Minor Irrigation Department Tender
View complete overview of Uttarakhand Minor Irrigation Department Tender
Minor Irrigation Department Tender
Civil And Construction
Building Construction
Eprocure
Opening Date28 Feb 2024
Closing Date12 Mar 2024
Tender Amount₹ 59,05,000
Costs
EMD
₹ 1,18,100Document Cost
₹ 4,720Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MI_70486_1Bid Award Id
ViewTender No
01/EEMIUSN/2023-24Tender Authority
Minor Irrigation Department ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
B/Work F.P.S. brick of class designation 75 in super structure with 1:6 cement and sand mortar including all cost of material labour T&P etc for proper complition of work.
60.35
-
-
Providing and laying in position specified grade of reinforcement cement concrete excluding the cost of centering , shuttering finishing and reiforcement all work upto plinth with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)for Columns footing .
27.65
-
-
Reinforcement cement concrete work in wall ( Any Thickness) including attached Pilasters, butteresses, plinth, and string course fillet columns, posts, and struts etc, upto floor five level excluding cost of shuttering, centring, finishing and reinforcement1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)for Columns
9.4
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size).
46.89
-
-
Centring and shuttering including shutterings , ropng , etc and removel from foundation footing bases of columns.
12
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
167.14
-
-
Centering and shuttering including shuttering ropping etc. and removel from columns piller piers abutments, post and struts.
100.08
-
-
Suspended floors, roofs, landings, balconies and access platform.
284.65
-
-
12 mm thick cement plaster 1:6 cement & sand mortar including supply of all labour material andT&P etc required for proper complition of work.
335.75
-
-
15 mm thick cement plaster 1:6 cement & sand mortar on rough side including supply of all labour material andT&P etc required for proper complition of work.
335.75
-
-
Reinforcement for R.C.C. work including straightening, cutting , bending, placing, in postion and binding all comlete for Thermo Mechanically treated bars.
98.84
-
-
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coatof approved steel primer after pre-treatment of the surface as directedby Engineer-in-charge:
216.6
-
-
Steel work welded in built up Section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc.as required in gratings, framed, guard bar, ladder, relling and gate.
7.72
-
-
Providing and fixing of ISI marked 35 mm thick flush door shutter Confirming to IS:2202 (Part-1) decorative bord construction with frame of Ist class hard wood and well matched commercial 3 ply venering with vertical grain or cross band face veneers on both face of shutter.
24.26
-
-
Providing and fixing aluminium sliding door bolts ISI marked anodi coating not less than grade AC 10 as per IS : 1868) transparent or colour or shade with nuts and screws etc. complete
24
-
-
Providing and fixing aluminium hanging floor door stopper ISI mar (anodic coating not less than grade AC 10 as per IS : 1868) transp required colour and shade with necessary screws etc. complete.
12
-
-
Providing and fixing aluminium handles ISI marked anodised (anod less than grade AC 10 as per IS : 1868) transparent or dyed to req shade with necessary screws etc. complete :
12
-
-
Providing and fixing aluminium tower bolts ISI marked anodised (a not less than grade AC 10 as per IS : 1868 ) transparent or dyed t or shade with necessary screws etc. complete
12
-
-
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand anmanifactured.
32.64
-
-
Providing and applying plaster of peris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
956.15
-
-
Finishing wall with textured exterior paint of required shade with two and more coat applied @3.28ltr/10 Sqm over and including base coat of water proofing cement paint applied 2.20 Kg/10Sqm.
292.44
-
-
Distemring with Ist Qualiti Oil Bond washable distemper of approved brand and manufactur to give an even shade.
663.71
-
-
Providing and laying vitrified floor tiles in different sizes (thickness by the manufacturer) with water absorption’s less than 0.08% and IS : 15622 of approved make in all colours and shades, laid on 20 mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints
175.58
-
-
B/Work F.P.S. brick of class designation 75 in foundation and plinth with 1:4 cement and sand mortar including all cost of material labour T&P etc for proper complition of work.
8.8
-
-
4.0 cm thick cement conrete flooring 1:2:4 cement coarse sand and 20 mm aggregate finished with a floting coat of neat cement including cement sullary but excluding the cost of nosing of teps etc.
53.76
-
-
Providing and fixing Ist quality ceramick glazed floor tile 300x300 mm mm tiles confirming to IS: 15622 of approved make in all colour shade except burgundy, bottal green black of any size as approved by Engineer in charge with 1:4 cement and sand mortar I/C all.
22.68
-
-
Providing and fixing Ist quality ceramick glazed wall tile mm tiles confirming to IS: 15622 of approved make in all colour shade except burgundy, bottal green black of any size as approved by Engineer in charge with 1:3 cement and sand mortar I/C all.
54.9
-
-
20 mm cement plaster 1:3 finished with a floating coat of neat cement in Dado including all cost of labour material T&P etc for proper complition of work.
32.25
-
-
Providing and fixing of white vitreous china wash basin size 630x450 mm with C.I. brackets , 15 mm C.P. brass piller taps, 32 mm C.P. brass waste of standerd patterns including all fittings.
3
-
-
Providing and fixing water closed squatting pans (Indian type W.C. Pan) with 110 mm sand cast iron P or S trap 10 ltr loe level whte P.V.C. flushing cistern with manually controled divce confirming to IS :7231 with all fittings and fixtures complete including all cutting and making good the walls and floor wherever required
5
-
-
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automaticflushing cistern
4
-
-
S/F 15 mm Ø G.I. pipe line complete with G.I. fitting and clamp including supply of all material labour T&P etc.
15
-
-
S/F 20 mm Ø G.I. pipe line complete with G.I. fitting and clamp including supply of all material labour T&P etc.
30
-
-
S/F 15 mm Ø C.P. brass bib cock including all material labour T&P etc required for proper complition of work
7
-
-
S/F 15 mm Ø C.P. brass bib cock including all material labour T&P etc required for proper complition of work
7
-
-
Providing and placing on terrace (at all floor levels) polyethylene w tank ISI : 12701 marked with cover and suitable locking arrangem necessary holes for inlet, outlet and overflow pipes but without fitti base support for tank
500
-
-
Filling available excavated earth (excluding rock) in trenches, plin sides of foundations etc. in layers not exceeding 20cm in de consolidating each deposited layer by ramming and watering, up to 50 m and lift upto 1.5 m.
137.97
-
-
S/Filling in plinth of local sand under the floor including watering ramming consolidation & dressing Complete
34.49
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water conforming to IS : 13592 Type A including jointing with seal ring c 5382 leaving 10 mm gap for thermal expansion, (i) Single sockete
25
-
-
Half brick masonry with F.P.S. bricks of class designation 75 in superstructure abov plinth level upto floor V level in 1:4
31.72
-
-
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks).
31.72
-
-
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools,plants & machineries required for the job, all complete as per directionof Engineer-in-charge, upto 90 metre depth below ground level
40
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes
35
-
-
Providing and fixing of 4.00 m long PVC stainer with clamp including supply of all labour material T&P required for proper complition of work
4
-
-
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge
40
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
59
-
-
Providing and fixing of 2 H.P. electrical pump including supply of all material T&P required for proper complition of work.
1
-
-
Providing and fixing of Electrical Accissories for starter covered with suitable box including all for proper complition of work.
1
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor
single core cable etc. as required.
52
-
-
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch,
modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
6
-
-
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS
PVC insulated copper conductor single core cable for loopearthing as required.
120
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2x2.5 Sqmm+1x2.5 Sqmm eatrh wire
100
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4x4 Sqmm+2x4 Sqmm earth wire
30
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4x6 sqmm+2x 6sqmm earth wire
30
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
300
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
102
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amp switch
80
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
80
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
14
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providingand fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
40
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and
15/16 A modular switch, connections etc. as required.
60
-
-
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
40
-
-
Supplying and fixing brass batten/ angle holder including connections etc. as required.
60
-
-
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and earthing etc. as required.
20
-
-
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
14
-
-
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
6
-
-
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
6
-
-
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holesin cubicle panel, making connections, etc. as required.
1
-
-
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 Amp
1
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.
as required. (But without MCB/RCCB/Isolator) 8 way Double Door
2
-
-
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
7
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
1
-
-
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut
bolt & spring washer spaced at 50 mm)
20
-
-
Supply of AC 230/250 volts 50 Hzenergy efficient ceilling fan with standard down rod blades 3 nos caps Model Captiva 50 1200 mm sweep etc complete in all aspects as per direction of Engineer in charge.
14
-
-
Supply of AC 230/250 volts 50 HZ exhaust fans including providing nuts bolts, mounting frames and other accessories etc. complete Modle- Ventil Air RS (Mark HAVELLS) 300 MM sweep 900 rmp complete in all aspects as per Direction of Engineer in Charge.
6
-
-
Supply and Fdixing of LED tube light 1200 mm 18 W 865 T8 IP 20 Lumen output -1600,6500 K ceilling mounted LED batten extruded aluminium heat sink provieded for efficient heat dessipation 7 & intergrated electronic driver (1x18 W LED double 6500 K) complete in all aspects as per direction of Engineer in Charge.
18
-
-
Supply of LED glass bulb B22 12 W 6000K /4000k/3000k, 230/250 volt,50 HZ ETC complete in all aspects as per direction of Engineer in Charge
20
-
-
Supply and Fixing of main panel with 1 incoming & 8 outgoiong 40 amps FP MCB with suitable busbar change over switch ammeter voltmeter indicating lamps etc complete in all respect.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements