Haridwar Roorkee Development Authority Tender
View complete overview of Uttarakhand HRDA Tender
Haridwar Roorkee Development Authority - HRDA Tender
Civil And Construction
Building Construction
Eprocure
Opening Date26 Jan 2024
Closing Date7 Feb 2024
Tender Amount₹ 58,17,000
Costs
EMD
₹ 1,41,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_HRDA_68294_1Bid Award Id
ViewTender No
4873_Front OfficeTender Authority
Haridwar Roorkee Development Authority ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:
74.09
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
14.53
-
-
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).
22.74
-
-
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
5.84
-
-
Centering and shuttering including strutting, propping etc. and removal ofform for : Foundations, footings, bases of columns, etc. for mass concrete
28.8
-
-
Centering and shuttering including strutting, propping etc. and removal ofform for : Suspended floors, roofs, landings, balconies and access platform
149.99
-
-
Centering and shuttering including strutting, propping etc. and removal ofform for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
149.33
-
-
Centering and shuttering including strutting, propping etc. and removal ofform for : Columns, Pillars, Piers, Abutments, Posts and Struts
88.76
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars
7605.82
-
-
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level
20.61
-
-
All works above plinth level upto floor V level
45.37
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
7.73
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
69.22
-
-
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Marble work
39.6
-
-
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S. tube
302.4
-
-
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
3
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :110 mm diameter
16.05
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler(110 mm)
6
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5 degree 110 mm bend
3
-
-
Shoe (Plain) 110 mm Shoe
3
-
-
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs,screwed with M.S. screws of required length including.
6
-
-
12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
270.43
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)
263.58
-
-
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
149.99
-
-
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water tinnable priming coat with cement primer
420.42
-
-
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
263.58
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete..
420.42
-
-
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
239.63
-
-
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of
Engineer-in-charge. Made of G.I. wire of dia 4 mm
23
-
-
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
4.95
-
-
Providing & fixing of Deck slabs in flooring - 16mm thick - full body - matt finish with application using leveller with adhesives and epoxy grouting complete in all respects as including labor per direction given by engineer in charge.
96.17
-
-
Providing & fixing of Doors & Windows - system aluminium - T6 grade metallic grey, Glass-ST167 complete in all respects including labor as per direction given by engineer in charge.
49.43
-
-
Providing & fixing of AHPL false ceiling - staircase block : 3-6 mm thick wooden AHPL pabels with metal framing complete in all respects including labor as per direction given by engineer in charge.
60.15
-
-
Providing & fixing of Surface light 3000K 12 watt each (lift lobbies)complete in all respects including labor as per direction given by engineer in charge.
18
-
-
Providing & fixing of Surface light 4000K 15 watt each (helpdesk)complete in all respects including labor as per direction given by engineer in charge.
8
-
-
Providing & fixing of Surface light 4000K 9 watt each (dispatch department)complete in all respects including labor as per direction given by engineer in charge.
8
-
-
Providing & fixing of 2-way wall washer light for staircase 3000K -6 watt each complete in all respects including labor as per direction given by engineer in charge.
12
-
-
Providing & fixing of Decorative wall light for staircase 3000K -18 watt each complete in all respects including labor as per direction given by engineer in charge.
6
-
-
Providing & fixing of Wall batten light for store under staircase - 4000K -12 watt each complete in all respects including labor as per direction given by engineer in charge.
2
-
-
Providing & fixing of Outdoor Wall light for outdoor store- 4000K -12 watt each complete in all respects including labor as per direction given by engineer in charge.
1
-
-
Providing & fixing of Outdoor 1 way Wall light - 3000K -6 watt each complete in all respects including labor as per direction given by engineer in charge.
4
-
-
Providing & fixing of Fans - 1200 mm sweep, silent operation, black body complete in all respects including labor as per direction given by engineer in charge.
6
-
-
Providing architecture & structure consultancy with supervision of construction work.
1
-
-
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
10.31
-
-
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :Of area 3 sq. metres and below
8
-
-
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material with in 50 metres lead as per direction of Engineer-in-charge.
55.26
-
-
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
28.01
-
-
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
93.59
-
-
WGSTLPT Point wiring in PVC conduit, with modular type switch. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
30
-
-
WGSTLMIDTC Twin Control point wiring in PVC conduit, with modular type switch: Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
3
-
-
WGSTLPP2 Power plug wiring in PVC conduit (2x4 sq. mm) Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
120
-
-
WGSTLSB Circuit/ submain wiring in PVC conduit: Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
200
-
-
WGSTLSB Circuit/ submain wiring in PVC conduit: Wiring fir curcuit/ submain wiring alongwith earth wire the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.4 X 6 sq. mm + 2 X 6 sq. mm earth wire
50
-
-
TLWGEC Telephone wiring in PVC conduit: Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
120
-
-
PVCCON S/F PVC conduit: Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including painting in case of surface conduit, or cuttting the wall and making good the same in case of recessed conduit as required. 25 mm
200
-
-
MB S/F metal boxes: Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75 mm X 75 mm X 60 mm deep
6
-
-
PTSWEB S/F modular type switch/ socket: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
20
-
-
PTSWEB S/F modular type switch/ socket: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
20
-
-
PTSWEB S/F modular type switch/ socket: Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet
6
-
-
MODFREB S/F modular type electronic fan regulator: Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
6
-
-
LPACCPT S/F light plug point modular type accessories: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
6
-
-
PPACCPT S/F power plug point modular type accessories: Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
6
-
-
CREB S/F ceilling rose: Supplying and fixing 3 pin, 5 amp. ceilling rose on the existing junction box/ wooden block including connection etc. as required
6
-
-
BRHOLD S/F brass holder: Supplying and flxing brass batten/angle holder including connection etc. as required.
8
-
-
ITCFFSUR ITC fluorescent fitting directly on surface: Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling / wall, including connection with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
10
-
-
ITCCFFC ITC ceiling fan with cover on fan box: Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq, mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
6
-
-
ITCEF450 ITC exhaust fan upto 450 mm sweep: Installation of exhaust fan upto 450 mm sweep in the existingopening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required.
2
-
-
LOUSHEF Fixing louvers/shutters for exhaust fan: Extra for fixing louvers/shutters complete with frame for a exhaust fan of all sizes.
2
-
-
PWTPMCBDB S/F TP MCB DB: Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
1
-
-
MCBTPIS S/F TP MCB isolator: Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissoning etc. as required. 63 amps
2
-
-
MCBC S/F 'C' curve, SP MCB Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
4
-
-
EARGIPL G.I earth plate elctrode: Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal/ coke and salt as required..
1
-
-
EARG125X6 S/L 25 mm x 5 mm G.I. earth strip in ground: Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
30
-
-