North Eastern Railway Tender

View complete overview of Uttarakhand NER Tender

North Eastern Railway - NER Tender

Works
Machinery and Tools
Electrical and Electronics
Electrical Works
Ireps
Opening Date30 May 2024
Closing Date28 Jun 2024
Tender Amount₹ 41,35,436.2 
Notes
Download

Costs

Summary

Electrical Work In Connection With Development/upgradation Of Good Shed At Banbasa And

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and Erection of white finished mounting single mounting cover plate with base frame 12 modules suitable for mounting of modular type piano switches/plug socket, fan regulator and connecting to wiring complete in all respect.

30

191

5740.2

... More
Supply and Erection of Modular metal boxes concealed boards suitable for mounting of 12 module white finish single mounting cover plate with frame and modular type piano switches/plug socket, fan regulators. Metal board boxes are to be concealed in wall complete in all respect.

30

116

3481.5

... More
Supply and Erection of white finished mounting single mounting cover plate with base frame 8 modules suitable for mounting of modular type piano switches/plug socket, fan regulator and connecting to wiring complete in all respect.

30

132

3975.6

... More
Supply and Erection of Modular metal boxes concealed boards suitable for mounting of 8 module white finish single mounting cover plate with frame and modular type piano switches/plug socket, fan regulators. Metal board boxes are to be concealed in wall complete in all respect.

30

72

2164.2

... More
Supply and Erection of white finished mounting single mounting cover plate with base frame 3 module suitable for mounting of modular type piano switches/plug socket, fan regulator and connecting to wiring complete in all respect.

200

62

12546

... More
Supply and Erection of Modular metal boxes concealed boards suitable for mounting of 3 module white finish single mounting cover plate with frame and modular type piano switches/plug socket, fan regulators. Metal board boxes are to be concealed in wall complete in all respect.

200

41

8232

... More
Supply, Installation, testing & commissioning of Testing modular switch 10 Amps (1- way) complete in all respect as per direction of Engineer incharge.

300

58

17640

... More
Supply, Installation, testing & commissioning of modular type plug socket outlet 2/3 pin 10 Ampere complete in all respect as per Direction of Engineer incharge.

100

97

9724

... More
Supply, Installation, testing & commissioning of modular type switch 20 Amps (1- way) complete in all respect as per direction of Engineer incharge.

20

119

2399.6

... More
Supply, Installation, testing & commissioning of modular type plug socket outlet 5/3 pin 20 Ampere complete in all respect as per direction of Engineer incharge.

20

138

2776

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 1.5 sq.mm confirming to IS: 694 (Latest version) and drawing in laid(recessed/surface) PVC Conduit pipe for earth wire as required as per technical specification including connections, testing and commissioning complete in all respect.

2000

11

23540

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 2.5 sq.mm 15 confirming to IS: 694 (Latest version) and drawing in laid(recessed/surface) PVC Conduit pipe for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect.

4000

18

72000

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 4.0 sq.mm 16 confirming to IS: 694 (Latest version) and drawing in laid(recessed/surface) PVC Conduit pipe for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect.

1000

27

27780

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 6.0 sq.mm 17 confirming to IS: 694 (Latest version) and drawing in laid(recessed/surface) PVC Conduit pipe for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect.

1000

38

38350

... More
Digging of trench in all kinds of soil up to the depth of 750 mm and 350 mm wide for laying of cable 18 with supply and placing of second-class bricks, approx. 10 bricks per meter, refilling of cable trench with solid earth consolidating by ramming by 270 mm above the surrounding level over trench. (Digging of trench conforming to IS 1255).

3000

49

148410

... More
Laying of XLPE (LT) cable of different sizes in excavated cable trench and in underground pipes. (Laying of cable conforming to IS: 1255).

5000

5

28750

... More
Fixing, connecting, testing & commissioning of ventilating fan (Exhaust fan), plastic body, wall mounting 250 mm sweep complete in all respect as per direction of engineer incharge. Note: -Exhaust fan will be supplied by railway at site.

10

89

892.3

... More
Supply and recessing/fixing on surface of 6 SWG GI wire confirming to IS: 280/2006 (latest version) for earthing as required for earthing of installation as per IE Rule.

150

11

1713

... More
Installation , connection with twin core PVC insulated flexible copper conductor HRFR cable of size 22 14/0.193 mm (0.41 sq.mm) testing and commissioning of 1200/1400 mm sweep AC ceiling fan/Air circulator (on the installed CI/MS Box) including earthing as per technical specification complete in all respect as per direction of engineer incharge. Note: - AC ceiling fan/Air circulator will be supplied by railway at site.

20

33

679.6

... More
Fixing, connecting, testing & commissioning of LED Tube light fitting 20 watt/ LED down lighter 23 including making of hole in wall/ceiling by drilling machine for fixing tube light fitting with rowal plug 2 Nos & connecting with ceiling rose and connecting to electric supply wire complete in all respect. Note:-Fitting will be supplied by railway at site.

300

52

15747

... More
Supply, Installation, Testing & commissioning of SPN MCB Distribution board 4-way double door 24 made with 1.2 mm thickness CRCA sheet fully powder coated of 50-70 micron with 01 No. MCB 02 pole 40 Amperes 10 KA 230 V as incoming and 02 Nos MCB of 6-25 Amp single pole 10 KA, 230 volts as outgoing complete in all respect including connection as required

10

1028

10289

... More
SITC of VTPN distribution board 4 way as per IEC 61439-3, suitable for flush mounting and surface mounting, 100 Amps copper bus bar for each phase with two neutral bar, two earth bar and cable ties for cable management, fully insulated bus bar & shrouded Neutral bars, Improved Pan assembly for ease of installation, 25 refitted masking sheet, with provision for TPN MCB as incomer and SP MCB's outgoing, IP 43 with metal door with fixing & connecting. Along with 01 No.- MCCB's 4 pole 100 Amps, Breaking capacity 25 KA, rated voltage 415V 50 Hz AC supply conforming to IS: 13947 (Pt.1&2)/IEC60947-1&2- 03 No.- MCB 'C' curve, no. of poles -two pole, rated voltage 415 V AC, rated current Amps:63 Amps, rated short circuit current capacity 10 KA rated frequency : 50 Hz, AC conforming to IS:60898-1/2002. 10 No.- Single pole MCB 16 Amps, 'C' curve, 10 KA, ISI marked conforming to IS/IEC 60898-1-2002.

4

23616

94466

... More
Supply, making testing & commissioning of pipe earthing arrangement with GI pipe 'B' class, 40 26 mm dia 4.50 mtrs, long including accessories & providing masonry enclosure with cover plate of 16 SWG M.S. having locking arrangement watering pipe , salt , charcoal etc. As per Drg. NO. DRM / Elect/IZN /16-89 to achieve earth resistance less than 10 ohms and connecting the equipment with 6 SWG G.I. wire as per site requirement. Earthing shall be done on the basis of code of practice for earthing as per IS: 3043/1987.

30

1375

41278.8

... More
Supply, installation, Testing and Commissioning 16-meter-long high mast lighting system complete with the following works: -1.1 Supply of 16-meter-high mast system: - The mast shaft shall be in two sections hot dip galvanized inside and outside in single dip, suitable for wind velocity as per IS:875 part 3. There shall be only one longitudinal seam weld per section and no circumferential weld. It shall also include accessories for high mast including head frame, 2 point suspension system with stainless steel wire rope tralling cable, connector, 6 mm dia double drum winch, galvanized lantern carriage arrangement suitable for 08 luminaries LED type symmetrically arranged. The mast shall have an integral power tool motor, manual handle, junction box at the base compartment for its operation. 1.2 Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates & common template (Set 01) 1.3 Supply, fixing, testing and commissioning of LED flood light fixture 250 watt, power factor not less than 0.95 and LED driver should be constant voltage & current and fitting should be IP 66-08 Nos.LED fitting shall conform to BIS specification No. 10322 (Pt.5/sec. 1)/2012 or latest. 1.4 Supply of LED type single dome aviation obstruction light. 1.5 Design & making of outdoor stand mounted feeder pillar control panel with 63 Amps TPN MCB incomer, single dial time switch, 45 Amps TP contractor for the 27 automatic switching of luminaries, power tool control with 02 no. 9 Amps contractors and raise lower push button, incoming 35 mm & outgoing 16 & 2.5 mm2 terminals. (set 01) 2. Erection Part:-2.1 Design construction & erection of suitable shallow foundation with M20 concrete for the high mast considering the safe soil bearing capacity at site as 10 T/ sq.mtr at 2 mtr depth with all material & labour (Job-01) 2.2 Erection of the high mast with the help of suitable equipment and wiring of luminaries with all wiring material like PVC insulated, PVC sheathed flexible cable of suitable copper conductor, cable lugs, MCB etc and all labours. 2.3 Provision of G.I. pipe earthing arrangement for high mast with 4.5 M long 40 mm dia G.I. pipe including connection to high mast earth terminal with 25 x 3 mm G.I. earth strip with all materials and labour as per Drg. No. DRM/Elec./IZN/16-89 (Nos 02) 2.4 Installation, testing and commissioning of control panel on suitable foundation including all material & labour (Job 01).Note:-1. High mast system should be as per enclosed specification. Note: - Complete High Mast system with LED flood light shall be inspected by the RITES as per specification at the manufacture premises and inspection cost shall be borne by the contractor. (Successful Tenderer shall submit WARRANTEE GUARANTEE (WG) @ 10% of the Contract Value of this item in the prescribed proforma before claiming the payment for this item.) Note:- High Mast and LED flood light fixture 250 Watt shall be guaranteed/warranted for a period of 60 months from the date of commissioning for satisfactory performance.

2

395746

791493.36

... More
Making of hexagonal platform foundation with Rail post and including all accessories for high mast 28 lighting tower in in yard and goods siding as per CEE's Drg No. L/CEE/GKP/2010/2 as enclosed with all materials. Note:-1. Only rail pole will be supplied by the railway.2. Cutting of rail post 1750 mm length (each) is included in the scope of work.

2

10256

20512.48

... More
Supply, Fixing of distribution box in foundation, connecting testing and commissioning of LT distribution box made of 1.6 mm thick cold rolled steel sheet of size 600 mm (L) x 450 mm (W) x300 mm (D) with provision of water proof , hinged door, suitable locking arrangements, proper hole in the bottom for cable entry 29 (incoming & out going cables) -05 Nos suitable and MS channel of size 75mm x 40mmx 4mm should be fixed across the panel for grouting on the foundation, earthing terminals and panel shall be powder coated (paint) greenish grey shade with TPN Copper Busbar of 600 Amps with provision of water proofing and installation on Providing and making foundation to double door feeder pillar box (cubical type L.T. panel) in CC 1:2:4 with stare aggregate. [Size 1220 mm high x 800 mm length and 600 mm width (610 mm under the earth & 610 mm above the earth) with fine finish to exposed surface, two coats white washing including excavation of foundation, making proper size hole for incoming and outgoing cables. Grouting of holding down bolt in CC (size of bolt 150 mm long 16mm dia.) includes fixing of sub distribution box on CC foundation and as per direction of engineer in charge at site.

20

11658

233160

... More
Supply, erection and testing of hot dip galvanized tapered octagonal pole of 5.0 Mtrs. Long top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate dimension (L x B x T) 200 mm x 200 mm x 12 mm & foundation bolts size (No. x dia x length) (4 x M16 x 600 mm), PCD 200 mm, anchor plate thickness 3 mm with hot dip galvanized detachable single arm bracket made by 48.3 mm outer dia pipe 300 mm long with 32 mm 30 outer dia sleeve including erection & fixing on the foundation. (Octagonal pole shall confirm to IS: 2629 or latest.) Note:-1. Galvanized thickness of pole should be minimum 65 microns and test report to be submitted by the contractor at the time of supply. 2. Octagonal pole shall have flush door arrangement and suitable size & length of cable connecting plate for incoming and outgoing cables as per standard. Note:-Octagonal pole shall be inspected by the RITES as per specification at the manufacture premises and inspection cost shall be borne by the contractor.

20

6731

134632.6

... More
Supply, erection and testing of hot dip galvanized tapered octagonal pole of 5.0 Mtrs. Long top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate dimension (L x B x T) 200 mm x 200 mm x 12 mm & foundation bolts size (No. x dia x length) (4 x M16 x 600 mm), PCD 200 mm, anchor plate thickness 3 mm with 31 hot dip galvanized detachable double arm bracket made by 48.3 mm outer dia pipe 300 mm long with 32 mm outer dia sleeve including erection & fixing on the foundation. (Octagonal pole shall confirm to IS: 2629 or latest.) Note:-1. Galvanized thickness of pole should be minimum 65 microns and test report to be submitted by the contractor at the time of supply. 2. Octagonal pole shall have flush door arrangement and suitable size & length of cable connecting plate for incoming and outgoing cables as per standard.

50

7020

351016.5

... More
Making trench of size 300 mm x 300 mm x 1000 mm and Casting/grouting of pre-cast foundation CC 1:2:4 block size 300 mm x 300 mm x 1000 mm grouting with 20 mm size stone aggregate with cement & 32 coarse sand including supply, fixing and removing all firm work and finishing exposed surface including grouting and holding down-M 16x 450 mm- 4 Nos bolts in cement block as per requirement of pole base plate of size 200x200x12 mm and supply & fixing Double Walled Corrugated (DWC DPDE Duct Pipe, size 90/76 mm, confirming to IS:14930 (Part-II) 0.75 meter length in the centre of cement concrete block for cable entry and fixing properly with all labour, material, cement etc. complete in all respect as per direction of engineer in-charge at site.

70

1910

133728.7

... More
Fixing connecting testing and commissioning of LED street light fitting 90 watt and LED Flood light 33 on pole/ covered shed including supply and connection with twin core PVC insulated flexible copper conductor cable of size 1.5 sq.mm complete in all respect as per direction of engineer incharge at site. Note:-LED street light fitting will be supplied by railway at site.

120

81

9778.8

... More
Fixing connecting testing and commissioning of LED high bay light fitting 150 watt on covered 34 shed/wall/Pole including supply and connection with twin core PVC insulated flexible copper conductor cable of size 1.5 sq.mm complete in all respect as per direction of engineer incharge at site. Note:-LED high bay light fitting will be supplied by railway at site.

20

97

1940

... More
All work pertaining to Horizontal Directional Drilling (HDD)/Boring and trench less cabling. It includes supply, transportation and insertion of self-lubricated HDPE pipe and laying of cable in boring under the 35 track/road by using different sizes of pipes depending on total number of cables will be crossed. The depth of horizontal boring should be 3 mtrs from rail flange/road level. This item will be used for track crossing of running lines.) By using self-lubricated HDPE pipe of 108.60 mm inner dia and 125 mm outer dia (PN-6) as per IS:4984 or latest in the bore and the laying of cables in the track/road.

50

1066

53301.5

... More
Design Manufactucturing Supply of L.T. Switch board panel with for provision of consisting with installation, connecting, testing and commissioning LT. switch board panel of cubical type as per CPWD General specification for electrical works, Part- IV substation 2013 including made of 2.0 mm. thick CRCA sheet of suitable size with provision of water proof, hinged door, suitable locking arrangements, proper hole in the bottom for cable entry (incoming & out going cables), 05no. suitable MS channel of size should be fixed across the panel for grouting on the foundation, earthing terminals and panel shall be powder coated (paint) greenish grey shade with proper arrangement of protection against rain/water & including sub copper bus bar, CTs & others accessories consisting with the following accessories with Supply fixing connecting testing & commissioning of Incoming Main 36 MCCB with thermal magnetic trip unit 250 Amps, 04 poles, braking capacity 25 kA. Conforms to Ics=100% Icu as per IEC 60947-2, adjustable thermal setting 0.7 x1x In. suitable for 415 volts 50Hz. AC supply-01 No, Supply fixing connecting testing commissioning of Main copper Bus Bar TPN 600 Amp.-02 Sets, Supply fixing connecting testing commissioning of LED Multifunction Meter, accuracy class 1 with RS485. Input voltage measurement range 170-520 VAC. Aux supply 90-300 VAC. flush mounted 96 x 96 mm. Parameters Model A V, A, F, PF. KW, KVA, KVAR. KWh, kVAh, kVARh. Runhours. On hours, Intrrupts, RPM. %Unbalance (VA) Phase angle, THD -06 Set with Supply fixing connecting testing & commissioning of On load Manual Change witch 63 Amps. 04 pole, site convertible fuse version for open execution, site convertible dual shaft position, staggered terminals., 415 volts, 50 Hz. complete with all respect-1 No, Supply fixing connecting testing commissioning of Indicating lamps for incoming & outgoing feeders-18 No., Supply fixing connecting testing commissioning Outgoing No MCCB DH100. 50-63 Amps. 04 poles, braking capacity 25 kA. Conforms to IS/IEC 47-2 adjustable overload setting 0.8 x 1.0 x In. suitable for 415 volts, 50 Hz, AC supply-03 Nos, Supply fixing connecting testing commissioning Outgoing MCCB 25-32 Amps. 04 poles. braking capacity 18 kA. Confirming to IS/IEC 60947-2. Adjustable overload setting 0.8 x 1.0 In. suitable for 415 Volts, 50 Hz. AC supply-02 No and Supply fixing connecting testing commissioning of providing of sub copper bus bar for connecting MCCBs for outgoing feeders with suitable size of copper lugs and cable will be connected aluminum lugs through cable glands etc as required complete in all respect as per direction of engineer- incharge at site.

1

126100

126100

... More
Supply and recessing/fixing of PVC Conduit pipe 25mm dia medium confirming to IS: 9537/Part III/1983 (Latest version) with accessories, junction box etc including making chase, plastering/clamping etc as per technical specifications.

500

36

18465

... More
Supply and recessing/fixing of PVC Conduit pipe 25mm dia medium on surface confirming to IS: 9537/Part III/1983 (Latest version) including supply & fixing with all accessories i.e junction box, bend, clamping etc as per technical specifications complete in all respect.

500

34

17425

... More
Supply and Installation of Ceiling rose 3 plate as per IS:371/1999 (Latest version) including connections, testing and commissioning as per technical specification as per direction of Engineer incharge.

100

13

1369

... More
Supply and Erection of white finished mounting single mounting cover plate with base frame 12 modules suitable for mounting of modular type piano switches/plug socket, fan regulator and connecting to wiring complete in all respect.

20

191

3826.8

... More
Supply and Erection of Modular metal boxes concealed boards suitable for mounting of 12 module white finish single mounting cover plate with frame and modular type piano switches/plug socket, fan regulators. Metal board boxes are to be concealed in wall complete in all respect.

20

116

2321

... More
Supply and Erection of white finished mounting single mounting cover plate with base frame 8 modules suitable for mounting of modular type piano switches/plug socket, fan regulator and connecting to wiring complete in all respect.

20

132

2650.4

... More
Supply and Erection of Modular metal boxes concealed boards suitable for mounting of 8 module white finish single mounting cover plate with frame and modular type piano switches/plug socket, fan regulators. Metal board boxes are to be concealed in wall complete in all respect.

20

72

1442.8

... More
Supply and Erection of white finished mounting single mounting cover plate with base frame 3 08 module suitable for mounting of modular type piano switches/plug socket, fan regulator and connecting to wiring complete in all respect.

60

62

3763.8

... More
Supply and Erection of Modular metal boxes concealed boards suitable for mounting of 3 module white finish single mounting cover plate with frame and modular type piano switches/plug socket, fan regulators. Metal board boxes are to be concealed in wall complete in all respect.

60

41

2469.6

... More
Supply, Installation, testing & commissioning of Testing modular switch 10 Amps (1- way) complete in all respect as per direction of Engineer incharge.

150

58

8820

... More
Supply, Installation, testing & commissioning of modular type plug socket outlet 2/3 pin 10 Ampere complete in all respect as per Direction of Engineer incharge.

100

97

9724

... More
Supply, Installation, testing & commissioning of modular type switch 20 Amps (1- way) complete in all respect as per direction of Engineer incharge.

20

119

2399.6

... More
Supply, Installation, testing & commissioning of modular type plug socket outlet 5/3 pin 20 Ampere complete in all respect as per direction of Engineer incharge.

20

138

2776

... More
Supply and Erection of modular type switch blanking set to g Set to fill the blank space white finished mounting cover plate complete in all respect.

20

7

142.6

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 1.5 sq.mm confirming to IS: 694 (Latest version) and drawing in laid (recessed /surface) PVC Conduit pipe for earth wire as required as per technical specification including connections, testing and commissioning complete in all respect.

1500

11

17655

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 2.5 sq.mm 16 confirming to IS: 694 (Latest version) and drawing in laid( recessed /surface) PVC Conduit pipe for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect.

2000

18

36000

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 4.0 sq.mm 17 confirming to IS: 694 (Latest version) and drawing in laid( recessed /surface) PVC Conduit pipe for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect.

1000

27

27780

... More
Supply of PVC insulated multi stranded copper conductor single core HRFR cable 6.0 sq.mm 18 confirming to IS: 694 (Latest version) and drawing in laid( recessed /surface) PVC Conduit pipe for wiring of point wiring/ circuit wiring /submain/main as required as per technical specification including connections, testing and commissioning complete in all respect.

800

38

30680

... More
Fixing, connecting, testing & commissioning of ventilating fan (Exhaust fan), plastic body, wall mounting 250 mm sweep complete in all respect as per direction of engineer incharge. Note:-Exhaust fan will be supplied by railway at site.

4

89

356.92

... More
Supply and recessing/fixing on surface of 6 SWG GI wire confirming to IS: 280/2006 (latest version) for earthing as required for earthing of installation as per IE Rule.

100

11

1142

... More
Installation, connection with twin core PVC insulated flexible copper conductor HRFR cable of size 21 14/0.193 mm (0.41 sq.mm) testing and commissioning of 1200/1400 mm sweep AC ceiling fan/Air circulator (on the installed CI/MS Box) including earthing as per technical specification complete in all respect as per direction of engineer incharge. Note: - AC ceiling fan/Air circulator will be supplied by railway at site.

10

33

339.8

... More
Fixing, connecting, testing & commissioning of LED Tube light fitting 20 watt/ LED down lighter 22 including making of hole in wall/ceiling by drilling machine for fixing tube light fitting with rowal plug 2 Nos & connecting with ceiling rose and connecting to electric supply wire complete in all respect. Note:-Fitting will be supplied by railway at site.

100

52

5249

... More
SITC of VTPN distribution board 4 way as per IEC 61439-3, suitable for flush mounting and surface mounting, 100 Amps copper bus bar for each phase with two neutral bar, two earth bar and cable ties for cable management, fully insulated bus bar & shrouded Neutral bars, Improved Pan assembly for ease of installation, 24 refitted masking sheet, with provision for TPN MCB as incomer and SP MCB's outgoing, IP 43 with metal door with fixing & connecting. Along with 01 No.- MCCB's 4 pole 100 Amps, Breaking capacity 25 KA, rated voltage 415V 50 Hz AC supply conforming to IS: 13947 (Pt.1&2)/IEC60947-1&2- 03 No.- MCB 'C' curve, no. of poles -two pole, rated voltage 415 V AC, rated current Amps:63 Amps, rated short circuit current capacity 10 KA rated frequency : 50 Hz, AC conforming to IS:60898-1/2002. 10 No.- Single pole MCB 16 Amps, 'C' curve, 10 KA, ISI marked conforming to IS/IEC 60898-1-2002.

2

23616

47233

... More
Supply, installation, Testing and Commissioning 16-meter long high mast lighting system complete with the following works:-1.1 Supply of 16-meter high mast system:- The mast shaft shall be in two sections hot dip galvanized inside and outside in single dip, suitable for wind velocity as per IS:875 part 3. There shall be only one longitudinal seam weld per section and no circumferential weld. It shall also include accessories for high mast including head frame, 2 point suspension system with stainless steel wire rope tralling cable, connector, 6 mm dia double drum winch, galvanized lantern carriage arrangement suitable for 08 luminaries LED type symmetrically arranged. The mast shall have an integral power tool motor, manual handle, junction box at the base compartment for its operation. 1.2 Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates & common template (Set 01) 1.3 Supply, fixing, testing and commissioning of LED flood light fixture 250 watt, power factor not less than 0.95 and LED driver should be constant voltage & current and fitting should be IP 66-08 Nos.LED fitting shall conform to BIS specification No. 10322 (Pt.5/sec. 1)/2012 or latest. 1.4 Supply of LED type single dome aviation obstruction light. 1.5 Design & making of outdoor stand mounted feeder pillar control panel with 63 Amps TPN MCB incomer, single dial time switch, 45 Amps TP contractor for the 25 automatic switching of luminaries, power tool control with 02 no. 9 Amps contractors and raise lower push button, incoming 35 mm & outgoing 16 & 2.5 mm2 terminals. (set 01) 2. Erection Part:-2.1 Design construction & erection of suitable shallow foundation with M20 concrete for the high mast considering the safe soil bearing capacity at site as 10 T/ sq.mtr at 2 mtr depth with all material & labour (Job-01) 2.2 Erection of the high mast with the help of suitable equipment and wiring of luminaries with all wiring material like PVC insulated, PVC sheathed flexible cable of suitable copper conductor, cable lugs, MCB etc and all labours. 2.3 Provision of G.I. pipe earthing arrangement for high mast with 4.5 M long 40 mm dia G.I. pipe including connection to high mast earth terminal with 25 x 3 mm G.I. earth strip with all materials and labour as per Drg. No. DRM/Elec./IZN/16-89 (Nos 02) 2.4 Installation, testing and commissioning of control panel on suitable foundation including all material & labour (Job 01).Note:-1. High mast system should be as per enclosed specification. Note:- Complete High Mast system with LED flood light shall be inspected by the RITES as per specification at the manufacture premises and inspection cost shall be borne by the contractor. (Successful Tenderer shall submit WARRANTEE GUARANTEE (WG) @ 10% of the Contract Value of this item in the prescribed proforma before claiming the payment for this item.) Note:- High Mast and LED flood light fixture 250 Watt shall be guaranteed/warranted for a period of 60 months from the date of commissioning for satisfactory performance.

2

395746

791493.36

... More
Making of hexagonal platform foundation with Rail post and including all accessories for high mast 26 lighting tower in in yard and goods siding as per CEE's Drg No. L/CEE/GKP/2010/2 as enclosed with all materials. Note: -1. Only rail pole will be supplied by the railway.2. Cutting of rail post 1750 mm length (each) is included in the scope of work.

2

10256

20512.48

... More
Supply, Fixing of distribution box in foundation, connecting testing and commissioning of LT distribution box made of 1.6 mm thick cold rolled steel sheet of size 600 mm (L) x 450 mm (W) x300 mm (D) with provision of water proof , hinged door, suitable locking arrangements, proper hole in the bottom for cable entry (incoming & out going cables) -05 Nos suitable and MS channel of size 75mm x 40mmx 4mm should be fixed across the panel for grouting on the foundation, earthing terminals and panel shall be powder coated (paint) 27 greenish grey shade with TPN Copper Busbar of 600 Amps with provision of water proofing and installation on Providing and making foundation to double door feeder pillar box (cubical type L.T. panel) in CC 1:2:4 with stare aggregate. [Size 1220 mm high x 800 mm length and 600 mm width (610 mm under the earth & 610 mm above the earth) with fine finish to exposed surface, two coats white washing including excavation of foundation, making proper size hole for incoming and outgoing cables. Grouting of holding down bolt in CC (size of bolt 150 mm long 16mm dia.) includes fixing of sub distribution box on CC foundation and as per direction of engineer in charge at site.

10

11658

116580

... More
Supply, erection and testing of hot dip galvanized tapered octagonal pole of 5.0 Mtrs. long top dia 28 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate dimension (L x B x T) 200 mm x 200 mm x 12 mm & foundation bolts size (No. x dia x length) (4 x M16 x 600 mm), PCD 200 mm, anchor plate thickness 3 mm with hot dip galvanized detachable double arm bracket made by 48.3 mm outer dia pipe 300 mm long with 32 mm outer dia sleeve including erection & fixing on the foundation. (Octagonal pole shall confirm to IS: 2629 or latest.) Note:-1. Galvanized thickness of pole should be minimum 65 microns and test report to be submitted by the contractor at the time of supply. 2. Octagonal pole shall have flush door arrangement and suitable size & length of cable connecting plate for incoming and outgoing cables as per standard.

30

7020

210609.9

... More
Making trench of size 300 mm x 300 mm x 1000 mm and Casting/grouting of pre-cast foundation CC 1:2:4 block size 300 mm x 300 mm x 1000 mm grouting with 20 mm size stone aggregate with cement & 29 coarse sand including supply, fixing and removing all firm work and finishing exposed surface including grouting and holding down-M 16x 450 mm- 4 Nos bolts in cement block as per requirement of pole base plate of size 200x200x12 mm and supply & fixing Double Walled Corrugated (DWC DPDE Duct Pipe, size 90/76 mm, confirming to IS:14930 (Part-II) 0.75 meter length in the centre of cement concrete block for cable entry and fixing properly with all labour, material, cement etc. complete in all respect as per direction of engineer in-charge at site.

30

1910

57312.3

... More
Fixing connecting testing and commissioning of LED street light fitting 90 watt and LED Flood light 30 on pole/ covered shed including supply and connection with twin core PVC insulated flexible copper conductor cable of size 1.5 sq.mm complete in all respect as per direction of engineer incharge at site. Note:-LED Flood light fitting will be supplied by railway at site.

60

81

4889.4

... More
Digging of trench in all kinds of soil up to the depth of 750 mm and 350 mm wide for laying of cable 31 with supply and placing of second-class bricks, approx. 10 bricks per meter, refilling of cable trench with solid earth consolidating by ramming by 270 mm above the surrounding level over trench. (Digging of trench conforming to IS 1255).

1500

49

74205

... More
Laying of XLPE (LT) cable of different sizes in excavated cable trench and in underground pipes. (Laying of cable conforming to IS: 1255).

2500

5

14375

... More
Supply, making testing & commissioning of pipe earthing arrangement with GI pipe 'B' class, 40 33 mm dia 4.50 mtrs, long including accessories & providing masonry enclosure with cover plate of 16 SWG M.S. having locking arrangement watering pipe , salt , charcoal etc. as per Drg. NO. DRM / Elect/IZN /16-89 to achieve earth resistance less than 10 ohms and connecting the equipment with 6 SWG G.I. wire as per site requirement. Earthing shall be done on the basis of code of practice for earthing as per IS: 3043/1987.

10

1375

13759.6

... More
All work pertaining to Horizontal Directional Drilling (HDD)/Boring and trench less cabling. It includes supply, transportation and insertion of self-lubricated HDPE pipe and laying of cable in boring under the 34 track/road by using different sizes of pipes depending on total number of cables will be crossed. The depth of horizontal boring should be 3 mtrs from rail flange/road level. This item will be used for track crossing of running lines.) By using self-lubricated HDPE pipe of 108.60 mm inner dia and 125 mm outer dia (PN-6) as per IS:4984 or latest in the bore and the laying of cables in the track/road.

70

1066

74622.1



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.