Central Building Research Institute Tender
View complete overview of Uttarakhand CBRI Tender
Central Building Research Institute - CBRI Tender
Coronavirus COVID 19
Eprocure
Opening Date25 May 2019
Closing Date8 Jun 2019
Tender Amount₹ 60,50,177 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 1,15,300Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_CSIR_26569_1Bid Award Id
ViewTender No
193(520)EST/2019-20Tender Authority
Central Building Research Institute ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :In cement mortar
9
-
-
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Of area 3 sq. metres and below
15
-
-
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead Of area beyond 3 sq. metres (Rolling Shutter)
2
-
-
Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge.
360
-
-
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
2
-
-
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:Asbestos sheet
184
-
-
Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore
60
-
-
Dismantling of road gully chamber of various sizes including C.I. grating with frame including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead including refilling the excavated gap.
6
-
-
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
17
-
-
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
23
-
-
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
46
-
-
Providing Unskilled manpower for shifting of various old testing models and materials from construction site to specified space in the institute as per direction of Engineer-in-charge
20
-
-
Providing skilled manpower for shifting of various items, furneture,old testing models and materials from construction site to specified space & any other work instructed , directed and required in the institute site as per direction of Engineer-in-charge
6
-
-
Providing Tractor trolly for shifting of malba, debrise, soil, various old testing models and materials from construction site to outside of institute and out site area of nagar nigum Roorkee including loading unloading complete work in all respect as per direction of Engineer-in-charge.
20
-
-
Boring with hydraulic piling rigs with power units, Providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :
-
-
-
300 mm dia piles
7
-
-
500 mm dia piles
60
-
-
Extra over single under ream for providing additional bulbs in under reamed piles ,under specified diameter. (only thenos. of extra bulbs are to be paid)
-
-
-
500 mm dia piles
12
-
-
Earth Work in excavation by mechanical / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm. on plan) including dressing sides and ramming of bottoms, lift up to 1.5 including getting out the excavated soil as directed.
All kinds of soils.
35
-
-
Filling available excavated earth ( excluding rock) in trenches, plinth side of foundation etc. in layer not exceeding 20Cm. in depth , consolidating each deposited layer by ramming and watering, lead up to 50m and lift up to 1, 5m.
16
-
-
Supplying and filling in plinth with sand under floor including watering consolidating and dressing Complete.
20
-
-
Providing and laying in position Cement Concrete of specified grade excluding the cost of centering and Shuttering-All workup to plinth level, mix 1:4:8 (1Cement : 4 coarse sand : 8 graded stone aggregate, 40mm nominal size ).
30
-
-
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smoothes.
9
-
-
Supplying chemical emulsion in sealed containers including delivery as specified
41
-
-
Diluting and injecting chemical emulsion for PRE-CONTRUCTIONAL Anti termite treatment (excluding the cost of chemical emulsion ) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor.
308
-
-
Reinforced cement concrete all work up to plinth level mix 1:1.5:3 in (1 cement :1.50 coarse sand :3 graded stone aggregate 20mm nominal size) (excluding cost of centering, shuttering, finishing and reinforcement.
17
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses,fillets, columns, pillars, piers , abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering ,finishing and reinforcement1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone cu.m aggregate 20 mm nominal size)
10
-
-
Reinforced cement concrete work in beams suspended floors roofs having slope up to 15 landings balconies, shelves, chajjas, lintels, bands, plain window sills, stair cases up to floor five level excluding cost of centering, shuttering, finishing and Reinforcement.(1 cement :1.50 coarse sand :3 graded stone aggregate 20mm nominal size)
24
-
-
Centering shuttering i/c strutting, propping etc. and removal of from for.
-
-
-
Foundations and footings
36
-
-
Suspended floors, roofs, landing, balconies and access platform.
120
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
109
-
-
Columns, pillars, piers, Abutments, posts and Struts.
84
-
-
Reinforcement for RCC work including straightening, cutting bending, placing in position and binding all complete : (Fe-500)
60
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
3
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
22
-
-
Half brick masonry with bricks of class designation 75 in super structure, above plinth up to floor two level in cement mortar1:4 (1 cement : 4 coarse sand).
40
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
388
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
-
-
-
For shutters of doors, windows & ventilators (Openable Portion) including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) :-
-
-
-
Powder coated aluminium (minimum thickness of powder coating 50 micron)
816
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
27
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasketetc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.0 mm thickness
35
-
-
Providing and fixing M.S. fan clamp of I or II of 16 mm dia M.S bar bent to shape with hocked ends in RCC slabs, beams during laying including painting the exposed portion of loop. All as per standared design complete.
4
-
-
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
-
-
-
125 mm
30
-
-
100 mm
40
-
-
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete
-
-
-
250x10 mm
32
-
-
150x10 mm
80
-
-
Providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
10
-
-
Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper.
16
-
-
Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frameand diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset platesat the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle andT-iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer.
3
-
-
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer
8
-
-
Panting with synthetic enamel paint on wood and Steel work of approved Brand and manufacture .to give an even shad two or more coats on new work
298
-
-
6 mm thick cement plaster on ceiling with cement mortar 1:3 (1 cement: 3 fine sand).including scaffolding etc. complete
204
-
-
12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand)including scaffolding etc. complete
123
-
-
15 mm thick cement plaster rough side brick work 1:6 cement mortar(1cement :6 coarse sand) including scaffolding etc. complete
139
-
-
Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
252
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
39
-
-
Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with Udaipur green marble.
136
-
-
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry complete.
56
-
-
Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thick
84
-
-
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.18 mm thick
4
-
-
Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete
2
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
1366
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
1366
-
-
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work
1366
-
-
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour and shade Area of slab over 0.50 sqm
10
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
8
-
-
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x510 mm bowl depth 200 mm
1
-
-
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete 25 to 40 mm nominal bore
1
-
-
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms
1
-
-
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
1
-
-
Providing and fixing vertical vancing blind (Regular) 100mm size of MAC or equivalent in required colur as approved by the engineer-in-charge complete. In all respect including operating system, carriage and wastage etc.
22
-
-
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
33
-
-
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Internal work - Exposed on wall 15 mm dia nominal bore.
80
-
-
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Internal work - Exposed on wall 40 mm dia nominal bore.
20
-
-
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. :-80 mm dia nominal bore
12
-
-
Providing Fixing CP Brass bib cock of appoved quality confurming to IS 8931 15 mm nominal bore
2
-
-
Providing fixing CP Brass Stop cock (Concealed) of standred design appoved make quality confurming to IS 8931 15 mm nominal bore
2
-
-
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design In 75x75 mm deep chase
40
-
-
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete
4
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter
32
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
4
-
-
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length,including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm
24
-
-
Grading roof for water proofing treatment withCement mortar 1:3 (1 cement : 3 coarse sand).
3
-
-
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet hould have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by ngineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
320
-
-
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)
13
-
-
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
1249
-
-
Providing, laying and fixing 150mm dia PVC pipes (standred make approved quaility) using PVC Socket,bends elbow and all necessary fitting etc. including jointing with adhesive with testing of joints etc. complete as per direction of engineer-in-charge.
30
-
-
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the doorframe to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge Extruded section profile size 48x40 mm.
31
-
-
Providing and fixing to existing door frames.25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places.
9
-
-
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per directions of Engineer-In-Charge.With cement mortar 1:4 (1 cement : 4 fine sand)
57
-
-
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
900
-
-
Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary 50 mm
8
-
-
Providing and fixing bright finished brass handles with screws etc. complete: 100 mm
16
-
-
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :100x10 mm
8
-
-
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. Complete Double strip (horizontal type)
8
-
-
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
210
-
-
Taking out carefully old electrical TPN Control panel Board installed in workshop( TSG Group) including disconnecting of cables and shifting of old Panel Board including old electric point wiring, sub-main, switch board, Panel board, Power Points and electrical fitting & fixture including all other old electrical items taken under renovation area of workshop( TSG Group )complete in all respect and shifting of old materials as required and directed by engineer -Incharge
1
-
-
Wiring for light Point /fan point exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit with modular switch of Havells Modular /Legrand MOSAIC / Anchore ROMA/ Make ,ISI marked, modular plate suitable G.I Box and earthing the point with 1.5 sq mm FRLS PVC insulated multi strand copper conductor single core cable of Polycab/Havell’s /KEI Cables /RR Kable/Finolex make I.S.I. marked 1100 volts grade as required for Group ‘C’ including ceiling rose and lamp holder as required
55
-
-
Supply and fixing 5/6 Amps Modular type switch on the existing Modular plate & switch box including connections but excluding modular plate etc. as required
8
-
-
S/F 8 module GI box of size 125 x 125 mm along with modular base and cover plate for modular switches in recess etc as required and directed by Engineer- in –charge
1
-
-
Suppling and fixing 3 pin 5 aims celing rose on the existing junction box /wooden block including conection etc as required
8
-
-
Wiring for circuit /sub-main wiring along with earthwire the following size of FRLS PVC Insulated multi standard copper conductor single core cable of Polycab/Havell’s /KEI Cables /RR Kable/Finolex make I.S.I marked 1100Volts grade in surface/ recessed steel conduit as required
-
-
-
2 x 1.5 sqmm + 1 x 1.5 sqmm earth wire
100
-
-
2 x 2.5 sqmm + 1 x 2.5 sqmm earth wire
600
-
-
2 x 4 sqmm + 1 x 4 sqmm earth wire
500
-
-
2 x 6 sq.mm + 1 x 6 sq mm earth wire
90
-
-
4 x 6 sq.mm + 2 x 6 sq mm earth wire
65
-
-
4 x 10 sq.mm + 2 x 10 sq mm earth wire
60
-
-
Supply and fixing suitable size G.I Box with modular plate and cover in front on surface/recessed including P/F 5 pin 5/6 Amps modular socket outlet and 5/6Amps modular switch of Havells Modular /Legrand MOSAIC / Anchore ROMA/ Make ,ISI marked, connections painting etc as required
45
-
-
Supply and fixing suitable size G.I Box with modular plate and cover in front on surface/recessed including P/F 6 pin 15/16 Amps and 5/6 Amps modular socket outlet and 15/16Amps modular switch of Havells Modular /Legrand MOSAIC / Anchore ROMA/ Make ,ISI marked, connections painting etc as required
45
-
-
Supply and fixing 20 amps 240 Volts SPN industrial type socket outlet with two pole and earth metal enclosed plug top along with 32 Amps ‘C’ series SP MCB in sheet steel enclosure on surface or in recesses with chained metal cover for the socket outlet complete with connection, testing, commissioning etc. as required and directed by Engineer-in-charge. Havells / Legrand /L&T/ Sciemense Make .
6
-
-
Supply and fixing 30 amps 415 Volts TPN industrial type socket outlet with four pole and earth metal enclosed plug top along with 32 Amps ‘C’ curve, TPMCB in sheet steel enclosure on surface or in recesses with chained metal cover for the socket outlet complete with connection, testing, commissioning etc. as required and directed by Engineer-in-charge. Havells / Legrand /L&T/ Sciemense Make .
3
-
-
S/F Two module Stepped type electronic fan regulator on existing modular plate switch box including connections but excluding modular plate etc as required and directed by the Engineer –in-charge
4
-
-
Supply and fixing factory wired Havells make Stout LED Light battens 0f 40 watt including suitable size M.S.Patti cat.no. LHEYBYP 70 E1 W 040 or its equivalent make of Bajaj/Phillips make complete in all respect as required and directed by engineer incharge
36
-
-
Supply and fixing 1400 mm sweep double ball bearing type heavy duty ceiling fan of Havells make model velocity/velocity HS or equivelent of cinni/ crompton make complete in all respect as required and directed by the Engineer –in-charge.
4
-
-
S/F LED Street Light fixture of new generation energy saving and environmental friendly long life LED Street Light made up of pressure die cast aluminium housing with high power LEDas lighting source and lens embedded PC cover having TOP OPENING seprate driver compartment with ,IP66 protection and impact resistance of IK07 with 10 KV Built-in Surge protection Device of Havells make 70 Watt 230 volts odering code ENDURAPEARLPLUSSL70WLED757SASYTOPC or its equivalent make of Bajaj/ Phillips make complete as required
6
-
-
Supplying & Fixing of 32 mm diax1.00 meters long G.I. pipe(medium class) bracket for mounting of Havells make 48 Watt 230 volts odering code LHET AXU7 PA6W048 or its equivalent make of Bajaj/ Phillips make street light fitting on wall including bending the pipe to the required shape,40mmx3mm flate iron clamp and wiring with1.5 sq.mm wp/pvc wire and painting the flate iron with primer and finish paint etc. as required
4
-
-
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required.
30
-
-
Supply and Fixing 8Way double door surface/recess mounting vertical type 415 voltsTPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bars, common neutral link, earthbar, dinbar for mounting MCB’s (But without MCBs and incomer MCCB)of Havells make model load line or its equivalent of Legrand/ABB /L&T/ Sciemense Make including painting earthing etc. as required and directed by Engineer-in Charge
3
-
-
Providing and fixing 100 amps 16 KA rating and breaking capacity three pole MCCB in existing cubical panel board including drilling holes in cubical panel making connection etc. including testing and commissioning. as required by Engineer-in charge of Legrand/ Havells /L&T/ Sciemense Make make.
9
-
-
Supply and fixing 5amps- 32 amps rating 240/415 Volts C series miniature circuit Breaker suitable for inductive loads of following pole in the existing MCB DB complete with connections, testing and commissioning etc as required and directed by Engineer-in-charge Legrand/ Havells /L&T/ Sciemense Make
-
-
-
Single Pole
50
-
-
Triple Pole
14
-
-
S/F 12 way double door single pole and neutral sheet steel MCB distribution Board 240 volts on surface /recess complete with tinned copper Bus –Bar Neutral Bus-Bar earth bar din-bar detachable gland plate interconnections,phosphatised and powder painting including earthing etc as required (But without MCB/RCCB/Isolation) Havells /Legrand make
2
-
-
S/F 63 Amps rating double pole 240 volts isolator in the existing MCBDB complete with connections testing and commissioning etc as required.. Havells /Legrand make
2
-
-
Supply and fixing 400 mm sweep oscillating type wall mounting fan of crompton (SDX)/Havells(Platina) make complete in all respect as required and directed by the Engineer –in-charge.
12
-
-
Providing and Laying 6 SWG G.I. wire at 0.5 m below ground level for conductor earth electrode including connection ter mination with G.I. thimble etc. as required.
50
-
-
Supply, installation and commissioning of surface / recesses mounting Havells Make Industrial Type MCCB distribution board,Enclouser model POWER SAFE cat.no.IHVG040008 frame panel board suitable for mounting 250AmpsTP/TPN G Frame MCCB as incomer, outgoing number of 6 Ways is the number of G Frame TP MCCB;S of 100Amps (without MCCBs) of L&T/Havell’s/ Legrand make. Incluiding Pre-Wired Digital Meter Module cat.no. ISSBOU0711 and including cable Alley cat no.ISSBOU0682 for ‘G’ Frame panel boards & Indicating including indicating Lights complete in all respect as required and directed by the Engineer –in-charge
1
-
-
Providing and fixing 250 amps 25 KA rating and breaking capacity Three Pole MCCB in existing cubical panel board including drilling holes in cubical panel making connection etc. including testing and commissioning. as required by Engineer-in charge of Legrand/ Havells /L&T/ Sciemense Make make.
1
-
-
Supply for installation of 450 mm sweep Havells make heavy duty exhaust fan model turbo force in metal body complete in all respect as required
1
-
-
Installation of exhaust fan up to 450 mm sweep in the existing opening, including making good the damage, connections, testing and commissioning etc as required.
1
-
-
Supply and fixing 450 mm sweep exhaust fan louvers made of G.I sheet complete in all respect as required.
1
-
-
Supplying and making indoor end termination with brass compression gland and aluminium lugs for 3.5 x 50 sq.mm(35 mm )size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
6
-
-
Supplying, installation,Testing and commissioning of Split type Air Conditioners of 2 TR capacity of L.G./ Voltas/ Carrier/Panasonic/Daikin/Hitachi Make with remote control and 3 star labeled by BEE suitable for operation on 230 volts 50 HZ AC Power Supply including refrigerant copper tubing/piping with insulation of required length as per site requirement wall breacket for mounting out door unit including supply and installation of wall mounted Voltage Stabilizer of V- Gaurd/Bluedart/Capri Livgaurd/LEISTUNG TECHNOLOGY make of 140-280 volts input and output 210-230 volts range of capacity not less than 5 KVA complete in all respect as required and directed by Engineer –in-charge.
3
-
-
Supply and fixing of 250 mm sweep Havells make plastic body exhaust fan model ventil air-DX or its equivalent of Crompton Greaves Make model BRISK AIR complete in all respect as required
2
-
-
Re-lettering with black japan paint of approved brand and manufacture
500
-
-