Indian Institute Of Technology Tender
View complete overview of Uttarakhand IIT Tender
Indian Institute Of Technology - IIT Tender
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date1 Nov 2024
Closing Date27 Nov 2024
Tender Amount₹ 2,66,52,290
Costs
EMD
₹ 5,50,000Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_IITR_833362_1Tender No
IWD/DI/10MVA/108Tender Authority
Indian Institute Of Technology ViewPurchaser Address
-Website
http://https://www.iitr.ac.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
SITC of 33KV, 200-100/1-1-1 Amp, 0.2S/5P,15VA, CT with Junction Box as per required technical specifications complete in all respect as mentioned in the tender documents.
3
-
-
SITC of 33KV, 400-200/1-1-1 Amp, 0.2S/5P,15VA, CT with Junction Box as per required technical specifications complete in all respect as mentioned in the tender documents
3
-
-
Design the improved version PTs as per site requirement, considering previous trends related to the failure of PTs, manufacturing, transportation, and SITC of 03 nos. (33000/Ö3)/(110/Ö3)V, 50 Hz, single-phase, outdoor type, Dual-core, 0.5 / 3P Class and suitable burden of Potential Transformers (PTs) based on design calculation considering Smart non-linear damping resistor for mitigating the ferroresonance issue at site. Design calculations need to be provided by the contractor.PT with Junction Box
3
-
-
SITC of Control and relay panel for single transformer feeder as per required technical specifications complete in all respect as mentioned in the tender documents.
1
-
-
SITC of Control and relay panel for single Line feeder as per required technical specifications complete in all respect as mentioned in the tender documents.
1
-
-
SITC of 33KV, station class LA as per required technical specifications complete in all respect as mentioned in the tender documents.
3
-
-
SITC of 33KV, suitable Fuse set as per required technical specifications complete in all respect as mentioned in the tender documents.
1
-
-
SITC of 11KV 800-1250 Amp VCB Incomer, as per required technical specifications complete in all respect as mentioned in the tender documents. Compatible and integrating with existing SCADA system (ABB-Hitachi make).
1
-
-
SITC of 11KV 800-1250 Amp VCB Bus Coupler, as per required technical specifications complete in all respect as mentioned in the tender documents. Compatible and integrating with existing SCADA system (ABB-Hitachi make).
1
-
-
SITC of 11KV 630-1250 Amp VCB Outgoing, as per required technical specifications complete in all respect as mentioned in the tender documents. Compatible and integrating with existing SCADA system (ABB-Hitachi make).
4
-
-
Supply and laying of Copper conductor, XLPE insulated, Un-armoured, PVC sheathed cable, 1100V grade, 2 core 2.5 mm2 on existing cable tray with M.S. clamps etc. of suitable size or as directed by the Engineer-In-charge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor as required etc.
150
-
-
Supply and laying of Copper conductor, XLPE insulated, Un-armoured, PVC sheathed cable, 1100V grade, 4 core 2.5 mm2 on existing cable tray with M.S. clamps etc. of suitable size or as directed by the Engineer-In-charge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor as required etc.
200
-
-
Supply and laying of Copper conductor, XLPE insulated, Un-armoured, PVC sheathed cable, 1100V grade, 10 core 2.5 mm2 on existing cable tray with M.S. clamps etc. of suitable size or as directed by the Engineer-In-charge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor as required etc.
100
-
-
Supply and laying of Aluminium conductor, XLPE insulated, Armuored, PVC/XLPE sheathed cable, 11 KV, UE grade, 3 core 300 mm² at a depth of 1000 mm below ground level including excavation and refling the trench over a cushion of 100 mm thick sand alround and protected with burnt bricks on sides and on top as directed by the Engineer-Incharge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. The cable shall be laid by boring the road as required and compaction of soil & repairing of surface in prior shape shall be done properly.
300
-
-
Supply and laying of Aluminium conductor, XLPE insulated, Armuored, PVC/XLPE sheathed cable, 33 KV grade, 3 core 300 mm² at a depth of 1000 mm below ground level including excavation and refling the trench over a cushion of 100 mm thick sand alround and protected with burnt bricks on sides and on top as directed by the Engineer-Incharge, complete in all respects. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. The cable shall be laid by boring the road as required and compaction of soil & repairing of surface in prior shape shall be done properly.
50
-
-
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3 core 300 mm², XLPE aluminium conductor cable of 11 kV(UE) grade as required.
6
-
-
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3 core 300 mm², XLPE aluminium conductor cable of 11 kV(UE) grade as required.
6
-
-
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 3 core 240-300 mm², XLPE aluminium conductor cable of 33 kV grade as required.
2
-
-
Making earth point with boring 18 Mt. deep with 80 mm dia G.I. pipe “B” class ISI. The top pipe 6 mt. length will be duly holed across the pipe at a distance of 15 cm apart in 4 rows. The each joint should be welded/ Brazing, 30 cm x 30 cm CI / HDPE FRP chamber masonary housing complete as per direction of site in charge complete.
4
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure/ HDPE FRP Chamber with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
10
-
-
Supplying and laying 32 mm X 6 mm G.I strip as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.
600
-
-
Supplying and laying 50 mm X 5 mm Copper strip as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.
300
-
-
Supply of High Di-electric strenth Insulating Rubber Chequered mat upto 33 kV , size 1 mtr x 2 mtr x 3 mm thick.
8
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer all complete.
200
-
-
Providing Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)
4
-
-
12 mm Cement Plaster of Mix 1:6 ( 1 Cement : 6 Fine Sand)
20
-
-
Earth work in excavation in soft soil by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m.
8
-
-
Providing and laying in position cement concrete of 1:1.5:3 specified grade excluding the cost of centering and shuttering.
8
-
-
Providing and laying in position cement concrete of 1:4:8 specified grade excluding the cost of centering and shuttering.
8
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
200
-
-
Designing, execution and commissioning of the electrical panel room in R.C.C. framed structure as per direction of EIC which will including floor height 3.60 meters or as per site requirement complete in all respects.
50
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%