Haridwar Roorkee Development Authority Tender

View complete overview of Uttarakhand HRDA Tender

Haridwar Roorkee Development Authority - HRDA Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date19 Dec 2023
Closing Date4 Jan 2024
Tender Amount₹ 1,13,94,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications PCC Grade M20

23.07

-

-

... More
Plastering with cement mortar (1:3 ) on brick work in sub-structure as per Technical specifications

120.07

-

-

... More
Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)

120.07

-

-

... More
Painting on Steel Surfaces (Providing and applying two coats of ready mix paint of approved brand on steel surface after through cleaning of surface to give an even shade)

718.13

-

-

... More
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.

657.29

-

-

... More
Provinding and fixing of SS-304 setting Bench three Seater

5

-

-

... More
SEWERAGE AND STROM WATER WORKS

-

-

-

... More
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia

588.54

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1 :2 :4 ( 1 Cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 40 mm nominal size)

147.15

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1:4:8 (1 cement :4 course sand (zone-II): 8 graded stone aggregate 40 mm nominal size)

44.14

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

20

-

-

... More
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

15

-

-

... More
Extra for depth for manholes :Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

20

-

-

... More
Extra for depth for manholes :Size 120x90 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

15

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

245

-

-

... More
Providing and Laying the DOUBLE WALL-CORRUGATED (DWC) HDPE Pipes conforms the IS 16098 (Part-2) : 3013 Structure-Wall Plastics pipeing system for NON- Pressure Dranage and sewerage - Specification inlcuding the cost of jointing materials as well as carriage, loading, unloading, stacking handling, re-handling etc. complete in all respect to the satisfaction to the Engineer-in-Charge. 150 mm dia pipe

150

-

-

... More
Providing and Laying the DOUBLE WALL-CORRUGATED (DWC) HDPE Pipes conforms the IS 16098 (Part-2) : 3013 Structure-Wall Plastics pipeing system for NON- Pressure Dranage and sewerage - Specification inlcuding the cost of jointing materials as well as carriage, loading, unloading, stacking handling, re-handling etc. complete in all respect to the satisfaction to the Engineer-in-Charge. 200 mm dia pipe

188.54

-

-

... More
Providing and Laying the DOUBLE WALL-CORRUGATED (DWC) HDPE Pipes conforms the IS 16098 (Part-2) : 3013 Structure-Wall Plastics pipeing system for NON- Pressure Dranage and sewerage - Specification inlcuding the cost of jointing materials as well as carriage, loading, unloading, stacking handling, re-handling etc. complete in all respect to the satisfaction to the Engineer-in-Charge. 250 mm dia pipe

100

-

-

... More
Providing and Laying the DOUBLE WALL-CORRUGATED (DWC) HDPE Pipes conforms the IS 16098 (Part-2) : 3013 Structure-Wall Plastics pipeing system for NON- Pressure Dranage and sewerage - Specification inlcuding the cost of jointing materials as well as carriage, loading, unloading, stacking handling, re-handling etc. complete in all respect to the satisfaction to the Engineer-in-Charge. 300 mm dia pipe

100

-

-

... More
SYNTHETIC TRACK works

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1:4:8 (1 cement :4 course sand (zone-II): 8 graded stone aggregate 40 mm nominal size)

84.4

-

-

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.

632.97

-

-

... More
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).

84.4

-

-

... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25

126.59

-

-

... More
Supply and Application of synathetic track sports Flooring with hybrid waterborne PU top coat finish on Asphult sub base which is durable, required minimal maintenance, All-weather suitable/friendly, eco-friendly, Protective Against UV rays consists of the following layers -Acrylic Resurfacer for filling and smoothing subfloor (2 layer)-Triple Layer of Acrylic Rubber cushion (3- Layers) -Anti Skid Base Coat (1- layer) (base color Coat) - Acrylic Top Coat (1 Layer) -Hybrid waterborne HPU-500 Top coat to protect flooring against UV Rays followed by Game Line marking (2- layers) "

562.64

-

-

... More
STREET LIGHT AND EXTERNAL PANEL WORKS

-

-

-

... More
Excavation in Cutting in Soil by manual means with lead upto 50 m Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3

5.06

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1:4:8 (1 cement :4 course sand (zone-II): 8 graded stone aggregate 40 mm nominal size)

16.26

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)

17.39

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form work for :Columns, piers, abutments, pillars, posts and struts

15.58

-

-

... More
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect for all heights/depths/storeys/basements etc.Thermo-Mechanically Treated bars of grade Fe-500D or more.

350

-

-

... More
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)

26.72

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

3055.5

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

105

-

-

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work

469

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. Details of cost for one Set

20

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

200

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

400

-

-

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

50

-

-

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

20

-

-

... More
PProviding and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.

350

-

-

... More
Providing and fixing of insulated rubber matting suitable for 11 KV installation 1 M x 2 M x 12 mm thick (IS code 15652-40091) as per specification complete and as per directions of Engineer-in-charge

12

-

-

... More
Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages.

2

-

-

... More
Supply and erection of shock restoration chart in glass frame.

2

-

-

... More
Supply & Erection of mild steel bucket stand suitable for 6 Nos. fire buckets,(but without bucket) including the cost of welding and painting of complete stand will one coat of red oxide and 2 coats of approved paint of red colour with all labour and material required to complete the job in all respect up to the entire Satisfaction engineer in charge of the work (size 6'x4' made of GI pipe 32mm dia).

2

-

-

... More
Supply and erection of P.U Painted 6 Mtr. Decorative Pole made out of GI Pipe as per our Cat no.( VSTP-41-60 ) with M.S Base Plate Ø340x6mm. inbuilt Control Box at the bottom of the pole for space for Housing MCB & Terminal strip etc. Nos. 30 50895 1526850 Specification of Pole Sections: 1st Section - Ø139.7 x 4.2 x 6000mm without Bracket With Foundation Bolt 20x700x4Nos. Without Light With Polyurthane Painted as per your given color shade With Electrical Accessories like - Bakelite Sheet & Wire including cost of nut and bolts , earthing studs, Integral Cable termination arrangement 5 mm thick Bakelite base plate on suitable welded MS/GI bracket 32 A four way connector 2 no 10 A SP MCB , end cover and all accessories as supplied by the manufacture including Providing RCC foundation of M25 grade (1 Cement:1 Stone aggregate: 2 Coarse sand) i/c excavation, steel reinforcement (Fe 500) @80 kg/cum of concrete contents, concrete cover 50mm, anchor bolts etc. over a bed of PCC 1:5:10 of required dimensions for octagonal poles of various heights as per following specifications complete in all respects and as per directions of Engineer-in-charge 7 Metre Long pole with top dia 75 0mm and bottom dia 150 mm with base plate of size 300 x 300 x 20 mm

10

-

-

... More
Supply and erection of Bollards Led for garden made out extruded aluminium profile with aluminium base and PC/PMMA diffuser for uniform light distribution. VSTP BL 1309, 9 watt led height 800 mm.Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required.

5

-

-

... More
Supply and erection of weather proof M.S. box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S. sheet hinged cover, locking arrangement , housed in wall , including the cost of 1 no. 16 amp. 415 volts SP MCB and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board/10 mm Bakellite sheet in the M.S. box including painting and necessary connections .

4

-

-

... More
Supply and laying of L.T Aluminium conductor 3.5 Core * 120 sqmm armond cable in sand & brick 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect ( NS )CCI/Havells/ICL/Grandly/Universal

150

-

-

... More
Supply and laying of L.T Aluminium conductor 3.5 Core * 120 sqmm armond cable in Loose in existing trench , cable tray etc. 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect ( NS )CCI/Havells/ICL/Grandly/Universal

80

-

-

... More
Supply and fixing of 4.5kg C02 gas type fire extinguishe as per IS: 15683(4.5 kg.) with 3 Year free comprehensive warranty period including cost of petty material required to complete the work upto the entire satisfaction of Engineer In Charge.

3

-

-

... More
SITC of Post Top LED Light 50W as per Cat. No. VSTP PT-30) fixture made of aluminum Die Cast housing with front opening PC Diffuser having IP65 protection, PF.90 , Lumen-110/w with High Efficiency LED, THD-10%, potted driver with 6kva surge Protection

10

-

-

... More
Making 200 mm dia hole by aguring for crossing of road / path etc.

50

-

-

... More
Supply and laying of L.T Aluminium conductor 3.5 Core * 25 sqmm armond cable in Loose in existing trench , cable tray etc. 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect ( NS )CCI/Havells/ICL/Grandly/Universal

50

-

-

... More
Supply and laying of L.T Aluminium conductor 3.5 Core * 25 sqmm armond cable in sand & brick 1 mtr below ground level including suitable Al. Lugs , Glands , connections complete in all respect ( NS )CCI/Havells/ICL/Grandly/Universal

350

-

-

... More
Supply and erection double pole / Four pole Residual current circuit breaker (RCCB/ELCB) suitable for operation on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required tocomplete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. 16A/240V DP ELCB with 100mA sensitivity.

6

-

-

... More
Supply and erection double pole / Four pole Residual current circuit breaker (RCCB/ELCB) suitable for operation on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required tocomplete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. 40A/415V FP ELCB with 100mA sensitivity.

6

-

-

... More
Supply and erection double pole / Four pole Residual current circuit breaker (RCCB/ELCB) suitable for operation on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required tocomplete the job in all respect upto the entire satisfaction of Engineer-in-Charge of the work. 63 A/415V FP ELCB with 100mA sensitivity.

4

-

-

... More
Supply installation testing and commissioning of Wall/free floor mounting dust & vermin proof compartmentalized cubical panel made out of 2mm thick CRCA sheet, required hardware 3mm thick bakelite sheet provided all along the bus bar and cable alley separating switches compartment and supporting suitable channel duly painted by 2 coat of Zine/Red oxide primer followed by 2 coats of powder coating in grey or required shade after rinsing. the panel having PU/Neoprene rubber gasket of not less than 3mm thickness separate detachable gland plate MS base channel hinged door with inter locking arrangement for equipment/switch wear as per detail.

175

-

-

... More
Suppliying and fixing of copper bus bar duly tinned by means of SMC/DMC type insulator high tensile nuts and bolts spring washers fixing to same in existing panel including bending, cutting in required shape and size and insulation with colour coding heat shrinkable PVC insulation Complete in all respect.

95.8

-

-

... More
Pdg. And fixing digital metering equipment for LT cubical panel consisting of 96mm x 96mm 0-500 V, volt meter with selector switch , Amp meter (of required ratio up to 600/5 amp.) with selector switch and required C.Ts 3 Nos…, a set of 3 No. phase indication lamps RYB LED

10

-

-

... More
Supply & fixing of rotary handle for on/off operation of existing MCCB in th LT panel including fixing the same in position with all labour and material required to complete the job in all respect Rotary handle up to 125A, MCCB

2

-

-

... More
Supply & fixing of rotary handle for on/off operation of existing MCCB in th LT panel including fixing the same in position with all labour and material required to complete the job in all respect Rotary handle above 125A, MCCB

3

-

-

... More
SITC of 9 Mtr Long Trudge M in 120 W with Six Angular bracket module each of 120W , homogeneous light distribution suitable for landscape area , led lumen output is more than 125lm/ watt with life cycle of 50000 hrs can be mounted on 9 mtr height pole. Every module is in angular shape and produce diffuse light in 120 degree complete fixture is made up of die cast aluminium and proper heat sink on every module complete fixture is weather protected and suitable for outdoor application . Fixture is with Osram / Samsung Led and PHiliphs/ meanwell / Fulham diver. Fixture dia with bracket is 1124mm. Fitting is with all the accessories required for mounting. VAT-PT-TUR-M-POST-120 Code

4

-

-

... More
Supply and erection of module case circuit breaker single pole/4 pole on wall on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp

2

-

-

... More
Supply and erection of module case circuit breaker single pole/4 pole on wall on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of the work. 4 pole MCCB 200 amp

2

-

-

... More
Supply and erection of module case circuit breaker single pole/4 pole on wall on existing pedestal including bounding to earth and making necessary connection required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of the work. 4 pole MCCB 300 amp to 400 amp

1

-

-

... More
Supply and erection of =12W LED spot projector having following specification housing aluminium body ,mounting surface mount/spike, IP voltage –AC 100-277V, total power consumption – 12W (i/c driver), Lamp Luminous efficiency - 60lm/W, Lumens - 720 lm, CCT - 5700K/RGB/RGBW , beam angle 6 degree to 90 degree , cover PMMA lens, Dimension dia 94x100x177 mm, operating tempracture = -35°C to + 45°C, control Remote/ON -Off IP rating luminiare - IP65, IK rating IK07, power factor = ≥0.95, life span 50000 hours ( Ta=35 degree C@L70) ,THD10% Complete in all respect with the entire satisfaction of Engineer-in-Charge. (Make: Jaquar ,wipro).

15

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.