Supply And Installation Of Ac At Sports Complex At Haridwar
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HRDA_76913_1Bid Award Id
ViewTender No
Supply and installition of AC at sports complex at HaridwarTender Authority
Haridwar Roorkee Development Authority ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply, installation, testing and commissioning of Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities.
Make: To be approved by engineer in charge before installation. 4-way Cassette Type Indoor Units 2.5 HP (2 TR)
12
-
-
Supply, installation, testing and commissioning of Cordless Remotes required for VRV/VRF type indoor units complete as required. Make: To be approved by engineer in charge before installation.
12
-
-
Supply, installation, testing and commissioning of Y-Joint / Refent complete as required. Make: To be approved by engineer in charge before installation. For Indoor Unit
12
-
-
Supply, installation, testing and commissioning of Y-Joint / Refent complete as required. Make: To be approved by engineer in charge before installation. For Outdoor Unit (BHF Kit)
4
-
-
Refrigerant Piping
-
-
-
Supplying & Installation of interconnecting following sizes of one end expanded refrigerant copper pipe of following outer diameter, insulated with closed cell electrometric nitrile rubber tubular insulation Class'O' between each set of indoor & outdoor units, all piping inside the building shall be propelrly fixed/supported with suitable size of clamp/ M.S. hanger and all external piping shall run in cable tray (Price Extra) etc. as reqd. (The final refrigerant pipe sizes shall be as per manufacturer). 22.2 mm dia with 19mm thick insulation
150
-
-
Supplying & Installation of interconnecting following sizes of one end expanded refrigerant copper pipe of following outer diameter, insulated with closed cell electrometric nitrile rubber tubular insulation Class'O' between each set of indoor & outdoor units, all piping inside the building shall be propelrly fixed/supported with suitable size of clamp/ M.S. hanger and all external piping shall run in cable tray (Price Extra) etc. as reqd. (The final refrigerant pipe sizes shall be as per manufacturer). 15.9 mm dia with 13mm thick insulation
200
-
-
Supplying & Installation of interconnecting following sizes of one end expanded refrigerant copper pipe of following outer diameter, insulated with closed cell electrometric nitrile rubber tubular insulation Class'O' between each set of indoor & outdoor units, all piping inside the building shall be propelrly fixed/supported with suitable size of clamp/ M.S. hanger and all external piping shall run in cable tray (Price Extra) etc. as reqd. (The final refrigerant pipe sizes shall be as per manufacturer). 9.5 mm dia with 13mm thick insulation
250
-
-
Drain Piping
-
-
-
Providing and fixing of uPVC Piping complete with fittings, supports as per specifications and duly insulated with 6mm thick closed cell nitrile rubber insulation. Make: To be approved by engineer in charge before installation. 50 mm dia
250
-
-
Providing and fixing of uPVC Piping complete with fittings, supports as per specifications and duly insulated with 6mm thick closed cell nitrile rubber insulation. Make: To be approved by engineer in charge before installation. 40 mm dia
300
-
-
Providing and fixing of uPVC Piping complete with fittings, supports as per specifications and duly insulated with 6mm thick closed cell nitrile rubber insulation. Make: To be approved by engineer in charge before installation. 32 mm dia
300
-
-
POWER CABLES
-
-
-
Supply and Fixing of following sizes of XLPE/ PVC insulated Aluminium/Copper cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 3.5 C X70 sq.mm ( Aluminium Armoured)
150
-
-
Supply and Fixing of following sizes of XLPE/ PVC insulated Aluminium/Copper cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 4C x 6 sq.mm. Cu Armoured
100
-
-
Supply and Fixing of following sizes of XLPE/ PVC insulated Aluminium/Copper cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technical specifications. 3C x 2.5 sq.mm. Cu. (Unarmoured)
200
-
-
Supplying and fixing 8 way, TP&N, MCB distribution board, VTPN DB, 240 V, on surface/ recess complete as required. With 1 Incomer 4P 100Amp MCCB, for outgoing 6 Nos. 4P 40Amp MCB, 15 Nos. SP 16Amp MCB and all necessary arrangments. Double door dust and vermin proof, suitable luxes and glands for connections , incomiong and outgoing for Indoor and outdoor units.
1
-
-
Transmission & Control Wiring
-
-
-
Supply, installation, testing and commissioning of control cum trans-mission wiring of copper between indoor and outdoor unit in PVC Conduit. (2 core x 4.00 Sq mm)
300
-
-
Supply and charging of Refrigerant R-410A complete as required.
80
-
-
Supply of PCC Blocks or MS Stand for VRV/VRF Outdoor units complete in all respect.
4
-
-
GI Cable tray for installation and laying of cables, refrigrent pipe, drain pipe, wires etc, with different sections for different cables/pipes, the tray shall be sturdy, with all clamping, fastner, rivet, hole-past etc any other accessory as required for fixing of tray in ceiling/wall and cables/pipes, for neat installation. of the following width. 300mm
200
-
-
GI Cable tray for installation and laying of cables, refrigrent pipe, drain pipe, wires etc, with different sections for different cables/pipes, the tray shall be sturdy, with all clamping, fastner, rivet, hole-past etc any other accessory as required for fixing of tray in ceiling/wall and cables/pipes, for neat installation. of the following width. 150mm
100
-
-
SITC of following minimum capacity VRV/VRF Highwall type Indoor unit equipped with washable synthetic media pre filter, fan section with low noise fan /dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will beat air inlet conditions of 27Degree C DB and 19Degree CWB temperature. Including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class O tubular insulation /with Class O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines and one year warranty complete systam , for year parts warranty ,twelve year compressor warranty ,all accessories as per specifications etc. as required with 2TR Capacity(3 star).
8
-
-