Central Building Research Institute Tender
View complete overview of Uttarakhand CBRI Tender
Central Building Research Institute - CBRI Tender
Civil And Construction
Building Construction
Eprocure
Opening Date27 May 2022
Closing Date7 Jun 2022
Tender Amount₹ 12,59,749 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 25,200Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_CSIR_117087_1Bid Award Id
ViewTender No
193(605)EST/2022-23Tender Authority
Central Building Research Institute ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
1
-
-
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
34
-
-
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge
1
-
-
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below
4
-
-
Providing Tractor trolly for shifting of malba, debrise, soil, various old testing models and materials from construction site to outside of institute and out site area of nagar nigum Roorkee including loading unloading complete work in all respect as per direction of Engineer-in-charge.
4
-
-
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m All kinds of soil.
57
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
23
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
6
-
-
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
15
-
-
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
5
-
-
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
95
-
-
Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thick
95
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
2
-
-
Brick work in superstructure of class designation 75 in Cement mortar 1:6 (1 Cement : 6 coarse sand).
3
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
16
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
14
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
2
-
-
Centering and shuttering including strutting, propping etc. and removal of form for :
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete
22
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers
20
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Cold twisted bars
1256
-
-
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand
28
-
-
15 mm thick cement plaster rough side brick work 1:6 cement mortar(1cement :6 coarse sand) including scaffolding
20
-
-
Repairs to plaster of thickness 12 mm to 20 mm in patches of area2.5 sq.meters and under, including cutting the patch in proper shape,raking out joints and preparing and plastering the surface of the wallscomplete, including disposal of rubbish to the dumping ground, allcomplete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand)
49
-
-
Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm)
48
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
56
-
-
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
6
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
2785
-
-
Providing and fixing bolts including nuts and washers complete.
27
-
-
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
69
-
-
Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
2
-
-
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
65
-
-
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
108
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer
147
-
-
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work
147
-
-
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface
105
-
-
Wiring for light Point/ fan point/ exhaust fan point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit with modular switch of Havell’s/ Modular Legrand Mosaic/ Anchor ROMA make ISI marked, modular plate suitable G.I Box and earthing the point with 1.5 sq mm FRLS PVC insulated multi strand copper conductor single core cable of Polycab/ Havell’s/ Rallison/KEI/ RR kable and Phenolex make ISI marked 1100 V grade as required for group ‘C’ Point including ceiling rose or lamp holder as required.
17
-
-
Wiring for circuit /sub-main wiring along with earth wire the following size of FRLS PVC Insulated multi standard copper conductor single core cable of Polycab/ Havell’s/ KEI/ RR kable and Phenolex make 1100 V grade ISI marked in surface/ recessed steel conduit as required.
-
-
-
2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire
280
-
-
2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
70
-
-
2 x 4 sq.mm + 1 x 4 sq.mm earth wire
165
-
-
2 x 6 sq.mm + 1 x 6 sq.mm earth wire
12
-
-
4 x10 sq.mm + 2 x 6 sq.mm earth wire
10
-
-
4 x16 sq.mm + 2 x 6 sq.mm earth wire
15
-
-
Supplying and fixing following size/ modules,GI box along with modular base & cover plate for modular switches in recess etc. as required.
-
-
-
2 Module (75mmX75mm)
4
-
-
3 Module (100mmX75mm)
6
-
-
6 Module (200mmX75mm)
2
-
-
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate etc. as required.
2
-
-
Supplying and fixing 5/6 A modular type switch on the existing Modular plate and switch box including connections but excluding modular plate etc. as required.
17
-
-
Supplying and fixing of 3 pin 5 A ceiling rose on the existing junction box / wooden block including connections etc as required.
16
-
-
Supplying and fixing suitable size G.I Box with modular plate and cover in front on surface /recessed, including P/F 6 pin 15/16 A and 5/6 A modular socket outlet and 15/16 A modular switch of Havells Modular /Legrand MOSAIC /Anchore ROMA /Make ISI marked connections painting etc as required.
6
-
-
Supplying and fixing 30 / 32 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal inclosed plug top along with 30A “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
2
-
-
Supplying and fixing factory wired Havells make stout LED light battens of 40 watt including suitable size M S patti Cat. No. LHEYBYP 70 E1W 040 or its equivalent make of Bajaj / Phillips complete in all respect as required directed by engineer incharge.
12
-
-
Supplying and fixing of blub holder 14 watt LED lamp of Havells or its equivalent make of Bajaj/Philips including connection etc. as required.
2
-
-
Supplying and fixing of 450 mm sweep wall fan Havells make plastic body pedestal fan Sphint HS or its equivlant make of Cromption / bajaj/ Philips in all respect as required and directed by engineer incharge.
2
-
-
Supplying and fixing of 400 mm sweep Havells make plastic body pedestal fan Sphint HS or its equivlant make of Cromption / bajaj/ Philips in all respect as required and directed by engineer incharge.
1
-
-
Supply and installation of 300 mm sweep Havells make metal body exhaust fan modal turbo force SP or its equivalant of crompton make complete in all respect as required.
1
-
-
Supply and fixing 4 Way double door surface / recess mounting vertical type 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, dinbar for mounting MCB’s (But without MCBs and incomer MCCB) of Havells make model LOAD LINE or its equivalent of Legrand/ ABB/ L&T and Sciemense Make including painting earthing etc. as required and directed by engineer incharge.
1
-
-
Supplying and fixing 5A – 32A rating 240/415 V, C series MCB suitable for inductive loads of following pole in the existing MCB DB complete with connection, testing and commissioning etc. as required and directed by engineer incharge of Legrand / Havells / L&T / Sciemence make
-
-
-
Single Pole MCB
12
-
-
Triple Pole MCB
4
-
-
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required :-
-
-
-
Above 35 sq. mm and up to 95 sq. mm (Clamped with 25/3 mm) MS flat clamp
30
-
-
Supplying and making end termination with brasscompression gland and aluminium lugs for 3.5 core 50 sq. mm.
6
-
-
Supplying for laying in existing trench PVC insulated and PVC sheathed XLPE armoured heavy duty 1.1 KV grade Grandle / Gemcab/ Kalinga/ Havell’s / Rallison and KEI make ISI marked heavy duty, aluminium conductor electric cable as per latest I. S. specification , including connection testing etc. complete in all respect as required and directed by engineer incharge following size : 3.5 core, 50 sq.mm
30
-
-
Providing and fixing 32 A TP&N disconnector FSU unit inside the existing panal board with ISI marked HRC fusesincluding drilling holes in cubical panel, making connection etc. as required.
3
-
-
Providing and fixing 63 A TP&N disconnector FSU unit inside the existing panal board with ISI marked HRC fusesincluding drilling holes in cubical panel, making connection etc. as required.
1
-
-
Providing and fixing 100 A TP&N disconnector FSU unit inside the existing panal board with ISI marked HRC fusesincluding drilling holes in cubical panel, making connection etc. as required.
1
-
-
Supplying and fixing of M.S. box / Load line MCCB enclosure suitable for fixing up to 100/ 15 A MCCB of Havells make Cat. No. IHEATP or its equivlqnt make of Legrand / L&T / Scimence / ABB for make of housing three pole MCCB including suitable size opening for knob of MCCB for operation as required.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements