Garhwal Mandal Vikas Nigam Limited Tender
View complete overview of Uttarakhand GMVNL Tender
Garhwal Mandal Vikas Nigam Limited - GMVNL Tender
Coronavirus COVID 19
Eprocure
Opening Date16 Nov 2019
Closing Date19 Dec 2019
Tender Amount₹ 1,37,39,000
Costs
EMD
₹ 2,75,000Document Cost
₹ 4,720Tender Fee
Refer Documents
Summary
Construction And Repair / Maintenance Work At
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_GMVN_21112_1Bid Award Id
ViewTender No
GMVN-ENGG-DBS-1Tender Authority
Garhwal Mandal Vikas Nigam Limited ViewPurchaser Address
-Website
http://http://gmvnl.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, inishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).
66.7
-
-
... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
25.92
-
-
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
125.11
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
256.38
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
255.38
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts
288
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers
300.81
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform
517.06
-
-
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
13.47
-
-
... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
181.28
-
-
... More
Finishing with 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) complete with all material, labour T& P etc
2246.04
-
-
... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
2246.04
-
-
... More
25 mm thick Kota stone slab flooring over 20 mm (average) thick base of cement morta 1:4(1 cement: 4 coarse sand) laid over with base concrete and Jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete in all respect.
505.54
-
-
... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
1426.33
-
-
... More
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
840.47
-
-
... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
25.2
-
-
... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates
and similar works
1360.8
-
-
... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer . Fixing with carbon steel galvanised dash fastener of required dia and size.
4695.59
-
-
... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness,
including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: 10.14.1 Profile B Fixing with adjustable lugs with split end tail to each jamb
88.8
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with Silicone addhesive complete as per the architectural drawings and the directions of Engineer-in-charge . With float glass panes of 5.50 mm thickness
156.6
-
-
... More
Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4 mm wide aperture with matching wood beading
75.6
-
-
... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
172.35
-
-
... More
Providing and spreading RBM i.e., River Bed Material (treated as granular sub-base /base/surface course material) in uniform layers with motor grader on prepared surface with rotavator and compacting with smooth wheeled roller to achieve the desired density.
103.41
-
-
... More
CONSTRUCTION OF TOILET BLOCK
-
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 cement : 4 fine sand : 8 graded stone aggregate 40 mm cu.m nominal size)
1.64
-
-
... More
Providing and laying in position of Reinforced Cement Concrete Work of grade 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone cu.m aggregate 20 mm nominal size) upto plinth level excluding the cost of centring, shuttering, finishing and reinforcement
1.42
-
-
... More
Thermo- techanically Treated bar in Reinforcement for R.C.C. work including straightening, utting,bending, placingin position and binding all complete.
3.6
-
-
... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with
frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
3.15
-
-
... More
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
10.21
-
-
... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :Cement mortar 1:3 (1 cement : 3 coarse sand)
45.17
-
-
... More
Finishing 12 mm cement plaster of mix with 1:6 (1 cement : 6 fine sand)
176
-
-
... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
176
-
-
... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 13.41.1 New work (two or more coats) over and including water thinnable priming coat with cement primer
176
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
8.1
-
-
... More
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
68.92
-
-
... More
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
18
-
-
... More
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
2
-
-
... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
2
-
-
... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and
making good the walls and floors wherever required : 17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern
3
-
-
... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
3
-
-
... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
6
-
-
... More
Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore
4
-
-
... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.15 mm dia nominal bore
20
-
-
... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter
25
-
-
... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
25
-
-
... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 m thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
2
-
-
... More
Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia
2
-
-
... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel
primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
92.55
-
-
... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
500
-
-
... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
1
-
-
... More
BEAUTIFICATION OF CAMPUS
-
-
-
... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
5054.4
-
-
... More
25 mm thick Kota stone slab flooring over 20 mm (average) thick base of cement morta 1:4(1 cement: 4 coarse sand) laid over with base concrete (after dismantling of existing floor) and Jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete in all respect.
316
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
234
-
-
... More
LABORATORY
-
-
-
... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
2908.8
-
-
... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer after dismantling of existing window. Fixing with carbon steel galvanised dash fastener of required dia and size.
8023.76
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with Silicone addhesive complete as per the architectural drawings and the directions of Engineer-in-charge . With float glass panes of 5.50 mm thickness
161.6
-
-
... More
Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4 mm wide aperture with matching wood beading
161.6
-
-
... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : of area 3 sq. metres and below
76
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
323.19
-
-
... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) sqm 264.80
76.5
-
-
... More
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
76.5
-
-
... More
CLASS ROOM
-
-
-
... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates
and similar works
2804.22
-
-
... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer after dismantling of existing window. Fixing with carbon steel galvanised dash fastener of required dia and size.
9413.88
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with Silicone addhesive complete as per the architectural drawings and the directions of Engineer-in-charge . With float glass panes of 5.50 mm thickness
155.79
-
-
... More
Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4 mm wide aperture with matching wood beading
155.79
-
-
... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : of area 3 sq. metres and below
106
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
311.58
-
-
... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) sqm 264.80
101
-
-
... More
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
101
-
-
... More
LIBRARY
-
-
-
... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates
and similar works
692.64
-
-
... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer after dismantling of existing window. Fixing with carbon steel galvanised dash fastener of required dia and size.
2148.57
-
-
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with Silicone addhesive complete as per the architectural drawings and the directions of Engineer-in-charge . With float glass panes of 5.50 mm thickness
38.49
-
-
... More
Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4 mm wide aperture with matching wood beading
38.49
-
-
... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.1 Of area 3 sq. metres and below
23
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
76.95
-
-
... More
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the
walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) sqm 264.80
23
-
-
... More
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
23
-
-
... More
INTERNAL ELECTRIFICATION
-
-
-
... More
WGSTLMOD point wiring in pvc conduit , with modular type switch : wiring for light / fan point / call bell point with 1.5 sq.mm FR PVC insulated copper conductor core cable im surface recessed pvc conduit with modular switch , modular plate , suitable GF box abd earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc as required. Group A
130
-
-
... More
LPACCMOD S/F Light plug point modular type accesorries : each supplying and fixing suitable size GI box with modular plae and cover in front on surface and recess , including providing and fixing 3 pin 5/6 amps modular sockets outlet and 5/6 amps modular socket outlet and 5/6 amps modular switch, connecton ,painting etc. as required .(for light plugs to be used in non residentials buildings)
22
-
-
... More
PPACCMOD S/F power plug point modular type accessories : each supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular sockets outlet and 15/16 amps modular switch, connecton, painting etc. as required
16
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required -2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
120
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required -2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
50
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required -2 X 4 sq. mm + 1 X 4 sq. mm earth wire
20
-
-
... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)- 12 way, Double door
6
-
-
... More
Supplying and fixing 5 amps to 32 amps ratings , 240 volts, 'B' series, miniature circuit breaker suitable for lighting and other loads of following poles into the existing MCB DB complete with connections, testing and commissioning etc. as required.- Single pole
60
-
-
... More
Supplying and fixing of angle/battan holder fixed on suitable base , complete in all trespect
24
-
-
... More
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning, protective covering. Upto 35 sqmm
50
-
-
... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size MS box and earthing
the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
2
-
-
... More
S/F of ceiling Fan 1200mm(48") as approved by E/I ---complete in all resepct. Cartage, Labour Charges etc.
36
-
-
... More
Supplying and fixing of Industril Light L.E.D corrosion resistant unbrekable polycarbonet body dust and water proof 40Watt complete with Hanging arrangement by pipe/chain making connection, and complete with all respect, directed/approved by E/I.
36
-
-
... More
Supply and fixing of LED Bulb B22 7Watt Incuding GST
24
-
-
... More
Supplying of PVC insulated aluminium armoured served sheathed cable of 10 sqmm 4 core, complete in all respects Including GST, Cartage, Labour Charges etc.
50
-
-
... More
Supplying and fixing of Decorative LED tube light fitting 18W, 4 feet long including tube rod complete with making connection and complete with all respect directed/approved by E/I.
15
-
-
... More
Supply of fixingh of factory eired ISI/ ECRTIFIED LED street light 40 W Capacity pressure dia cast or extruded Aluminium housing with corrossion resistant polyster powder coated side entry type shall consist at separate and control gear campatoment thoughened glass energy afficenvy LP- 18 watt operation voltage 140-270 HZ freequency 140-270 V electronic driver with internal surge protection of 4 KV street light should be protected with short circuit open circuit Reverse polarity and automatic safe shut down after 300 V AC and below 100 V A.C as per direction by E/I complete in all respect.
6
-
-
... More
S/Fof Surface Mounted LED down Lighter with integrated driver suitable for 15 Watt LED 857S complete with Labour & making connection complete in all respect.
24
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements