Indo Tibetan Border Police Tender

View complete overview of Uttarakhand ITBP Tender

Indo Tibetan Border Police - ITBP Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date9 Oct 2024
Closing Date29 Oct 2024
Tender Amount₹ 98,06,619 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand).

46.82

-

-

... More
Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete :1:1.5:3 (1 Cement: 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)

28.36

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete.

178.92

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

10.18

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centring, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

7.05

-

-

... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars.

1690.69

-

-

... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : Second class Deodar ( Local Surahi) wood

1.11

-

-

... More
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked black enameled M.S. butt hinges with necessary screws ( screws should be of stainless steel and brand Magnum/ Nettle fold/ Amul) excluding, panelling which will be paid for separately, ( thickness of shutters should be 35 mm)- first class local wood ( Tita champa/ pine confirming IS- 399:1963 ( Weight of should be 545 kg/ M3) Note- The shutters should be confirming IS 1003 (part-2): 1994 35 mm thick first class local wood (deodar/ shushm).

12

-

-

... More
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to40 mm thick : first class local wood ( Tita champa/ pine) (i) Local wood panells should be fixed only with grooves but additional beading should be provided on both sides, stiles, rails and panels in door shutters shall be of the same species of timber. (ii) Lock rail of door shutters shall be so placed that its certerline is at aheight of 850 +55mm from the bottom of shutters, each door shutters shall be fixed to the frame with three hinges one at the center and other two at 200 mm from top and the bottom of the shutters. (iii) All door shutters shall be finished smooth with well planed faces and panels of shutters shall be flat and well sanded to a smooth and level surface. (Iv) In case of double leaved shutters the meeting of the stiles shall be rebated either splayed or square type. (v) Each window shutters shall be fixed to the frame with two

5.84

-

-

... More
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes pans of brand Modi float, Atul, Saint Gobain, Golden only. Weight of glass pan should be 10.00 kg/sqm. Including black enamelled ISI mark Butt hinges with nessessury screws. (screws should be of stainless steel and brand Magum/ Nettle fold/ Amul) First class local wood (deodar/shushm)- 35 mm thick.

13.23

-

-

... More
Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position : with second class local wood (deodar/shushm First class local wood (deodar/shushm)

1.43

-

-

... More
Providing and fixing wooden biding with iron screws and priming coat on unexposed surface complete . second class local wood (deodar/shushm)-50x12mm.

424.65

-

-

... More
Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately) :12 mm thick

98.99

-

-

... More
Providing and fixing Anodized aluminium sliding bolts with nut and screws 250x16 confirming to IS 2681-1979 of brand Classic/EPSA ISI/ DECOR/VENUS/Adersh/ Crown ( anodic coating not less than grade AC 10 as per IS : 1868) 250x10mm.

8

-

-

... More
Providing and fixing anodised aluminium tower bolts 200x10 mm confirming to IS 204 of brand confirming to IS 2681-1979 of brand Classic/EPSA ISI/ DECOR/VENUS/Adersh/ Crown ( anodic coating not less than grade AC 10 as per IS : 1868).

144

-

-

... More
Providing and fixing anodized aluminium handles 125mm IS 208 of brand Classic/EPSA ISI/ DECOR/VENUS/Adersh/ Crown ( anodic coating not less than grade AC 10 as per IS : 1868).

66

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes

3143.11

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.63 mm ( + 0.05 %), total coated thickness with zinc coating 120 gsm per sqm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

143.72

-

-

... More
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)

22.7

-

-

... More
Providing and Fixing GI pipes complete with GI fittings and clamps i/c cutting and making good the walls etc. Internal work- Exposed on wall 15mm dia nominal bore

26

-

-

... More
Providing and fixing CP brass long body bib cock 15mm dia of make Parko/Kingstone/Essco confirming to IS: 8931

12

-

-

... More
Providing and fixing CP Brass angle valve for basin mixer and geyser point 15mm dia of make Parko/ Kingstone/ Essco conforming to IS: 8931

6

-

-

... More
Providing and fixing White vitreous china pedestal type water closet (Indian type wc pan) with 100 mm sand cast iron P or S trap. 10 ltr. low level white PVC flushing cistern with manullly of make Hindware, preware/ Cera- standard quality with fitting and CI/MS brackets, standard make and oconfirming to IS: 7231 with fitting and fixers complete including cutting and making good the walls and floor

3

-

-

... More
Providing and fixing wash basin make Hindware, Perryware, Cera Standard quality size 550x400mm with CI/MS brackets, 15m CP brass piller taps, L&K, Kingstone, Renutrol, Hansa, including painting of fittings and brackets cutting and making good the wall wherever require

3

-

-

... More
Providing and fixing 600x450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with CP Brass screws and washers complete.

3

-

-

... More
Providing and fixing soil, waste and vent pipes 100 mm dia of hard drawn PVC make 100 mm dia hard drawn PVC pipe C

45

-

-

... More
Providing and applying plastering on walls 12 mm thick of mix 1:6 (1 Cement : coarse sand)

398.45

-

-

... More
Distempering with oil bound washable distemper of brand Asian, berger, Nerolac, Shalimar Tractor to give and even shade over new work two or more coats and including priming coat of cement primer .

204.06

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of APEX, Asian, Berger, Nerolac, Shalimar of required shade on New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).

194.39

-

-

... More
Applying priming coat : With ready mixed pink or Grey primer of Asian, Jonson & Nicolson, Nerolac

91.68

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

91.68

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI 12701 with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipe but without fittings and the base support for tank (Sintex, electroplast, star, Lotus or equivalent having valid ISI license

400

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a neet cement floating coat including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.

89.99

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622 of approved make, in all colors and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc, complete Size of tile 600 x 600 mm

9

-

-

... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make, in all colour, shades excepts burgundy, bottle green, black of any size as approved buy Engineer-in- Charge in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1Cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete

70.5

-

-

... More
BIO Digester tank with outer dimension of tank approx 1.2 m (L) x 0.8 M (H) specially digester double walled FRP with outer wall thickness 3-5 mm and inner wall thickness 3 mm and insulation filled between two FRP walls with liquid injected poly urethane foam of 100 mm with partition of 3.5 mm thickness and bacteria immunization sheet (Tank Volume 0.7 cum) along with following heating element of 80 watts as per DRDO specification including supervision. Inner dimension of Bio Digester wall be 1M x 0.7 X (Suitable for 7 to 10 person) including bacteria @ 300 per tank

1

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A

10

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.G

4

-

-

... More
Copper cercuit/submain Wiring in PVC condute (PVC condute shall be of supreme brand) wiring for submain wiring with 2x2.5 mm² FRLS PVC insulated, copper conductor, single core cable make L&T, Rallision, Havells, in recesed steel conduit as required with specification like maximum 4 nos of wires in one conduit to 20mm dia, green/ yellow copper earth wire to come to switch box, black insulated copper wire for neutral also to come to switch box and for one core cable red PVC insulated copper wire should be used whereas core cable red and blue PVC copper wire to be used, steel conduit should be fixed with respective size of Intillo Tech Support clamp of chilly fixed with screw of make Nettle fold/Amul/ Magnum including steel conduit fittings make Steel mark/AKG/BECx2.5 sqmm

90

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) :- 8 way, Double door

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.