Indian Institute Of Petroleum Tender
View complete overview of Uttarakhand IIP Tender
Indian Institute Of Petroleum - IIP Tender
Electrical and Electronics
Eprocure
Opening Date14 Jun 2024
Closing Date21 Jun 2024
Tender Amount₹ 77,104
Costs
EMD
₹ 1,550Document Cost
₹ 590Tender Fee
Refer Documents
Summary
Renovation Of Canten Backyard Area.(electrical Works)
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CSIR_198250_1Bid Award Id
ViewTender No
IIP/ESD/2/8/2024Tender Authority
Indian Institute Of Petroleum ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
2x1.5 sq mm + 1x1.5 sq mm earth wire
20
-
-
2x2.5 sq mm + 1x2.5 sq mm earth wire
30
-
-
2x4 sq mm +1x4 sq mm earth wire
30
-
-
2x6 sq mm + 1x6 sq mm earth wire
20
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recessed including cutting the wall and making good the same in case of recessed conduit as required.(AKG/M-key)
-
-
-
20 mm
20
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.
-
-
-
15/ 16 amps switch
2
-
-
3 pin 5/6 amps socket oulet
10
-
-
6 pin 15/ 16 amps socket oulet
2
-
-
Bell Push
1
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
2
-
-
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switch in recess etc as required
-
-
-
6 module (200 mm x 75 mm)
2
-
-
8 module (125 mm x 125 mm)
2
-
-
12 module (200 mm x 150 mm)
2
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. As required
2
-
-
Supplying and fixing 3 pin, 5A ceiling rose on the existing junction box/ wooden block including connection etc as required
2
-
-
installation, testing and commissioning of ceiling fan, including wiring the down rod of standrand lenght ( up to 30cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. As required
2
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc. as required (but without mcb, rccb/isolator)
-
-
-
12 way, double door
1
-
-
Supplying and fixing 5 amps to 32 amps rating, 240v/ 415v, "C" curve, miniture circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissioning etc. As required
-
-
-
single pole
12
-
-
Double pole
2
-
-
supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connetionx, testing and commissioning etc. as required.
-
-
-
63 amps
1
-
-
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
2
-
-
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing et. complete s required.
2
-
-
supply and commissioning of indoor recess/ surface 600X600mm (2'X2') LED luminaire 42w with high luman package etc as required.The product features special glare cut optics to ensure low luminaire luminance and is perfect for general and office lighting applications such as workstations, meeting rooms and cabins,corridors and break areas.(Havells/ Wipro/ Philiphs/ c&s) The same will be inspected and aproved by Engineer-in-charge before its dispatch from factory to site.
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements