' Series

204

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB),having a sensitivity current upto 100 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
63 Amp SPN RCCB with 100 ma fault current rating

30

-

-

... More
40 Amp SPN RCCB with100 ma fault current rating

6

-

-

... More
Supplying and fixing upto following amps rating, 240/415 volts, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required.

-

-

-

... More
63A FP MCB

18

-

-

... More
40A FP MCB

10

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) MCCB incomer

-

-

-

... More
8 way (4 + 24), Double door

2

-

-

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
100 A, 16 KA,TPMCCB

2

-

-

... More
Supply of lighting fixtures of surface mounted 15W LED Round Downlighter luminaire. The LED source used shall be complying with LM80 standards & LED source efficacy 150 lm/w. Epoxy white powder coated die cast aluminium housing; Efficient PMMA front visor;. The system lumen output of the luminaire of a minimum of 100 lms/W with color temprature of 5700 deg K (ANSI Bin) and CRI80. Integral Driver with constant current constant voltage (CVCC), P.F 0.95, THD10% and Surge Protection of atleast 3.5KV.

130

-

-

... More
Supply of lighting fixtures of surface mounted 12W LED Round Downlighter luminaire. The LED source used shall be complying with LM80 standards & LED source efficacy 150 lm/w. Epoxy white powder coated die cast aluminium housing; Efficient PMMA front visor;. The system lumen output of the luminaire of a minimum of 100 lms/W with color temprature of 5700 deg K (ANSI Bin) and CRI80. Integral Driver with constant current constant voltage (CVCC), P.F 0.95, THD10% and Surge Protection of atleast 3.5KV.

132

-

-

... More
Supply of lighting fixtures of surface mounted 10W LED Round Downlighter luminaire. The LED source used shall be complying with LM80 standards & LED source efficacy 150 lm/w. Epoxy white powder coated die cast aluminium housing; Efficient PMMA front visor;. The system lumen output of the luminaire of a minimum of 100 lms/W with color temprature of 5700 deg K (ANSI Bin) and CRI80. Integral Driver with constant current constant voltage (CVCC), P.F 0.95, THD10% and Surge Protection of atleast 3.5KV.

12

-

-

... More
20 W linear 4ft LED integrated batten made of ultra slim co-extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.White finish ABS end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. These end caps are snap-fitted to the fixture.High efficiency long life LED with lumen efficacy of 130 lm/W with viewing angle of 120º.Powered by an integral isolated low THD electronic LED driver ( SMPS based constant current supply) with output short circuit protection, surge protection.Can be fixed directly into the wall/ ceiling by means of mounting SS clips provided with the fixture. Lumen Output of 2110 lumens with System efficacy of 105lm/W .CRI 80, Color temperature 6500K, THD 20% and PF0.95,IP20 . Life class of 35,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ.

9

-

-

... More
Supply of 10W LED BulK head Fitting, The LED source used shall be complying with LM80 standards & LED source efficacy 120 lm/w. Epoxy white powder coated die cast aluminium housing; Efficient PMMA front visor;. The system lumen output of the luminaire of a minimum of 100 lms/W system efficacy with color temprature of 5700 deg K (ANSI Bin) and CRI80. Integral Driver with constant current constant voltage (CVCC), P.F 0.9, THD20%,IP65 and Surge Protection of atleast 5KV.

20

-

-

... More
Supply of following Ceiling Fan :

-

-

-

... More
1200mm Sweep similar to Havells CAT no. - samart /RR Kabil

55

-

-

... More
Supplying of Heavy Duty Exhaust Fans

-

-

-

... More
300 mm, 1400 RPM

6

-

-

... More
Installation, testing and commissioning of pre-wired,fluorescent fitting / compact fluorescent fitting/ LED Light fitting of all types,complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required.

303

-

-

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.

151.5

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

55

-

-

... More
FIXING EXHAUST FAN UPTO 450 MM SWEEP

-

-

-

... More
Installation, testing and commissioning of exhaust fan up to 450 mm sweep in the existing opening,including making the hole to suit the size of the above fan, making good the damage complete , connection , etc as required.-M/C ROOM & PUMP ROOM

6

-

-

... More
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.

6

-

-

... More
Supply of UL approved low carbon high tensile steel rod with copper coating of min 254 micron JK Chemrode - 0110 CBR the dia should be 25 mm with length of 10 feet ( 3000 mm) . The rod shall be as per IEC 62561-2 and approved by UL 467. The rod shall be tested from NABL lab for current discharge not less then 46kA peak. The Chemrode shall be surrounded with 25 kg ( 1 bag) of Earth enhance materiel JK Reslow according to IEC 62561-7 and the Chemical resistance value shall not increase more then 0.067 Ωm and same will be tested from NABL lab. along with earth pit chamber made up polyplastic. Size of -254x330x260 MM (Model similar to PPC01)

25

-

-

... More
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

400

-

-

... More
Supply and Installation 25 mm x 5mm G.I. strip on surface or in recess for connection etc as required.

750

-

-

... More
Supply and Installation 6 SWG G.I. wire on surface or in recess for loop earthing as required.

1200

-

-

... More
SITC of Vertical Electrolytic Copper Lighting Arrester of 16 mm dia, 1000 mm long with Gun Metal base plate . Model similar to APSAT116C+APSTB16-253

8

-

-

... More
SITC 8 mm round aluminium conductor for horizontal lightning protection - run in roof. Model similar to AL8.

75

-

-

... More
SITC of roof conductor holder for 8 mm round aluminium conductor made of Gun Metal for horizontal installation. The distance between each holder should be min of 1 mtr. Model similar to APSRCS50.

40

-

-

... More
SITC of T connector for connecting of 8 mm Al round conductor . The connector should be of Gun Metal with SS nuts and bolt. Model similar to APSTCRC50

20

-

-

... More
SITC of Cross connector for connecting of 8 mm Al round conductor . The connector should be of Gun Metal with SS nuts and bolt. Model similar to APSCCRC50

20

-

-

... More
SITC of straight connector for connecting of 8 mm Al round conductor . The connector should be of Gun Metal with SS nuts and bolt. Model similar to APSPCRC50

8

-

-

... More
SITC of Expansion piece to compensate the expansion of round 8 mm Al conductor when temperature variation . Connection should be in every 20 mtr. Model similar to APSEXP50

8

-

-

... More
EXPANSION PIECE CONNECTOR-

20

-

-

... More
SITC of 8 mm round aluminium conductor as a down conductor mounted in the surface of wall which will carry the lightning current to earth pit. Model similar to AL8.

8

-

-

... More
SITC of Down conductor holder for 8 mm round aluminium conductor of min distance between the wall to the conductor will be of 85 mm. The distance between each holder should be min of 1 mtr. Model similar to APSRCS50

8

-

-

... More
Supply and installation of Test Clamp to disconnect the down conductor from the earth termination network for regular checks of the earth termination resistance value.

4

-

-

... More
SITC of 6 digit lightning strike counter. Model similar to LEC06

1

-

-

... More
Supplying and laying 25 mm x 5mm G.I. strip on surface or in recess for connection etc as required.

20

-

-

... More
Providing and laying of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required.

50

-

-

... More
Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card,minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.

-

-

-

... More
Two Loop Panel.

1

-

-

... More
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.

34

-

-

... More
Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required.

2

-

-

... More
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED,metallic cover complete with all connections etc as required.

24

-

-

... More
Supplying, installation, testing & commissioning of fault isolator complete with base as required.

5

-

-

... More
Supplying, installation, testing & commissioning of addressable fire control module complete as required.

10

-

-

... More
Supplying, installation, testing & commissioning of addressable manual call point complete as required.

3

-

-

... More
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.

3

-

-

... More
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.

1

-

-

... More
Supplying, installation, testing & commissioning of 6W ceiling speaker complete as required.

10

-

-

... More
Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required.

1

-

-

... More
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.

1

-

-

... More
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.

820

-

-

... More
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Single pair, 2-core, 1.5 sqmm

800

-

-

... More
1 No.3 phase 50 Hz 200 kVA, 11KV /415V, DYn11, core type double wound with copper conductor oil immersed ONAN cooled Distribution Transformer OFF Circuit Tap Changer voltage ratio of 11 KV / 415V with HT & LT Cable Box. Tappings +5% to –10% in steps of 1.5% shall be provided at line end of HV winding. .Losses are as per IS -1180 Level 1 (New Ammendment))

-

-

-

... More
Capacity 200 KVA

-

-

-

... More
Input terminals suitable for connecting 11KV XLPE aluminium conductor armoured cable enclosed in a cable box.

-

-

-

... More
Output terminals suitable for connecting 1.1 KV grade single core aluminium conductor cable enclosed in a cable Box.

-

-

-

... More
L.T. Aux. terminals connections - suitable for 1.1 KV grade PVC /XLPE cable on Transformer Part

-

-

-

... More
H.T.Aux. terminals – suitable for 11 KV grade XLPE Al. Cable on Transformer Part

-

-

-

... More
Output : 415 V +/- 1% , 3 phase 50 Hz ,Unbalanced load

-

-

-

... More
Winding temperature indicator with alarm and trip Contacts

-

-

-

... More
Pressure release valve / explosion vent to be provided on ther top of the tank.

-

-

-

... More
Silica gel breather

-

-

-

... More
Oil Temp. Indicator with alarm & trip Contacts

-

-

-

... More
Total carried over to summary

-

-

-

... More
Medium Voltage Panel

-

-

-

... More
NOTE: ALL ACBs ARE REQUIRED WITH SAFETY SHUTTER, UNDER VOLTAGE RELEASE / SHUNT TRIP

-

-

-

... More
General Note for all Panels

-

-

-

... More
The Panels/ Switch-boards shall be fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) CRCA sheet steel, Compartmentised design, modular construction with Form 4b separation for Main Panels & 3b for remaining, Mounting Plates and Internal Partition shall be made of 1.6/2.0mm Aluzinc sheet for better heat dessipation clear space of 300mm or as approved shall be left at the bottom.The operating handle of the topmost switch shall not be higher than 1800mm from the finished floor and maximum height of panels shall not more than 2400mm.The Panel shall be Powder coated to paint of desired shadend in an approved manner.

-

-

-

... More
Undervoltage Relay (27)

-

-

-

... More
Reverse power RELAY (32)

-

-

-

... More
Inverse Definite minimum time overcurrent relay

-

-

-

... More
Overvoltage Relay (59)

-

-

-

... More
Trip Circuit Supervision Relay

-

-

-

... More
Master Trip Relay

-

-

-

... More
Bucholz protection (only transformer switch ) (63)

-

-

-

... More
Emergency stop on each panel

-

-

-

... More
All incomers and Bus coupler panel door should be different colour coded for identification and mimic diagram in front of panel should be marks by reflector paints

-

-

-

... More
All ACB terminals shall have vertical-vertical configuration for termination of incoming & outgoing bus links. All MCCB’s up to 630A shall be provided with rear stud type terminations.

-

-

-

... More
Space heater, Thermostat, On/Off switch, LED Lamp , Door operated switch.

-

-

-

... More
All ACBs shall have protection Releases with LSIG.

-

-

-

... More
All Multifunction meters shall communication on ethernet through ethernet ports and shall have % THD and individual harmonics till 15 order

-

-

-

... More
Mimic Diagram compulsary

-

-

-

... More
Supply, Erection, Testing and commissioning of Indoor type ( IP 54 Protection ) cubicle pattern LT Switch-Board with a rupturing capacity of 50 KA at 415 V for 1 sec or as called for in individual items, openable in front and back suitable for 3 phase, 4 wire, 50Hz AC supply at an ambient temperature of 45 C. The cubicle should be well ventilated and enclosure protection shall be IP-54 as per IS 2147-1962.or as per CPWD specifications, ( Part IV - Sub-station) and IS: 8623 , fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) CRCA sheet steel in Compartmentised design, modular construction with Form 4b separation for Main Panels & 3b for remaining, Mounting Plates and all Internal Partition shall be made of 1.6/2.0mm Aluzinc sheet for better heat dessipation. The cubicle should be front operated, floor mounted, free standing with compartments in tier formation, extensible on both sides.The panel to be provided with PVC Sleeved 4 pole Electrolytic Al .Maximum Current density for the bus bars shall meet temp rise condition. Bus Bar and PVC insulated solid interconnections and also provided with 50x6mm. horizontal AL Earth Bus Bars in each section.(as per drawing- enclosed-Main LT Panel). Panel should be extensible type.

-

-

-

... More
INCOMER:- (FROM 200KVA TRANSFORMER)

-

-

-

... More
1 Nos 320A FP MCCB 35kA With Microprocessor Based Release (O/C,S/C,E/F) Protection & all Accessories in each :

-

-

-

... More
1 No. 320A FP Contactor

-

-

-

... More
1 No Under Voltage Relay (27)

-

-

-

... More
1 No Over Voltage Relay (59)

-

-

-

... More
1 No. Multifunction Meter With RS-485 port

-

-

-

... More
1 set C.T's 320/5Amp , CL 1.0, 15VA for meter

-

-

-

... More
1 set C.T's 320/5Amp , CL 1.0, 15VA for APFCR

-

-

-

... More
1 No A/M Selector switch

-

-

-

... More
1 set Phase Indicating LED Lamps with backup MCB

-

-

-

... More
1 ses ON,OFF,TRIP indicating LED Lamps with backup MCB.

-

-

-

... More
Control SP MCB

-

-

-

... More
1 no emergency stop push button switch (to control whole panel)

-

-

-

... More
INCOMER:- (FROM 200KVA DG) x1. for each :

-

-

-

... More
1 Nos 320A FP MCCB 35kA With Microprocessor Based Release (O/C,S/C,E/F) Protection & all Accessories in each :

-

-

-

... More
1 No. 320A FP Contactor

-

-

-

... More
1 No Under Voltage Relay (27)

-

-

-

... More
1 No Over Voltage Relay (59)

-

-

-

... More
1 No. Multifunction Meter With RS-485 port

-

-

-

... More
1 set C.T's 320/5Amp , CL 1.0, 15VA for meter

-

-

-

... More
1 No A/M Selector switch

-

-

-

... More
1 set Phase Indicating LED Lamps with backup MCB

-

-

-

... More
1 ses ON,OFF,TRIP indicating LED Lamps with backup MCB.

-

-

-

... More
Control SP MCB

-

-

-

... More
1 Nos. 8 window annunciator with accept / reset / test push button

-

-

-

... More
1 no. 24V battery

-

-

-

... More
INCOMER:- (FROM 62.5KVA DG) x1. for each :

-

-

-

... More
1 Nos 100A FP MCCB 35kA With Microprocessor Based Release (O/C,S/C,E/F) Protection & all Accessories in each :

-

-

-

... More
1 No. 100A FP Contactor

-

-

-

... More
1 No Under Voltage Relay (27)

-

-

-

... More
1 No Over Voltage Relay (59)

-

-

-

... More
1 No. Multifunction Meter With RS-485 port

-

-

-

... More
1 set C.T's 100/5Amp , CL 1.0, 15VA for meter

-

-

-

... More
1 No A/M Selector switch

-

-

-

... More
1 set Phase Indicating LED Lamps with backup MCB

-

-

-

... More
1 ses ON,OFF,TRIP indicating LED Lamps with backup MCB.

-

-

-

... More
Control SP MCB

-

-

-

... More
1 Nos. 8 window annunciator with accept / reset / test push button

-

-

-

... More
1 no. 24V battery

-

-

-

... More
Note: DG to be cranked from Main Panel only. AMF feature in Main panel only. DG's are on Auto Load Management via PLC.

-

-

-

... More
BUSCOUPLER x 1 Nos. For each:

-

-

-

... More
1 Nos 320A FP MCCB 35kA With Microprocessor Based Release (O/C,S/C,E/F) Protection & all Accessories in each :

-

-

-

... More
1 No. 320A FP Contactor

-

-

-

... More
1sets ON,OFF indicating LED Lamps with backup MCB.

-

-

-

... More
BUSBAR :-

-

-

-

... More
FP aluminium bus bars of minimum 400 Amp with heat shrinkable coloured sleeves , Shrouds at Joints and including DMC/SMC bus bars supports at required interval complete for cross section, side supports and their spacing etc. for withstanding fault level of 31 MVA for 1 sec

-

-

-

... More
OUTGOING

-

-

-

... More
ON Indication Light for all Outgoings. with backup MCB

-

-

-

... More
Section-A

-

-

-

... More
1 Nos. 250Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle FOR Fire Fighting

-

-

-

... More
1 Nos.160Amps TPN ,MCCB with Thermal Magnetic Release adjustable with rotary handle for 75KVAR capacitor Panel

-

-

-

... More
4 Nos. 100Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle

-

-

-

... More
3 Nos. 63Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle

-

-

-

... More
Section-B

-

-

-

... More
2 Nos. 100Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle

-

-

-

... More
4 Nos. 63Amps FP ,MCCB with Thermal Magnetic Release adjustable with rotary handle for Spare

-

-

-

... More
4 Nos. 63Amps FP ,MCB

-

-

-

... More
This panel should include 1 no. Busbar mounting Surge Protection Device Class B+C/ Class 1+2 Tested as per IEC 61643 Part 11:2011 & UL 1449 4th edition . Nominal voltage -230V 50/60Hz, MCOV of 350 V , Total Impulse current-50 KA (10/350µ sec) & Total Max Discharge current 560KA (8/20µ sec), Voltage protection level 1.3 kV . The Surge Protection Devices should have TOV withstand for 120 Min 440 V and with out Follow Current & the Protection Modes for : L & N to PE . The connections (Three Lines & Neutral) should be directly connected to Protective Earth Terminal for better response time. Short- Circuit Current rating (Isccr) – 85 kA/50 Hz. Total Response time 1 nano sec.

-

-

-

... More
Miscellaneous items

-

-

-

... More
2 nos door switch

-

-

-

... More
2 nos illumination lights with 6 A,10kA MCB

-

-

-

... More
ILLUMINATION LED WITH HOLDER & DOOR SWITCH

-

-

-

... More
2 nos 6" dia exhaust fan with thermostate & suitable canopy

-

-

-

... More
Internal illumination in Cable alleys with Door operated switch.

-

-

-

... More
complete panel as above

1

-

-

... More
Supply, Erection, Testing and commissioning of indoor type cubicle pattern LT Switch-Board with a rupturing capacity of 50 KA at 415 V or as called for in individual items, openable in front and back suitable for 3 phase, 4 wire, 50Hz AC supply at an ambient temperature of 45 C. The cubicle should be vermin proof, well ventilated and enclosure protection shall be IP-54 as per IS 2147-1962.or as per CPWD specifications, ( Part IV - Sub-station) and IS: 8623 The cubicle should be front operated, floor mounted, free standing with compartments in tier formation, extensible on both sides. The panel to be provided with PVC Sleeved TPN Electrolytic Al. Bus Bar and PVC insulated solid interconnections and also provided with 50x6mm. horizontal tinned copper Earth Bus Bars in each section.75kVAR APFC Panel.

-

-

-

... More
1 Nos. 160Amps TP ,MCCB with Thermal Magnetic Release adjustable with rotary handle from Main Panel

-

-

-

... More
1 set of Phase Indication LED lights each backed up with 6amp. MCB

-

-

-

... More
1 Nos VAF meter With RS-485 port

-

-

-

... More
1 no- RMI-12 APFC Microprocessor based Relay intelligent type for Transformer and DG side, relay setting 0.8 to .98 power factor) for capacitor bank .built in PF meter

-

-

-

... More
suitable contactor for above

-

-

-

... More
3 nos CT's 500/5A class-1(15VA)

-

-

-

... More
5 nos 6 amp SP MCB

-

-

-

... More
1no 6 amp DP MCB

-

-

-

... More
1 no Timer on delay (series 175) 220V AC

-

-

-

... More
Auto / Manual selector switch (3P,2 way with OFF)

-

-

-

... More
1 No Thermostat(30-80 degree)

-

-

-

... More
1 No. Aux. Contactor 8NO+8NC (220V AC)

-

-

-

... More
1 No. Aux. Contactor 4NO+4NC (220V AC)

-

-

-

... More
3 Nos. Aux. Contactor 4NO (220V AC)

-

-

-

... More
BUSBAR :-

-

-

-

... More
160 Amps 3 pole aluminum conductor ( CD 0.8A /sq.mm. ) bus bar (PVC sleeve Heat-shrinkable busbar insulation) supported by DMC / FRP insulator (MAIN BUSBAR)

-

-

-

... More
OUTGOING

-

-

-

... More
8 sets of ON -OFF push buttons station red & green with ON/OFF indicating lights for each KVAR capacitor unit to indicate its position.

-

-

-

... More
8 nos Ammeter suitable for each capacitor Bank with CT

-

-

-

... More
Branch Protection

-

-

-

... More
1 nos 10 amp TP 10 KA MCB for 5 KVAr

-

-

-

... More
1 nos 20 amp TP 10 KA MCB for 10 KVAr

-

-

-

... More
1 nos 32 amp TP 10 KA MCB for 15 KVAr

-

-

-

... More
1 nos 40 amp TP 25 KA MCCB for 20 KVAr

-

-

-

... More
1 nos 63 amp TP 25 KA MCCB for 25 KVAr

-

-

-

... More
Capacitor Duty Contactor

-

-

-

... More
1 nos. Capacitor duty contactor suitable rating for 5 kVAR Rating

-

-

-

... More
1 nos. Capacitor duty contactor suitable rating for 10 kVAR Rating

-

-

-

... More
1 nos Capacitor duty contactor suitable rating for 15 kVAR Rating

-

-

-

... More
1 nos. Capacitor duty contactor suitable rating for 20kVAR Rating

-

-

-

... More
1 nos. Capacitor duty contactor suitable rating for 25kVAR Rating

-

-

-

... More
Detuned Harmonic Filters

-

-

-

... More
1 nos. 440 V, 14% detuned 5 Kvar reactor

-

-

-

... More
1 nos. 440 V, 14% detuned 10 Kvar reactor

-

-

-

... More
1 nos. 440 V, 14% detuned 15 Kvar reactor

-

-

-

... More
1 nos. 440 V, 14% detuned 20 Kvar reactor

-

-

-

... More
1 nos. 440 V, 14% detuned 25 Kvar reactor

-

-

-

... More
Capacitor Banks

-

-

-

... More
1 nos. 525 V, 10 kvar super heavy Capacitor Bank for 5 kvar

-

-

-

... More
1 nos. 525 V, 12.5 kvar super heavy Capacitor Bank for 10 kvar

-

-

-

... More
1 nos. 525 V, 20 kvar super heavy Capacitor Bank for 15 kvar

-

-

-

... More
1 nos. 525 V, 25 kvar super heavy Capacitor Bank for 20 kvar

-

-

-

... More
1 nos. 525 V, 30 kvar super heavy Capacitor Bank for 25 kvar

-

-

-

... More
Miscellaneous items

-

-

-

... More
4nos door switch

-

-

-

... More
4 nos illumination lights with 6 A,10kA MCB

-

-

-

... More
ILLUMINATION LED WITH HOLDER & DOOR SWITCH

-

-

-

... More
4 nos 6" dia exhaust fan with thermostate & suitable canopy

-

-

-

... More
Internal illumination in Cable alleys with Door operated switch.

-

-

-

... More
Complete Panel as Above and complete

1

-

-

... More
Design, Manufacture, Supply, Installation, Testing and Commissioning of Panel Fabricated out of 16 SWG CRCA sheet steel, IP 54, wall / floor mounting type with rain canopy The sheet steel shall undergo minimum 7 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes 415 /240 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands, including connection with outgoing feeders complete in all respect, Panel Should Have Double Earthing Provision Which Connected to the Nearest Earth Grid. External Lighting Panel

-

-

-

... More
INCOMER:

-

-

-

... More
1 no. 63 A, 18KA 4P MCCB with Thermal Magnetic based releases, ON indication, 1 no. multifunction meter with RS-485, with selector switch, matching cast resin CT's.

-

-

-

... More
BUS BAR

-

-

-

... More
TPN Aluminium bus bar with heat Shrink Sleeve rated for 160A.

-

-

-

... More
OUTGOING

-

-

-

... More
4 nos 32A DP MCB ON indication lamps with 9 nos astronimical time swtich for automaitc switching of landscape light fixtures at sun set and sun rise or twillight ( auto on/ auto off and auto mode)with manual override faiclity with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site.

-

-

-

... More
2 nos 63A 4P MCB (SPARE)

-

-

-

... More
2 nos 40A 4P MCB (SPARE)

-

-

-

... More
Other items such as

-

-

-

... More
1 Set of control wiring

-

-

-

... More
1 Set of designation plates

-

-

-

... More
All Items complete as above

1

-

-

... More
Supplying of following sizes of 1.1 KV grade multicore aluminium conductor XLPE insulated armoured cable conforming to IS:7098 (Part - I) complete with all amendments etc. as required

-

-

-

... More
4Cx10

50

-

-

... More
4Cx16

200

-

-

... More
4Cx25

100

-

-

... More
3.5Cx35

150

-

-

... More
3.5Cx50

50

-

-

... More
3.5Cx70

100

-

-

... More
3.5Cx95

75

-

-

... More
3.5Cx120

100

-

-

... More
3.5Cx150

50

-

-

... More
3.5Cx185

250

-

-

... More
Supply and Laying of heavy duty copper armored cables 1.1 KV grade including necessary support clamps at ceiling level and connection legs,glands etc complete in all respects.

-

-

-

... More
Control cable 10 core 2.5 Sq.mm

50

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.

-

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

100

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

80

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

105

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

50

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.

-

-

-

... More
Upto 35 sq. mm (clamped with 1mm thick saddle)

420

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

120

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

20

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.

-

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

230

-

-

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required

2

-

-

... More
LT CABLE JOINTING & END TERMINATION

-

-

-

... More
Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required.

-

-

-

... More
4Cx10 sq. mm (25mm)

2

-

-

... More
4Cx16 sq. mm (28mm)

2

-

-

... More
4 X 25 sq. mm (28mm)

2

-

-

... More
3½ X 35 sq. mm (32mm)

4

-

-

... More
3½ X 50 sq. mm (35mm)

2

-

-

... More
3½ X 70 sq. mm (38mm)

2

-

-

... More
3½ X 95 sq. mm (45mm

2

-

-

... More
3½ X 120 sq. mm (45mm)

4

-

-

... More
3½ X 150 sq. mm (50mm)

4

-

-

... More
3½ X 185 sq. mm (57mm)

4

-

-

... More
Supply & Testing of following 11 KV( UE) grade multicore Aluminium conductor XLPE insulated cable, insulation screening with extruded semi conducting compound in combination with copper tape armoured cores laid up, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - II) and complete with all latest amendments etc. complete as required.

-

-

-

... More
3 C x 70 Sq. mm 11 KV (E)

40

-

-

... More
H V CABLE LAYING

-

-

-

... More
Laying of one number XLPE power cable of 33 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required

-

-

-

... More
Upto 120 sq. mm

40

-

-

... More
H.T Termination:

-

-

-

... More
Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required

-

-

-

... More
120 Sq.mm

2

-

-

... More
Supplying and making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required

-

-

-

... More
120 Sq.mm

3

-

-

... More
Hot Dipped Galvanized Iron Cable Tray 4.6 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc.as requiredSupplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (Cable Tray Bends as per Requirement)

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

200

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

500

-

-

... More
450 mm width X 50 mm depth X 2.0 mm thickness

300

-

-

... More
MISCELLANEOUS ITEMS -

-

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

10

-

-

... More
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single Red colour on front side as required.

2

-

-

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required

-

-

-

... More
150 mm dia

50

-

-

... More
Construction of masonary chamber 900 x 900 x 1000 size

2

-

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required

-

-

-

... More
63 mm dia (OD-63 mm & ID-51 mm nominal

100

-

-

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

50

-

-

... More
Supplying and fixing integral post top lantern with 30 watt LED fitting comprises of copper dust finish cast aluminium spigot and spun aluminium canopy fixed with opal polycarbonate, pipe arrangement for vertical mounting, open construction driver and accessories are wired up to terminal block. LED of 1 to 3 W each assembled on single MCPCB, having color temp 6500K & having 50000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy80lm/W. LED driver PF 0.95 & surge protection 2KV.The colour rendering index of LED light should be more than 70. Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer manadatory. i/c connection wire, testing etc. to complete the job. 2 Yrs Guarantee certificate from manufacturer.similar to MF PTL LED 656 / oriant

4

-

-

... More
Supply , Installation, Testing & Commissioning of street light 60 W LED with complete with pot optic reflector including connection with 3x2.5sq.mm single core PVC insulated copper conductor cable from junction box to fixture as required

12

-

-

... More
Supply, Installation, Testing and Commissioning of 202x238x111 (KVPC) Polycarbonate thermoplastics enclosure - junction box with I.P - 65 Protection with cable hinged cover of approved design complete having gasket of internally embedded & made of polyeutherene & should be weather proof, rust proof, dust proof, water proof - box shall be tested as per IEC - 60670-2/60670-22. the box shall have self threaded holes & provision for mounting din rail. with 2 Nos cable gland including supplying & fixing crimping 2 nos lugs & 1 nos 32A connector 6 way for looping the incoming & outgoing cables and also connection of the street light one 6A SP MCB Including Connection of 2x6 sqmm Cable etc as Required

12

-

-

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including Fixing in ground (75 cm deep)and re-filling etc as required for Post Top light 80 mm dia 4.75 mtr long with base plate

4

-

-

... More
Supplying of 8 mtr long hot dip Galvanized octagonal Pole with top of the pole 70 mm dia (A/F) and bottom of the pole 135 mm dia (A/F) made out of 3mm sheet with MS base plate of size 225mm (NS) x 225mm (NS) x 16mm (NS) on precast RCC foundation complete with suitable size opening inside the pole with flush weather proof door with locking facility preferably with LN key having proper arrangement with Accommodating of 1 Nos. 6 Amp.,10 KA MCB & neutral link 4 way connector suitable for 25 Sqmm cable complete with electrically safe including inside cable termination with thimbles i/c wiring from pole box to fitting with 3x1.5 sq.mm. FRLS PVC insulated copper conductor wire, earth connection, din channel, earth stud and other accessories pertaining to this pole (But without street light fitting) etc as reqd.including providing & laying in position suitable RCC foundation as required for 6 mtr. octagonal hot dip Galvanized Pole as per Manufacturers drawing with 1:1.5:3 concrete (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) including excavation of all kind of earth such as all type of soil/soft rock or hard rock etc. as per existing site condition i/c providing, cutting, bending and placing reinforcement & J type foundation bolts , anchor plate and templates in position as per manufacturer Standard and Providing PVC Pipe for Cable Entry and Exits Including Disposal of Surplus Malba / Softrock / Hardrock Stone etc.as Required.

12

-

-

... More
Supplying, Drawing, Connecting and Testing of Following Size of PVC Insulated FRLS Copper Conductor (as per IS : 694) flexible Multicore Wire in the existing poles and bracket from cable termination connector / MCB to the fitting i/c providing suitable connectors 3 core 2.5 sq.mm (for 8Mtr Poles + POST TOP+ BOLLARD)

100

-

-

... More
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required 6.5 meter and upto 8.0 meter

16

-

-

... More
Supply, Installation, Testing And Commisioning of 1 No. Indoor Digital Micro Processor Based Servo Voltage Stabilizer 200 kVA, Linear Type, Indoor, 3 Phase, Balanced Type, Input Voltage 330-470V Output voltage 400V ±1% .

1

-

-

... More
Supply and fixing of lift 13 Parson I/C all material T&P etc Complete.

2

-

-

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 19.19.1 L D- 2.5 Rectangular shape 600x450 mm internal dimensions

2

-

-

... More
Inlet Pipe 100 mm dia

1

-

-

... More
Outlet Pipe 100 mm dia

1

-

-

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long co mplete as per standard design With common burnt clay F.P.S. (non modular) bricks of classdesignation 7.5

1

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200mm

10

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.300 mm dia

10

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

24

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.

24

-

-

... More
Providing & fixing of R.C.C manhole covering tank (600 x 600)

2

-

-

... More
Providing & fixing of foot rest in tank

10

-

-

... More
Center Shuttering

40

-

-

... More
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

4

-

-

... More
Providing and fixing white viterous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & CP flush bend with fittings & CI brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid.

22

-

-

... More
Providing and fixing water closet water closet squatting pan (Indian Type W.C Pan) with 100mm sand cast iron 'P' or 'S' trap, 10 ltrs low level, PVC flushing cistern with manually controlled device (handle lever)conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever requiredand as per direction of Engineer -In-charge: White Vitreous China Orissa pattern W.C pan of size 580 x 440 mm with integral type foot rests.

6

-

-

... More
Providing and fixing C.P. brass short body bib cock with flange of approved quality confirming to IS: 8931

-

-

-

... More
15mm nomonal bore

28

-

-

... More
Providing and fixing wash basin with CI/MS brackets, 15mm CP brass pillar taps, 32mm CP brass waste of standard pattern, including painting of fitting and brackets, cutting and making good the walls wherever required.

-

-

-

... More
White Vitreous China wash basin (oval) size550 x 400 mm with single 15mm CP brass pillar tap

27

-

-

... More
White Vitreous China flat back wash basin size550 x 400 mm with single 15mm CP brass pillar tap

4

-

-

... More
Bottle trap 38mm single piece moulded with height of 270mm, effective length of tail pipe 260mm from centre of the waste coupling 77mm breadth with 25mm minimum water seal, weighing not less than 263gms.

31

-

-

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass union and G.I clamps complete, including painting and brakets, cutting and making good the walls and floor wherever required One urinal basin with 5 litre white PVC automatic flushing cistern

12

-

-

... More
Providing and fixing C.P. brass quality angle valve15 mm dia. For basin mixer and gyser points of approved quality, confirming to IS : 8931

-

-

-

... More
15mm nomonal bore

31

-

-

... More
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make confirming to IS : 8931. 15mm nomonal bore

31

-

-

... More
Providing & fixing PTMT liquid soap container109mm wide,125mm high and 112mm distance from wall of standard shape and brackets of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.

31

-

-

... More
Providing & fixing PTMT towel ring trapezoidal shape 215 mm long,200mm wide with a minimum distance of 37mm from wall face with concealed fitting arrangement of approved quality and colour weighing not less than 88 gms.

31

-

-

... More
Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design.

31

-

-

... More
Providing & fixing 600x450mm beveled edge mirror of superior glass ( of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washer complete.

31

-

-

... More
Providing and fixing C.P. brass

31

-

-

... More
Providing and fixing soil, waste and vent pipes: 100 mm dia Centrifugally cast (spun) iron socketed pipe as per IS 3989.

207

-

-

... More
Centrifugally cast (spun) iron socketed pipe as per IS 3989

207

-

-

... More
Providing and fixing M.S holder-bat clamps of approved design to sand cast iron/sand cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix ( 1cement:2coarse sand: 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc

-

-

-

... More
For 100 mm dia pipe

123

-

-

... More
For 75 mm dia pipe

123

-

-

... More
Providing and fixing bend of required degre with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.

-

-

-

... More
100 mm

-

-

-

... More
Centrifugally Cast (Spun)Iron S & S pipe as per IS : 3989

123

-

-

... More
Providing and fixing plain bend of required degree

-

-

-

... More
100 mm

-

-

-

... More
Centrifugally Cast (Spun)Iron S & S pipe as per IS : 3989

123

-

-

... More
75 mm

-

-

-

... More
Centrifugally Cast (Spun)Iron S & S pipe as per IS : 3989

123

-

-

... More
Providing and fixing single equal plain junction of required degree with access door, insersion rubber washer 3 mm thick, bolts and nuts complete.

-

-

-

... More
100x100x100 mm

-

-

-

... More
Sand cast iron S & S as per IS 3989

123

-

-

... More
75x75x75 mm

-

-

-

... More
Sand cast iron S & S as per IS 3989

123

-

-

... More
Providing and fixing double equal plain inverted branch of required degree

-

-

-

... More
100x100x100x100 mm

-

-

-

... More
Sand cast iron S & S as per IS 3989

123

-

-

... More
Providing and fixing terminal guard.

-

-

-

... More
100 mm

-

-

-

... More
Sand cast iron S & S as per IS 3989

123

-

-

... More
75 mm

-

-

-

... More
Sand cast iron S & S as per IS 3989

123

-

-

... More
Providing and fixing collar

-

-

-

... More
100 mm

-

-

-

... More
Sand cast iron S & S as per IS 3989

123

-

-

... More
75 mm

-

-

-

... More
Sand cast iron S & S as per IS 3989

123

-

-

... More
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter:

-

-

-

... More
100 mm

123

-

-

... More
75 mm

123

-

-

... More
Providing and fixing M.S stays and clamps for sand cast iron / Centrifugally Cast (Spun) Iron Pipes iron pipes of diameter.

-

-

-

... More
100 mm

123

-

-

... More
75 mm

123

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 M spacing. This include jointing of pipes & fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge.

-

-

-

... More
15 mm nominal outer dia Pipes

61

-

-

... More
20 mm nominal outer dia Pipes

61

-

-

... More
25 mm nominal outer dia Pipes

61

-

-

... More
32 mm nominal dia Pipes

61

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 M spacing. This include jointing of pipes & fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge.

-

-

-

... More
Concealed work including cutting chases and making good the walls etc.

-

-

-

... More
15 mm nominal outer dia Pipes

61

-

-

... More
20 mm nominal outer dia Pipes

61

-

-

... More
25 mm nominal outer dia Pipes

61

-

-

... More
32 mm nominal outer dia Pipes

61

-

-

... More
External Works

-

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This include jointing of pipes & fitting with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge.

-

-

-

... More
50 mm nominal outer dia Pipes

61

-

-

... More
62.50 mm nominal outer dia Pipes

61

-

-

... More
Providing & fixing ball valve (brass) of approved quality, High or low pressure with plastic floats complete

-

-

-

... More
15 mm nominal bore

10

-

-

... More
20 mm nominal bore

10

-

-

... More
25 mm nominal bore

10

-

-

... More
Providing & fixing gun metal gate valve with C.I wheel of approved quality, (Screwd end)

-

-

-

... More
32 mm nominal bore

10

-

-

... More
40 mm nominal bore

10

-

-

... More
50 mm nominal obore

10

-

-

... More
Providing and placing on terrace (at all floor levels polyethylene water storage tank ISI : 12701 marked water storage tank with cover and suitable locking arrangement and making necessary holes for inlet outlet and overflow pipes but without fittings and the base suport for tank

8000

-

-

... More
Constructing masonary chamber 30x30xx50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement : f fine sand) for gate valve with C. I. susface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 ( 1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design with F. P. S. bricks

31

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110mm Dia

60

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.

-

-

-

... More
Coupler 110mm

12

-

-

... More
Bend 87.5° 110mm Bend

18

-

-

... More
Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm

30

-

-

... More
Providing and fixing 40mm dia with length not less than 700mm waste pipe for sink and wash basin. complete job.

36

-

-

... More
Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3.5.

434.88

-

-

... More
Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203

36.24

-

-

... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing

-

-

-

... More
1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)

10.5

-

-

... More
Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls, retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&P and royaltiies etc. complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203 of MORD Specifiction

624.74

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more

190

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.