Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited Tender
View potential partner for Uttarakhand BRIDCUL Tender
Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited - BRIDCUL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 Apr 2025
Closing Date5 May 2025
Tender AmountRefer Documents
Costs
EMD
₹ 88,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_BRID3_82794_3Tender No
797/BRIDCUL/988/1/25 Dated 09.04.2025Tender Authority
Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
37
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2920
-
-
... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1085
-
-
... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.(20)
-
-
-
... More
2 Pair
230
-
-
... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
... More
20mm (T.V+Telephone+Network)
225
-
-
... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
70
-
-
... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
-
-
-
... More
1 or 2 Module (75 mmX75 mm)
16
-
-
... More
3 Module (100 mmX75 mm)
10
-
-
... More
4 Module (125 mmX75 mm)
10
-
-
... More
6 Module (200 mmX75 mm)
20
-
-
... More
8 Module (125 mmX125 mm)
16
-
-
... More
12 Module (200 mmX150 mm)
6
-
-
... More
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
-
-
-
... More
1 or 2 Module
18
-
-
... More
3 Module
10
-
-
... More
4 Module
10
-
-
... More
6 Module
20
-
-
... More
8 Module
16
-
-
... More
12 Module
8
-
-
... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
115
-
-
... More
Supplying and flxing brass batten/angle holder including connection etc. as required.
75
-
-
... More
Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/ LED lamps per fitting, complete with all accessories including connections etc. as required.
443
-
-
... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
26
-
-
... More
Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required.
120
-
-
... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
206
-
-
... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
70
-
-
... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
-
-
-
... More
Upto 450 mm sweep
19
-
-
... More
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
19
-
-
... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
... More
1 run of cable
80
-
-
... More
2 run of cable
50
-
-
... More
3 run of cable
140
-
-
... More
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator)
-
-
-
... More
12 way (4 + 36), Double door
2
-
-
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
Single pole
158
-
-
... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
... More
40 amps
4
-
-
... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
9
-
-
... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
5
-
-
... More
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
70
-
-
... More
Supply of AC 230/250 volts, 50 HZ exhaust fans including providing nuts, bolts, mounting frame and other accessories etc. complete. 300 mm sweep 900 rpm
19
-
-
... More
Supply of type fluorescent tube light fitting suitable for 1*18w fluorescent tube complete including tubes etc. on surface complete in all respects.
206
-
-
... More
Supply of SYSKA Self Ballasted LED Lamps for General Lighting Service 12 Watts 4 Star complete including tubes etc. on surface complete in all respects.
75
-
-
... More
Supply of LT XLPE PVC aluminium Unarmoured cable 50 Sq.mm 4core 1100 volt.
180
-
-
... More
Supply of LT XLPE PVC aluminium Unarmoured cable 150 Sq.mm 4core 1100 volt.
80
-
-
... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
6
-
-
... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
105
-
-
... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 6 mm thick copper base plate including holes etc. complete as required.
2
-
-
... More
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
2
-
-
... More
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
80
-
-
... More
Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
35
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
-
-
-
... More
Above 35 sq. mm and upto 95 sq. mm
180
-
-
... More
Above 95 sq. mm and upto 185 sq. mm
80
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 50 sq. mm (35mm)
24
-
-
... More
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.Above 4.5 metre and upto 6.5 metre
8
-
-
... More
Supply of ADP Octagonal Pole single Arm 6 m. height. Compitable for post top range. as approved by Engineer in charge with making connection complete in all respect. poles with single bracket
6
-
-
... More
Supply & Installation of Photonics 6 30 watt white LED Type approved by Engineer in charge complete in all respect.
6
-
-
... More
MAIN LT PANNEL
-
-
-
... More
Supply and erection of factory fabricated and wired metal clad dust and vermin proof Cubical panel MCCB complete with the MCB and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of Digital type ammeter, voltmeter, and selector switches for ammeter and voltmeter, instrument fuses, current transformer etc. The board shall have suitable capacity electrolytic aluminum bush bars as per IS8623 isolated with heat shrink sieving and mounted on non hygroscopic supports such as CMC/DMC support with detachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes. reverse entry boxes in The switches board shall be fabricated with CRCA sheet with a minimum thickness of 2 mm cubicle type. A-Incoming- 600 Amp MCCB- 1 No.,4p,36 KA, B-Outgoing- 300 Amp MCCB-2 No.,4p, 25 KA, 10 A MCB -1 No
1
-
-
... More
Supply and erection of factory fabricated and wired metal clad dust and vermin proof Cubical panel MCCB complete with the MCB and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of Digital type ammeter, voltmeter, and selector switches for ammeter and voltmeter, instrument fuses, current transformer etc. The board shall have suitable capacity electrolytic aluminum bush bars as per IS8623 isolated with heat shrink sieving and mounted on non hygroscopic supports such as CMC/DMC support with detachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes. reverse entry boxes in The switches board shall be fabricated with CRCA sheet with a minimum thickness of 2 mm cubicle type. A-Incoming- 300 Amp MCCB- 1 No.,4p,36 KA, B-Outgoing- 25 Amp MCCB-4 No.,4p, 25 KA, 16 A MCB -4 No,FP 32 A MCB -4 No,DP,
2
-
-
... More
Supply and erection of factory fabricated and wired metal clad dust and vermin proof Cubical panel MCCB complete with the MCB and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of Digital type ammeter, voltmeter, and selector switches for ammeter and voltmeter, instrument fuses, current transformer etc. The board shall have suitable capacity electrolytic aluminum bush bars as per IS8623 isolated with heat shrink sieving and mounted on non hygroscopic supports such as CMC/DMC support with detachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes. reverse entry boxes in The switches board shall be fabricated with CRCA sheet with a minimum thickness of 2 mm cubicle type. A-Incoming- 500 Amp MCCB- 1 No.,4p,36 KA,B-Outgoing- 250 Amp MCCB-2 No.,4p, 25 KA, 10 A MCB -1 No
1
-
-
... More
Supply and erection of factory fabricated and wired metal clad dust and vermin proof Cubical panel MCCB complete with the MCB and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of Digital type ammeter, voltmeter, and selector switches for ammeter and voltmeter, instrument fuses, current transformer etc. The board shall have suitable capacity electrolytic aluminum bush bars as per IS8623 isolated with heat shrink sieving and mounted on non hygroscopic supports such as CMC/DMC support with detachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes. reverse entry boxes in The switches board shall be fabricated with CRCA sheet with a minimum thickness of 2 mm cubicle type. A-Incoming- 250 Amp MCCB- 1 No.,4p,36 KA,
B-Outgoing- 25 Amp MCCB-5 No.,4p, 25 KA, 16 A MCB -1 No,FP 32 A MCB -3 No,DP.