Indian Institute Of Technology Tender

View complete overview of Uttarakhand IIT Tender

Indian Institute Of Technology - IIT Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date12 Sep 2024
Closing Date5 Oct 2024
Tender Amount₹ 50,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level- 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) (derived from natural source)

5

45228

9045.75

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement- 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) ( derived from natural source)

5

54264

10852.95

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). ( derived from natural source)

5

57527

11505.5

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

15

5882

392.15

... More
Suspended floors, roofs, landings, balconies and access platform

100

92725

927.25

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

150

110460

736.4

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

150

144195

961.3

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. - Thermo-Mechanically Treated bars of grade Fe 500D or more

1500

161775

107.85

... More
Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand).

150

45067

300.45

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

50

3920

78.4

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:

-

-

-

... More
Cement mortar 1:4 (1 cement : 4 coarse sand)

5

36853

7370.65

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :

-

-

-

... More
Cement mortar 1:4 (1 cement : 4 coarse sand)

5

46721

9344.35

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.

-

-

-

... More
Cement mortar 1:3 (1 cement :3 coarse sand)

20

23010

1150.5

... More
Cement mortar 1:4 (1 cement :4 coarse sand)

30

33714

1123.8

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete

250

33425

133.7

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. - Hot finished welded type tubes

250

48600

194.4

... More
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.

-

-

-

... More
Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides

25

21117

844.7

... More
Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides

25

28338

1133.55

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes

-

-

-

... More
75 mm diameter

100

24880

248.8

... More
110 mm diameter

100

37740

377.4

... More
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

500

221

22.1

... More
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof

20

1742

87.1

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work

100

23515

235.15

... More
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:

-

-

-

... More
Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)

20

21813

1090.65

... More
Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm)

20

28323

1416.15

... More
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.

1000

338250

338.25

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge - Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

10

24342

2434.25

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.

10

35512

3551.25

... More
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. - In cement mortar

10

20602

2060.2

... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm

50

3670

73.4

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.

25

1366

54.65

... More
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.

500

131975

263.95

... More
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.

50

282

5.65

... More
Grading roof for water proofing treatment with Cement mortar 1:4 (1cement : 4 coarse sand)

2

30311

15155.6

... More
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge

-

-

-

... More
75mm average thickness

250

94500

378

... More
50mm average thickness

500

128175

256.35

... More
25 mm average thickness

500

63375

126.75

... More
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.

-

-

-

... More
Bars upto 12 mm diametre

500

4125

8.25

... More
Bars above 12 mm diametre

250

4112

16.45

... More
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge.- Upto and including 12mm dia.

250

35300

141.2

... More
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.

-

-

-

... More
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer

500

70600

141.2

... More
Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make

250

71300

285.2

... More
Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge.

100

38240

382.4

... More
Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge.

100

23690

236.9

... More
Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of “L” shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge.

50

45127

902.55

... More
Supplying and fixing 10 Gauge weld mesh of size 100mm x100 mm for floor/roof slab concrete screed over the micro beams as reinforcement. The weld mesh shall be fixed as per drawing

50

12737

254.75

... More
Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in- Charge. (The payment shall be made on the basis of actual weight of approved grout injected.)

-

-

-

... More
Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used) modified Cement slurry made with non shrink compound in concrete/RCC work

150

17895

119.3

... More
Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/RCC work.

500

62000

124

... More
Epoxy injection grout in concrete/RCC work of approved make

150

83010

553.4

... More
Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site and disposal of the same beyond the compound and cleaning the site in all respect as per direction of Engineer-in-Charge at all floor levels

480

9048

18.85

... More
MICRO CONCRETE- Providing and laying microconcrete a single component, cement-based material to which only the site-addition of clean water ( and approved graded coarse aggregates where specified) shall be permitted. The repair grout in the flowable consistency should achieve a compressive strength of not less than 8N/mm2 after 24 hours at 30°C. Most importantly, the cured micro concrete shall contain no metallic aggregates, or chlorides and shall be shrinkage compensated in the plastic state. The micro concrete shall have a coefficient of thermal expansion similar to that of the host concrete. thickness as per the drawing by consultant/ EIC on the designated area to the prepared slurry tight shuttering with proper shear connector and bonding agent where ever necessary, The micro concrete in the flowable consistency should achieve a compressive strength of 35 N/mm2 after 28 days at 30°C. The fresh wet density of microconcrete shall exceed 2100-2200 kg/m3 at 27°C. cost is inclusive of all including, suppling, laying,labour, mixing. water storage

9

637910

70878.99

... More
Removing the rising dampness in wall due by using the expansive aqua reactive water barrier and grouting system (Cico Polygrout or eqivalent) . the treatment process carried out by using 12 mm diametre nipple spacing 150 to 300 mm in the near DPC. the grouting processing will be carried out by special one component high pressure grouting pump after Removing old Plaster, applying and providing minimum two coats elastomeric polymer modified cementious and applying and providing protection Plaster

250

657517

2630.07

... More
Providing and applying two coats of SIKALASTIC-562 IN (DAVCO K10 POLYURETHANE PLUS) or equivalent of approved make with embedded fiber mesh of 40 gsm over a thoroughly prepared clean and sound surface of the drainage channel. A single coat of Sikafloor-133 W Primer (Florprime WB) water based EPOXY Primer shall be applied prior to the application of SIKALASTIC_562 IN (DAVCO K10 POLYURETHANE PLUS) over the surface finished at floor finishing level. The products shall be applied in strict accordance with the manufacturer's specification. Technical Properties : Elongation at Break :380% Tensile Strength 3 N/mm² Crack Bridging: 2 mm Adhesion to concrete 1.03 MPA

220

289751

1317.05

... More
P/A epoxy based zinc rich protective coating and primer for steel to prevent from corrosion.

220

6083

27.65

... More
P/A 15 mm thick (average thickness) polymer modifed mortar with dual shrinkage compensated, thixotropic high strength formulation for repair of spalling and damaged concrete in building super structure work.

215

295076

1372.45

... More
P/A 25 mm thick (average) polymer modifed mortar with dual shrinkage compensated, thixotropic high strength formulation for repair of spalling and damaged concrete in building super structure work.

210

457453

2178.35

... More
Providing mixing and applying 12 mm thick ready mix cement plaster of approved make as per specifications and directions of EIC.

150

56400

376

... More
Providing mixing and applying 15 mm thick ready mix cement plaster of approved make as per specifications and directions of EIC.

150

68250

455



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.