Indian Institute Of Petroleum Tender

View complete overview of Uttarakhand IIP Tender

Indian Institute Of Petroleum - IIP Tender

Works
Electrical Cables And Wires
Electrical and Electronics
Eprocure
Opening Date12 Oct 2022
Closing Date26 Oct 2022
Tender Amount₹ 14,52,046 
Notes
Download

Costs

Summary

Supplying And Laying Of Electrical Cable From Training Center To Guest House

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.

-

-

-

... More
above 35sqmm and upto 95sqmm(clamped with 25x40x3mm ms flat clamp)

140

-

-

... More
above 95sqmm and upto 185sqmm(clamped with 25x40x3mm ms flat clamp)

70

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required

-

-

-

... More
3.5 X 150 sq. mm

6

-

-

... More
3.5 X 70 sq. mm

12

-

-

... More
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required

-

-

-

... More
150 mm dia

12

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.

2

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required

10

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

10

-

-

... More
Structural steel work in single section, fixed with or without conntecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

150

-

-

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

20

-

-

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel/ MCCM enclosure including drilling holes in cubicle panel, making connections etc as required

-

-

-

... More
200A, 36KA, FP MCCB

1

-

-

... More
400A, 35KA, TP MCCB

1

-

-

... More
Automaticload transfer switch (ATS) with controller with Automatic/ manual mode with complete ATS controller and enclosure three phase four pole 50 hz, 415v 315A with handle assembly frame size 3 rated insulation voltage Ui (Vac) 1000, dielectric strength (Vac) 50hz 1 minute 8000, no of pole 4, voltage of motor 2A/230VAC, with 1.2mm ms cubical housing for protecting dust, vermin and other ambient effect. Three phase indicator sp mcb with control wiring etc as reqired

1

-

-

... More
Automaticload transfer switch (ATS) with controller with Automatic/ manual mode with ATS controller and enclosure three phase four pole 50 hz, 415v 200A with handle assembly frame size 3 rated insulation voltage Ui (Vac) 1000, dielectric strength (Vac) 50hz 1 minute 8000, no of pole 4, voltage of motor 2A/230VAC, with 1.2mm ms cubical housing for protecting dust, vermin and other ambient effect. Three phase indicator sp mcb with control wiring etc as reqired

1

-

-

... More
supplying of XLPE PVC aluminium conductor 1100v grade confirming to IS 7098 A2XWY 3.5X150sqmm armound cable.

250

-

-

... More
supplying of XLPE PVC aluminium conductor 1100v grade confirming to IS 7098 A2XWY 3.5X70sqmm armound cable.

500

-

-

... More
SITC of 1.2 mm ms cubical outdoor type panel (1200mmX1000mmx450mm deep) double housing with double door dust and vermin proof, open mounted and fastened with insulator. Whole cubical panel mounted and grouted by 40mmX6mm angle iron. The whole cubical panel must paint and premier.

2

-

-

... More
Supplying and fixing 400A bus bar aluminium three phase four pole bus bar box duly painted dust and vermin proof etc as required.

1

-

-

... More
Supplying and fixing 100A bus bar aluminium three phase four pole bus bar box duly painted dust and vermin proof etc as required.

2

-

-

... More
Providing and fixing 3mm thick chequered plate with complete as per engineer in charge etc as reqd

200

-

-

... More
Supplying of modular surge protection unit having replacbleable plugin base and modules should be tested as per IEC 61643-11 standard and specified according to both T1 & T2 test classes. SPD should have status indicator and fault signaling contact for remote monitoring of status information. SPD should be TP+N type and N pole should be protected by encapsulated spark gap. SPD should be suitable for the impulse current limp at least 50KA (10/350 micro wave) per pole up-1.5KV Uc Vac

2

-

-

... More
Supplying and fixing of MCCB enclosure for suitable of 400A 35KA four pole MCCB enclosure dust and vermin proof mounting on wall with PVC fasthener etc as required.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.