Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited Tender

Take tender evaluation notes for Uttarakhand BRIDCUL Tender

Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited - BRIDCUL Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 Mar 2025
Closing Date26 Mar 2025
Tender Amount₹ 2,32,65,000 
Notes
Download

AI Insights

Class Of Bidder
... View More
The class eligibility requirement to bid or participate in this tender is that the contractors must be registered with BRIDCUL. The specific class of contractor is not explicitly mentioned.

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying and Fixing of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge.

4

-

-

... More
Supplying and Laying of Rubber mat 1000 mm. Wide to withstand 11 KV dielectric strength as per latest IS 15652-2006 etc. as reqd.

2

-

-

... More
supply and fixing of ABC type fire extinguishers capacity 9kg MAP 50 suitable for all kind of fire.

2

-

-

... More
supply and fixing of Co2 type fire extinguishers capacity 4.5 kg gas based suitable for Electric kind of fire.

2

-

-

... More
Supply of 3 core stranded aluminium conductor 11KV grade XLPE (E) (Cross linked Polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cable confirming to IS : 7098 (part II with latest amendments). Make. Kei, Havells, Polycab or Eq

-

-

-

... More
70 sq. mm 3 core

250

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required

-

-

-

... More
upto 120 sq. mm

250

-

-

... More
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of, XLPE aluminium conductor cable of 11 KV grade as required

-

-

-

... More
70 sq. mm

2

-

-

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :

-

-

-

... More
70 sq. mm

2

-

-

... More
Supply installation testing and commissioning of LT panel Board for the extension of existing panel as per the following specification with proper copper earthing as recommended. The panel should be Designed as per the latest standard IEC 61439. The panel should have Bus bar clearance of 25 mm for Ph to Ph and 19 mm for Ph to neutral, Zero Stray voltage doors and panels, polyester glass support for insulation. The cable alleys should be 300 mm wide and it should be fitted with hinged door that open up to and angle of 95 Deg. The provision of cable entry should be from Bottom. The IP protection of panel should be IP-42 for external and IP2X for internal with 3B as Form of separation. The panel should be equipped with suitable size of CT and display meter for VAF measurement. The panel should be suitable for seismic zone V. Make of panel: L&T (Ti), ABB (ArtuK), Schneider (OkEN)

-

-

-

... More
LT Outgoing should be IP 54 and should have switchgears as below. Make of LV switchgear : L&T (Lauritz & Knudsen), Schneider or Siemens.

-

-

-

... More
INCOMER:-

-

-

-

... More
1 No 630 Amp. 4P MCCB of 35KA (Ics=Icu) Breaking Capacity

-

-

-

... More
1 No. Multi Function Meter.

-

-

-

... More
1 No. CT FOR APFC PANEL

-

-

-

... More
1 Set of phase indicating lamps with Single Pole MCB.

-

-

-

... More
1 Set of ON / OFF indicating lamps with Single Pole MCB.

-

-

-

... More
1 Set 50,50N,51,51N,27,32,49,59,86,95 CT's control.

-

-

-

... More
BUS BARS:-

-

-

-

... More
800 Amps. TP&N aluminium bus bars

-

-

-

... More
OUT GOINGS:-

-

-

-

... More
2 Nos. 250 Amps. FP MCCB thermal magnetic release (25 KA)

-

-

-

... More
2 Nos. 100 Amps. FP MCCB thermal magnetic release (25 KA)

-

-

-

... More
3 Nos. 40 Amps. FP MCCB thermal magnetic release (25 KA)

-

-

-

... More
7 Nos. 32 Amps. DP MCB (10 KA)

-

-

-

... More
2 Nos. Space & Spare

1

-

-

... More
EXTERNAL LIGHTING PANEL

-

-

-

... More
INCOMER:-

-

-

-

... More
1 No 40 Amp. 4P MCCB of 25KA (Ics=Icu) Breaking Capacity

-

-

-

... More
1 No. Multi Function Meter.

-

-

-

... More
1 Set of phase indicating lamps with Single Pole MCB.

-

-

-

... More
1 Set of ON / OFF indicating lamps with Single Pole MCB.

-

-

-

... More
BUS BARS:-

-

-

-

... More
60 Amps. TP&N aluminium bus bars (25 KA)

-

-

-

... More
OUT GOINGS:-

-

-

-

... More
4 Nos. 32 Amps. FP MCB

-

-

-

... More
15 Nos. 16 Amps. DP MCB

-

-

-

... More
2 Nos. Space & Spare

1

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. Details of cost for one each

1

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

5

-

-

... More
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.

7

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required

2

-

-

... More
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.

50

-

-

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.

60

-

-

... More
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess for connections etc. as required.

210

-

-

... More
Supply of following size of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC shethed armoured cable as per IS 7098:1988 with up to date amendment. Make:- Kei, Havells & Polycab or Eq.

-

-

-

... More
3.5 x 300 sq.mm.

400

-

-

... More
3.5 x 120 sq.mm

200

-

-

... More
3.5 x 50 sq.mm

100

-

-

... More
4 x 10 sq.mm

100

-

-

... More
2 x 10 sq.mm,

250

-

-

... More
3 x 4 sq.mm,

600

-

-

... More
Supplying and making cable end terminations with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required.

-

-

-

... More
2 X 6 sq. mm (19mm)

50

-

-

... More
2 X 10 sq. mm (19mm)

10

-

-

... More
3½ X 50 sq. mm (35mm)

2

-

-

... More
3½ X 120 sq. mm (45mm)

4

-

-

... More
3½ X 300 sq. mm (70mm)

8

-

-

... More
4 X 10 sq. mm (25mm)

4

-

-

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.

-

-

-

... More
100mm dia

50

-

-

... More
150 mm dia

30

-

-

... More
250 mm dia

20

-

-

... More
300 mm dia

20

-

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.

-

-

-

... More
63 mm dia (OD-63 mm & ID-51 mm nominal)

200

-

-

... More
90 mm dia (OD-90 mm & ID-76 mm nominal)

200

-

-

... More
SUBHEAD - I :Solar Photovoltaic Power Plant

-

-

-

... More
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-

90

-

-

... More
a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.

-

-

-

... More
b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency.

-

-

-

... More
c) Data Monitoring System complete with accessories.

-

-

-

... More
d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.

-

-

-

... More
e) Lightning and surge voltage protection.

-

-

-

... More
f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.

-

-

-

... More
SUBHEAD - I :D.G. SETS

-

-

-

... More
Supplying, Installation and commissioning of AMF start silent type 25KVA DG set comprising of suitable BHP diesel engine directly coupled to 3 phase 50 Hz 415 V alternator of 25 KVA rating at 0.8 power factor mounted on a common base frame, complete in all respects with all required safety devices, fittings, batteries, accessories, filters, residential type silencer, control panel, inbuilt diesel oil MS tank capacity made of 2mm thick M.S. sheet complete with M.S. fuel piping, G.M. gate valves, supports, control cable between generating set and control panel, exhaust piping with asbestos roping, antivibration mounting pads, first filling of lubricant oil totally enclosed in air tight, dust proof, weather proof, powder coated cubical type, sound proof as per CPCB norms acoustic enclosure made of 2mm thick CRCA sheet with with heavy duty doors, lockable arrangement, sound proof insulation with high density rock/mineral polymer/fibre cloth and perforated CRCA sheets, suitable to reduce the sound level upto 75dba approx. at a distance of 1 mtrs. as per CPCB IV norms

-

-

-

... More
AMF Panel Incoming- 250 Amps FP MCCB of 25KA breaking capacity and contactor same rating

1

-

-

... More
Supplying, Installation and commissioning of AMF start silent type 100KVA DG set comprising of suitable BHP diesel engine directly coupled to 3 phase 50 Hz 415 V alternator of 100 KVA rating at 0.8 power factor mounted on a common base frame, complete in all respects with all required safety devices, fittings, batteries, accessories, filters, residential type silencer, control panel, inbuilt diesel oil MS tank capacity made of 2mm thick M.S. sheet complete with M.S. fuel piping, G.M. gate valves, supports, control cable between generating set and control panel, exhaust piping with asbestos roping, antivibration mounting pads, first filling of lubricant oil totally enclosed in air tight, dust proof, weather proof, powder coated cubical type, sound proof as per CPCB norms acoustic enclosure made of 2mm thick CRCA sheet with with heavy duty doors, lockable arrangement, sound proof insulation with high density rock/mineral polymer/fibre cloth and perforated CRCA sheets, suitable to reduce the sound level upto 75dba approx. at a distance of 1 mtrs. as per CPCB IV norms

-

-

-

... More
AMF Panel Incoming- 125 Amps FP MCCB of 25KA breaking capacity and contactor same rating

1

-

-

... More
Supplying, Installation and commissioning of AMF start silent type 40KVA DG set comprising of suitable BHP diesel engine directly coupled to 3 phase 50 Hz 415 V alternator of 40 KVA rating at 0.8 power factor mounted on a common base frame, complete in all respects with all required safety devices, fittings, batteries, accessories, filters, residential type silencer, control panel, inbuilt diesel oil MS tank capacity made of 2mm thick M.S. sheet complete with M.S. fuel piping, G.M. gate valves, supports, control cable between generating set and control panel, exhaust piping with asbestos roping, antivibration mounting pads, first filling of lubricant oil totally enclosed in air tight, dust proof, weather proof, powder coated cubical type, sound proof as per CPCB norms acoustic enclosure made of 2mm thick CRCA sheet with with heavy duty doors, lockable arrangement, sound proof insulation with high density rock/mineral polymer/fibre cloth and perforated CRCA sheets, suitable to reduce the sound level upto 75dba approx. at a distance of 1 mtrs. as per CPCB IV norms

-

-

-

... More
AMF Panel Incoming- 100 Amps FP MCCB of 25KA breaking capacity and contactor same rating

1

-

-

... More
SUBHEAD - I: CAMPUS LIGHTING

-

-

-

... More
Supply and fixing of hot dip galvanised steel OCTAGONAL POLE, Height=7m, Top OAF= 70 mm, Bottom OAF-130, Thickness - 3 mm,Base Plate - 220x220x12 mm , PCD - 220 mm

25

-

-

... More
Supply and fixing of foundation accessories for 7 mtr pole set-Each set consists of 4 nos. of M20x700 J bolts plus 10% templates

25

-

-

... More
Supply and fixing of 1000 mm Galvanized SINGLE Arm bracket , Standarad Type made of 48.3/32 mm OD pipe

25

-

-

... More
Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 70Watt. to 80 Watt and Confirming to IP66 protection having Company LOGO Engraved complete in all respect with 4000-5000 system lumens High Power LED with lenses, 110lm/W, PF0.95, THD 10% at full load, CRI70, Avg Life Class 50000Hrs@L70,fitting itself suitable for 60-65mm OD pipe

25

-

-

... More
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.

-

-

-

... More
Above 6.5 metre and upto 8.0 metre

25

-

-

... More
Supplying,installation,testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.

-

-

-

... More
1 output per phase and suitable for single phase supply

6

-

-

... More
Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required

-

-

-

... More
32 mm dia

20

-

-

... More
SUB-HEAD - I : UPS SYSTEM

-

-

-

... More
Supply, installation, testing & commissioing of 10 KVA UPS at 0.99 input power factor with SNMP card, compatible for BMS connectivity on backnet/MODBUS, inbuilt isolation transformer as per specification given in the document with following broad features.

-

-

-

... More
THD(i) shall be less than 3% in the entire loading range.

-

-

-

... More
UPS shall carry design output at 40 deg.

-

-

-

... More
Shall have soft start and hold of for incoming supply.

-

-

-

... More
Invertor capability to supply 150% load for 5 sec.

-

-

-

... More
Single Phase Input and Single Phase Output. ( Input - 220V - 240V, Single Phase, 2 wire. / Output - 220-240 Volt, Single Phase, 2 Wire.)

-

-

-

... More
Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.

-

-

-

... More
Battery shall be external type with rack and suitable for 30 minute backup on 100% load.

-

-

-

... More
Suitable size of copper cable between UPS and battery bank shall be provided

-

-

-

... More
UPS described as above

1

-

-

... More
Supply, installation, testing & commissioing of 20 KVA UPS at 0.99 input power factor with SNMP card, compatible for BMS connectivity on backnet/MODBUS, inbuilt isolation transformer as per specification given in the document with following broad features.

-

-

-

... More
THD(i) shall be less than 3% in the entire loading range.

-

-

-

... More
UPS shall carry design output at 40 deg.

-

-

-

... More
Shall have soft start and hold of for incoming supply.

-

-

-

... More
Invertor capability to supply 150% load for 5 sec.

-

-

-

... More
Three Phase Input and Three Phase Output. ( Input - 340V - 470V, Three Phase, 4 wire. / Output - 400-415 Volt, Three Phase, 4 Wire.)

-

-

-

... More
Shall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volt cells.

-

-

-

... More
Battery shall be external type with rack and suitable for 30 minute backup on 100% load.

-

-

-

... More
Suitable size of copper cable between UPS and battery bank shall be provided

-

-

-

... More
UPS described as above

1

-

-

... More
SUBHEAD - IX : AC Equipment

-

-

-

... More
SITC of 1.5 Ton Hot and Cold Split Air Conditioner Make- Daikin/Mitsubishi/Toshiba

25

-

-

... More
S/F MS Outdoor Stand

25

-

-

... More
S/F 5 KVA Stabilizer copper winding Make- V-Guard/Luminous / Blue Star

25

-

-

... More
S/L 3 x 2.5 Sqmm core flexible Copper Counductor Make- Finolex/Polycab/RR Cable

300

-

-

... More
S/L drain Pipe 25mm with Albow socket

175

-

-

... More
S/L Copper Refrigerent pipe 5/8 and 1/4

250

-

-

... More
SUBHEAD - I : Geyser Equipment

-

-

-

... More
SITC of 25 Ltr. Glass line Geyser with all accessories Make- Havells/Bajaj or Eq

9

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.