Indian Institute Of Technology Tender

View complete overview of Uttarakhand IIT Tender

Indian Institute Of Technology - IIT Tender

Works
Electrical and Electronics
Eprocure
Opening Date22 Apr 2022
Closing Date22 Apr 2022
Tender Amount₹ 4,47,19,092 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
County of Origin : Imorted

-

-

-

... More
Chilled Water Entering Temperature : 54 deg F

-

-

-

... More
Chilled Water Leaving Temperature : 44 deg F

-

-

-

... More
Evaporator Fouling Factor : 0.0005 FPS

-

-

-

... More
Chilled Water Flow Rtae : 552 USGPM

-

-

-

... More
Condenser Water Entering Temperature : 90 deg F

-

-

-

... More
Condenser Water Leaving Temperature : 97.5 deg F

-

-

-

... More
Condenser Water Flow Rate : 920 USGPM

-

-

-

... More
Condenser Fouling Factor : 0.001 FPS

-

-

-

... More
Refrigerant : R-134 a

-

-

-

... More
Maximum Allowable IKW at actual condItion : 0.65

-

-

-

... More
Minimum COP at AHRI/Eurovent Conditions @100% Load : 6.2

-

-

-

... More
Maximum Allowable IPLV : 0.37

-

-

-

... More
Maximum Allowable NPLV : 0.40

-

-

-

... More
Scope of Supply

-

-

-

... More
Each circuit shall contain minimum following

-

-

-

... More
1No.- Twin Screw compressor Semi hermetic complete with automatic capacity control, safety switches and controls etc. as per specifications.

-

-

-

... More
1 No.- Suitable capacity refrigerant cooled induction motor with class 'F' insulation suitable for operation on 415+ 10% volts, 50Hz, A.C. supply.

-

-

-

... More
1 No. VFD starter suitable for compressor motor complete with ammeter with CTs, over load protection, under voltage protection, protection against phase reversal & independent single phase preventor etc. complete as per specification

-

-

-

... More
1 No. - Matching shell and tube water cooled condenser of M.S. shell and integrally finned copper tubes.

-

-

-

... More
1 No. - Matching Flood Type shell and tube chiller of MS shell & and copper tubes.

-

-

-

... More
1 Lot- Refrigerant piping fittings, valves and accessories to interconnect compressor, condenser, chiller and electronic expansion valve, safety valves, angle valve, liqid line indicaiton etc.

-

-

-

... More
1 Set- Microprocessor based control panel complete with accessories as per specifications.

-

-

-

... More
Lot- Water flow switches at outlet of condenser and chiller, water drain and air purge valves where ever required.

-

-

-

... More
Lot- Suction line and chiller insulation with minimum 19mm thick polyvinyl nitnile rubber insulation complete as required.

-

-

-

... More
1 Set victaulic coupling for chiller and Condenser Water Connection

-

-

-

... More
Lot- Initial / first charge of refrigerant gas and compressor oil.

-

-

-

... More
Lot- Frame work for mounting the above condenser, chiller compressor and motor with base plate complete with anti-vibration pads/springs.

-

-

-

... More
Lot Interconnecting piping with valves duly insulated

-

-

-

... More
(1 W + 1 S)

2

-

3832030

... More
Intelligent Anti Fouling Condenser System/ Smart Automatic Tube Cleaning System

-

-

-

... More
SITC of INTELLIGENT ANTI FOULING CONDENSER SYSTEM/SMART AUTOMATIC TUBE CLEANING SYSTEM with Anti Fouling arrangement on chiller by automatic condenser cleaning Upto 4# Chillers Max, with a Common Skid for the required number of chillers in the plantroom. The system shall include IoT Ready, Industry 4.0 complaint device. The Panel should have minimum 7" Touch Screen Graphical HMI which will log the real time data related to chiller energy (KWH), Capacity (TR), Chiller Water Flow monitoring, Water Temperature profile on evaporator and condenser both and graphical representation of historic summary which shall be displayed on the Mobile App with unlimited user access on cloud based system. The data should also be retrieved in XL or PDF Format. The skid shall have IOT Panel, Injection/Collection pump, Motorized Valves & Fittings. Field Devices like Energy Mater, Flow Meter, Temp. Sensors shall be picked up from BMS/CPO Scope of Supply & Data shall be replicated from skid via Modbus protocol. The Common Skid piping, Ball Trap Size to suit chiller capacity requirement for the project.

1

-

1168822

... More
Condenser Water Pump Set

-

-

-

... More
Supply, erection, testing and commissioning of End Suction back pullout Condenser water pump set capable of delivering 920 USGPM of water against 24 Meter head each comprising of the following and complete as per specifications and as required.

-

-

-

... More
1 No.- end suction back pullout pump with minimum 75% efficiency.

-

-

-

... More
1 No. 22.0 KW TEFC squirrel cage induction motor with class 'F' insulation, 1500 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply. Motor efficiency shall be IE3.

-

-

-

... More
Lot- Mounting frame with Antivibration pads.

-

-

-

... More
(1 W + 1 S)

2

-

248731

... More
Primary Chilled Water Pump Set

-

-

-

... More
Supply, erection, testing and commissioning of End Suction back pullout Primary chilled water pump set capable of delivering 552 USGPM of water against 12 Meter head each comprising of the following and complete as per specifications and as required.

-

-

-

... More
1 No.- end suction back pullout pump with minimum 75% efficiency.

-

-

-

... More
1 No. 7.5 KW TEFC squirrel cage induction motor with class 'F' insulation, 1500 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply. Motor efficiency shall be IE3.

-

-

-

... More
Lot- closed cell cross linked ployethylene insulation of 32 mm thick on pump assembly, all joints shall be sealed. Insulation shall be done according to chilled water piping insulation.

-

-

-

... More
Lot- Mounting frame with Anti-vibration pads.

-

-

-

... More
(1 W + 1 S)

2

-

160499

... More
Variable Secondary Pumping System

-

-

-

... More
Installing, testing and commissioning of variable speed pumping system consisting of Adjustable Frequency Drive (AFD) for each pump, one dedicated microprocessor based Stand Alone Pump Controller housed inside a control cabinet or independently with parallel pumping software duly downloaded and single/ multiple differential pressure sensor/ transmitters as per the site requirement. The entire system alongwith secondary pumps of end suction back pullout Secondary Chilled Water pump set capable of following parameter and complete as per specification and requirement of pump and VFD (it must be sourced from single manufacturer only) to ensure unit responsibility. Necessary factory test certificate for entire system shall be submitted alongwith the equipment. The stand alone pump controller shall be suitable for taking analog inputs from 05 Nos. Sensor/ transmitter. The system shall comprise of the following:

-

-

-

... More
1 No.-End Suction back pullout Secondary chilled water pump set capable of delivering 552 USGPM of water against 32 Meter head each comprising of the following and complete as per specifications and as required.

-

-

-

... More
1 No.- end suction back pullout pump with minimum 75% efficiency.

-

-

-

... More
1 No. 18.0 KW TEFC squirrel cage induction motor with class 'F' insulation 1500 rpm synchronous speed, operating on 415+ 10% volts, 3 phase, 50 Hz A.C. supply. Motor efficiency shall be IE3.

-

-

-

... More
Lot- Mounting frame with Anivibration pads.

-

-

-

... More
Lot- closed cell cross linked ployethylene insulation of 32 mm thick on pump assembly, all joints shall be sealed. Insulation shall be done according to chilled water piping insulation.

-

-

-

... More
(1 W + 1 S)

2

-

350647

... More
Electric Hot Water Generator

-

-

-

... More
Supply, Installation, Testing and commissioning of package type BMS compatiable electric Hot Water Generator with M.S. shell, heater, electric control panel, controls, safety controls, pressure guages, thermometer, insulation complete with fittings and accessories as per specifications and drawings including foundation and all necessary civil work.

-

-

-

... More
Water Temperature 'IN' : 45oC

-

-

-

... More
Water Temperature 'OUT' : 50oC

-

-

-

... More
Lot- Water flow switches at outlet, water drain and air purge valves where ever required.

-

-

-

... More
No. of Heater Banks '3'

-

-

-

... More
Capacity of Each Heater Bank '30 KW'

-

-

-

... More
120 KW (30 KW x 4 Nos.-Part Standby)

1

-

178174

... More
Cooling Tower

-

-

-

... More
Supplying, installation, testing and commissioning of CTI certified FRP cooling tower of 8,76,960 K.Cal/Hr heat rejection capacity in single cell construction with FRP water basin, PVC fills with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, statically and dynamically balanced axial flow type fan-direct driven or driven through reduction gear box with TEFC induction motor, suction screen, make up-quick fill arrangement, overflow and drain connections with necessary valves and suitable inspection ladder, access arrangement for cooling tower interior, cement concrete foundation, steel / masonry supporting structure, anti-vibration mountings, complete as per specifications and as required. Motor efficiency shall be IE3.

-

-

-

... More
Water Flow Rate : 920 USGPM

-

-

-

... More
Cooling Tower Entering Water Temperature : 97.5 deg F

-

-

-

... More
Cooling Tower Leaving Water Temperature : 90.0 deg F

-

-

-

... More
Wet Bulb Tempreture : 83.0 deg F

-

-

-

... More
Fan Motor : 2x 5.5 KW

-

-

-

... More
(1 W + 1S) .

2

-

391983

... More
Ceiling Suspended Treated Fresh Air Handling Unit (TFAHU)

-

-

-

... More
AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside & 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 & Filter Bypass leakge F9.

-

-

-

... More
Pre-Filter section: - It should consist of pre-filters. Pre-filters section shall be with non-woven synthetic media down to 10 micron particle size with an efficiency of 90% (MERV-8) as per ASHRAE Standard-52.2 -2017.

-

-

-

... More
Fine-Filter section: - It should consist of fine-filters. Fine-filters section shall be with non-woven synthetic media down to 5 micron particle size with an efficiency of 95% (MERV-13) as per ASHRAE Standard-52.2 -2017.

-

-

-

... More
Cooling Coil: - COIL- Copper tubes and Aluminium fins 10-12 fin /inch and Copper Header, Coil size shall be selected for air velocity of 500 ft/minute & velocity across filters at 500 ft/minute. Water side pressure drop should not exceep 10PSIG. Selection should be made through Eurovent certified selection software.

-

-

-

... More
Fan and Motors: - AHU must have Airfoil design Plug type centrifugal Fan with IE3 energy efficiency mototr. Fan motors shall be energy efficient with IE-3 grade and shall be 415±10% volts, 50 cycles, three phases, totally enclosed fan-cooled class F, with IP-55 protection. Motors shall be especially designed for quiet operation. Drive to fan shall be provided through Direct drive arrangement. Frequency converter (VFD) for energy saving & smooth regulation of air flow, shall be supplied by the AHU manufacturer for all AHUs with direct driven plug fans. Fans impeller shall be selected for minimum efficiency of 70%. Plug fans in fan array shall have individual VFDs for every motor fan set. Certified Computerized selection for AHU shall be with fan selection and sound level spectrum. Complete AHU sound level should be given in computerized selection sheet instead of sound level of bare fan.

-

-

-

... More
Accessories: LED light with cable; view port and cable gland should provide in fan sections by manufacturer (to protect further leakage).

-

-

-

... More
AHU sound pressure level should be not be more than 65 db(A) at the distance of 1m from the unit.

-

-

-

... More
Unit Should have: MERV-8 filter sections, MERV-13 filter sections, Coil section, Fan section.

-

-

-

... More
UV Lams shall be installed in each AHU and the desity of UV light should be as required to kill Medium of COVID-19 virus as per ASHRAE Guidelines.

-

-

-

... More
Total static pressure of AHU & row deep of cooling coil shall be checked by Vendor as mention blow.

-

-

-

... More
TFAHU 01 - Design For -Ground Floor

-

-

-

... More
Cooling Capacity ( TR ) : 12.0

-

-

-

... More
Dehumidified Air (CFM) : 1550

-

-

-

... More
Cooling Coil Row Deep : 8

-

-

-

... More
Static (MMWC) : 75

-

-

-

... More
Motor KW : 1.5 KW (Vendor has to confirm power requirement after selection)

2

-

78397

... More
TFAHU 02 - Design For -First Floor

-

-

-

... More
Cooling Capacity ( TR ) : 19.5

-

-

-

... More
Dehumidified Air (CFM) : 2500

-

-

-

... More
Cooling Coil Row Deep : 8

-

-

-

... More
Static (MMWC) : 75

-

-

-

... More
Motor KW : 2.2 KW (Vendor has to confirm power requirement after selection)

1

-

92654

... More
TFAHU 03 - Design For -First Floor

-

-

-

... More
Cooling Capacity ( TR ) : 8.5

-

-

-

... More
Dehumidified Air (CFM) : 1100

-

-

-

... More
Cooling Coil Row Deep : 8

-

-

-

... More
Static (MMWC) : 75

-

-

-

... More
Motor KW : 1.1 KW (Vendor has to confirm power requirement after selection)

1

-

64143

... More
TFAHU 04 - Design For -Second Floor

-

-

-

... More
Cooling Capacity ( TR ) : 4.0

-

-

-

... More
Dehumidified Air (CFM) : 500

-

-

-

... More
Cooling Coil Row Deep : 8

-

-

-

... More
Static (MMWC) : 75

-

-

-

... More
Motor KW : 0.55 KW (Vendor has to confirm power requirement after selection)

1

-

35635

... More
Ceiling Suspended Air Handling Unit

-

-

-

... More
AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside & 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 & Filter Bypass leakge F9.

-

-

-

... More
Pre-Filter section: - It should consist of pre-filters. Pre-filters section shall be with non-woven synthetic media down to 10 micron particle size with an efficiency of 90% (MERV-8) as per ASHRAE Standard-52.2 -2017.

-

-

-

... More
Cooling Coil: - COIL- Copper tubes and Aluminium fins 10-12 fin /inch and Copper Header, Coil size shall be selected for air velocity of 500 ft/minute & velocity across filters at 500 ft/minute. Water side pressure drop should not exceep 10PSIG. Selection should be made through Eurovent certified selection software.

-

-

-

... More
Fan and Motors: - AHU must have Airfoil design Plug type centrifugal Fan with IE3 energy efficiency mototr. Fan motors shall be energy efficient with IE-3 grade and shall be 415±10% volts, 50 cycles, three phases, totally enclosed fan-cooled class F, with IP-55 protection. Motors shall be especially designed for quiet operation. Drive to fan shall be provided through Direct drive arrangement. Frequency converter (VFD) for energy saving & smooth regulation of air flow, shall be supplied by the AHU manufacturer for all AHUs with direct driven plug fans. Fans impeller shall be selected for minimum efficiency of 70%. Plug fans in fan array shall have individual VFDs for every motor fan set. Certified Computerized selection for AHU shall be with fan selection and sound level spectrum. Complete AHU sound level should be given in computerized selection sheet instead of sound level of bare fan.

-

-

-

... More
Accessories: LED light with cable; view port and cable gland should provide in fan sections by manufacturer (to protect further leakage).

-

-

-

... More
AHU sound pressure level should be not be more than 65 db(A) at the distance of 1m from the unit.

-

-

-

... More
Unit Should have: MERV-8 filter sections, Coil section, Fan section.

-

-

-

... More
UV Lams shall be installed in each AHU and the desity of UV light should be as required to kill Medium of COVID-19 virus as per ASHRAE Guidelines.

-

-

-

... More
Total static pressure of AHU & row deep of cooling coil shall be checked by Vendor as mention blow.

-

-

-

... More
CSAHU 01 - Design For -Ground Floor

-

-

-

... More
Cooling Capacity ( TR ) : 7.0

-

-

-

... More
Dehumidified Air (CFM) : 4000

-

-

-

... More
Cooling Coil Row Deep : 6

-

-

-

... More
Static (MMWC) : 40

-

-

-

... More
Motor KW : 2.2 KW (Vendor has to confirm power requirement after selection)

1

-

114031

... More
CSAHU 02/03 - Design For -Ground Floor

-

-

-

... More
Cooling Capacity ( TR ) : 4.0

-

-

-

... More
Dehumidified Air (CFM) : 2000

-

-

-

... More
Cooling Coil Row Deep : 4

-

-

-

... More
Static (MMWC) : 40

-

-

-

... More
Motor KW : 1.1 KW (Vendor has to confirm power requirement after selection)

2

-

57016

... More
CSAHU 04/05 - Design For -Ground Floor

-

-

-

... More
Cooling Capacity ( TR ) : 4.0

-

-

-

... More
Dehumidified Air (CFM) : 1600

-

-

-

... More
Cooling Coil Row Deep : 4

-

-

-

... More
Static (MMWC) : 40

-

-

-

... More
Motor KW : 1.1 KW (Vendor has to confirm power requirement after selection)

2

-

49889

... More
CSAHU 06/07 - Design For -Ground Floor

-

-

-

... More
Cooling Capacity ( TR ) : 3.0

-

-

-

... More
Dehumidified Air (CFM) : 1600

-

-

-

... More
Cooling Coil Row Deep : 4

-

-

-

... More
Static (MMWC) : 40

-

-

-

... More
Motor KW : 1.1 KW (Vendor has to confirm power requirement after selection)

2

-

49889

... More
CSAHU 01 - Design For -First Floor

-

-

-

... More
Cooling Capacity ( TR ) : 7.0

-

-

-

... More
Dehumidified Air (CFM) : 4000

-

-

-

... More
Cooling Coil Row Deep : 6

-

-

-

... More
Static (MMWC) : 40

-

-

-

... More
Motor KW : 2.2 KW (Vendor has to confirm power requirement after selection)

1

-

114031

... More
CSAHU 02 - Design For -First Floor

-

-

-

... More
Cooling Capacity ( TR ) : 6.0

-

-

-

... More
Dehumidified Air (CFM) : 3500

-

-

-

... More
Cooling Coil Row Deep : 6

-

-

-

... More
Static (MMWC) : 40

-

-

-

... More
Motor KW : 1.5 KW (Vendor has to confirm power requirement after selection)

1

-

99777

... More
CSAHU 03/04 - Design For -First Floor

-

-

-

... More
Cooling Capacity ( TR ) : 5.0

-

-

-

... More
Dehumidified Air (CFM) : 3000

-

-

-

... More
Cooling Coil Row Deep : 6

-

-

-

... More
Static (MMWC) : 40

-

-

-

... More
Motor KW : 1.5 KW (Vendor has to confirm power requirement after selection)

2

-

85524

... More
CSAHU 01 - Design For -Second Floor

-

-

-

... More
Cooling Capacity ( TR ) : 7.0

-

-

-

... More
Dehumidified Air (CFM) : 3750

-

-

-

... More
Cooling Coil Row Deep : 6

-

-

-

... More
Static (MMWC) : 40

-

-

-

... More
Motor KW : 2.2 KW (Vendor has to confirm power requirement after selection)

1

-

106904

... More
Floor Mounted Air Handling Unit

-

-

-

... More
AHU Construction: - It shall be made from 0.8 mm pre-plasticized/pre -coated Galvanised steel sheet outside & 0.8 mm plain G.S.S inside of 275 GSM. It shall be 40mm thick PUF insulation factory injected between them by injection moulding m/c, with density not less than 42 kg/Cum between them. Drain pan made out of Stainless steel (SS Grade 304) sheet. All AHU should be with thermal brake profile. AHU must confirm to Eurovent standard EN 1886 and certified for Casing Air Leakage L1, Casing Strength D1, Thermal Brdiging TB2, Thermal Transmittance T2 & Filter Bypass leakge F9.

-

-

-

... More
Pre-Filter section: - It should consist of pre-filters. Pre-filters section shall be with non-woven synthetic media down to 10 micron particle size with an efficiency of 90% (MERV-8) as per ASHRAE Standard-52.2 -2017.

-

-

-

... More
Fine-Filter section: - It should consist of fine-filters. Fine-filters section shall be with non-woven synthetic media down to 5 micron particle size with an efficiency of 95% (MERV-13) as per ASHRAE Standard-52.2 -2017.

-

-

-

... More
Cooling Coil: - COIL- Copper tubes and Aluminium fins 10-12 fin /inch and Copper Header, Coil size shall be selected for air velocity of 500 ft/minute & velocity across filters at 500 ft/minute. Water side pressure drop should not exceep 10PSIG. Selection should be made through Eurovent certified selection software.

-

-

-

... More
Fan and Motors: - AHU must have Airfoil design Plug type centrifugal Fan with IE3 energy efficiency mototr. Fan motors shall be energy efficient with IE-3 grade and shall be 415±10% volts, 50 cycles, three phases, totally enclosed fan-cooled class F, with IP-55 protection. Motors shall be especially designed for quiet operation. Drive to fan shall be provided through Direct drive arrangement. Frequency converter (VFD) for energy saving & smooth regulation of air flow, shall be supplied by the AHU manufacturer for all AHUs with direct driven plug fans. Fans impeller shall be selected for minimum efficiency of 70%. Plug fans in fan array shall have individual VFDs for every motor fan set. Certified Computerized selection for AHU shall be with fan selection and sound level spectrum. Complete AHU sound level should be given in computerized selection sheet instead of sound level of bare fan.

-

-

-

... More
Accessories: LED light with cable; view port and cable gland should provide in fan sections by manufacturer (to protect further leakage).

-

-

-

... More
AHU sound pressure level should be not be more than 65 db(A) at the distance of 1m from the unit.

-

-

-

... More
Unit Should have: MERV-8 filter sections, MERV-13 filter sections, Coil section, Fan section.

-

-

-

... More
UV Lams shall be installed in each AHU and the desity of UV light should be as required to kill Medium of COVID-19 virus as per ASHRAE Guidelines.

-

-

-

... More
Total static pressure of AHU & row deep of cooling coil shall be checked by Vendor as mention blow.

-

-

-

... More
AHU 01 - Design For -Second Floor

-

-

-

... More
Cooling Capacity ( TR ) : 20.0

-

-

-

... More
Dehumidified Air (CFM) : 12000

-

-

-

... More
Cooling Coil Row Deep : 6

-

-

-

... More
Static (MMWC) : 75

-

-

-

... More
Motor KW : 7.5 KW (Vendor has to confirm power requirement after selection)

1

-

363475

... More
Hydonic Cassette Unit (HCU)

-

-

-

... More
Supply, installation, testing and commissioning of ceiling suspended Cassette type Unit complete with casing, filter, cooling coil & multiblade centrifugal direct driven fan (three speed) with TEFC motor of class 'F' insulation, operated on 230 volts, single phase, 50Hz, AC supply, external decorative grill/panel, inbuilt drain pump, electrical & control copper cabling from nearest power point complete as required and as per specification of following capacities :

-

-

-

... More
1.0 TR, 400 CFM with 2 Row Cooling Coils

9

-

21381

... More
1.5 TR, 600 CFM with 2 Row Cooling Coils

14

-

25657

... More
2.0 TR, 800 CFM with 2 Row Cooling Coils

13

-

31359

... More
2.5 TR, 1000 CFM with 2 Row Cooling Coils

6

-

35635

... More
3.0 TR, 1200 CFM with 2 Row Cooling Coils

8

-

39911

... More
3.5 TR, 1400 CFM with 2 Row Cooling Coils

8

-

42762

... More
4.0 TR, 1600 CFM with 2 Row Cooling Coils

12

-

45613

... More
Fan Coil Unit (FCU)

-

-

-

... More
Supply, Installation ,testing and commissioning of fan coil units having following capacities, ceiling mounted complete with insulated body, coil section having chilled water cooling coils with mechanically bonded aluminium fins - dry metallic / synthetic washable fitter, cordless remote, insulated S.S.. drain pan, drain connection, blower,TEFC slow speed ( 3 speed ) squirrel cage induction motor suitable for operation on 230 volts, single phase .50 Hz, A.C. supply.

-

-

-

... More
4.0 TR, 1600 CFM with 3 Row Cooling Coils

24

-

29933

... More
Split AC Units

-

-

-

... More
SITC of 1.8-2.2 TR Inverter Split type AC 5 Star Rating and remote control with required MS Stands for fixing the outdoor units including 3 Meters copper kit complete in all respects.

-

-

-

... More
1.8-2.2 TR Inverter Split type AC 5 Star Rating

1

-

60122

... More
Tube Axial Flow Fans for Emergency Mode (Fresh Air/Exhaust Air)

-

-

-

... More
Supply, installation, testing and commissioning of tube axial flow fans complete with TEFC motor, F/H-Class insulation, mounting arrangement, G.I. Welded wiremesh inlet guard, back draft gravity dampers, vibration isolator etc. complete in all respect as per specifications and drawings. The fans should be AMCA certified for air performance & sound ratings and the fan should be selected for maximum efficiency.

-

-

-

... More
Note :

-

-

-

... More
a) All motor shall be IE3 and F/H-Class insulation

-

-

-

... More
b) Fan motor speed shall not exceed 1450 RPM

-

-

-

... More
c) Fan outlet Velocity shall not exceed 18.6 m/s.

-

-

-

... More
d) Factory fitted motorised dampers and all accessories shall be part of the Tube Axial Fan

-

-

-

... More
e) All Exaust Fans shall be fire rated for 250 deg C for two hours in accordance to BSEN12101-3:2015 standard.

-

-

-

... More
FIRST Floor

-

-

-

... More
14500 CFM @ 20 MMWG SP, 5.5 KW Motor for Emergency Supply

6

-

82673

... More
THIRD Floor

-

-

-

... More
29000 CFM @ 25 MMWG SP, 11.0 KW Motor for Emergency Exhaust

3

-

135412

... More
HVAC Plant Room

-

-

-

... More
6000 CFM @ 20 MMWG SP, 2.2 KW Motor for HVAC Plant Room Exhaust

2

-

35635

... More
SUB HEAD 'B'-PLUMBING

-

-

-

... More
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation)

-

-

-

... More
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.

-

-

-

... More
150 mm dia.(32 mm thick insulation)

300

-

2915

... More
125 mm dia.(32 mm thick insulation)

45

-

2590

... More
100 mm dia.(32 mm thick insulation)

105

-

2061

... More
80 mm dia.(32 mm thick insulation)

120

-

1554

... More
65 mm dia.(32 mm thick insulation)

110

-

1247

... More
50 mm dia.(32 mm thick insulation)

265

-

1111

... More
40 mm dia.(32 mm thick insulation)

185

-

919

... More
32 mm dia.(19 mm thick insulation)

450

-

751

... More
25 mm dia.(19 mm thick insulation)

365

-

625

... More
20 mm dia.(19 mm thick insulation)

250

-

449

... More
Protective Coating Over The Exposed Chilled Water Piping Insulatio

-

-

-

... More
Supplying, laying/ fixing, testing and commissioning of all insulated chilled water pipe insulation shall be coated with STARBOND 30-36/MAGIK 30-36, UL Classified Anti-Fungal insulation protective coating in conjunction with 7mil non-combustible certified Parafab GFC woven fiber glass cloth, tested as per ASTM D 4804, ASTM E 84, ASTM D-5035-11, ASTM D 1777-64 and ASTM D 3776-09, finally finished with 2 layers of Insulation protective coating to provide complete seal against air and moisture/resistance against mechanical impact, scratch, weather resistance with the properties of mold, fungus and bacterial resistance. The coating shall be complied with UL 723 i.e. Surface flame spread should be 0 and smoke developed should be also 0, coating should also comply with NFPA 90A & 90B- 25/50 for parameter and the VOC level of the coating should comply with LEED IEQ 4.2 i.e. VOC level should be below than 50 gram/litter and it should also comply the guidelines of MIA 3316C- Class 1 & Grade A.

-

-

-

... More
FIBER GLASS CLOTH

280

-

78

... More
INSULATION COATING

185

-

178

... More
INSULATED VALVES

-

-

-

... More
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.

-

-

-

... More
Motorised Butter Fly Valves

-

-

-

... More
Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required.

-

-

-

... More
150 mm dia.

4

-

30479

... More
125 mm dia.

1

-

25554

... More
100 mm dia.

1

-

23735

... More
80 mm dia.

2

-

16423

... More
65 mm dia.

1

-

16110

... More
50 mm dia.

1

-

15811

... More
40 mm dia.

4

-

15811

... More
32 mm dia.

12

-

15811

... More
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified

-

-

-

... More
150 mm dia.

14

-

6565

... More
125 mm dia.

4

-

5861

... More
100 mm dia.

2

-

5169

... More
80 mm dia.

6

-

3691

... More
65 mm dia.

8

-

3436

... More
50 mm dia.

9

-

3167

... More
40 mm dia.

8

-

2925

... More
32 mm dia.

24

-

2540

... More
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.

-

-

-

... More
150 mm dia.

1

-

26600

... More
125 mm dia.

2

-

19996

... More
100 mm dia.

1

-

15223

... More
80 mm dia.

3

-

10360

... More
65 mm dia.

3

-

9058

... More
50 mm dia.

2

-

7379

... More
40 mm dia.

1

-

4522

... More
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified.

-

-

-

... More
150 mm dia.

4

-

8296

... More
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.

-

-

-

... More
150 mm dia.

4

-

14758

... More
65 mm dia.

1

-

6207

... More
50 mm dia.

1

-

5033

... More
40 mm dia.

4

-

3565

... More
32 mm dia.

12

-

1542

... More
Note: 32 mm shall be of forged brass and screwed connection.

-

-

-

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required

48

-

1094

... More
Providing & fixing in position the mercury in glass industrial type thermometers.

40

-

957

... More
Supply,installation,testing and commissioning of Autometic Air Vents .

-

-

-

30

-

1525

25

-

1924

... More
Pressure Independent Control Valve (PICV)

-

-

-

... More
Pressure independent control valve (PICV) complete with quick-fit pressure/temperature ports. Size DN 15 (from DN 32 to DN 50). Main connections 1/2” M (from 1/2” to 1 1/4”) (ISO 228-1). Dezincification resistant alloy body and headwork. Control stem, piston and springs in stainless steel. Pressure regulator diaphragm, obturator and seals in EPDM. Asbestos-free fibre seals. Pre-adjustment indicator in PA6G30. Knob in PA6. Maximum working pressure 25 bar. Maximum differential pressure with actuator code 145013 (and 6565 series) installed 5 bar. Working temperature range -20–120°C. Nominal Dp control range 25–400 kPa. Accuracy ± 5 % of the setpoint. Flow rate regulation range 0,02–0,2 m3/h (0,02–0,2 m3/h, 0,08–0,4 m3/h, 0,08–0,8 m3/h, 0,12–1,2 m3/h, 0,18–1,8 m3/h, 0,3–3 m3/h and 0,37–3,7 m3/h). The adjustment position does not affect the obturator stroke. Full stroke modulation. Flow rate pre-adjustment device with at least 10 reference positions and continuous adjustment. Leakage class V according to EN60534-4. Diaphragm pressure regulator. Complete with On - Off OR Modulating actuator

-

-

-

... More
65 mm dia pipe for AHUs

1

-

89087

... More
50 mm dia pipe for AHUs

1

-

84810

... More
40 mm dia pipe for AHUs

4

-

57016

... More
32 mm dia pipe for AHUs

12

-

34209

... More
FCU/HCU CAR KIT

-

-

-

... More
Supply,installation, testing & Commisioning of Connection and regulation kit for HVAC fan coil units / hydronic cassette unit in heating/ cooling systems. Complete with: pressure independent control valve with proportional linear actuator (Modulating type ), three-way shut-off valves, integrated by-pass, Venturi device with pressure test ports, shut off valve with strainer and shell insulation made of PPE. NOTE : all given parts should be of one single manufacturer,no different manufacturer assembelled unit is acceptable. Linear or equipotential flow rate adjustment characteristic, which can be set up by actuator depending on the characteristics of the terminal unit. Maximum working pressure 25 bar. Maximum differential pressure with actuator installed: 5 bar. Nominal operation Δp range 25–400 kPa. Working temperature range -10−120°C. Ambient temperature range 0−50°C. Strainer mesh size 800 µm. Dezincification resistant alloy body and adjustment headwork; stainless steel strainer mesh; EPDM diaphragm, obturator and seals. One pair of flexible connection with threaded nut / clamp to be provided between the unit and kit of suitable length.

-

-

-

... More
20 mm dia for HCU/FCU

42

-

24944

... More
25 mm dia for HCU/FCU

52

-

27795

... More
Expansion Tank (PVC-1000 Ltr.)

-

-

-

... More
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

1000

-

9.7

... More
Expansion Tank Insulation(19mm thick)

-

-

-

... More
Supplying , installation, testing & commissioning of external thermal insulation on tank with Duly laminated aluminum foil of mat finish Closed Cell Cross Linked Polyethylene (class “O”) insulation shall be 27 ± 3 Kg/m3. The product shall have temperature range of –40 oC to 105oC. Thermal Conductive not exceeding 0.033 W/mK at an average Temperature of 23°C. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6 : 1989 for fire propagation test and for Class 0 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability shall be not less than 0.024 per inch (2.48 x 10-14 Kg/m.s.Pa i.e. µ7000: Water vapour diffusion resistance).The Material shall have Fire Approval from CBRI - Roorkee

5

-

663

... More
Drain Piping

-

-

-

... More
Supply, Installation, testing and commissioning of 10 KG Presure PVC piping with 6 mm Nitrile insulation complete with fittings, supports accessories in surface/recess as per specifications & site requirments

-

-

-

... More
65 mm dia.

125

-

325

... More
50 mm dia.

85

-

270

... More
40 mm dia.

75

-

230

... More
32 mm dia.

100

-

180

... More
25 mm dia.

175

-

150

... More
20 mm dia.

200

-

120

... More
Supply,installation,testing and commissioning of 25 mm dia Ball valves for header and equipment drain with fittings etc.

52

-

838

... More
CONDENSER WATER PIPE

-

-

-

... More
Supplying, fixing, testing and commissioning of condenser water pipes of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends,tees etc.but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.

-

-

-

... More
200 mm dia.

80

-

3705

... More
150 mm dia.

30

-

2385

... More
125 mm dia.

6

-

2087

... More
100 mm dia.

15

-

1784

... More
80 mm dia.

15

-

1765

... More
50 mm dia.

20

-

1106

... More
VALVES WITHOUT INSULATION

-

-

-

... More
Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications.

-

-

-

... More
Supplying, fixing, testing and commissioning of following sizes Motorized Butter fly Valve with CI Body, SS Disc,O - ring and minimum PN-16 pressure rating , conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC , and upto 20mA electric signal and providing similar transduced feedback output to control system as required.

-

-

-

... More
200 mm dia.

4

-

51795

... More
BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified.

-

-

-

... More
200 mm dia.

16

-

11531

... More
150 mm dia.

4

-

5442

... More
125 mm dia.

1

-

4797

... More
100 mm dia.

2

-

4120

... More
80 mm dia.

2

-

3015

... More
50 mm dia.

2

-

2544

... More
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified.

-

-

-

... More
200 mm dia.

4

-

56827

... More
NON - RETURN VALVE with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified.

-

-

-

... More
200 mm dia.

2

-

12181

... More
M.S Y-Strainer Complete with Stainless Steel Bucket having 03 mm Perforation, flanged ends. Filteration area 1:4

-

-

-

... More
200 mm dia.

2

-

26242

... More
M.S POT-Strainer Complete with Stainless Steel Bucket having 03 mm Perforation, flanged ends. Filteration area 1:4.

-

-

-

... More
200 mm dia.

1

-

22949

... More
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required

8

-

1094

... More
Providing & fixing in position the mercury in glass industrial type thermometers.

4

-

957

... More
Dirt Separator for open loop CNDW pipe

-

-

-

... More
Supply installation testing and commisioning of Deaerator-dirt separator. Flanged connections, complete with Brass drain valve 1” F (from DN 50 to DN 150), 2” F (from DN 200 to DN 300). complete with a set of concentric metal mesh surfaces to create the swirling motion required to facilitate the dirt to the surfaces. Epoxy resin coated steel body. Stainless steel internal element. PP float. Brass float guide and stem. Stainless steel float lever and spring. EPDM hydraulic seals.Maximum working pressure 10 bar. Working temperature range 0–110°C. Particle separation rating down to 5 µ.Working temperature range 0–100°C. Floor brackets as per site requirement.

-

-

-

... More
200 mm dia.

1

-

890870

... More
SUB HEAD 'C'- AIR DISTRIBUTION

-

-

-

... More
DUCTING, GRILLS, DIFFUSER AND INSULATION

-

-

-

... More
Supply, installation, balancing and commissioning of factory/site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.

-

-

-

... More
Thickness 0.63 mm sheet

805

-

983

... More
Thickness 0.80 mm sheet

25

-

1154

... More
Thickness 1.25 mm sheet

10

-

1677

... More
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.

-

-

-

... More
Thickness 0.63 mm sheet

105

-

942

... More
Thickness 0.80 mm sheet

10

-

1104

... More
Thickness 1.00 mm sheet

1

-

1458

... More
Thickness 1.25 mm sheet

10

-

1615

... More
Duct Insulation

-

-

-

... More
Supplying , installation, testing & commissioning of external thermal insulation on ducts with Duly laminated aluminum foil of mat finish Closed Cell Cross Linked Polyethylene (class “O”) insulation shall be 27 ± 3 Kg/m3. The product shall have temperature range of –40 oC to 105oC. Thermal Conductive not exceeding 0.033 W/mK at an average Temperature of 23°C. The insulation material shall be fire rated for Class 1 as per BS 476 Part 6 : 1989 for fire propagation test and for Class 0 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability shall be not less than 0.024 per inch (2.48 x 10-14 Kg/m.s.Pa i.e. µ7000: Water vapour diffusion resistance).The Material shall have Fire Approval from CBRI - Roorkee

-

-

-

... More
19 mm thick Closed Cell Cross Linked Polyethylene( XLPE) Foam with Factory Laminated Aluminium Foil for Supply Air Duct

750

-

663

... More
9 mm thick Closed Cell Cross Linked Polyethylene( XLPE) Foam with Factory Laminated Aluminium Foil for Supply Air Duct (Internal)

90

-

242

... More
Acoustic Lining

-

-

-

... More
Supply, Installation, Testing and Commissioning of Acoustic lining inside ducts using Non Fibrous fire retardant crosslinked polyethylene foam of 60+/- 3 Kg/m3 density & thickness of 15mm having porous surface on one side & a flat surface on other side using Synthetic rubber based Adhesive preferably Low VOC & high strength characteristic(Initial portion of ducting and main plenum) as per specifications

-

-

-

... More
15mm thick ecosound (FR-Open Cell Cross Linked Polyethylene) for supply & return air ducts

100

-

1069

... More
Continuous Grill

-

-

-

... More
Supplying & fixing of powder coated extruded aluminium continuous Grill with louvers but without volume control dampers complete as required.

-

-

-

... More
150 MM Height

52

-

1604

... More
200 MM Height

117

-

1924

... More
Box Type AL. Damper For Continuous Grills

-

-

-

... More
Supplying, fixing, testing and commissioning of aluminium volume control dampers as per specifications.

2

-

4105

... More
Supply Air Grills

-

-

-

... More
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

6

-

8480

... More
Return Air Grills

-

-

-

... More
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

2

-

5507

... More
Supply Air Diffuser

-

-

-

... More
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

5

-

11363

... More
Return Air Diffuser

-

-

-

... More
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

2

-

7559

... More
Fresh Air Grills

-

-

-

... More
Supply, installation, testing and balancing of Powder coated/Anodised extruded aluminium construction fresh air grills with bird screen and volume damper for fresh air as per specifications and approved shop drawings.

2

-

12187

... More
Fire Dampers

-

-

-

... More
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.

-

-

-

... More
a) Fire damper

3

-

9883

... More
b) Actuator

9

-

9212

... More
Volume Control Dampers

-

-

-

... More
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.

7

-

6500

... More
Flexible Duct

-

-

-

... More
Supply, Installation, Testing and Commissioning of pre-insulated factory fabricated semi-rigid flexible ducts of aluminium construction duly supported at regular interval as per site requirement . Ducts shall be of following sizes:

-

-

-

... More
100 mm dia.

85

-

338

... More
Spigots for Flexible Duct

-

-

-

... More
Supply,Installation, Testing and Balancing of spigots factory fabricated out of galvanised steel sheet of different sizes to facilitate flexible duct connection.

-

-

-

... More
100 mm dia.

69

-

205

... More
SUB HEAD 'D'- ELECTRIC WORKS

-

-

-

... More
Electrical Panel

-

-

-

... More
Design, manufacture, supply, installation and commissioning of the following extensible cubicle type indoor mounting Powder coated, modular compartmentalized IP 42, dead front, dust and vermin proof, floor mounting 2 mm thick sheet steel clad switchboard suitable for use at 415 volts 3 phase 4 wire 50 cycle system and to withstand a symmetrical fault level of 35kA at 415 volts.

-

-

-

... More
NOTE: The following provisions shall be required to be made in the switchboard detailed below

-

-

-

... More
The Switchboard shall have provision for entry of all XLPE cables from the top/bottom as required.

-

-

-

... More
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used.

-

-

-

... More
Suitable tinned copper extension links for incoming/outgoing cables shall be provided wherever required

-

-

-

... More
Control circuits includes breaker control switch, auto manual selector switch, anti pumping relay, spring charging trip indication, TIMER, control wiring, Auxiliary contactors MCB’s as required at site

-

-

-

... More
All fault level breaking capacity indicates shall be I.C.S value at 415 volts. (ICS = ICU =ICW=100%) for 1 sec

-

-

-

... More
All MCCB above 100 Amp shall have variable overload settings.

-

-

-

... More
All MCCB shall have with Rotary Handles.

-

-

-

... More
Space heater/light/air filter shall be provided for each vertical compartment.

-

-

-

... More
Padlocking facility shall be provided on all outgoing feeders.

-

-

-

... More
All ACB’s shall have all standard accessories such as CT,s Arc Chute, safety shutters etc.

-

-

-

... More
Link and drops from ACB/MCCB shall be designed for full rated current of ACB/MCCB rating at same amount of current density as of main busbar.

-

-

-

... More
2 No GI strip throughout the panel.

-

-

-

... More
Main AC Panel (HVAC PLANT ROOM)

-

-

-

... More
INCOMINGS

-

-

-

... More
1 Nos. 630 amps, 35 KA electrically operated TPN MCCB microprocesser based release for short circuit, O/C and E/F protection with adjustable setting as per specification suitable to received armoured cable.

-

-

-

... More
0-500 volts Digital voltmeter with selector switch and protection fuses. - 1 Set

-

-

-

... More
0-630 amps, ammeter. with CT's ratio and selector switch- 1 Set

-

-

-

... More
iii. Phase indicating lamps with MCB's Protection. 1 Sets

-

-

-

... More
Communicable type Multi Function Meter (MFM) of accuracy class - 1 with 3 nos. 630/5 amps 10 VA CT's to measure real time, total active energy, maximum demand, instant Power factor, frequency, harmonics etc. - 1 set

-

-

-

... More
Red/Green/Amber/ ON/OFF trip indicating lamps

-

-

-

... More
BUSBAR

-

-

-

... More
Electrolytic high conductivity aluminium three phase and neutral busbars rated at 800 amps having a maximum current density of 1 amp per sq mm suitable to with stand symmetrical fault level of 35 kA at 415 volts. The neutral busbar is to be of 50% capacity.

-

-

-

... More
The fault level and temperature rise calculation to withstand 35kA to be submitted with no derating at 50 deg. Centigrade. The temprise should not be more than 40 °C over ambient of 50 °C.

-

-

-

... More
OUTGOING UNITS

-

-

-

... More
2 Nos 400 amp 35 kA TP+NL MCCB with microprocessor release having overcurrent and short circuit protection for Chiller (150 KW).

-

-

-

... More
1 No. 300 amp 35 kA TP+NL MCCB with microprocessor release having overcurrent and short circuit protection for Hot water generator (120 KW alternate with chiller)

-

-

-

... More
2 Nos. 63 amps TP+N MPCB with Star Delta starter for 22.0 KW motor , over load relay with built in single phasing protection and outgoing feeder to Conderser Water Pump. The compartment shall contain an indicating lamp with MCB for ON & OFF status of pump motor.

-

-

-

... More
2 Nos. 25 amps TP+N MPCB with Star Delta starter for 7.5 KW motor , over load relay with built in single phasing protection and outgoing feeder to Primary Chilled Water Pump. The compartment shall contain an indicating lamp with MCB for ON & OFF status of pump motor.

-

-

-

... More
2 Nos. 63 amps TPN MCCB with thermal magnetic release having overcurrent and short circuit protection with space provision of VFD for Secondary Chilled Water Pump (18.0 KW).

-

-

-

... More
4 Nos. 9-13 amps TP+N MPCB with DOL starter for 5.5 KW motor , over load relay with built in single phasing protection and outgoing feeder to Cooling Tower Fan Motor. The compartment shall contain an indicating lamp with MCB for ON & OFF status of fan motor.

-

-

-

... More
2 Nos. 6.3-10 amps TP+N MPCB with DOL starter for 3.75 KW motor , over load relay with built in single phasing protection and outgoing feeder to HVAC Plant Room FA/EA Fan Motor. The compartment shall contain an indicating lamp with MCB for ON & OFF status of fan motor.

-

-

-

... More
Potential Free Contact for BMS as required.

1

-

585473

... More
Starter Panels

-

-

-

... More
AHU PANEL (7.5 KW AHU Fan Motor) -Floor Mounted AHU

-

-

-

... More
Incoming

-

-

-

... More
1 No. 40 amps. TPN MCB 25 KA

-

-

-

... More
1 No. voltmeter with selector switch

-

-

-

... More
1 Set of RYB indication lamps with MCB & on-off indication lamp.

-

-

-

... More
1 Set start/stop Push Button with A/M selector switch.

-

-

-

... More
Outgoings

-

-

-

... More
1 Nos. 40 amps TPN MCB for AHU motor VFD with space provision for VFD of 7.5 KW

-

-

-

... More
1 No. 6 amps 2 Pole MCB for fire damper actuator.

-

-

-

... More
1 No. 6 amps 2 Pole MCB for UVGI Lamp.

-

-

-

... More
1 No. 6 amps 2 Pole MCB for room thermostat/PICV valve.

-

-

-

... More
1 No. 6 amps 2 Pole MCB for return air temperature sensor/differential pressure transmitter.

-

-

-

... More
NO/NC Contact for BMS as required.

-

-

-

... More
All VFD (as per list of make) shall be with in built harmonic filter & capable to provided digital display showing electrical parameters like voltage, current and power consumption (both KW & KWH) as well as % speed indication. It shall also have Exhaust fan Aux. contactor, Communication Port compatible with BMS etc. complete as required The Drive is having IP 55 Enclosure for safe and reliable operation. The Drive should have 3C3 Coating on PCBs to safeguard the Drives from any contaminants in the ambient. VFD HAVE THE FOLLOWING CONTROLS:- 1-TEMP. SENSOR FEEDBACK TO CONTROL THE FAN SPEED FROM VFD. 2-TRIGGERING THE AHU SHUTDOWN DURING THE FIRE ON GETTING SIGNAL FROM FIRE DAMPERS

1

-

35920

... More
AHU PANEL (2.2 KW AHU Fan Motor) -Ceiling Mounted AHU/TFA

-

-

-

... More
Incoming

-

-

-

... More
1 No. 25 amps. TPN MCB 25 KA

-

-

-

... More
1 No. voltmeter with selector switch

-

-

-

... More
1 Set of RYB indication lamps with MCB & on-off indication lamp.

-

-

-

... More
1 Set start/stop Push Button with A/M selector switch.

-

-

-

... More
Outgoings

-

-

-

... More
1 Nos. 25 amps TPN MCB for AHU motor VFD with space provision for VFD of 2.2 KW

-

-

-

... More
1 No. 6 amps 2 Pole MCB for fire damper actuator.

-

-

-

... More
1 No. 6 amps 2 Pole MCB for UVGI Lamp.

-

-

-

... More
1 No. 6 amps 2 Pole MCB for room thermostat/PICV valve.

-

-

-

... More
1 No. 6 amps 2 Pole MCB for return air temperature sensor/differential pressure transmitter.

-

-

-

... More
NO/NC Contact for BMS as required.

-

-

-

... More
All VFD (as per list of make) shall be with in built harmonic filter & capable to provided digital display showing electrical parameters like voltage, current and power consumption (both KW & KWH) as well as % speed indication. It shall also have Exhaust fan Aux. contactor, Communication Port compatible with BMS etc. complete as required The Drive is having IP 55 Enclosure for safe and reliable operation. The Drive should have 3C3 Coating on PCBs to safeguard the Drives from any contaminants in the ambient. VFD HAVE THE FOLLOWING CONTROLS:- 1-TEMP. SENSOR FEEDBACK TO CONTROL THE FAN SPEED FROM VFD. 2-TRIGGERING THE AHU SHUTDOWN DURING THE FIRE ON GETTING SIGNAL FROM FIRE DAMPERS

4

-

25939

... More
AHU PANEL (1.5/1.1 KW AHU Fan Motor) -Ceiling Mounted AHU/TFA

-

-

-

... More
Incoming

-

-

-

... More
1 No. 20 amps. TPN MCB 25 KA

-

-

-

... More
1 No. voltmeter with selector switch

-

-

-

... More
1 Set of RYB indication lamps with MCB & on-off indication lamp.

-

-

-

... More
1 Set start/stop Push Button with A/M selector switch.

-

-

-

... More
Outgoings

-

-

-

... More
1 Nos. 20 amps TPN MCB for AHU motor VFD with space provision for VFD of 1.5/1.1 KW

-

-

-

... More
1 No. 6 amps 2 Pole MCB for fire damper actuator.

-

-

-

... More
1 No. 6 amps 2 Pole MCB for UVGI Lamp.

-

-

-

... More
1 No. 6 amps 2 Pole MCB for room thermostat/PICV valve.

-

-

-

... More
1 No. 6 amps 2 Pole MCB for return air temperature sensor/differential pressure transmitter.

-

-

-

... More
NO/NC Contact for BMS as required.

-

-

-

... More
All VFD (as per list of make) shall be with in built harmonic filter & capable to provided digital display showing electrical parameters like voltage, current and power consumption (both KW & KWH) as well as % speed indication. It shall also have Exhaust fan Aux. contactor, Communication Port compatible with BMS etc. complete as required The Drive is having IP 55 Enclosure for safe and reliable operation. The Drive should have 3C3 Coating on PCBs to safeguard the Drives from any contaminants in the ambient. VFD HAVE THE FOLLOWING CONTROLS:- 1-TEMP. SENSOR FEEDBACK TO CONTROL THE FAN SPEED FROM VFD. 2-TRIGGERING THE AHU SHUTDOWN DURING THE FIRE ON GETTING SIGNAL FROM FIRE DAMPERS

12

-

25939

... More
AHU PANEL (0.55 KW AHU Fan Motor) -Ceiling Mounted TFA

-

-

-

... More
Incoming

-

-

-

... More
1 No. 16 amps. TPN MCB 25 KA

-

-

-

... More
1 No. voltmeter with selector switch

-

-

-

... More
1 Set of RYB indication lamps with MCB & on-off indication lamp.

-

-

-

... More
1 Set start/stop Push Button with A/M selector switch.

-

-

-

... More
Outgoings

-

-

-

... More
1 Nos. 16 amps TPN MCB for AHU motor VFD with space provision for VFD of 0.55 KW

-

-

-

... More
1 No. 6 amps 2 Pole MCB for fire damper actuator.

-

-

-

... More
1 No. 6 amps 2 Pole MCB for UVGI Lamp.

-

-

-

... More
1 No. 6 amps 2 Pole MCB for room thermostat/PICV valve.

-

-

-

... More
1 No. 6 amps 2 Pole MCB for return air temperature sensor/differential pressure transmitter.

-

-

-

... More
NO/NC Contact for BMS as required.

-

-

-

... More
All VFD (as per list of make) shall be with in built harmonic filter & capable to provided digital display showing electrical parameters like voltage, current and power consumption (both KW & KWH) as well as % speed indication. It shall also have Exhaust fan Aux. contactor, Communication Port compatible with BMS etc. complete as required The Drive is having IP 55 Enclosure for safe and reliable operation. The Drive should have 3C3 Coating on PCBs to safeguard the Drives from any contaminants in the ambient. VFD HAVE THE FOLLOWING CONTROLS:- 1-TEMP. SENSOR FEEDBACK TO CONTROL THE FAN SPEED FROM VFD. 2-TRIGGERING THE AHU SHUTDOWN DURING THE FIRE ON GETTING SIGNAL FROM FIRE DAMPERS

1

-

17387

... More
Starter Panel for Normal & Emergency Supply/ Exhaust Fans

-

-

-

... More
Emergency Exhaust Fan Panel- 11.0 KW

-

-

-

... More
1 No. 32 amps. TP+N MPCB

-

-

-

... More
1 No. Star Delta starter for 11.0 KW

-

-

-

... More
3 Nos. RYB Indication Lights LED type with MCB

-

-

-

... More
2 Nos. Push Buttons

-

-

-

... More
1 No. direct digital ammeter

-

-

-

... More
NO/NC Contact for BMS as required.

3

-

25986

... More
Emergency Supply Fan Panel- 5.5 KW

-

-

-

... More
1 No. 9-13 amps. TP+N MPCB

-

-

-

... More
1 No. DOL starter for 5.5 KW

-

-

-

... More
3 Nos. RYB Indication Lights LED type with MCB

-

-

-

... More
2 Nos. Push Buttons

-

-

-

... More
1 No. direct digital ammeter

-

-

-

... More
NO/NC Contact for BMS as required.

6

-

19813

... More
Isolator for Cooling Towers

-

-

-

... More
Supplying, installation testing and commissioning of 415 volt three phase and neutral swith outlets TPN MCCB/MCB iasolator in weather proof IP 65 enclosure. The quantities of isolators is as follows.

-

-

-

... More
32 amps TPN MCB in weather proof enclosure for 5.5 KW cooling tower fan motor.

4

-

1092

... More
Supplying and fixing following modular switch/ socket on modular plate & switch box including connections etc. as required.5 pin 6 amp socket outlet for HCU/FCU

94

-

401

... More
Power Cables

-

-

-

... More
Supply and laying of the following 1100 volt grade armoured XLPE insulated and PVC sheathed aluminium conductor cable in trench / cable tray /clamped to wall with suitable clamps saddles & fixing bolts/including testing & commissioning complete as required. The costs shall include crimping tinned heavy duty alluminium lugs, compression glands requisite materials for all cables and to provide with 1D gap & shall be properly clamped with cable clamps & ties. Identification tags shall be provided for all cables including cable end termination.

-

-

-

... More
3.5 core 185 Sq mm

60

-

1455

... More
3.5 core 120 Sq mm

30

-

979

... More
3.5 core 25 Sq mm

120

-

292

... More
3 core 16 Sq mm

15

-

204

... More
3 core 10 Sq mm

40

-

199

... More
3 core 6 Sq mm

75

-

165

... More
3 core 4 Sq mm

60

-

141

... More
3 Core x 2.5 Sq.mm

400

-

125

... More
Electrical Cable Tray

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray cable tray with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
150 mm width X 50 mm depth X 1.6 mm thickness

750

-

644

... More
300 mm width X 50 mm depth X 1.6 mm thickness

85

-

875

... More
450 mm width X 50 mm depth X 2.0 mm thickness

25

-

1213

... More
Earthing

-

-

-

... More
Providing and fixing earth bus of 50 mm X 5 mm G.I. strip on surface for connections etc. as required.

200

-

206

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

1790

-

57

... More
Control Cable

-

-

-

... More
Supply ,installation ,testing , termination & commissioning of copper armoured pvc insulated ,pvc sheathed copper control cable of following size to various equipment including interconnection from electric supply to equipment on existing cable tray /support as required and as below

-

-

-

... More
3 Core x 1.5 Sq.mm

650

-

150

... More
MS Conduit

-

-

-

... More
Supplying and fixing of following sizes of steel conduit (medium) along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.

-

-

-

1400

-

165

... More
SUB HEAD 'E'- CIVIL WORKS

-

-

-

... More
GYPSUM BOARD FALSE CEILING

-

-

-

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :

-

-

-

... More
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)

250

-

1145.95

... More
Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :

-

-

-

... More
GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.

250

-

1871.8

... More
GYPSUM BOARD PARTITIONS

-

-

-

... More
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.

-

-

-

... More
75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks)

200

-

1797.65

... More
STEELWORK

-

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

908.08

-

111.95

... More
Glazing Partition

-

-

-

... More
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.

150

-

8230.05

... More
EXCAVATION

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.

-

-

-

... More
ALL KIND OF SOIL

300

-

205.45

... More
Extra for additional lift of 1.5m or part thereof in excavation/banking excavated or stacked materials

-

-

-

... More
ALL KIND OF SOIL

600

-

104.5

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

100

-

2161.2

... More
PCC WORK

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level ::

-

-

-

... More
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

4

-

6326.05

... More
SHUTTERING WORK

-

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for

-

-

-

... More
Foundations, footings, bases for columns

40

-

307.95

... More
Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.

375

-

669.55

... More
Columns, piers, abutments, pillars, posts and struts

150

-

804.25

... More
Suspended floors, roofs, landings, balconies and access platform

250

-

766.55

... More
RCC WORK

-

-

-

... More
Providing and laying in position machine batched and machine mixeddesign mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).

-

-

-

... More
All works upto plinth level

-

-

-

... More
Concrete of M25 grade with minimum cement content of 330 kg /cum

145

-

7997.3

... More
Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof

20

-

280.95

... More
REINFORCED STEEL WORK

-

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.

-

-

-

... More
Thermo-Mechanically Treated bars of grade Fe-500 D or more.

16000

-

89.65

... More
EXPOSED BRICK WALL

-

-

-

... More
Brick work with common burnt clay modular bricks of class designation 7.5 in exposed brick work including making horizontal and vertical grooves 10mm wide 12 mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand).

-

-

-

... More
Above plinth level upto floor V level

95

-

7218.75

... More
FLUSH DOOR SHUTTER

-

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:

-

-

-

... More
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.

45

-

2015.75

... More
PLASTER WORK

-

-

-

... More
INTERNAL PLASTER

-

-

-

... More
12 mm cement plaster of mix

-

-

-

... More
1:4 (1 cement: 4 fine sand)

670

-

294.85

... More
EXTERNAL PLASTER

-

-

-

... More
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).

170

-

442.75

... More
PAINT WORK

-

-

-

... More
INTERNAL PAINT

-

-

-

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade

-

-

-

... More
Two or more coats on new work

670

-

137.85

... More
EXTERNAL PAINT

-

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade :

-

-

-

... More
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

170

-

166.85

... More
WATER PROOFING

-

-

-

... More
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:

-

-

-

... More
after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.

-

-

-

... More
laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.

-

-

-

... More
third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.

-

-

-

... More
fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured.

250

-

585.55

... More
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of :

-

-

-

... More
Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound.

-

-

-

... More
2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions.

-

-

-

... More
Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer.

-

-

-

... More
Using rough kota stone.

20

-

1362.95

... More
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge :

-

-

-

... More
Using rough kota stone.

20

-

1780.3

... More
STRUCTURAL GLAZING

-

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :

-

-

-

... More
For fixed portion

-

-

-

... More
Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)

550

-

433.95

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):

-

-

-

... More
With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)

21

-

1019.8

... More
SUB HEAD 'F'- BUILDING MANAGEMENT SYSYTEM (SAC)

-

-

-

... More
Supplying, Installing, Testing & Commissioning of following

-

-

-

... More
BMS Machine: Intel i7 (Latest Technology), Windows® 2010 SP2 or above operating System, 1 TB HDD, 8 GB RAM, Enhanced graphic Card, DVD Combo Drive, Ethernet Port with 32" color monitor flat screen LED display, multimedia keyboard & optical mouse and microsoft office 2013 and anti virus as per Specification.

1

-

162250

... More
A4 B/W laser Printer

1

-

26550

... More
Software: Web Based Graphical interface software. The system should be accessible from anywhere on LAN or WAN or Ethernet without additional licenses. The Communication protocol shall be one of the Industry Standard Open Protocols such as BACNet, LON etc. System should be scalable and software should be integrable with Access Control, CCTV VMS seamlessly to generate a holistic view. Software shall have 3 simultaneous user license.

1

-

248697

... More
Third Party Integartion: UL & BTL listed Gateway / Open Protocol Software for integrating the foll third party system communicating on one of the Standard Open Protocols such as BACNet , MODBUS, Lonworks, M-Bus, J Bus etc - Vendor to consider required No. of Integrators for qty's mentioned in IO summary. Integrator/Gateway/supervisory controller shall be of the same OEM as field controllers & software. Integration of following services should be considered:

1

-

407454

... More
Chillers : 2 Nos.

-

-

-

... More
CCTV System : 1 Nos.

-

-

-

... More
Fire Alarm & Detection System : 1 Nos.

-

-

-

... More
FCU/HCU Thermostat : 96 Nos.

-

-

-

... More
IP DDC Field Controller: SITC of Standalone BTL & UL listed BACNet I/P field DDC controller having universal input/ output ports. Controller shall have 2 10/100 ethernet port & can communicate in Star/Daisy chain topology & offer network redundancy for communication. DDC controller shall be DHCP enabled to ensure VPN network .

-

-

-

... More
All DDC Controllers shall be provided with hinged doors with locking facility. Apart from the controllers, the enclosers shall house the terminal blocks, load relays and associaetd equipment. The internal wiring in the enclosure shall be factory wired. The packaging shall be such that complete installation of the field equipment and field wiring can be done prior to the installation of the electronics.

-

-

-

... More
The controller shall be independent in operation and the failure of any other device / controller or the operator workstations, shall not cause any disruption to the function of the rest of the system. The DDC controllers shall have the facility to implement user modifiable time schedules as daily, weekly, monthly annual temporary schedules.

-

-

-

... More
The DDC controllers would 'reboot' automatically on resumption of power. Controllers shall not require manual intervention for the reboot of the controller software.

-

-

-

... More
DDC controllers shall have provision for 10% IO points

-

-

-

... More
DDC for Chiller Plant (Chillers, PP, VSP, CP,CT, HWG etc.)

1

-

277300

... More
DDC for Treated Fresh Air Handling Unit (Ceiling Suspended)

5

-

77172

... More
DDC for Air Handling Unit (Ceiling Suspended)

22

-

67968

... More
Field Devices

-

-

-

... More
Immersion type temperature sensor for Chilled Water temperature

13

-

2714

... More
Outside Air Temperature & Humidity Sensor as per technical specification

1

-

20851

... More
Differential pressure switches for pump status as per technical specification

7

-

11210

... More
Water pressure Transmitter as per technical specification

2

-

10030

... More
Duct mount Temperature sensor as per technical specification

27

-

3481

... More
Duct mount Temperature & RH sensor as per technical specification

5

-

15930

... More
Outside CO2 sensors as per technical specification

1

-

15930

... More
Differential pressure switches for indicating the Blower & Filter status in Air as per technical specification.

54

-

3257

... More
Bi-level switch for Hi-Lo level monitoring as per technical specification

2

-

7670

... More
Wall mount Temperature & RH sensor as per technical specification

2

-

14750

... More
PH sensor as per technical specification

2

-

64900

... More
TDS sensor as per technical specification

2

-

92040

... More
Current relay as per technical specification

2

-

2950

... More
Flow switch as per technical specification

4

-

3422

... More
Networking Devices & Accessories

-

-

-

... More
Supply, installation, testing and commissioning of Layer 2 unmanaged 10/100 switch. The switch shall have work with CAT6 armourded UTP cable within the building complete as per specifications and as required for BMS DDC Panel Networking.

-

-

-

... More
16 Port Switch

3

-

28320

... More
Control Cable

-

-

-

... More
2 x 1.5 sq.mm Annealed Tinned Copper Shielded armoured cable for signal and power as per specification. (for I/O points hard wired to DDC).

5500

-

126

... More
4 x 1.5 sq.mm Annealed Tinned Copper Shielded armoured cable for signal and power as per specification. (for I/O points hard wired to DDC).

450

-

177

... More
CAT 6 A unarmoured cables with required accessories like RJ45 connector etc.

650

-

269

... More
3 x 1.5 sq.mm Annealed Tinned Copper Shielded armoured cable for signal and power as per specification. (power Cable).

250

-

150

... More
Electrical Cable Tray

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
100 mm width X 50 mm depth X 1.6 mm thickness

425

-

599

... More
150 mm width X 50 mm depth X 1.6 mm thickness

275

-

644

... More
300 mm width X 50 mm depth X 1.6 mm thickness

150

-

875



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.